Operating Instructions for ISSI Series LM2X, LM2X-DM, LM2X-DMHP

Similar documents
JAWIRA TIMUR SDN. BHD.,

Application Note 26. Optical Hazard Measurements with JETI specbos 1211UV

TEST REPORT IEC Photobiological safety of lamps and lamp systems

TEST REPORT IEC and/or EN Photobiological safety of lamps and lamp systems

Measurement overview

ISO INTERNATIONAL STANDARD. Ophthalmic instruments Fundamental requirements and test methods Part 2: Light hazard protection

The Issues of Measurement of Optical Hazard Using Photometers EMRP JRP ENG05 Metrology for Solid State Lighting

Laser processing of materials. Laser safety

LXE300. Four Mounting Holes on Base. Compliant IEC. Warranty

LM45 MULTI-DRIVE TM. Miniature Mini LINEAR L IGHT IP 65 PRODUCT HIGHLIGHTS. RoHS YEAR. smartvisionlights.com. Compliant CE. Warranty.

LXE Mounting Holes on Base. Warranty. Compliant IEC. Brightest linear light yet, delivering up to 100,000 lux in OverDrive mode

REPORT OF CALIBRATION of One Standard of Spectral Irradiance ( nm)

Safety Issues of the Baseband IR PHY

Broadbandradiometer specbos 1211

Oriel Flood Exposure Sources

4.2W 445nm Laser Diode Component

Fiber Coupled Laser Sources

LINEAR LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

Analysis and Measurements of Artificial Optical Radiation (AOR) Emitted by Lighting Sources Found in Offices

Diode Pointer Quick Start Guide

Laser Safety & the Human Eye Recall the human eye is a simple single lens system Crystalline lens provide focus Cornea: outer surface protection

RM75. Miniature Mini IP 50 RING LIGHT LOW-ANGLE MULTI-DRIVE TM PRODUCT HIGHLIGHTS 5-PIN M12. RoHS YEAR. smartvisionlights.com. Compliant CE.

Compact High Intensity Light Source

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

TECHNICAL INFORMATION GoldPanther Forensic Light Source Kit (Patent Pending) Cat. Nos. FAL2000, FAL

Basic concepts. Optical Sources (b) Optical Sources (a) Requirements for light sources (b) Requirements for light sources (a)

EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES

CBT-120-UV LEDs. CBT-120-UV Product Datasheet. Features: Table of Contents. Applications

Statement on ICNIRP guidelines on limits of exposure to incoherent optical radiation

TECHNICAL REPORT. Safety of laser products. Sécurité des appareils à laser

Contact person Date Reference Page Stefan Källberg MTt6F (4) Measurement Technology

NON-AMPLIFIED PHOTODETECTOR USER S GUIDE

Biological impact of optical radiation from curing lights

3/4 turn pot Intensity control of 10% to 100% Clockwise increases intensity Analog Intensity

Statement on ICNIRP guidelines on limits of exposure to laser radiation

Typical LED Characteristics

Diode Pointer Quick Start Guide

L4 Series Operator Manual

High Power Pulsed Laser Diodes 850-Series

BTM Series Pulsed RF Power Amplifier Modules. Application Note

HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

Description. Kingbright

Series 48 Water Cooled Laser & UC-2000 Quick Start Guide

Winter College on Optics: Trends in Laser Development and Multidisciplinary Applications to Science and Industry February 2013

Descriptions. Kingbright

Bridgelux Vesta Series Tunable White 9mm Array. Product Data Sheet DS152

LASER RADIATION REQUIREMENTS

Bridgelux Vesta Series Dim-To-Warm 9mm Array. Product Data Sheet DS150

Firestar v Series air cooled laser & Flyer 3D System Quick Start Guide

Description. Kingbright

NON-AMPLIFIED HIGH SPEED PHOTODETECTOR USER S GUIDE

T-1 3/4 (5mm) FULL COLOR LED LAMP. Features. Descriptions. Package Dimensions

ISO INTERNATIONAL STANDARD. Ophthalmic instruments Slit-lamp microscopes. Instruments ophtalmiques Microscopes avec lampe à fente

