Corrosion-Resistant Coated Dowel Bars

Similar documents
Section 914. JOINT AND WATERPROOFING MATERIALS

PERFORM WITH PRECISION WELDED DOWEL ASSEMBLY LOAD TRANSFER PRODUCTS CONCRETE CONSTRUCTION SOLUTIONS BROCHURE

4.1. Foremen 4.2. Concrete plant manager 4.3. Concrete plant operator 4.4. Personnel performing saw cutting and joint sealing

IGGA Guide Specification: Dowel Bar Retrofit (DBR) Introduction

A. Extent of structural precast concrete work is shown on drawings and in schedules.

B. Installation Instructions. Provide installation instructions, including any special equipment, to address the following.

AMENDMENTS Manual of STANDARD SPECIFICATIONS. Adopted by Standard Specifications Committee. Amendment. No. 6. Published by

Dowel Basket Standardization

Dowel Bar Alignment and Location for Placement by Mechanical Dowel Bar Insertion

To: New York State Department of Transportation ENGINEERING INSTRUCTION. Approved:

SECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Barofor Round System (polyester coated) Panels, Posts, Accessories

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 2007 EDITION

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

Double Bar Plate Dowels for Saw-Cut Contraction Joints

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

SECTION METAL FABRICATIONS

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

MIL-STD-883H METHOD ULTRASONIC INSPECTION OF DIE ATTACH

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

C. For cold-applied tape, the pavement temperature shall be at least 70 F.

Dowel Bar Standardization. NC^2 Fall Meeting St. Louis, MO

Special Provision No. 999F29 March 2018 REQUIREMENTS FOR INSTALLATION OF METALLIC DOWELS INTO CONCRETE

Dowel Bar Standardization. NC^2 Spring Meeting Savannah, GA

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

Special Provision No. 904S14 October OPSS 904, January 1995, Construction Specification for Concrete Structures, is amended as follows:

Standard Specifications

RR-F-191/1D 14 May SUPERCEDING RR-F-191/1C July 22, 1981 FEDERAL SPECIFICATION SHEET

Government Recognized Export House OHSAS 18001:2007 ISO 14001:2004 PED Approved Company.

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

Special Provision No. 999S29 May 2010

1. ANSI/ASME Standard B , Square and Hex Bolts and Screws, Inch Series

ARTICLE 28 VISUAL EXAMINATION STANDARDS

prepared by Tom Burnham, Co-Chair Minnesota Department of Transportation Mark B. Snyder, Co-Chair Engineering Consultant for National Concrete

Engineering Policy & Procedure

DETAIL SPECIFICATION WIRE STRAND, NONFLEXIBLE, FOR AIRCRAFT APPLICATION

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

ALLOY STEEL SOCKET SET SCREWS 1

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

Securifor Polyester Coated Welded Mesh Panels

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

TEST PROCEDURE FOR DYNAMIC PULL-OFF PERFORMANCE OF ROOFING FASTENER HEADS OR FASTENERS WITH BEARING PLATES

Evaluation of In-Pavement Light Fixture Designs and Performance

Listing Report: AB Reissue Date: 01/21/16 This report is subject to annual review

Glass Fiber Reinforced Polymer (GFRP) Dowel Bars - Aslan 600

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

SECTION PRECAST CONCRETE STRUCTURES

SECTION BULLET- RESISTANT DOORS

14 March 2016 City Hall Station Renovations Bid Documents 15 th Street Station Phase Station Improvements SECTION PRECAST CONCRETE

AWS C3.9M/C3.9:2009 An American National Standard. Specification for Resistance Brazing

Session 8: Load Transfer Restoration. (Dowel Bar Retrofit, Cross-Stitching, and Slot Stitching)

PAGE 12 : THREAD MEASUREMENT TECHNIQUE (Plated and unplated thread gauges)

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

AS Australian Standard STEEL WIRE FOR TENDONS IN PRESTRESSED CONCRETE. This is a free 5 page sample. Access the full version online.

