Development of a Walking Support Robot with Velocity-based Mechanical Safety Devices*

Similar documents
CONTENTS PRECAUTIONS BEFORE STARTING OPERATION PREPARATION FOR OPERATION CAUTIONS ON USE OPERATION

Robot Joint Angle Control Based on Self Resonance Cancellation Using Double Encoders

Sloshing Damping Control in a Cylindrical Container on a Wheeled Mobile Robot Using Dual-Swing Active-Vibration Reduction

An In-pipe Robot with Multi-axial Differential Gear Mechanism

Design and Control of the BUAA Four-Fingered Hand

Development of Flexible Pneumatic Cylinder with Backdrivability and Its Application

installation guide

HD installation guide

Instruction Manual. Manual Furniture Mover. Note: Owner/Operator must read and understand this instruction manual before using the furniture mover.

Active Vibration Isolation of an Unbalanced Machine Tool Spindle

Sensor system of a small biped entertainment robot

Development of Drum CVT for a Wire-Driven Robot Hand

EFFECT OF INERTIAL TAIL ON YAW RATE OF 45 GRAM LEGGED ROBOT *

Group Robots Forming a Mechanical Structure - Development of slide motion mechanism and estimation of energy consumption of the structural formation -

Figure 1: Unity Feedback System. The transfer function of the PID controller looks like the following:

INSPECTION AND CORRECTION OF BELLHOUSING TO CRANKSHAFT ALIGNMENT

CONTROLLING THE OSCILLATIONS OF A SWINGING BELL BY USING THE DRIVING INDUCTION MOTOR AS A SENSOR

Rectilinear System. Introduction. Hardware

PoeBot Building Instructions CCISD. Upper Gripper. Lower Gripper/ Spatula. PoeBot Instructions PLTW. Clear Creek ISD

Motion Control of a Three Active Wheeled Mobile Robot and Collision-Free Human Following Navigation in Outdoor Environment

Biologically Inspired Robot Manipulator for New Applications in Automation Engineering

DEVELOPMENT OF A HUMANOID ROBOT FOR EDUCATION AND OUTREACH. K. Kelly, D. B. MacManus, C. McGinn

PREVIEW COPY. Table of Contents. Lesson One Using the Dividing Head...3. Lesson Two Dividing Head Setup Lesson Three Milling Spur Gears...

Daily Maintenance. 2. Insert bobbin cases in to rotary hooks. Make sure bobbin thread is not over 2 inches long. Close bobbin case covers.

V-MOTION LITE USER GUIDE. Rat Rig All rights reserved.

Lab Exercise 9: Stepper and Servo Motors

Experiment 4.B. Position Control. ECEN 2270 Electronics Design Laboratory 1

Computer Numeric Control

The quadrature signals and the index pulse are accessed through five inch square pins located on 0.1 inch centers.

Autonomous Stair Climbing Algorithm for a Small Four-Tracked Robot

3,500/4,500lb. Vertical Cable Feighner Lift

SRV02-Series Rotary Experiment # 3. Ball & Beam. Student Handout

(1.3.1) (1.3.2) It is the harmonic oscillator equation of motion, whose general solution is: (1.3.3)

Automatic Control Systems 2017 Spring Semester

Figure 2.1 a. Block diagram representation of a system; b. block diagram representation of an interconnection of subsystems

MODEL T28173/T28174 ROLLER TABLES INSTRUCTIONS

Brother Industries, Ltd. Nagoya, Japan

Z-Truck Up-and-Down Motion. Y-Truck Side-to-Side Motion. Head. Squaring Plate. Sliding Plate FIGURE 1: THE CARVEWRIGHT MACHINE

Penn State Erie, The Behrend College School of Engineering

Machines. 6/16 Kenworth Place, BRENDALE Ph Fx RT-060S. Horizontal / Vertical Rotary Table INSTRUCTION MANUAL

Legacy Woodworking Machinery a division of Phantom Engineering. The Legacy CNC. Assembly Manual

Momentum and Impulse

New Solution for Walking Robot

Technical description

Vibration Fundamentals Training System

Model MFC-2 Split Frame Clamshell Operation and Parts Manual

Study of Vee Plate Manufacturing Method for Indexing Table

Dynamic analysis and control of a Hybrid serial/cable driven robot for lower-limb rehabilitation

Instruction Manual. EASY / WHISPER 2, 3, 4 & 5 Blades. Scan the QR code with a mobile device to view the installation video.