Series 48 Air Cooled Laser & UC-2000 Quick Start Guide

SPEC NO: DSAB8533 REV NO: V.19A DATE: AUG/16/2014 PAGE: 1 OF 7 APPROVED: WYNEC CHECKED:

OVSRRGBCC3 / OVSRRGBCC3TM

1.9x3.9mm RECTANGULAR SOLID LAMP. Features. Description. Package Dimensions. Part Number: WP144GDT

UC-1000 Universal Laser Controller Operation Manual

Optoelectronics Data Book

INTERNATIONAL STANDARD

CBT-90-UV-405 LEDs. CBT-90-UV-405 CBT-120 Product Datasheet. Features: Table of Contents. Applications

3.2mmx3.6mm FULL-COLOR SURFACE MOUNT LED LAMP. Descriptions. Features. Package Dimensions

Near-Infrared (NIR) Light-Emitting Diode

RMX75. Miniature Mini IP 65 RING LIGHT MULTI-DRIVE TM PRODUCT HIGHLIGHTS 5-PIN M12. RoHS YEAR. smartvisionlights.com. Warranty.

SACCADOMETER Eye surface irradiance - report version 1

Kingbright. L-7113SF6C T-1 3/4 (5mm) Infrared Emitting Diode DESCRIPTION PACKAGE DIMENSIONS FEATURES APPLICATIONS SELECTION GUIDE

Description. Kingbright

Author: Rachel Johnston, Carl Paton Date: 09/07/10 Manager: Brent Price

ICNIRP TG STATEMENT ADJUSTMENT OF GUIDELINES FOR EXPOSURE OF THE EYE TO OPTICAL RADIATION FROM OCULAR INSTRUMENTS

Full-Color 1204 SMD (150 Viewing Angle)

WP710A10F3C T-1 (3mm) Infrared Emitting Diode

Crizal UV: the new anti-reflection lens that protects against UV radiation

SURFACE MOUNT LED ULTRAVIOLET, 0603 PACKAGE

280nm LED performance information

Method of determining photobiological safety of contemporary light sources

Pulstar p100/150 water cooled laser & Flyer 3D System Quick Start Guide

UVLED SMD. Description. Maximum Ratings (T CASE = 25 C) Electro-Optical Characteristics (T CASE = 25 C, I F = 500mA)

SPEC NO: DSAF1339 REV NO: V.9B DATE: NOV/10/2015 PAGE: 1 OF 6 APPROVED:

Diode Lasers, Single- Mode 50 to 200 mw, 830/852 nm. 54xx Series

UVTOP270-SMD. Description. Maximum Ratings (T CASE = 25 C) General Characteristics (T CASE = 25 C, I F = 20mA)

WP3653SYDLK/SD/TG/J3 Oval LED Lamp

L25 Series Operator Manual

Descriptions. Kingbright

APHCM2012SURCK-F x 1.25 mm SMD CHIP LED LAMP

EXPERIMENT 3 THE PHOTOELECTRIC EFFECT

Descriptions. The Hyper Red source color devices are made with Suitable for all SMD assembly and solder process.

Description. Kingbright

Kingbright. L-7679C1QBC-D Super Flux LED Lamp DESCRIPTIONS PACKAGE DIMENSIONS

M12 P R O D U C T H I G H T L I G H T S

Descriptions. Kingbright

Descriptions. The Hyper Red device is based on light emitting diode Ideal for backlight and indicator.

SPEC NO: DSAH3723 REV NO: V.5B DATE: AUG/19/2014 PAGE: 1 OF 5 APPROVED: WYNEC CHECKED:

Description. Kingbright

SBM-120-UV. Surface Mount Series. Ultraviolet LED. SBM-120-UV Product Datasheet. Features: Table of Contents. Applications:

1. System Information.. 2. System Dimensions Emitter Specifications.. 4. RF Driver Specifications.. 5. RF Cable Specifications...

