Impulse response. Frequency response

Similar documents
CLIO 10, by Audiomatica, is the new measurement software for the CLIO System. The CLIO System is the easiest and less expensive way to measure:

n CLIO 12, by Audiomatica, is the newest measurement software for the CLIO System. The CLIO System is capable of measuring: n electrical networks n

CLIO Pocket is Audiomatica's new Electro-Acoustical Multi-Platform Personal measurement system.

ELECTRICAL & ACOUSTICAL TESTS

CLIO Software. Release 1.5 Version Pocket. Survival Guide

Transfer Function (TRF)

APPLICATION NOTE MAKING GOOD MEASUREMENTS LEARNING TO RECOGNIZE AND AVOID DISTORTION SOUNDSCAPES. by Langston Holland -

CLIO ELECTRICAL & ACOUSTICAL TESTS

SYSTEM ONE * DSP SYSTEM ONE DUAL DOMAIN (preliminary)

3D Distortion Measurement (DIS)

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Practical Applications of the Wavelet Analysis

System Two Cascade Plus Audio Test and Measurement System

Audiomatica s CLIO Pocket Electro-Acoustical Portable Measurement System

3D Intermodulation Distortion Measurement AN 8

CLIO Software. Release 12 Version Quality Control. User's Manual

Acoustic Measuring System

Since the advent of the sine wave oscillator

Measurement of weighted harmonic distortion HI-2

Loudspeaker Design & Measurement

TBM - Tone Burst Measurement (CEA 2010)

Multi-Instrument. Instroduction. Oscilloscope. Virtins Technology. Turn a PC into Multiple Virtual Instruments! (Mixed Signal Display)

QC Software Feature Overview

not overpower the audience just below and in front of the array.

group D DSA250 Specifications 2-WAY FULL-RANGE DIGITALLY STEERABLE ARRAY See TABULAR DATA notes for details CONFIGURATION Subsystem Features

WinMLS I very much like the convenience of the tool and how quickly measurements can be made - Christopher Pye, Integral Acoustics, Canada

TS9050/60. microgen. electronics TM FM Modulation and Spectrum Analyser

Design and Production. Analog & Digital Audio. Fast & Accurate Measurements. Scalable Architecture. Superior Specifications.

PRODUCT DATA. DIRAC Room Acoustics Software Type Photo courtesy of Muziekcentrum Frits Philips, Eindhoven, The Netherlands

Microphone Test System

AXIHORN CP5TB: HF module for the high definition active loudspeaker system "NIDA Mk1"

Tolerances of the Resonance Frequency f s AN 42

The Woofer Tester Pro. Integrated Speaker Measurement & Design. Web: Phone:

Rub & Buzz Detection with Golden Unit AN 23

Ulteé Audiotechnik. Professional Audio Measurement. User s Manual

NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer.

VQ 60. Product Description. Features. Applications

HOW TO CREATE EASE LOUDSPEAKER MODELS USING CLIO

14 fasttest. Multitone Audio Analyzer. Multitone and Synchronous FFT Concepts

Product Description. Features. Applications

DiGi++ Noise Meter. Main functions

ENGINEERING STAFF REPORT. The JBL Model L40 Loudspeaker System. Mark R. Gander, Design Engineer

Acoustic Calibration Service in Automobile Field at NIM, China

klippel qc system 100% end-of-line testing

Lab 3 FFT based Spectrum Analyzer

IE-35 & IE-45 RT-60 Manual October, RT 60 Manual. for the IE-35 & IE-45. Copyright 2007 Ivie Technologies Inc. Lehi, UT. Printed in U.S.A.

The ArtemiS multi-channel analysis software

FLEXUS fx100 AU D I O A N A LY Z E R AUDIO TEST & MEASUREMENT SOLUTIONS. Analog & Digital Audio. Fast Measurements.

11/19/2013 3:49 PM Page 1 of 26

SSE 10 SPECIFICATIONS

Specifications. Analog analyzers. Inputs. Measurement functions. 16 Audio Analyzer UPL. RMS value, selective

NEW! XL2 EXELLINE HANDHELD AUDIO AND ACOUSTIC ANALYZER LESS NOISE. MORE SOUND. Sound Level Meter. Real Time Analyzer. FFT Analyzer.

