Multiples EM_ 1.4. Install 1X1/1X2/1X3/1X4 Housings. Installation Instructions for. This product is suitable for indoor locations.

Similar documents
Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

Round or Square Type IC Down Light Housing with LED Lamp for Flangeless Trims E3_L_-L_DI 1.4

Round or Square Chicago Plenum Down Light Housing with Lamp

Install the Housing. Installation Instructions for Entra Round or Square Type IC, Air-tight New Construction Adjustable LED Housing EN3_-LH9_ 1.

with Lamp Install the Housing with Adjustable Bars Installation Instructions for LED E3_-L_DN 1.1 ½ to ¾ ¾ or thicker

Reflections Housing with EldoLED and Lutron Hi-lume Drivers EDIHE_ 1.4

Prepare the Fixture. Sage 37 Bath. Back Plate Installation (Horizontal) Installation Instructions for 700BCSAGW37_

Micro Channel. Shorten the Fixture (optional) Installation Instructions for 700UMCD_ UNILUME. This product is suitable for damp locations.

Installation Instructions for Zip Suspension Downlight with Remote Power and 4" Square or Round Canopy

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

C 0.05" ALLEN WRENCH. Installation Instructions for Cirrus Channel Suspension T1 with 4" Square or Round Canopy. Section One: Adjusting Cable Position

Connecting the Channel A

Installation Instructions for Cirrus Suspension Downlight with Power - End Feed. Section One: 4" Flush Canopy Version

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

EXPLODED VIEW AND PART CALL OUT ASSEMBLING THE METALUX DF SERIES FRAME KIT

THIS SHEET CONTAINS IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS.

LIGHT FIXTURES MUST BE COMPLETELY INSTALLED PRIOR TO CEILING CONSTRUCTION

INSTALLATION INSTRUCTION Silo Multiples - New Construction Housing MT-4*15, MT-4*10

DOWNLIGHT LED SERIES INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR FLUSH MOUNT FIXTURES

INSTALLATION INSTRUCTIONS FIXTURE SERIES: SAE 202 MOUNTING TYPE: RECESSED WALL / SLOT PAGE: 1 OF 8

Inde-Pendants Family. 32L Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No Installation instructions for 32L-Rxx-P

INDIVIDUAL MOUNTING: T-Bar

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

Installation Instructions for TruLine 1.6A 24VDC. Section One: Basic Configuration Options

INSTALLATION RECOMMENDATIONS For The Con-Tech ODYSSEY Line Voltage Flexible Track System

Installation Instructions for DIY or Completed 45 Degree Light Channel

Lightplane 3.5 Recessed

General Installation Instructions LED

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

Installation Instructions For TruLine 1.6A 24VDC

Inde-Pendants Family. 32L Surface Mount Cylinder with Ring Plaster Trim, Grid and Drywall Ceiling Types. Document No

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Power Vault Adapter. Install the Power Vault Adapter to MonoRail Power Feed Canopies & Recessed Can Transformer. Installation Instructions for

IMPORTANT: PLEASE RETAIN THIS INSTRUCTION MANUAL FOR FUTURE REFERENCE

TH Place, Maspeth, NY Instruction Manual for UNO Exit Signs

DRYWALL CEILING SPLINE KICKER REFLECTOR DIFFUSER LENGTH TABLE DIFFUSER LENGTH TABLE DESCRIPTION 2' IND 3' IND 4' IND 6' IND 8' IND

Line volt rail & fixtures. Low volt quick connect fixtures with transformers

HP 2 SERIES Integral Driver - Solid State LED

Installation Instructions

RBP-1215B-RX DODGE RAM QUAD CAB RX3

Installation and Assembly: In-wall Mount for 32" to 71" Flat Panel Displays

HP-2 / HP-4 Wall Wash Recessed T-Bar Installation Instructions Overview

INSTALLATION INSTRUCTIONS Xenix Incandescent Series XN12, XN24, XN36, XN48

Installation Instructions for DIY or Completed Light Channel.6 Millwork

Repair Instructions. Replacing a La Z Time Mechanism Side Subassembly. Remove the Back(s): Remove the Mechanism Assembly: CAUTION.

