A novel solution for various monitoring applications at CERN

Similar documents
ATLAS NSW Alignment System. Study on Inductors

TWO TRANSPARENT OPTICAL SENSORS FOR THE POSITIONING OF DETECTORS USING A REFERENCE LASER BEAM

The Henryk Niewodniczański INSTITUTE OF NUCLEAR PHYSICS Polish Academy of Sciences ul. Radzikowskiego 152, Kraków, Poland.

The BCAM Camera. ATLAS Internal Note. Kevan S Hashemi 1, James R Bensinger. Brandeis University. 15 September Introduction

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Pixel CCD RASNIK. Kevan S Hashemi and James R Bensinger Brandeis University May 1997

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Layout and prototyping of the new ATLAS Inner Tracker for the High Luminosity LHC

BEAM HALO OBSERVATION BY CORONAGRAPH

ALIGNMENT METHODS APPLIED TO THE LEP MAGNET MEASUREMENTS. J. Billan, G. Brun, K. N. Henrichsen, P. Legrand, 0. Pagano, P. Rohmig and L. Walckiers.

RESULTS OF 3D PHOTOGRAMMETRY ON THE CMS BARREL YOKE

Optical Engineering 421/521 Sample Questions for Midterm 1

TEST AND CALIBRATION FACILITY FOR HLS AND WPS SENSORS

REAL TIME SURFACE DEFORMATIONS MONITORING DURING LASER PROCESSING

Performance of 8-stage Multianode Photomultipliers

Muon detection in security applications and monolithic active pixel sensors

plasmonic nanoblock pair

Supplementary Materials

Hartmann Sensor Manual

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

Totem Experiment Status Report

Development of a Displacement sensor for the CERN-LHC Superconducting cryo-dipoles

THE OPTICAL SYSTEMS OF LHCb RICHes: A STUDY ON THE MIRROR WALLS AND MIRROR SPECIFICATIONS

FRAUNHOFER AND FRESNEL DIFFRACTION IN ONE DIMENSION

Supplementary Figure 1

Single Photon Interference Katelynn Sharma and Garrett West University of Rochester, Institute of Optics, 275 Hutchison Rd. Rochester, NY 14627

Status of the Electron Beam Transverse Diagnostics with Optical Diffraction Radiation at FLASH

1 st IFAC Conference on Mechatronic Systems - Mechatronics 2000, September 18-20, 2000, Darmstadt, Germany

Wavelength Stabilization of HPDL Array Fast-Axis Collimation Optic with integrated VHG

DQW HOM Coupler for LHC

The HERA-B Ring Imaging Cerenkov ˇ Detector

Status of the LHCb Experiment

Difrotec Product & Services. Ultra high accuracy interferometry & custom optical solutions

ADVANCED OPTICS LAB -ECEN Basic Skills Lab

Laser Telemetric System (Metrology)

Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components

Precise hardening with high power diode lasers using beam shaping mirror optics

Metrology Studies and Baseplate-Pixel Sensor Gluing of the Pixel Strip Modules for the CMS II Phase Upgrade

Roman Pots. Marco Oriunno SLAC, PPA. M.Oriunno, SLAC

PoS(VERTEX2015)008. The LHCb VELO upgrade. Sophie Elizabeth Richards. University of Bristol

The LHCb Upgrade BEACH Simon Akar on behalf of the LHCb collaboration

RF System Models and Longitudinal Beam Dynamics

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Residual Resistivity Ratio (RRR) Measurements of LHC Superconducting NbTi Cable Strands

Proton Induced Thermal Stress Wave Measurements in. Solid Targets

Pixel hybrid photon detectors

PoS(EPS-HEP2017)476. The CMS Tracker upgrade for HL-LHC. Sudha Ahuja on behalf of the CMS Collaboration

The CMS Silicon Strip Tracker and its Electronic Readout

simulations, tests and production

ADVANCED OPTICS LAB -ECEN 5606

ATLAS ITk and new pixel sensors technologies

LHCb Preshower(PS) and Scintillating Pad Detector (SPD): commissioning, calibration, and monitoring

Laser Beam Analysis Using Image Processing

A Possible Design of Large Angle Beamstrahlung Detector for CESR

Digital Photographic Imaging Using MOEMS

INTERFEROMETER VI-direct

Assembly and Experimental Characterization of Fiber Collimators for Low Loss Coupling