Causes for Amplitude Compression AN 12

SSE 12 SPECIFICATIONS

DESIGN OF VOICE ALARM SYSTEMS FOR TRAFFIC TUNNELS: OPTIMISATION OF SPEECH INTELLIGIBILITY

Balanced Armature Check (BAC)

FA12ac. Self-Powered 12 inch Coaxial Loudspeaker. product specification. Performance Specifications 1

SSE 26 SPECIFICATIONS

ECEn 487 Digital Signal Processing Laboratory. Lab 3 FFT-based Spectrum Analyzer

Technical Guide. Installed Sound. Recommended Equalization Procedures. TA-6 Version 1.1 April, 2002

Application Note: Headphone Electroacoustic Measurements

FFT Spectrum Analyzer

Mark Analyzer. Mark Editor. Single Values

RM28ac. Self-Powered Dual 8 inch Coaxial Reference Monitor. product specification. Performance Specifications 1

Advanced Test Equipment Rentals ATEC (2832)

20 VOICE COIL. Figure 7: BlieSMA T34A-4 SoundCheck CSD waterfall plot

Measurement at defined terminal voltage AN 41

Sub218Lac. Self Powered Dual 18 inch Direct-Radiating Subwoofer. product specification. Performance Specifications 1

ESA400 Electrochemical Signal Analyzer

CONTENTS. How to get started FINEQC calibration procedure 3

Audio Measurements with a Network Analyser

Measuring procedures for the environmental parameters: Acoustic comfort

ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation

Sound engineering course

Measurement Procedure & Test Equipment Used

Minirators MR-PRO / MR2

V12. Product Description. Features. Applications

Keysight Technologies 8 Hints for Making Better Measurements Using RF Signal Generators. Application Note

SPECS. Impulse (4 and 8 ohm) Two-Way Weather-Resistant Injection-Molded Speaker System SPECIFICATIONS. Built under U.S.

Spectrum Analyzer R&S FS300

Production Noise Immunity

ArbStudio Arbitrary Waveform Generators

Common Amplifier Format Rane MA 3

Audio Analyzer R&S UPV. Up to the limits

VLS 15. Technical Data Sheet. Product description. Features

Prism Sound dscope Series III. Specifications. 302x245x84mm (2U mounting kit available). Weight:

SIGNAL RECOVERY. Model 7265 DSP Lock-in Amplifier

Week 1. Signals & Systems for Speech & Hearing. Sound is a SIGNAL 3. You may find this course demanding! How to get through it:

Polar Measurements of Harmonic and Multitone Distortion of Direct Radiating and Horn Loaded Transducers

Loudspeaker Power Ratings

Real time spectrum analyser sound level meters

Sampling and Reconstruction

Measurement of Amplitude Modulation AN 6

DSI-600 EMI Test & Measurement Receiver

Description. 175 watts Test Voltages: 34.2 volts rms 68.3 volts peak R SR (1.15 R E. ): 6.67 ohms. Suspending the Xi-1082

PRODUCT DATA. DIRAC Room Acoustics Software Type 7841

WHITEPAPER. Advantages of Christie Vive Audio planar ribbon and line array technologies for cinema sound

Airborne Sound Insulation

Brief review of the concept and practice of third octave spectrum analysis

Transcription:

CLIOwin 7, by Audiomatica, is the new measurement software for the CLIO System. The CLIO System is the easiest and less expensive way to measure: - electrical networks - electronic equipment - loudspeaker systems - telephones & hearing aids - environmental noise - rooms acoustics - quality of production lines CLIOwin 7 runs on a standard PC computer driving the measurement card and accessory hardware supplied by Audiomatica; the power, precision and reliability of the resulting instrument is 100% warranted. CLIOwin 7 is a new design based on a huge work which is the synthesis of more than 15 years experience and excellence in electro-acoustic measurement systems and gives you all the power and flexibility you need. CLIOwin 7 refines all the well established measurement techniques already implemented in the CLIO system while adding several new functionality.