Installation Instructions For Aurora Dual MR16 Round & Square Edge 3.3" Fig.1 Complete Fixture ADJUSTABLE GEARS HIDDEN BEHIND THE LAMP PAN LOCK

compile system INSTALLATION GUIDE Updated January 2019

DX-TVMLPTB03. Low-Profile TV Wall Mount ASSEMBLY GUIDE. For either wood-stud or concrete wall installations

INSTALLATION INSTRUCTIONS IMPORTANT SAFEGUARDS SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS

DETAILED ILLUSTRATION

Installation Instructions

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

MIL-STD B (SH) UPDATE

B235 Mobius Sconce Page 1 of 6

Joiner Kit Joiner bracket (x1) Biscuit aligners (x2) Trim Flange

Franklin Mills Stackable Movable Lateral Instructions

Bionic 4 PERIMETER, CONTINUOUS RUN X3, X7

LINESSE LINEAR LUMINAIRE 3 RECESSED CV2424

General Installation Instructions

SAE of 7 "R" (REGRESSED) POSITION "S" (SHIELDING AT TOP) POSITION. Tools Required

INSTALLATION INSTRUCTIONS

Custom Pendant- Hardwire Assembly and Installation Instructions

INSTALLATION INSTRUCTIONS

MM750 Installation Instructions

2. Connect driver to power source leads. After connections are made, place driver above ceiling. SEE MINIMUM SPACE REQUIREMENTS BELOW.

ETC Installation Guide

Wiring Techniques for Wiring a Lamp

Octagon Vinyl Gazebo Assembly Instructions For 10 & 12 Models

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

HO4 Surface Mount Installation Instructions Overview

Assembly Instructions for model: VMPR1

Woven Leather Chandelier Large Assembly and Installation Instructions

INSTALLATION INSTRUCTIONS

ZIP CLOUD SUSPENDED INSTALLATION MANUAL

Ceiling Tile Installations Part 1. Sheetrock Installations Part 2. WolfVision Support 2055 Sugarloaf Circle, Suite 125 Duluth, GA 30097

Angled Side Flush with Panel Face

Installation Instructions

HP-2 / HP-4 Wall Wash Recessed Spackle & Visible Flange Installation Instructions Overview

Figure A. Figure B. Figure C. Figure D

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS

CONTENTS TOOL LIST U P S I D E I N N O V A T I O N S, L L C RAMP AND STEP SYSTEM ASSEMBLY INSTRUCTIONS. Revised: June 2013

Assembly Instructions

Assembly Instructions

Octagon Vinyl Gazebo Assembly Instructions

INSTALLATION AND CARE INSTRUCTIONS

DLA-E (Philips EvoKit) The DLA-E is designed to install in the mounting slot of the Philips EvoKit SR retrofit kit.

WILDING WALLBEDS INSTALLATION INSTRUCTION Side Mount

Installation And Care Instructions. Vertical Honeycomb Shades

Hawko Zhaga Systems Installation Instructions

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH1-ARE, AH1-ARB, AH1-ASE, AH1-ASB. Fig.

Installation Instructions For Aurora Halogen Accent Housing 3 Round & Square Trimless AH2-ARE3 & AH2-ASE3. Fig.1 Complete Fixture

MM340 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

STEP 1 : DESTROYER FRONT BUMPER INSTALL GATHER YOUR TOOLS AND LAY OUT YOUR PARTS... *shorty bumper to show hardware* Tools Required:

HP-2 / HP-4 / HP-6 Ceiling to Wall Inside Corner Installation Instructions Overview

RAIL 4 PERIMETER RP4D RECESSED T-BAR LED TELESCOPIC, INTEGRAL DRIVER

Arched Top Lantern Pendant Assembly and Installation Instructions. Country of Destination: US/CN UK/EU/AUS Middle East

SunTrackerTwo Preparation

Transcription:

Installation Instructions for 90EMULTI Multiples EM_. GENERAL PRODUCT I NFORMATION: This product is suitable for indoor locations. This product can be dimmed with a standard electronic dimmer or a 0-0V dimmer depending on the wiring configuration. This instruction shows a typical installation. Install X/X/X/X Housings NOTE: For X models, skip to section. C A CAUTION - RISK OF FIRE This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Use minimum 90 c supply conductors. C BUTTERFLY BRACKET ADJUSLE BAR OPENING Rotate the tabs on the butterfly brackets 90 so that the adjustable bar openings are aligned. B INNER ADJUSLE BAR ADDITIONAL JOIST BUTTERFLY BRACKET NOTE: The adjustable bars can be mounted to joists that are spaced " - " apart. OUTER ADJUSLE BAR STOP POINT Align the bottom of the adjustable bars with the bottom of the ceiling joists. Slide the inner adjustable bar completely through the adjustable bar openings in the butterfly brackets. Make sure the screw is on top. Slide and push the outer adjustable bar completely onto the inner adjustable bar so that the tab clicks into place behind the stop point.this will prevent the adjustable bars from coming apart. E Level the adjustable bars and tighten the screws completely into the joists and drive an additional screw or nail through the provided hole to secure the adjustable bars in place. Repeat steps through for the other side of the housing.