Optical Kit Encoder Page 1 of 11. Description. Mechanical Drawing. Features

Shuffle Traveling of Humanoid Robots

WALKING ROBOT LOCOMOTION SYSTEM CONCEPTION

4R and 5R Parallel Mechanism Mobile Robots

STERILIZATION The following are GUIDELINES for product sterilization.

Rapid Development System for Humanoid Vision-based Behaviors with Real-Virtual Common Interface

Momentum and Impulse. Objective. Theory. Investigate the relationship between impulse and momentum.

Design and Experiments of Advanced Leg Module (HRP-2L) for Humanoid Robot (HRP-2) Development

A Semi-Minimalistic Approach to Humanoid Design

A Do-and-See Approach for Learning Mechatronics Concepts

DEVELOPMENT OF THE HUMANOID ROBOT HUBO-FX-1

ROTARY TABLE OPERATION AND SERVICE MANUAL HORIZONTAL AND VERTICAL. Horizontal & Vertical. Rotary Table (HVRT) Tilting Rotary Table

Where: (J LM ) is the load inertia referred to the motor shaft. 8.0 CONSIDERATIONS FOR THE CONTROL OF DC MICROMOTORS. 8.

UKEMI: Falling Motion Control to Minimize Damage to Biped Humanoid Robot

Appendix Course Notes MIT Course Organizers. Chapter 7: LEGO Design

Hare and Snail Challenges READY, GO!

18600 Angular Momentum

Touching and Walking: Issues in Haptic Interface

Combot: Compliant Climbing Robotic Platform with Transitioning Capability and Payload Capacity

D102. Damped Mechanical Oscillator

SRV02-Series. Rotary Servo Plant. User Manual

n Measuring range ,02 N m to N m n Clockwise and counter-clockwise torque n Low linearity deviation of ± 0.05 % F.S.

CONTENTS: 1. General safety instructions Introduction... 1

Pushing Methods for Working Six-Legged Robots Capable of Locomotion and Manipulation in Three Modes

Relationship to theory: This activity involves the motion of bodies under constant velocity.

REPAIR INSTRUCTIONS. Cat. No Cat. No MILWAUKEE ELECTRIC TOOL CORPORATION. SDS Max Demolition Hammer. SDS Max Rotary Hammer

5. Transducers Definition and General Concept of Transducer Classification of Transducers

Bipedinno. 12-DOF Waist-high Robot

Miniaturization of a Quasi-Servo Valve and Its Application to Positon Control of a Rubber Artificial Muscle with Built-in Sensor

OPERATOR ADAPTER A21ABVA

RYOBI. 10 in. (254 mm) TABLE SAW MODEL NO. BTS15 REPAIR SHEET

Technical analysis and diagramming exercises

INSTALLATION INSTRUCTIONS 3 BULL BAR 99-04, 04 "HERITAGE" F-150/250LD 2WD, 97-04, 04 "HERITAGE" 4WD WD EXPEDITION/ WD EXPEDITION PART

Milind R. Shinde #1, V. N. Bhaiswar *2, B. G. Achmare #3 1 Student of MTECH CAD/CAM, Department of Mechanical Engineering, GHRCE Nagpur, MH, India

Screws. Introduction. 1. Nuts, bolts and screws used to clamp things together. Screws are used for two purposes:

INSTALLATION INSTRUCTIONS ATV SNOW PLOW WARN KIT PN: KAWASAKI KIT PN: KAF Application: Kawasaki Prairie

Student, Department of Mechanical Engineering, Knowledge Institute of Technology, Salem, Tamilnadu (1,3)

The line driver option offers enhanced performance when the encoder is used in noisy environments, or when it is required to drive long distances.