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

PROCEEDINGS OF SPIE. Measurement of low-order aberrations with an autostigmatic microscope

User s Guide Modulator Alignment Procedure

Proposal of test setup

NanoSpective, Inc Progress Drive Suite 137 Orlando, Florida

Acceptance test for the linear motion actuator for the scanning slit of the HIE ISOLDE short diagnostic boxes

Sensor production readiness

Integrated CMOS sensor technologies for the CLIC tracker

Tutorial Zemax 9: Physical optical modelling I

Ultra-stable flashlamp-pumped laser *

ALMY Stability. Kevan S Hashemi and James R Bensinger Brandeis University January 1998

On-line spectrometer for FEL radiation at

Applying of refractive beam shapers of circular symmetry to generate non-circular shapes of homogenized laser beams

16. Sensors 217. eye hand control. br-er16-01e.cdr

The Commissioning of the ATLAS Pixel Detector

Week IV: FIRST EXPERIMENTS WITH THE ADVANCED OPTICS SET

Proposed Adaptive Optics system for Vainu Bappu Telescope

Figure 7 Dynamic range expansion of Shack- Hartmann sensor using a spatial-light modulator

LHC Experiments - Trigger, Data-taking and Computing

4DAD, a device to align angularly and laterally a high power laser using a conventional sighting telescope as metrology

Corundum C Axis Device for Sample Preparation Timothy Thomas, M.E., M.S.E.E. GIA Laboratory June 4, 2009

arxiv: v2 [physics.ins-det] 13 Oct 2015

CTPPS Detector Performance

Instructions for the Experiment

Laser Alignment System for LumiCal

A LATERAL SENSOR FOR THE ALIGNMENT OF TWO FORMATION-FLYING SATELLITES

8.882 LHC Physics. Detectors: Muons. [Lecture 11, March 11, 2009] Experimental Methods and Measurements

Measuring Procedure the Principle. The laser beam is scanned by means of a specialized measuring tip within a 3D measurement cylinder.

Opto Engineering S.r.l.

AIDA-2020 Advanced European Infrastructures for Detectors at Accelerators. Milestone Report

Calculation of Remanent Dose Rate Maps in the LHC Beam Dump Caverns

A 3D Profile Parallel Detecting System Based on Differential Confocal Microscopy. Y.H. Wang, X.F. Yu and Y.T. Fei

MEASUREMENT APPLICATION GUIDE OUTER/INNER

Installation of OpLevs in KAGRA - Manual -

A novel tunable diode laser using volume holographic gratings

Optical Correlator for Image Motion Compensation in the Focal Plane of a Satellite Camera

Polarization Experiments Using Jones Calculus

MACHINE TOOL ALIGNMENT TESTS

Understanding Optical Specifications

Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs

High Energy Digital Radiography & 3D-CT for Industrial Systems

Astigmatism Particle Tracking Velocimetry for Macroscopic Flows

Upgrade of the CMS Tracker for the High Luminosity LHC

Transcription:

A novel solution for various monitoring applications at CERN F. Lackner, P. H. Osanna 1, W. Riegler, H. Kopetz CERN, European Organisation for Nuclear Research, CH-1211 Geneva-23, Switzerland 1 Department of Interchangeable Manufacturing and Industrial Metrology, University of Technology, Karlsplatz 13/3113, A-1040 Vienna, Austria E-mail: Friedrich.Lackner@cern.ch Abstract. The construction of the LHC, world s largest particle accelerator, includes the highprecision positioning of large structures. To achieve the needed accuracy, the development and implementation of new monitoring methods is required. Keywords: BCAM monitoring system, Corner cube prism, 1. Introduction Situated on the outskirts of Geneva, CERN is the leading centre for particle physics in the world. The Large Hadron Collider (LHC) with its 27 km ring - shaped accelerator, which is currently under construction and will be operational in 2007, will begin a new era in high energy physics by revealing the basic constituents of the universe. The LHC is going to collide proton beams configured in bunches of 10 11 protons separated by 25 ns, giving a centre of mass energy of 14 TeV. It will collide ion - beams as well. The collisions will take place at four experimental sites on the accelerator ring. One of the experiments is ALICE, short for A Large Ion - Colliding - Experiment, a detector consisting of multiple layers of subdetectors around the collision point to detect different types and properties of particles created in the collisions. Those particles are identified via their energy, momentum, track and decay products, therefor it is important to align the various subdetectors very precisely to each other and monitor their position. The monitoring - systems have to function for a very long time under extreme conditions (e.g. high radiation) and must not absorb too many of the particles created in the collisions. In the following chapters a system developed for that purpose is presented with some of its applications at ALICE. CCD Device Socket (RJ-45) Lens Steel balls Laser diodes Mounting plate Figure 1: left: BCAM (91 x 55 x 30 mm); right: mounting principle 27