MEI. Features: Descriptions: Applications:

Uniform surface Led series SFL-UV

Biophysical Basis of Optical Radiation Exposure Limits. Bruce E. Stuck

Kingbright. L-132XGD T-1 (3mm) Solid State Lamp DESCRIPTION PACKAGE DIMENSIONS FEATURES APPLICATIONS SELECTION GUIDE

Infrared Cataract And Temperature Elevation Within The Eye. Tsutomu OKUNO

Transcription:

Operating Instructions for ISSI Series LM2X, LM2X-DM, LM2X-DMHP and LM2X-DMHP-RGB LED Modules

August 31, 2006 Rev. 1 Caution This LED illuminator is manufactured with very high power LEDs. Please be aware that eye damage can occur if the user stares into the LED illuminator at a close range. The same precautions should be followed with this LED illuminator as with any high intensity light source. 2

Table of Contents Section Page I. Description of LED Illuminators. 4 II. III. III. IV. Specifications..5 Operating instructions 1. LM2X.6 2. LM2X-DM...6 3. LM2X-DMHP..7 3. LM2X-DMHP-RGB.8 Typical waveforms 1. LM2X- 400...9 2. LM2X- 460..10 3. LM2X-DMHP-RGB.....11 Module changing instructions.12 V. Safety Notices.14

I. Description of LED Illuminators The Series LM2X illuminator is a very compact, high-output device that is capable of operating in a constant-light-output mode (DC) or gated on and off by an external signal with either DC levels or high power level with reduced duty factors. The LED illuminator is usually purchased with one of the two drive modules available. These modules are standardized to permit the operator who wishes to change operating modes from DC to high power pulse in the field with a simple change of drive modules. The change simply requires a replacement of the rear drive module with the proper drive module and connection of the appropriate power supply. The rear modules are interchangeable on all the LM2X illuminators, with exception of the RGB driver module. The LM2X illuminator consists of a LED module and one of two drive modules. The LM2X-DM drive module has a three-position locking switch for changing from continuous to dc pulsed operation. The center position is off condition. The dc pulsed operation allows the operator to turn on the LED with a TTL signal at the BNC connector. This drive module uses a 24 vdc power supply. The LM2X high power pulsed illuminator has the same front LED module, but the LM2X-DMHP drive module is a high power pulser that uses a 48 vdc power supply. The LM2X high power pulsed illuminator is capable of generating light output that is five (5) times greater peak intensity than the continuous-output illuminator. To achieve that output level the duty factor must be limited to 5%, and the maximum pulse width must be <3 ms. The LM2X has a built in safety circuit to protect the illuminator if these limits are exceeded. This module has one BNC to facilitate pulsing. The Series LM2X-DMHP-RGB series has the same duty-factor and pulsewidth limitations as the LM2X illuminator but operates at three output wavelengths (red, green and blue). Each color is independently controlled with a TTL input signal. The RGB drive module also has the safety circuit for duty-factor protection. 4

II. Specifications LM2X w/lm2x-dm Standard output wavelengths Optical output power dc DC pulsed -rise time -fall time Divergence-full angle Power-supply voltage 400nm & 460 nm > 3 W <10 µsec 150 µsec 100 degrees 24 vdc/2.5 A LM2X w/lm2x-dmhp Optical output power Pulsed -rise time -fall time Maximum pulse width Power- supply voltage >1.0 watts @ 5% duty factor < 100 nsec < 100 nsec 1.5 milliseconds 48 vdc/ 2.7 A LM2X-DMHP-RGB Wavelengths - red 625 nm - green 530 nm - blue 460 nm Pulsed -rise time < 50 nsec -fall time < 50 nsec Minimum pulse width 140 nsec Power-supply voltage 48 vdc/ 1.25A 5