Finite Element Modeling of Early Stage Self-loosening of Bolted Joints Haoliang Xu 1, a, Lihua Yang 1, b,, Lie Yu 1,2, c

Budget Robotics Octabot Assembly Instructions

Data Sheet. HEDL-65xx, HEDM-65xx, HEDS-65xx Series Large Diameter (56 mm), Housed Two and Three Channel Optical Encoders. Description.

Lab 2: Introduction to Real Time Workshop

Ahsanullah University of Science and Technology (AUST) Department of Mechanical and Production Engineering

Rotary Fixture M/V/X CLASS LASER SYSTEMS. Installation and Operation Instructions

25-200H. 12 Planer / Jointer. with Helical Cutterhead. Parts List.

SitiK KIT. Team Description for the Humanoid KidSize League of RoboCup 2010

FLL Robot Design Workshop

INSTALLATION INSTRUCTIONS ATV PLOW Mount Kit: PN Application: Sportsman 400, Magnum 425

Structure Design of a Feeding Assistant Robot

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

PLEASE CHECK ALL BOXES FOR HARDWARE BEFORE DISCARDING WARRANTY AND USER INFORMATION CAN BE FOUND AT THE END OF THESE INSTRUCTIONS

Transcription:

2013 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) November 3-7, 2013. Tokyo, Japan Development of a Walking Support Robot with Velocity-based Mechanical Safety Devices* Yoshihiro Kai Abstract Safety is one of the most important issues in walking support robots. This paper presents a walking support robot equipped with velocity-based mechanical safety devices. The safety devices consist of only mechanical components without actuators, controllers, or batteries. The safety device is attached to each drive-shaft of the robot. If the safety device detects an unexpected angular velocity of the drive-shaft, the safety device can switch off all motors of the robot and lock the drive-shaft. The safety devices can work even if the robot s controller does not work. Firstly, we describe the characteristics of the safety device. Secondly, we explain the walking support robot and the structure and mechanism of the safety device. Thirdly, we show the walking support robot which we developed. Finally, we experimentally verify the effectiveness of the safety device. I. INTRODUCTION In Japan, the number of aged people is rapidly increasing [1]. It is expected that elderly patients who need gait rehabilitation will increase. In hospitals, walking support robots are needed that can support the gait rehabilitation of patients in order to decrease caregivers burdens and to increase patients independence [2]-[4]. Many researchers have developed various kinds of walking support robots [5]-[7]. These robots can realize many functions for supporting the gait of elderly people by controlling some actuators. However, the robots will move unintentionally and be dangerous robots for users, if their controllers do not work. Therefore, a walking support robot with hardware-based safety devices would be desirable to guarantee safety even if the controller breaks down. Emergency switches are often used as hardware-based safety devices [8], [9]. When the robot s controller does not work, emergency switches are useful for stopping the robot. However, the patients and/or the caregivers may not be able to push the emergency switch in case of emergency. In this paper, we present a walking support robot with hardware-based safety devices. The safety devices consist of only mechanical components without actuators, controllers, or batteries. We call the safety device velocity-based mechanical safety device. The safety device is attached to each drive-shaft of the robot. If the safety device detects an unexpected robot motion on the basis of the drive-shaft s angular velocity, the safety device can switch off all motors of the robot and lock the drive-shaft. The safety devices can work even if the robot s controller does not work. *This work was partially supported by NSK Foundation s Research Grant for the Advancement of Mechatronics. Yoshihiro Kai is with the Department of Mechanical Engineering, Tokai University, Kanagawa 259-1292, JAPAN;(kai@tokai.ac.jp) This paper is organized as follows. In section II, we describe the characteristics of the safety device. In section III, we explain about the walking support robot equipped with the safety devices, especially about the structure and mechanism of the safety device. In section IV, we show the walking support robot which we developed. In section V, we present experimental results to verify the effectiveness of the safety device. Section VI concludes this paper. II. CHARACTERISTICS OF VELOCITY-BASED MECHANICAL SAFETY DEVICE The characteristics of the mechanical safety device are as follows: (i) If the angular velocity of a drive-shaft (hereinafter referred to as shaft ) exceeds a preset threshold level, then the safety device for the shaft is activated. We call the preset threshold level detection velocity level. (ii) The detection velocity level is adjustable. (iii) After detecting the unexpected robot motion on the basis of the angular velocity, the safety device switches all motors of the robot off. (iv) After switching off all motors, the safety device locks the shaft in order to reduce the risk of collision between the robot and humans (e.g. patients or caregivers). (v) The lock of the shaft is released by rotating the shaft in a direction opposite to the direction in which the safety device locks the shaft. (vi) The safety device consists of only passive components without actuators, controllers, or batteries. By the above characteristics (i), (iii) and (iv), we can expect that the safety device prevents high-speed collision between the robot and humans (see Fig. 1). Furthermore, by (ii), we can adjust the detection velocity level according to the requirement of each patient s gait exercise. Additionally, by (v), if a human is pressed against a wall by the robot locked by High Speed Walking Support Robot Patient Walking Support Robot Patient Lock (With no Safety Devices) (With Safety Devices) Figure 1. Unexpected High Speed Robot Motion 978-1-4673-6357-0/13/$31.00 2013 IEEE 1125