2. The BCAM-System The BCAM (Brandeis CCD Angel Monitor) (Figure 1) [1] is a simple optical device which has been developed by Brandeis University for one of the LHC experiments. It consists of an electronic camera and a pair of light sources, all integrated into a single enclosure kinematically mounted on three steel balls. The camera contains a CCD (Charge Coupled Device) image sensor and a lens with a focal length of 72 mm. Its field of view is 40 mrad horizontally and 30 mrad vertically to its mounting plane. The CCD provides an array of 344 by 244 pixels, serving as a two - dimensional coordinate system. A pixel measures 10 µm square. The light sources of the BCAM are red laser diodes, treated as being point - like. Each laser transmits at 650 nm in a rectangular cone that measures 75 mm by 25 mm on a screen at a distance of 100 mm from the BCAM. Lasers and CCDs can be controlled via an RJ - 45 socket. The centres of the steel balls on which the BCAM is mounted define a local BCAM - coordinate system. All relevant BCAM - parameters, like e.g. the centre of the lens or CCD rotation, can be related to this local coordinate system by a calibration procedure. Thus one only needs to know the position of the centres of the steel balls in a global coordinate - system to know position and orientation of the BCAM - coordinate system. The standard setup for a BCAM measurement contains two BCAMS, BCAM A looking at BCAM B. Flashing the light sources of BCAM A yields two light spots on the CCD of BCAM B. When A moves, the light spots on the CCD move as well. Knowing the spot movement on the CCD and the focal length of the BCAM, one can calculate the angular movement of A. If the distance between the light sources of A is known, the distance between the two BCAMs can be calculated as well. The BCAM is connected to a driver board with a TCP/IP interface that can be connected either directly to a PC or to the internet via a network plug. The BCAMs can be connected to the driver either directly or via a multiplexer that connects up to ten BCAMs. With the driver supplying all the connected devices with power, the BCAM system is a stand alone data acquisition system connected to the rest of the world through the driver s Ethernet socket [2]. The angular resolution of a BCAM is 5 µrad. The resolution when measuring a small angular separation, this including two consecutive angle - measurements, is therefor 7 µrad. This limit is given by the errors of the calibration. In addition to the measurement of the relative angle of two BCAMs, the relative distance of two cameras is given by the separation of the light spots on the CCD. The accuracy of this measurement depends on the distance D between the light spots and the camera according to dx. 6 2 5 10 D dx = 16 As an example, at a distance of 1 m the accuracy is 0.3125 mm. 3. Applications ALICE - Spaceframe. The subdetectors of the ALICE - Detector are held in place by a structure called Spaceframe (Figure 2). It has a cylindrical 18 - sided geometry with a length and diameter of 8 m. The weight of all the subdetectors, about 80 tons on the whole, will deform the Spaceframe. For obvious reasons these deformations have to be monitored. 28