D ADJUSLE BAR B JOIST ADDITIONAL NOTCH NOTE: The electrical box cover must be accessible for wiring the fixture. If the housing must be positioned so that the electrical box is not accessible, skip to section to wire the fixture and revert back to this step to complete adjustments. Adjust the housing position (horizontal position) by sliding the housing on adjustable bars. When the desired location is achieved install and tighten the two # screws to lock the butterfly brackets onto the adjustable bars. NOTE: Notches in the housing can be used to align multiple housings using a laser or string. NOTE: Height adjustment to the housing will occur later in the installation. E C D B NOTE: The adjustable bars can be mounted to joists that are spaced " - " apart. Align the bottom of the adjustable bars with the bottom of the ceiling joists. Level the adjustable bars and tighten the screws completely into the joists and drive an additional screw or nail through the provided hole to secure the adjustable bars in place. ADJUSLE BAR Install the X Housing A OUTER ADJUSLE BAR INNER ADJUSLE BAR NOTCH Adjust the housing position (horizontal position) by sliding the housing on adjustable bars. SIDE VIEW BRACKET STOP POINT When the desired location is achieved install and tighten the two # screws to lock the butterfly brackets onto the adjustable bars. ADJUSLE BAR OPENING NOTE: Notches in the housing can be used to align multiple housings using a laser or string. Slide the inner adjustable bar completely through the adjustable bar openings in the brackets. Make sure the screw is on top. Slide and push the outer adjustable bar completely onto the inner adjustable bar so that the tab clicks into place behind the stop point.this will prevent the adjustable bars from coming apart. NOTE: Height adjustment to the housing will occur later in the installation. Repeat steps through for the other side of the housing.

Connect Power to the Housing A S C Wiring for High Output Non-IC ELECTRICAL BOX COVER Push up on the tabs on the electrical box and remove the electrical box cover. Connect the neutral power line wire to the white fixture lead wire with a wire nut. Connect the hot power line wire to the black thermal protector wire with a wire nut. B Make sure that housing is grounded in accordance with local electrical codes. Properly connect the gray and purple dimming wires when applicable. Replace the electrical box cover. Make sure that the top edge of the cover snaps under the tab. WARNING: RISK OF FIRE: When using the housing electrical box for power feed through, for IC housings use MAX - # AWG, or - # AWG branch circuit conductors suitable for 90c. Install the conduit to the housing electrical box. Run the power line wires into the housing electrical box. D Wiring for IC or Low Output Housing WARNING: For X models, only make external connections to the designated junction box. Follow the safety labels on the junction boxes for direction. 0 9 Wiring for Non-IC Housing- Section C Wiring for IC Housing - Section D WARNING: RISK OF FIRE: When using the housing electrical box for power feed through, for NON-IC housings use MAX - # AWG, or - # AWG branch circuit conductors suitable for 90c. 9 0 Connect the neutral power line wire to the white fixture lead wire with a wire nut. Connect the hot power line wire to the black fixture lead wire with a wire nut. Make sure that housing is grounded in accordance with local electrical codes. Properly connect the gray and purple dimming wires when applicable. Replace the electrical box cover. Make sure that the top edge of the cover snaps under the tab.

Install Drywall Install Plaster Ring (For Flangeless Versions) A A CUT OUT TEMPLATE NOTCH Remove the backing of the tape and adhere the cut out template at the desired location. The notches on the template may be used for alignment. Mark or cut the drywall using the template, then remove it from the ceiling and dispose. FIXTURE B DRYWALL OPEN VERSION TRIMMED VERSION DRYWALL Align the cut out section of drywall with the housing and install drywall. WARNING: Risk of Fire: Non-IC housings are not intended to be in contact with or covered with combustible materials and insulation. Do not install insulation within inches of the housing sides or above in such a manner to entrap heat. For FLANGELESS versions, go to section. For FLANGED versions, go to section. JOIST Insert the plaster ring into the cut out and onto the fixture housing. Align the holes of the plaster ring with the holes in the housing and secure the plate in place with the plaster ring screws. For OPEN versions, use the outer (higher) holes in the housing. For TRIMMED versions, use the inner (lower) holes in the NOTE: If the plaster ring holes cannot match with the holes in the housing because of the housing being to recessed into the ceiling, see the following steps to adjust the height of the housing in order to install the plaster ring screws. NOTE: The plaster ring will not lay flush onto the ceiling at this point, adjustments to the housing height are needed (see next step).