Human (e.g. Patient or Caregiver) Wall Wall Armrest Force Sensor Figure 2. Rescue of a Human Pressed against a Wall by the Robot Drive Unit Drive Unit Batteries are Dead Batteries are Dead Lock Caster Figure 4. Walking Support Robot Proposed in this Paper Slope Slope (With no Safety Devices) (With Safety Devices) Figure 3. Case Where Robot Batteries are Dead Velocity-based Mechanical Safety Device the safety device, we can easily rescue the human by moving the robot in a direction opposite to the direction in which the human is pressed (see Fig. 2). Finally, by (vi), even if the batteries in the robot are dead, the safety device can act because it requires no power supply (see Fig. 3). III. WALKING SUPPORT ROBOT WITH VELOCITY-BASED MECHANICAL SAFETY DEVICES Fig.4 shows the walking support robot with velocity-based mechanical safety devices. The walking support robot has two drive units, two casters, and a force sensor. The force sensor is installed between the armrest and the body of the robot. Fig. 5 shows the drive unit. Each drive unit has a motor with an encoder and the motor torque is transmitted to Wheel via Gear 1-A, Gear 1-B, Shaft A, Gear 1-C, Gear 1-D, and Shaft B. The robot can move by controlling the two motors on the basis of the force sensor signals and the encoder signals. In order to lock Shaft A in clockwise and counterclockwise directions, each drive unit has two velocity-based mechanical safety devices (that is, one safety device for locking in the clockwise direction and another safety device for locking in the counterclockwise direction). Wheel Wheel Shaft B (i) Perspective View Shaft A Gear 1-B Gear 1-C Gear 1-D Motor Velocity-based Mechanical Safety Device Gear 1-C Gear 1-A Motor A. Structure of the Velocity-based Mechanical Safety Device Fig. 6 shows the structure of the safety device. Gear A, Plate B and Ratchet Wheel A are attached to Shaft A. Claw B is attached to Plate B by Pin D. Guide Bar B attached to Claw B is inserted in Guide Hole B of Plate A. Shaft A rotates Plate A via the Torsion Spring. One end of Linear Spring A is connected to Pin B attached to, and another end is connected to Pin A of Frame B. has inner teeth. Guide Bar A attached to is inserted to Guide Hole A of Plate C. Gear B meshes with Gear A. Rotary Damper is connected to Gear B. Claw A is connected to the shaft of Rotary Damper. (ii)top View Figure 5. Drive Unit One end of Linear Spring B is connected to Claw A, and another end is connected to Frame A. Frame A is mounted on Frame B. Switch A which can interrupt electric power supply to all motors of the robot is installed at the position of being pressed by Pin C when is rotated. Fig. 7 shows the details of Plate A. The ratchet teeth portion is connected to the plate portion via a spring. 1126