Simulations have shown that deformations will only happen in a plane perpendicular to the axis of the Spaceframe. The 18 corners of the Spaceframe will show up to 5 mm relative movements according to the simulations. The Spaceframe Monitoring System has to determine all the positions of the corners to an accuracy of better than 500 µm. The BCAM system is implemented by fixing a mounting plate with two BCAMs on each corner. By measuring the relative angles of all BCAMs the 18 internal angles of the Spaceframe are monitored. Figure 2: ALICE - Spaceframe Detector - Monitoring. In particle physics experiments it is necessary to monitor the position of all subdetectors [5] with high accuracy. One way of realising this task is to put one BCAM on the subdetector and one BCAM on an external reference point. Since some detectors are to fragile to carry a BCAM and since space is usually limited, a novel solution is required. The idea is to mount a BCAM on the external reference point and a reflecting mirror on the subdetector. Using a corner cube prism instead of a plane mirror eliminates the sensitivity to rotations of the mirror. Tests results for this application are presented in the next section. 4. Test results for mirror application The tests were done in a cleanroom with a standard BCAM (one CCD) and one corner cube prism made of BK7. BCAM - Corner cube test alignment. Initial distance corner cube - BCAM: 820 mm Adjusting plate movement precision: 1 µm Measured distance: 20 mm 10 measurements for each 0.5 mm = 410 values/test Corner cube diameter: 15 mm The following diagrams present two of several results about the correlation between corner cube prism movements with respect to the BCAM. Figure 3 shows the averaged distance between the two spots on the CCD during a longitudinal corner cube prism movement with 29

respect to the BCAM. This function shows linar behavior. The residuals of the linear fit have a standard deviation of σ = 0.204389 µm resulting in a measurement accuracy dx = 250 µm. The LWDAQ software settings [1] for this test were the same as for the standard two BCAM alignment. 725 Longitudinal movement 720 Spot movement (µm) 715 710 705 700 y = 0.8382x + 705.18 average linear movement longitudinal Linear fit 695 0 5 10 15 20 Corner cube prism movement (mm) Figure 3: Longitudinal corner cube prism movement Figure 3 shows the averaged x and y spot positions on the CCD after a transverse corner cube prism movement with respect to the BCAM. The spot properties are almost constant and the output function represents a linear correlation. For the measured distance the spot intensity is satisfactory. The residuals of the left spot have a standard deviation of σ 1 = 0.318111 µm giving an accuracy of dx 1 = 4.379548 µm. The residuals of the right spot have a standard deviation of σ 2 = 0.28528 µm giving an accuracy of dx 2 = 3.9218 µm. 3500 3000 Horizontal movement 2500 y = 45.695x + 1011.7 Spot movement (µm) 2000 1500 1000 averaged horizontal movements Spot1 averaged horizontal movements Spot2 Linear fit spot1 500 y = 45.745x + 301.7 Linear fit spot2 0 0 5 10 15 20 Corner cube prism movement (mm) Figure 4: horizontal corner cube prism movement 30

We conclude that a corner cube prism at a distance of 810 mm from the BCAM can be tracked with an accuracy of around 5 µm transverse to the BCAM axes and 250 µm in the longitudinal direction. For larger distances we expect a linear decrease of the accuracy for the transverse direction and a quadratic decrease for the longitudinal direction. Minimizing the material absorbtion by using coated mirrors is not necessary for distances up to 10 m. For distances greater than 10 m the intensity can be optimized by using coated corner cube prisms. It has to be mentioned, that the corner cubes physical basic principle is the rationale of a mirror. 5. Summary The BCAM offers a very simple solution for position monitoring of large structures. A BCAM follows the movement of light sources with 5 µrad or better accuracy all across its field of view. A BCAM at a distance of 20 m can be tracked with accuracy better than 100 µm. A further development consists of a BCAM together with a corner cube prism. Tests with a prism in a distance of 800 mm from a BCAM show a measurement accuracy of 5 µm in the transverse direction and 250 µm in the longitudinal direction. As the accuracy and the spot properties are the same as with two BCAMS, the system can also be used where there is not enough space for a two BCAM solution. References: [1] K. Hashemi, BCAM User Manual (Version 11), Brandeis University, Boston (October 2004), Open Source Instruments, www.opensourceinstruments.com. BCAM drawings, reports, circuit diagrams and manuals are distributed for free under the GNU Public License, copyright Kevan Hashemi. [2] K. Hashemi, LWDAQ User Manual (Version 3.2.2), Brandeis University, Boston (December 2004) [3] ALICE Collaboration, ITS, Technical Design Report, CERN/LHCC 1999 ALICE TDR 4, 18 June 1999 [4] The Large Hadron Collider Project General Information. http://lhc.web.cern.ch/lhc/general/gen_info.htm [5] ALICE Collaboration, Physics Performance Report, Volume I, 19 October 2004 31