III. Operating Instructions These led illuminators are extremely easy to use. There are only two parts to the light source. They consist of the led main body, driver module with power supply. The cable from the power supply is connected to the driver/led assembly and the power supply is plugged into a power source. The led illuminator is ready for operation. Series LM2X w/ LM2X-DM If the LM2X-DM is being used the power supply will be a 24 vdc / 2.5 A model. The drive module will have one three position switch on the rear housing. This switch is in the off position when it is perpendicular to the housing. To actuate the switch, lift and move to either side depending on which mode of operation you wish to use. One position is the continuous dc output mode and the other position is the pulsed dc mode which requires a +5 vdc level to be introduced into the BNC connector next to the switch. Once the switch is in the correct position it will fall into a locked positions when released. To move the switch, it needs to be pulled up to release the locking mechanism before moving to the new position. Power Input Toggle Switch BNC Input LM2X-DM Drive Module LM2X LED Module 6

Series LM2X w/ LM2X-DMHP The LM2X-DMHP uses a power supply that is 48-vdc/2.7-A model. The plugs for the two driver modules are keyed such that the power supplies are not interchangeable. The high power pulser has only one BNC connector, which is used to apply the TTL (5 vdc) signal to the illuminator. The output occurs with a +5 vdc pulse application. The drive module has a built-in safety circuit to prevent the user from exceeding the 5% duty factor and to limit the maximum pulse width to about 1.5 ms. The LED illuminator will cease to produce light output if either of these limitations is exceeded. Once the limit has been reached, the safety circuit is tripped; this circuit can be reset by reducing the input pulse width or repetition rate. Power Input BNC Trigger Input LM2X-DMHP High Power Drive Module LM2X LED Module 7

Series LM2X-DMHP-RGB This illuminator has a different front module to accommodate a different type of LED having outputs at three distinct wavelengths. The driver module has been modified from the standard driver to allow three individual trigger inputs. The three LEDS can be triggered in any order in relation to each other with a TTL (+5 vdc) input signal. This illuminator also has the safety circuit installed to protect the leds from excessive duty factor and/or pulse width. Because of the type of LEDs that are employed, this unit has a minimum pulse width of 140 nsec. The three BNC connectors are marked with the corresponding LED color. Power Input RGB Trigger Inputs 8

IV. Typical Waveform LM2x 400 1.2 1 0.8 Relative Amplitude 0.6 0.4 0.2 0 370 380 390 400 410 420 Wavelength nm Typical waveform of an LM2X 400 9

LM2x 460 1.2 1 0.8 Relative Amplitude 0.6 0.4 0.2 0 420 430 440 450 460 470 480 490 500 Wavelength nm Typical waveform of an LM2X 460 10

1.1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 RGB Spectrum 350 400 450 500 550 600 650 700 750 Wavelength nm relative amplitude Typical waveform of an LM2X-DMHP-RGB 11

IV. Module Changing Instructions The LM2X LED module has four Led quadrant plugs and a 12 vdc fan plug. These are matched to corresponding headers on each of the drive modules. LED Quadrant Plugs 12 vdc Fan Plug Mounting Posts (4 each) LM2X LED Module LED Quadrant Headers 12 vdc Fan Header LM2X-DM Drive Module 12

LED Quadrant Headers Safety Circuit 12 vdc Fan Header LM2X-DMHP Drive Module To change drive modules all that needs to be done is to loosen the two socket head set screws that are tightened on the mounting posts and slide off which ever module that is currently connected. Remove the four led quadrant plugs as well as the 12 vdc plug. Connect the quadrant plugs and the 12 vdc fan plug of the new driver module and slide the led module onto the posts and tighten the two set screws onto the mounting posts. Install the proper power supply for the module in use. The power supplies are keyed so that they cannot be used on the wrong drive module. The LED illuminator is now ready for use. As always observe the proper safety measures when using high power light sources. 13