2) Shaft-lock Mechanism Fig. 9 shows the mechanism to mechanically lock Shaft A. After Plate A is locked, Claw B slides along Guide Hole B of Plate A by the rotation of Plate B and contacts with the inner teeth of, as shown in Fig. 9(b). After contacting with the inner teeth, Claw B is hooked to the inner teeth and rotates (Fig. 9(c)). By the rotation of, Pin C switches off and moves along Guide Hole A (Fig. 9(d)). After that, meshes with Ratchet Wheel A and thus Shaft A is locked. Figure 6. Structure of the Mechanical Safety Device (a) Figure 7. Details of Plate A B. Mechanism of the Velocity-based Mechanical Safety Device 1) Velocity-based Detection Mechanism Fig. 8 shows the mechanism which mechanically detects the unexpected robot motion on the basis of the angular velocity of Shaft A. The damping torque by Rotary Damper and the spring torque by Linear Spring B act on Claw A, when Gear B is rotated by Gear A. As the velocity of Gear A (i.e. Shaft A) increases, the damping torque increases. Claw A rotates by the torque difference between the damping torque and the spring torque, and locks Plate A, if the velocity of Shaft A exceeds the detection velocity level. The detection velocity level is adjustable by using an adjustment mechanism of detection velocity level, which is shown in 4). (b) (c) Torque Difference between Damping Torque and Spring Torque Figure 8. Velocity-based Detection Mechanism (d) Figure 9. Shaft-lock Mechanism 1127

Ratchet Wheel A Patient Direction Locked by Safety Device Line 2 Claw B 2 Line 1 Shaft A Line 1 Line 2 Claw B 2 Line 2 Line 1 Lock of Shaft A Claw B_1 Line 2 Claw B 3 Line 1 Inner Teeth (a) (b) Figure 12. Mechanism using Multiple Claws B Guide Hole A After Shaft A is locked, the damping torque acting on Claw A becomes zero. However, if the patient provides a force to the robot in the direction locked by the safety device (see Fig. 10), the lock of Shaft A is kept by meshing between Ratchet Wheel A and. The lock of Shaft A is released by moving the robot to the inverse direction. After the lock of Shaft A is released, even if the patient leans on the robot again and the robot moves, the safety device can stop the robot when the robot s velocity exceeds the detection velocity level because the safety device requires no power supply. 3) Mechanism using Multiple Claws B and Multiple Claws C In the above mechanism, it is preferred that the rotation angle of Claw B is as short as possible after Claw B contacts with the inner teeth of, because an increase in the angle increases the risk of collision between the robot and humans. Also, in order to be reliably meshed with Ratchet Wheel A and even if Claw B is hooked to any tooth of the inner teeth, it is necessary that the teeth number of Ratchet Wheel A is a multiple of the number of inner teeth of (see Fig. 11). As a method for shortening the rotation angle of Claw B, we can propose increasing the number of inner teeth on and the number of teeth on Ratchet Wheel A. However, there are limitations on increases in the number of inner teeth on and the number of teeth on Ratchet Wheel A, because the safety device installed to the walking support robot is required to be as compact as possible. Ratchet Wheel A Inner Teeth Claw B Figure 10. Lock of Shaft A Inner Teeth Ratchet Wheel A Claw B Geometrical Relationships are Always Same When Claw B is Hooked to Inner Teeth of. Figure 11. Geometric Relation between Ratchet Wheel A and Ratchet Wheel A Figure 13. Mechanism using Multiple Claws C In the following, first, we explain a mechanism using some Claws B. By using some Claws B, the mechanism provides the same advantage as when the number of inner teeth on is increased. Fig. 12 illustrates the mechanism in which three claws are used. Each claw is positioned as shown in Fig. 12(a). Lines 1, 2 and 3 trisect each tooth of the inner teeth. If Claw B_1 does not mesh with one of the teeth at the moment of contact, only with the movement of Claw B_2 by one third of the tooth length, Claw B_2 meshes and rotates (Fig. 12(b)). Note that, in this case, by using Ratchet Wheel A having three times as many teeth as the inner teeth, is reliably meshed with the Ratchet Wheel A. By using the same technique, if we use n Claws B, the mechanism provides the same advantage as when the number of inner teeth on is increased by a factor of n. Next, we explain a mechanism using some Claws C. When we increase the teeth number of Ratchet Wheel A without changing the diameter of Ratchet Wheel A, the strength of each tooth decreases because the teeth are downsized. If the diameter of Ratchet Wheel A is increased, the safety device becomes larger. Therefore, as shown in Fig. 13, we propose using some Claws C. By the rotation of, the Claws C simultaneously move along Guide Holes A and simultaneously mesh with Ratchet Wheel A. We expect that the force applied to each tooth of Ratchet Wheel A will decrease in proportion to the number of Claws C because the Ratchet Wheel A is simultaneously locked by Claws C. 4) Adjustment Mechanism of Detection Velocity Level Fig. 14 shows the adjustment mechanism of detection velocity level. As shown in Fig. 14, the detection velocity level is adjustable by changing the attachment position of Linear Spring B by using two nuts. If the mass and moment of inertia of Claw A are so small that we can neglect the inertial torque and the gravitational torque, we can obtain the motion equation of Claw A as the following equation: 1128