CLIOwin 7 SOFTWARE VERSIONS You can start with - or upgrade to - CLIOwin 7 in three different ways: 1) CLIOwin 7 Lite. Limited but still powerful, the perfect entry point with its unbeatable price. 2) CLIOwin 7 Standard. If you need the full power of our laboratory grade professional package. 3) CLIOwin 7 Quality Control. For testing and controlling a production line. CLIOwin 7 MEASUREMENT TECHNIQUES Compared to other measurement systems, CLIOwin 7 concentrates the power of many different instruments into a single one. Three different measurement techniques are available for system identification and characterization: MLS & LogChirp analysis using either pseudo-random noise or logarithmic chirps as stimuli Sinusoidal Sweeps using sinusoidal signals FFT, RTA and Live Transfer Function letting you the choice of any stimulus, even live music. While other instruments offer one single possible measurement choice, CLIOwin 7 gives you three alternatives permitting to view the physical phenomenon like frequency response, impedance or other parameters, from three different points of view. The final result will be then validated by the consistency of these measurements: as any expert technician knows, this is the correct approach that should always be adopted. The following specialized control panels are dedicated to other specific measurements: Sound Level Meter a IEC61672 integrating sound level meter with Leq and frequency analysis Linearity and Distortion measures the non linear behavior of an electronic equipment Interactive L-C-R Bridge permits passive components measurement on the fly Wow&Flutter Meter with time and frequency analysis Frequency Counter Beyond measured results you get sophisticated post-processing tools for: Thiele&Small Parameters for loudspeaker characterization ISO 3382 Acoustical Parameters for rooms and auditoria characterization Waterfall plots to evaluate sound decay as 3D or Color graphs Directivity analysis for loudspeaker characterization as Color maps, Circular or 3D plots Using all the aforementioned measuring and post-processing techniques it is possible to tailor powerful Quality Control scripts that will manage and identify any production line of electronic or electro-acoustic devices. MLS & LOG CHIRP ANALYSIS CLIOwin 7 implements linear systems measurement with the well established MLS analysis technique now enriched by the possibility of using Logarithmic Chirps. The result is the system s impulse response measurement, by means of sophisticated algorithms; this lets you perform accurate anechoic analysis of loudspeakers and room acoustics evaluation. The measurement is highly accurate and extremely fast to execute; the data recorded by the computer, can be instantly analyzed or stored for later processing. What MLS & LogChirp analysis gives you: Frequency response Phase response, minimum and excess. Group Delay Impedance measurement Step response Energy-Time curve (ETC) Schroeder reverberant decay Impulse response Frequency response The actual software release permits, among other features, the following: Sequence length from 4k to 256k points Input signal autorange for optimum signal to noise ratio Selectable analysis window Manual or continuous programmable time average

Loop function with continuous measurement Mathematical operations on data in memory Automatic merge between near and far field Selectable smoothing (1/2 to 1/12 of octave) SINUSOIDAL ANALYSIS CLIOwin 7 executes sinusoidal analysis with a digital filtering of input signal to achieve the highest noise-immunity; in this way you add the power of the PC to the most traditional frequency analysis. The sinusoidal technique is oriented to: Frequency response Phase response Continuous and stepped sweeps Frequency resolution from 1/3 to 1/48 oct. Impedance measurement 2nd, 3rd, 4th, 5th harmonic and THD plot vs. frequency Gating system with auto-delay for quasi-anechoic measurements FFT, RTA & LIVE TRANSFER FUNCTION These measurements are implemented with an interactive control panel that permits the simultaneous display of time and frequency domains. Three operating modes: Narrowband FFT Octave bands RTA LIVE transfer function The main features are: Two channels measurement and display Internal trigger with programmable delay FFT from 256 points up to 128k points Linear or exponential averaging Max hold and min hold functions Linear or logarithmic frequency axis 1/3 octave or 1/6 octave RTA display Equal Loudness Contours display Frequency smoothing With FFT it is possible to easily execute bursted distortion measurements delivering, for a definable short period of time, very high power to the load. MULTI-METER & SIGNAL GENERATOR This multi-meter control panel is a real-time, interactive, measuring instrument giving the following functionality: SPL Meter (dbspl, dba, dbc) Millivoltmeter (V, dbv, dbu, dbr) Frequency Counter (Hz) Distortion meter: THD and IMD (%, db) L-C-R Bridge (H, uf, Ohm) Crest Factor Fast and Slow integration The programmable signal generator is capable of the following functions or signals generation: Sinusoids with burst and FFT bin round Two sinusoids Sinusoidal response + harmonics Narrowband FFT Octave bands RTA LIVE transfer function Multimeter and signal generator

Multitones All Tones Linear or Logarithmic Chirps MLS (Maximum Length Sequences) White noise Pink noise Wave files (.wav) playback and save IMPEDANCE MEASUREMENTS AND THIELE&SMALL PARAMETERS The impedance measurements can be done with a direct connection to the analyzing hardware or with an external amplifier and a sensing resistor both in constant current or constant voltage configurations; the evaluation of speaker parameters uses the added-mass or known-volume methods and least square error routines. WATERFALL AND DIRECTIVITY The Waterfall and Directivity post processing routines give CLIOwin 7 the possibility of making 3D or Color plots by adding a third dimension (time or degrees) to classical amplitude-frequency graphs. Waterfalls are used to characterize the anechoic sound decay of a loudspeaker or the sound decay in a room. Impedance and T&S parameters Waterfall Color Waterfall The Waterfall post processing permits the following 3-D or Color types of analysis: Cumulative spectral decay (CSD) Energy Time Frequency (ETF) Directivity analysis characterizes the radiation of a loudspeaker versus vertical or horizontal angle. The Directivity post processing permits the following analysis: 3-D directivity (waterfall like) Color map directivity Classical polar plots Leq ANALYSIS With the Leq Analysis control panel it is possible to execute real-time capture and level measurement of any kind of signal present at CLIO s input. The behaviour of the instrument closely resemble that of a graphical level recorder plus direct-todisk data capture. When analyzing an acoustical event this control panel gives you complete informations about the equivalent continuous sound Directivity color map Circular polar plots Leq analysis