V. Safety Notices Safe Operating Procedures for the LM2X-400 The data and recommendations contained in this document are based on Recommended Practice for Photobiological Safety for Lamps & Lamp Systems General Requirements, published by the American National Standard and prepared by the IESNA Committee. (ANSI/IESNA RP-27.1-96) This document is a general guide; the user of the LM2X-400 LED assumes all responsibility for the safe use and operation of the device. The overall recommendation is that the use of safety goggles is recommended to prevent the possibility of damage to the eyes. The safe working distance, defined as the distance at which continuous exposure to the lamp will not exceed the recommended danger level, for a singe lamp is 13-cm. Note that the use of multiple lamps will increase this distance. Exposure Limits for LM2X-400 LED Personnel working with or in the vicinity of the LM2X-400 LED should not be exposed to levels exceeding the following limits. Ultraviolet Exposure Limits Exposure limits for ultraviolet extend from 200-nm to 400-nm, just on the boundary of the operation of this lamp. The peak region for UV hazard is centered near 270-nm, a region where this lamp has no content. The spectral content of a LM2X-400 LED is shown in Figure 1. The peak wavelength is near 397-nm and the FWHM is approximately 20-nm. The distribution of radiation at a distance of 76-cm (30-inches) is shown in Figure 2 and the radiation along the centerline as a function of distance is shown in Figure 3. The Effective Ultraviolet Irradiance is calculated using the spectra in Figure 1 and: 400 E S E S (1) 200 E S is the Effective Ultraviolet Irradiance in W cm -2 E λ is the Spectral Irradiance in W cm -2 nm -1 S(λ) is the hazard weighting function (Table 2, ANSI/IESNA RP-27.1-96) Δλ is the bandwidth in nm The permissible time per day for exposure to ultraviolet radiation upon the unprotected eye or skin is computed using: 0.003 t max (2) E S The spectral irradiance at the exit plane of the LM2X was measured as 32- mw cm -2. To simplify the analysis, all radiation from the lamp is assumed to be at 395-nm and therefore, the value of S(λ) at 395-nm (from Table 2 ANSI/IESNA 14

RP-27.1-96) is 0.000036. Using this information and equation 1, a value for E S of (1.2 10-6 ) is computed. Using this result and equation 2, the maximum exposure time per day is ~43 minuets. Note that this assumes the user has placed his/her skin or eye at the exit plane of the lamp. To determine safe operation, the peak irradiance as a function of working distance is plotted in Figure 3. This plot was converted to maximum exposure time as a function of distance as demonstrated above using, equation 1, and equation 2. The maximum exposure time for a single lamp as a function of distance is plotted in Figure 4 (black circles). From this figure, the recommended safe operating distance for ultraviolet exposure for the LM2X-400 lamp is 13-cm. Note that the use of multiple lamps will increase the spectral irradiance at a given distance and thus decrease the maximum allowable exposure time at that distance. Plots of the maximum exposure time as a function of distance for multiple lamps are also included in Figure 4. Regardless of the operating conditions, the use of UV safety glasses is recommended. Light and Near Infrared Radiation Exposure Limits Exposure limits for ultraviolet extend from 400-nm to 1400-nm. These limits apply for exposure within any 8-hour period. Retinal Thermal Hazard Exposure Limit To protect against retinal thermal injury, the integrated spectral radiance of the light source, L R, weighted by the burn hazard weighting function R(λ) (From Table 3, ANSI/IESNA Rp-27.1-96) should not exceed levels defined by: L R 1400 5 L R 400 (4) 0. 25 t L R is the burn hazard weighted radiance of the light source in W cm -2 sr -1. L λ is the spectral radiance in W cm -2 sr -1 nm -1. R(λ) is the burn hazard weighting function (Table 3, ANSI/IESNA RP-27.1-96) Δλ is the bandwidth in nm. α is the angular subtense of the source in radians defined b the 50 percent peak radiance points. If the calculation of α exceeds 0.1 radian, use 0.1 radian in equation 4. No criteria for thermal hazard are relevant for exposure durations longer than 10 seconds, because while thermal injury is the dominant injury mechanism to 10 seconds, photochemical mechanisms predominate for exposure durations longer than 10 s. Finally, note that the burn hazard is minimal at 400-nm and peaks near 440-nm. For this calculation we have used the worst case model of an exposure of 10 seconds and α of 0.1 radian. The half maximum in Figure 1 is near 415-nm, we will simply use a burn hazard function of 10 for all wavelengths to predict the maximum burn hazard. With these assumptions, LR equals 1.9 while the lower limit on LR is 28.1. From this we conclude that the LM2X poses no burn hazard. 15