CVO/169897A OCTOBER 29, GROUT

TECHNICAL MANUAL. TERADOWEL and ULTRADOWEL. Reliable Dowel System for Floor Joints

SECTION ARCHITECTURAL PRECAST CONCRETE PART 1 - GENERAL

2016 AASHTO BRIDGE COMMITTEE AGENDA ITEM: 24 (REVISION 1) SUBJECT: LRFD Bridge Design Specifications: Section 6, Various Articles (2)

M-RAIL Sismet Road, Mississauga, L4W 1V6 TEST REPORT FOR MLEVEL GUARD SYSTEMS

Specification

SECTION TRACER WIRE FOR NONMETALLIC PIPE

UNDERGROUND UTILITY TRENCHES AND VAULTS Page 1 of 6 ADDENDUM #1

Standard Recommended Practice. High-Voltage Electrical Inspection of Pipeline Coatings

MATERIAL SPECIFICATION FOR PACKAGED SILICA FUME DRY GROUT MIXTURE FOR POST TENSIONING

Woven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out.

Trusted ICC ES. Issued 06/2018 HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

PROCESS SPECIFICATION SURFACE FINISH REQUIREMENTS

1. Architectural precast concrete cladding units.

Standard Specification for Carbon and Alloy Steel Nuts [Metric] 1

UNIFIED FACILITIES GUIDE SPECIFICATIONS

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

eco-shake INSTALLATION INSTRUCTION

Annexure - V. Specifications, Typical Drawing & Data Sheet for Split TEE (Hot Tapping Material)

RADIOGRAPHIC EXAMINATION PROCEDURE

10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS

3400 Tectura Designs Precast Concrete

712 - STRUCTURAL STEEL CONSTRUCTION SECTION 712 STRUCTURAL STEEL CONSTRUCTION

SECTION ARCHITECTURAL PRECAST CONCRETE

PIP STF05121 Anchor Fabrication and Installation Into Concrete

SUBMITTAL SHEET. Project Submittals by

OSE Submittal July 20, 2018

Plate Dowels. An Innovation Driven by Industrial Concrete Paving. Introduction

REPORT HOLDER: SFS INTEC 1045 SPRING STREET WYOMISSING, PENNSYLVANIA EVALUATION SUBJECT:

Design and Construction Standards SECTION ATHLETIC LOCKERS

SPECIFICATION FOR WATERBORNE TRAFFIC LINE PAINT

PERFORMANCE SPECIFICATION GLASS BEADS: FOR CLEANING AND PEENING

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

PCCP Preservation Steps to Take to Extend Pavement Life and Performance of Your Concrete Pavements

Construction Specification for Watermain and Water Service Tracer Wire

NORMATIVE REFERENCES

SECTION HELICAL PILES AND HELICAL ANCHORS

COMMERCIAL ITEM DESCRIPTION RODS, GROUND (WITH ATTACHMENTS)

Multi-Set II Drop-In Anchors

ICC-ES Evaluation Report

TEST PROCEDURE FOR DYNAMIC PULL-THROUGH PERFORMANCE OF ROOFING MEMBRANES OVER FASTENER HEADS OR FASTENERS WITH METAL BEARING PLATES

Transcription:

Standard Specification for Corrosion-Resistant Coated Dowel Bars AASHTO Designation: M 254-06 (2010) American Association of State Highway and Transportation Officials 444 North Capitol Street N.W., Suite 249 Washington, D.C. 20001

Standard Specification for Corrosion-Resistant Coated Dowel Bars AASHTO Designation: M 254-06 (2010) 1. SCOPE 1.1. This specification covers the materials, manufacture, and installation of coated dowel bars to be used where corrosion-resistant performance is essential and may be used in lieu of stainless or other approved noncorrosive metals. The dowel shall consist of a steel core covered by an organic coating. 1.2. The coated dowels shall be one of the two three following types: Type A The coating material develops sufficiently low-bond strength with concrete that a bond breaker is not required. Type B The coating material develops bond strength with concrete such that a bond breaker is required. The type of bond breaker used shall be as recommended by the coating manufacturer. Type C- The coating material meets higher performance criteria for longer life pavements such as Abrasion Resistant overcoat (ARO) and develops bond strength with concrete such that a bond breaker is required. The type of bond breaker used shall be as recommended by the coating manufacturer. Formatted: Body Text 1.3. The values stated in SI units are to be regarded as the standard. 2. REFERENCED DOCUMENTS 2.1. AASHTO Standards: M 255M/M 255, Steel Bars, Carbon, Hot-Wrought, Special Quality, Mechanical Properties T 253, Coated Dowel Bars 2.2. ASTM Standard: G 12, Standard Test Method for Nondestructive Measurement of Film Thickness of Pipeline Coatings on Steel A 615 Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement A 775 Standard Specification for Epoxy-Coated Steel Reinforcing Bars A 934 Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars 2.3. Other References: FHWA-RD-74-18, Nonmetallic Coating for Concrete Reinforcing Bars, 1974 Society for Protective Coatings Specifications: SSPC-PA2 Measurement of Dry Coating Thickness with Magnetic Gauges Formatted: List Bullet, Indent: Left: 1.25", Adjust space between Latin and Asian text, Adjust space between Asian text and numbers Formatted: Body Text, Indent: Left: 1", Bulleted + Level: 1 + Aligned at: 1.5" + Indent at: 1.75" Formatted: Font: (Default) Times New Roman, 10 pt, Not Bold Formatted: Font: Not Bold Formatted: Font: (Default) Times New Roman, 10 pt, Not Bold Formatted: Indent: Left: 1.25", No bullets or numbering Comment [TSL1]: Industry standard TS-4g M 254-1 AASHTO