level (Leq) and related quantities according to IEC 61672 standard; if used together the FFT frequency analysis you get a complete integrating sound level meter. ACOUSTICAL PARAMETERS With the Acoustical Parameters control panel it is possible to evaluate the acoustical behaviour of a room and carry out sophisticated post processing of a measured impulse response to calculate the acoustical parameters as defined by the ISO 3382 standard. These quantities describe the behaviour of auditoria, concert halls and are applicable to any room intended for speech or music reproduction. LINEARITY AND DISTORTION Linearity and Distortion analysis is a complete tool to inspect the non linear behavior of any electronic equipment as power amplifiers or preamplifiers. Up to 1250W/8Ohm (higher with external attenuator) THD vs. input or output SMPTE, DIN, CCIFF Intermodulation DUT s gain and deviation from linearity WOW & FLUTTER ANALYSIS CLIOwin 7 executes Wow & Flutter analysis measuring the frequency modulation that follows instantaneous speed variations due to mechanical imperfections in analog recording or playback devices. IEC and NAB standards Time and frequency display CLIOwin 7 USER INTERFACE The various control panels give you the impression of facing a real instrument. The software displays multiple curves giving you powerful editing capabilities together import and export facilities as a link to simulation programs. Featuring: Measurement session management with snapshot of current desktop ASCII data output Enhanced Metafile, Bitmap, PNG, GIF, JPEG graphics export LITE VERSION LIMITATIONS MLS & Log Chirp -No Log Chirp -Size limited to 32k -Group Delay disabled -No Octave Filter Postprocessing -No MLS Impedance measurements Waterfall & Directivity -Only Waterfall, No Directivity No Acoustical Parameters FFT -Only RTA measurements ISO 3382 Acoustical Parameters Distortion vs. output power Linearity analysis Wow & Flutter -No FFT Narrowband -No Live Transfer Function Sinusoidal -No 4th, 5h harmonic and THD display T&S Parameters -No LSE analysis No Leq Analysis No Linearity & Distortion Analysis Signal Generator -No Multitones -No All tones -No Chirp

QUALITY CONTROL The Quality Control software extension for CLIOwin 7 is a powerful suite for executing state of the art production line testing. CLIOwin 7 QC implements all the measurement techniques found in the standard software adding a versatile script processor that handles the test sequence most appropriate for your needs. CLIOwin 7 QC is able to test the production of loudspeakers, drivers, microphones, amplifiers and any other electroacoustic device. CLIOwin 7 QC can interact with external hardware or production line controllers in addition to PC peripherals, computer networks or with custom written software to implement a fully automatic line. Some of the measurements possible: Frequency response using MLS, LogChirp or Sinusoidal Sweep Impedance response using MLS, LogChirp or Sinusoidal Sweep Rub & Buzz detection Polarity Single harmonic or THD response with Sinusoidal Sweep Narrowband FFT analysis with definable stimulus T&S parameters Sensitivity Frequency THD IMD Noise POWERFUL HARDWARE CONTROL The key feature of the CLIO System running CLIOwin 7 is the precision, laboratory grade, hardware control that gives you complete, instant access to all the measurement parameters and let you easily interact via software to adapt your measurement interface to any environmental need; using CLIO you get results that are 100% warranted by the hardware interface built by Audiomatica. Separate inputs management and control Free running Peak Meter to monitor input signal Input polarity control 0.1dB output level control Output DC voltage control CLIOwin 7 also integrates the software control for external hardware: Model 1, 2, 3 and 4 Amplifier & SwitchBox Turntable General Purpose I/O bits PC REQUIREMENTS Pentium II processor 64 MB RAM or more 1024x768 video Windows 98, ME, 2000 or XP Adobe Acrobat Reader 4 AUDIOMATICA VIA MANFREDI 12-50136 FIRENZE-ITALY TEL:+39-0556599036-FAX:+39-0556503772 E-MAIL: info@audiomatica.com WEB:www.audiomatica.com,www.cliowin.com ELECTRICAL & ACOUSTICAL TESTS