Retinal Blue Light Hazard Exposure Limit To protect against retinal photochemical injury from chronic blue-light exposure, the integrated spectral radiance of the light source weighted against the blue-light hazard function (Table 3, ANSI/IESNA RP-27.1-96) should not exceed levels defined by: 700 4 t L B t 100 for t 10 L B (5a) 400 700 400 4 0.1 for t 10 L B L B (5b) L B is the blue light weighted radiance in W cm -2 sr -1. L λ is the spectral radiance in W cm -2 sr -1 nm -1. B(λ) is the blue light hazard weighting function (Table 3, ANSI/IESNA RP-27.1-96) Δλ is the bandwidth in nm. t is the exposure duration in seconds. For a weighted source exceeding 10-mW cm -2 sr -1, the maximum possible exposure duration, t(max), is 100 t max (6) The spectral radiance at the exit plane of the LM2X was measured to be 32-mW cm - 2 sr -1. Since this exceeds the 10-mW cm -2 sr -1 limit equation 6 is used to compute t(max). Again, a worst case estimate is made by assuming that all radiation form the LM2X is at 435-nm, the peak sensitivity for blue light hazard (Note from Figure 1 that the LM2X has little content beyond 415-nm). Making these assumptions yields a maximum exposure duration of 3125 seconds (52 min.). Again, this estimate assumes that the user has placed his/her eye at the exit plane of the lamp. A careful integration of equation 5b using Figure 1 and the data from Table 3 of ANSI/IESNA RP-27.1-96 yields a limit on the maximum exposure time of 4 hours. Finally, using the peak radiance as a function of distance from Figure 3, a curve for the maximum exposure time for blue light hazard as a function of distance is produced. These curves are very similar to Figure 4 however; the limits are less restrictive than those for UV hazard. The recommended safe operating distance for Blue Light Hazard for the LM2X-400 lamp is 5-cm. Note that the limit for UV exposure in the preceding section is more restrictive and therefore this limit is followed. The recommended safe operating distance for Blue Light Hazard for the LM2X-400 lamp is 13-cm. Infrared Radiation Hazard Exposure Limit To avoid thermal injury of the cornea and possible delayed effects upon the lens of the eye, ocular exposure to infrared radiation, E IR, over the range 770-nm to 3000-nm should be limited to 0.01 W cm -2 for periods exceeding 1000 seconds. This can be expressed as: 3000 E 770 L B E IR 0.01 for t 1000 (9a) For exposures of less than 1000 seconds the irradiance limit should be: 16

E IR 3000 0.75 E 1.8 t for t 1000 (9b) 770 E IR is the ocular exposure to infrared radiation in W cm -2. Δλ is the bandwidth in nm. t is the exposure duration in seconds. The LM2X-400 has no significant content beyond 450-nm and therefore, the LM2X-400 does not present an infrared radiation hazard. Figure 1: Spectral content of a LM2X-400. 17

Figure 2: Distribution of radiation at 76-cm (30-inches) for an LM2X-400. Figure 3: Spectral Irradiance as a function of distance along centerline of an LM2X-400 18

Figure 4: Maximum recommended exposure time limit as a function of distance for an LM2X-400. Note that use of multiple lamps increases the safe working distance. 19