3. GENERAL REQUIREMENTS 3.1. The coated dowels shall resist corrosion and degradation caused by roadway deicing materials and normal highway debris. 3.2. The coating shall develop low-bond strengths with portland cement concrete without a bond breaker, if Type A, or with the proper bond breaker, if Type B or Type C. 3.3. The coating shall resist wear due to abrasion resulting from pavement expansion and contraction. 3.4. The coating used over the steel core shall be continuous on the lateral surface of the dowel. 3.5. Test procedures as stated herein and in T 253 shall apply to both Type A and Type B dowels. 3.6. In the event there is any change in material composition or geometrics of the joint support system, any or all parts of the dowels and assembly are subject to retesting. The frequency of qualification testing will be determined by the purchasing agency. 3.7. The processing facilities of the manufacturer and the fabricator shall be open to inspection by the agent of the purchaser at all times during the manufacturing and fabricating of the material. 3.8. A minimum of 24 14 dowel bars shall be made available for testing. Of these, a maximum of six bars may be in a basket assembly. 4. MATERIALS 4.1. The core material shall be made of steel meeting the requirements of M 255M/M 255. ASTM A 615.The grade shall be as specified by the purchasing agency. 4.2. The coating material shall be of organic composition with the exception of the pigment, which may or may not be present, and which may have an inorganic composition. Note 1 The Type B coating material may be one of the types recommended in Report No. FHWA-RD-74-18 or other types approved by the purchasing agency. Note 2 Powder for epoxy-coated bars for Type B and Type C coatings shall meet as a minimum the requirements set forth in ASTM A 775 Annex A1 Comment [TSL2]: In updated 255 Formatted: Body Text 5. DIMENSIONS 5.1. The core metal shall be 31.8-mm (1 1 / 4 -in.) diameter and 18 long or as specified by the purchasing agency. 5.2. The nonabraded thickness of the Type A coating shall be 0.64 ± 0.13 mm (25 ± 5 mils). The nonabraded thickness of the Type B coating shall be a minimum 10 mils 0.18 ± 0.05 mm (7 ± 2 mils). The nonabraded thickness of the Type C coating shall be a minimum of 10 mils. 5.3. Coating thickness shall be determined according to ASTM G 12 SSPC-PA2 or by stripping the coating from the bar. 5.4. The dowels shall be supplied to lengths and in support assemblies or baskets or loose as specified by the purchasing agency. 5.4. The thickness of the patched ends for Type C coating shall be a minimum of 8 mils. Comment [TSL3]: Per NCC recommendation Comment [TSL4]: Industry standard. Formatted: Normal TS-4g M 254-2 AASHTO