B FIXTURE D UNWANTED GAP PLASTER RING WING NUT CEILING PLASTER GUARD ROOF OF Install the plaster guard onto the housing with the provided double sided tape. HANDLE E Adjustment to the fixture housing is needed for the plaster ring to be flush with the ceiling. Reach inside the housing and loosen the two wing nuts on each butterfly bracket. While using the handle inside the housing for leverage, apply upward pressure to the housing by pushing up on the roof of the housing and adjust the fixture placement until the plaster ring is flush to the ceiling and tighten all the wing nuts. Using a wrench, snug the wing nuts. CAUTION: do not over tighten; this will result in stripped threads. C DRYWALL Properly plaster onto the plaster plate and drywall. DRYWALL HOLE F 9 Finish around the collar to match drywall and remove the plaster guard. Secure the plaster ring to the ceiling using the provided drywall screw holes. 0 Skip to section.

Install Flange Ring (For Flanged Open Housing Versions) A FLANGE RING B FIXTURE UNWANTED GAP FLANGE RING WING NUT CEILING FLANGE RING FIXTURE ROOF OF HANDLE FLANGE RING FLANGE RING DRYWALL Insert the flange ring into the cut out and onto the fixture housing. Align the holes the flange ring with the holes in the housing and secure the plate in place with the plaster ring screws. Adjustment to the fixture housing is needed for the flange ring to be flush with the ceiling. Reach inside the housing and loosen the two wing nuts on each butterfly bracket. While using the handle inside the housing for leverage, apply upward pressure to the housing by pushing up on the roof of the housing and adjust the fixture placement until the plaster ring is flush to the ceiling and tighten all the wing nuts. Using a wrench, snug the wing nuts and /th of a turn. NOTE: If the flange ring holes cannot match with the holes in the housing because of the housing being too recessed into the ceiling, see the following steps to adjust the height of the housing in order to install the flange ring screws. NOTE: The flange ring will not lay flush onto the ceiling at this point, adjustments to the housing height may be needed (see next step). Install the Module A CONNECTOR SOCKET MODULE Push the module connector(s) into the electrical box socket(s) located inside the fixture housing.

C Adjust the Module 9A MODULE LED COLLAR Align the spring clips on the module to the brackets inside the fixture housing and push the module completely in place. Install the Trim (Trimmed Version, Adjustable Modules Only) A BRACKET MODULE OPENING WARNING: Always squeeze the two tabs when adjusting the LED housing. Failure to do so will damage the finish. Squeeze the LED housing tabs and rotate the LED housing to the desired position. Rotate the collar to move the tab locations if necessary. Optics and Lenses (Adjustable Modules Only) 0A TRIM LED COVER OPTIC Align the brackets on the trim with the openings in the module(s). B LENS (see step ) EXTENDED LED COVER Unscrew and remove the LED housing cover. Gently push the trim into the lamp housing so all the brackets snap into place. Remove the optic. If installing an optional lens, rest the lenses inside the extended lens housing cover ( lenses maximum). WARNING: Use only the extended LED housing cover shipped with the lens. Failure to do so will result in damage to the fixture and/or injury. Install the optic (replacement or existing) inside the LED housing cover. WARNING: ensure that the optic is seated and aligned properly to avoid damage to the LED when installing the cover. See notes in step B before proceeding. Screw the LED housing cover back on.

0B INSTALLATION VIEW WITHOUT LENSES Removing the Module A MODULE ADJUSLE FIXTURE LED BUTTERFLY BRACKET INSTALLATION VIEW USING LENSES LED WARNING: Always squeeze the two tabs when adjusting the LED housing. Failure to do so will damage the finish. In order to have the clearance to remove the module, the LED housing must be rotated: Squeeze in the two tabs on the LED housing and rotate the housing towards either end of the fixture housing. Grip the LED module and pull the LED housing straight down. If any resistance is given, rotate it to the next adjacent side. See section for reinstallation. B GENERAL ILLUMINATION AND WALL WASH The extended lens housing cover must be tightened lessthan-snug. Stop tightening the moment any resistance is felt. The cover will not sit flush to the base when using lenses. Do not try to force the cover to become flush. Remove the General Illumination and Wall Wash modules using a flathead screw driver to gently pry the module from the housing. SAVE THESE INSTRUCTIONS! 00 Linder Ave, Skokie, IL 00.0.00 www.element-lighting.com 0 Tech Lighting, L.L.C. All rights reserved.the "Element" graphic is a registered trademark of Element. Element reserves the right to change specifications for product improvements without notification. A Generation Brands Company