Linear Spring B Frame A Nut Nut Bolt x r Plate A Adjustment Shaft A Mechanism Claw A Gear A Gear B Rotary Damper (a) Low Linear Spring B Bolt Nut Nut x Adjustment Mechanism r (b)high Figure 14. Adjustment Mechanism of Detection Velocity Level cω s = kr x, (1) where c is the damping coefficient of Rotary Damper, ω is the detection velocity level, s is the gear ratio of Gear A to Gear B, k is the spring constant of Linear Spring B, r is the distance between the shaft axis of Rotary Damper and the attachment position of Linear Spring B, and x is the displacement from the natural length of Linear Spring B. From (1), the detection velocity level is represented as kr x ω=. (2) cs We can approximately set the detection velocity level by using (2). IV. DEVELOPED WALKING SUPPORT ROBOT We developed the walking support robot equipped with four velocity-based mechanical safety devices. In each safety device, three Claws B and four Claws C were used. Fig. 15 shows the developed robot. As shown in Fig. 15, the length and width are 125[cm] and 154[cm], and the armrest is adjustable in height from 85[cm] to 108[cm] according to the height of the patient by using a hand crank. V. EXPERIMENT AND DISCUSSION We experimentally examined whether the developed safety device can achieve the function. Fig. 16 shows the experimental setup. We set the walking support robot on the two rollers and the two spacers, as shown in Fig. 16. Further, we attached some markers on Gear A (i.e. Shaft A) and Claw A of the safety device 1, then measured the velocity of Shaft A and the motion of Claw A by using a motion capture system (HAS-500, DITECT Corporation) while increasing the velocity of Shaft A by the motor. The sampling frequency of the motion capture system was 200[Hz]. We experimented using detection velocity levels of 1.11, 1.70, and 2.14 [rad/s], which were set by using (2). The number of trials was 5 for each detection velocity level. Figs. 17, 18, and 19 show the typical examples of the experimental results for the detection velocity levels of 1.11, 1.70, and 2.14 [rad/s]. In each figure, the time when Claw A locked Plate A is indicated by an arrow. Fig. 17 indicates that the velocity of Shaft A was approximately the detection velocity level at the time when Claw A locked Plate A. Furthermore, Fig. 17 indicates that the velocity of Shaft A ultimately became zero. Figs. 18 and 19 also indicate the similar results to Fig. 17. Table I shows the average value and standard deviation of the Shaft A s velocities which were measured at the time when Claw A locked Plate A, for each detection velocity level. From Figs. 17-19 and Table I, we consider that Claw A locked at the time when the Shaft A s velocity approximately became the detection velocity level. Additionally, we consider that the safety device locked Shaft A after that, because the Shaft A s velocities ultimately became zero in all the experimental results. Therefore, we can conclude the safety device achieved the function. Hand Crank Armrest Safety Device 4 Safety Device 3 Rollers Developed Walking Supprot Robot Spacers Safety Device 2 Safety Device 1 Motion Capture System Figure 15. Developed Walking Support Robot Figure 16. Experimental Setup 1129