6. PHYSICAL REQUIREMENTS 6.1. The free ends of the dowels shall be saw cut and free of burrs and projections. 6.2. Dowel coatings shall be free from contamination, perforations, cracks, and holidays (pinholes not visually discernible). Checking for holidays shall be performed by the electric-resistance process. A 67.5-volt holiday detector shall be used, as recommended by the manufacturer of the test equipment, for the determination of holidays. Type B and C fusion bonded epoxy coating shall be applied per the requirements in ASTM A 775 or as specified by the purchasing agency. 6.3. Any damage that results from welding or mechanical fixation to achieve a fixed-end condition shall not extend more than 25.4 mm (1 in.) in from the weld or point of fixation. 6.4. Welding to achieve a fixed-end condition shall be sufficiently strong to maintain dowel alignment under the forces imposed by concrete placement and construction practices. 6.5. When tested in accordance with T 253, the dowel bars shall have the following properties: 6.5.1. Load Deflection The relative deflection shall not exceed 0.25 mm (0.10 in.) at the 1815-kg (4000-lb) load for any of the three specimens tested. 6.5.2. Pullout The maximum pullout load shall not exceed 1360 kg (3000 lb) for any specimens, and no specimen shall show any corrosion, tears, or perforation due to the pullout and subsequent freeze-thaw testing. 6.5.3. Abrasion The coating shall not have been worn away, perforated, or wrinkled, and none of the three specimens shall show depth or wear exceeding 70 percent of the original coating thickness. Thickness shall be determined according to Section 5.3 of this specification. Comment [TSL5]: Not needed. Standard basket detail from NCC. 6.5.4. Corrosion No corrosion shall be apparent on any of the specimens when viewed under five-power magnification. 6.5.5. Chemical Resistance The coating shall not blister, soften, disbond, develop holidays, nor exhibit any undercutting at the drilled holes. 6.5.6. Cathodic Disbonding No film failure shall take place during the first 1 hour of testing. Such film failure would be evidenced by the evolution of hydrogen gas at the cathode or appearance of corrosion products of steel at the anodes except that such hydrogen evolution or corrosion products at the intentionally cut 6.4-mm ( 1 / 4 -in.) 3 mm (0.12 in) holes will not be considered as basis for rejection. However, no undercutting shall be permitted during the remainder of the test period at the intentionally cut 6.4-mm ( 1 / 4 -in.) holes in either the anode or cathode. 6.5.7. Coating Hardness The hardness of the coating shall exceed the Knoop Hardness Number of 16. 6.5.8. Coating Impact Resistance No shattering or disbonding of the coating shall occur except at the impact area (area permanently deformed by the tup). 7. SAMPLING 7.1. A minimum of 24 14 dowel bars, of which up to six may be in a basket assembly, shall be furnished by the manufacturer for testing and verification of the materials and process. The specimens shall be made available to the testing laboratory 120 60 days prior to their first intended use. When fixed mechanical assembly is being used, a complete assembly with dowels shall be made available upon request by the purchasing agency. TS-4g M 254-3 AASHTO

8. DOCUMENTATION 8.1. Tests performed according to this specification shall be the responsibility of the manufacturers and/or coating applicator and may be performed at his laboratory or an independent laboratory approved by the purchasing agency. Upon completion of the tests, all tested specimens shall be properly labeled as to test procedure, and be made available upon request to the purchasing agency. 8.2. The laboratory facilities and procedure must be open to observation by the purchaser while tests are underway. The purchasing agency reserves the right to check any or all parts of the required tests in the agency laboratory or a laboratory of his choice. 8.3. The coated dowel manufacturer and/or coating applicator shall provide certified copies of test reports to the purchasing agency showing all test data. 8.4. For the purpose of identification, the manufacturer or applicator shall provide certification showing the generic type of coating material along with the type and percentages of pigments, diluents, fillers, flexibilizers, and other additives used. 8.5. The coated dowel manufacturer is defined as a company that produces a complete product consisting of dowel bar and coating. 8.6. The coating applicator is defined as a company that applies coatings to dowel bars. 8.7. Rechecks of the coated dowels may be made at the discretion of the purchasing agency. The purchasing agency may delete any of the above specified test procedures during rechecks of any previously approved product. 9. STORAGE 9.1 Epoxy coated dowels stored outdoors for more than 3 months shall be covered with opaque polyethylene sheeting or other suitable opaque protective material. 9.2 Dowels coated with Tectyl or similar material can remain uncovered for a period of one year without detriment to the epoxy coating. Tectyl coated dowels fabricated more than a year in advance of installation shall be stored inside or covered with opaque polyethylene sheeting or other suitable protective material. Formatted: Heading 1 Formatted: Indent: Left: 0", Hanging: 1" Formatted: Indent: Left: 0", Hanging: 1" TS-4g M 254-4 AASHTO