TABLE I. EXPERIMENTAL RESULTS (DETECTION VELOCITY) Detection Velocity Level[rad/s] (Setting Velocity) Average[rad/s] Standard Deviation [rad/s] 1.11 1.04 0.04 1.70 1.72 0.06 2.14 2.22 0.12 The time when Claw A locked Plate A(0.26[s]) Figure 17. Experimental Result for Detection Velocity Level of 1.11[rad/s] VI. CONCLUSION In this paper, we presented a walking support robot equipped with velocity-based mechanical safety devices. We described the characteristics of the safety device. Additionally, we explained the walking support robot and the structure and mechanism of the safety device. Furthermore, we showed the walking support robot which we developed. Finally, we verified the effectiveness of the safety device by experiments. In the future, we will examine the usefulness of the safety device in more detail. ACKNOWLEDGMENT The author would like to thank to the former and current students of Kai laboratory in Tokai University for their efforts in obtaining the results reported in this paper. The time when Claw A locked Plate A(0.35[s]) Figure 18. Experimental Result for Detection Velocity Level of 1.70[rad/s] The time when Claw A locked Plate A(0.31[s]) Figure 19. Experimental Result for Detection Velocity Level of 2.14[rad/s] REFERENCES [1] Cabinet Office, Government of Japan, Annual Report on the Aging Society: 2010 (Summary), Cabinet Office Japan, 2011, pp.2-5. [2] T. Tani, A. Koseki, A. Sakai, S. Hattori, System Design and Field-testing of the Walking Training System, in Proc. of the 1996 IEEE/RSJ International Conference on Intelligent Robots and Systems, Vol.1, pp.340-345, 1996. [3] T. Tanioka, Y. Kai, T. Matsuda, Y. Inoue, K. Sugawara, Y. Takasaka, A. Tsubahara, Y. Matsushita, I. Nagamine, T. Tada and F. Hashimoto, Real-time Measurement of Frozen Gait in Patient with Parkinsonism Using a Sensor-controlled Walker, The Journal of Medical Investigation, Vol.51, pp.108-116, 2004. [4] Y. Kai, T. Tanioka, Y. Inoue, T. Matsuda, K. Sugawara, K. Ishida and H. Yamamoto, Prevention of a Patient s Falling by Using a Sensor Controlled Ambulation Support Machine : Analysis of Leg Muscle Action Based on the Musculo-skeletal Model, in Proc. of the First Asian Conference on Multibody Dynamics, pp.86-96, 2002. [5] T. Tani, A. Koseki, A. Sakai, S. Hattori, Control Methods of Walk Training System, JSME Int. J., Series C, Vol.40, No.2,pp.285-290, 1997. [6] K. Miyawaki, T. Iwami, G. Obinata, Y. Kondo, K. Kutsuzawa, Y. Ogasawara, and S. Nishimura, Evaluation of the Gait for Elderly People Using an Assisting Cart (Gait on Flat Surface), JSME Int. J.,Series C, Vol.43, No.4, pp.966-974, 2000. [7] J. Lee, C. Lee, Development of Walking Assistance Robot System and Experiment with the Disabled, in Proc. of SICE/ICASE Workshop, pp.219-224, 2001. [8] Y. Nemoto, S. Egawa, A. Koseki, S. Hattori, T. Ishii, M. Fujie, Power assisted Walking Support System for Elderly, in Proc. of the 20th Annual Int. Conf. of the IEEE Eng. in Medicine and Biology Soc., Vol. 20, No. 5, pp. 2693-2695, 1998. [9] Y. Kai, T. Tanioka, Y. Inoue, T. Matsuda, K. Sugawara, Y. Takasaka and I. Nagamine, A Walking Support/Evaluation Machine for Patients with Parkinsonism, The Journal of Medical Investigation, Vol. 51, pp.117-124, 2004. 1130