save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

Similar documents
DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Prolific Systems & Technologies Pvt. Ltd. CORE DETAILS. CENTRE Figure - II L-2 X Y Wt-2

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

Basic Principles and Operation of Transformer

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

Introduction. Centrado leading-edge transformer. Introduction

Liquid-Filled Transformers

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

OIL-IMMERSED ARC-SUPPRESSION COILS

ELETTROMECCANICA. Since english OIL IMMERSED DISTRIBUTION TRANSFORMERS

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

SOUTHERN ELECTRICITY SUPPLY COMPANY OF ODISHA LIMITED (SOUTHCO UTILITY)

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

Power Transformers Basics

Industrial Applications

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

K Factor Power Transformers

Tougher than any challenge. Transformers for highcurrent. industrial applications. siemens.com/transformers

Transformer Protection

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

TRANSFORMER OPERATIONAL. Principles, Selection & Troubleshooting

EE059: Transformer Operation, Maintenance, Diagnosis & Testing

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

Pomona, CA May 24 & 25, LTC Applications - Location, Series & Preventative Auto Transformers

Substation Preventive Maintenance

SPECIFICATION FOR 11 KV CLASS, 24/15.7, 30/19.7 & 45/29.5 AMPS SPECIAL DESIGN TRANSFORMERS.

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

CAST RESIN DRY TRANSFORMER

Cast resin transformers HARMONY TM

TRANSFORMER TECHNOLOGY GPT

Distribution and Power Transformers

Electrical Design Process

PUBLIC POWER CORPORATION ENGINEERING & CONSTRUCTION OF TRANSMISSION PROJECTS DEPARTMENT

On-Load Tap Changer Type M

TMC Transformers TMC

Basic principles and operation of a transformer

Problems connected with Commissioning of Power Transformers

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

Power transformers for Network, Rectifiers, Furnace

DISTRIBUTION TRANSFORMERS

MODERN POWER TRANSFORMER PRACTICE BIBLIOGRAPHY

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

HOW TO SAFE GUARD THE TRANSFORMER..???

SHARDA Make Harmonics Filter

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

Distribution Equipments - Technology and Applications. Training Module for DISTRIBUTION TRANSFORMER

nical catalogue Tech

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

APDRP SCHEME, WESCO. Technical Specification for Distribution Transformers ( 11/0.4KV ) PART 1: GENERAL

Particulate Control O&M Training. APC/PCUG Conference July 12-16, 2009 The Woodlands, TX

Hands-On Transformer Testing and Maintenance

Transformer Factory Testing

Regional Technical Seminar SHORT CIRCUIT FORCES

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

Mechanical Design. Brian Brinson Mechanical Design Manager.

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

DISTRIBUTION TRANSFORMERS

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

PES & IAS NY Chapter And NY LMAG June 23 rd, 2015

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

ISSN: [IDSTM-18] Impact Factor: 5.164

LIQUID IMMERSED INDUSTRIAL TRANSFORMERS. For metallurgical, steel, chemical, glass plants and VSD TRANSFORMING THE FUTURE. seatrasformatori.

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

1 SCOPE & INTENT OF SPECIFICATION

Powering Your Business

SECTION TRANSFORMERS

ABB Power Products Service

VIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs

TRANSFORMERS PART A. 2. What is the turns ratio and transformer ratio of transformer? Turns ratio = N2/ N1 Transformer = E2/E1 = I1/ I2 =K

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

High Voltage Generation

EARTHING TRANSFORMER

Distribution Transformers. The most comprehensive range of solutions for distribution transformer applications

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

TECHNICAL DESCRIPTION ND-387. THREE-PHASE TRANSFORMERS, 150 / 21kV, 40/50MVA AND 20/25 MVA, Dyn1

~=E.i!=h. Pre-certification Transformers

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

TATUNG POWER TRANSFORMERS

TECHNICAL DATA TYPE CMD OIL-IMMERSED ON-LOAD TAP CHANGER

PS REV NO: 01 PAGE : 2 OF 22

SPECIFICATION No SS-88/5 630 kva, 30 / 0.4 kv THREE-PHASE TRANSFORMERS WITH ON-LOAD TAP CHANGER

DESIGNED MANUFACTURED TESTED

General Electricity Company of Libya

Technical Questionnaire 9.101/6 Transformer Test System. Personal Data. Application. Test of. Delivery scope

Transcription:

save energy, it is precious Mfg. of all types of Distribution / Power & Furnace Transformers SYNERGY transformers

SAFETY AND EFFICIENCY, COMBINED WITH LONG-TERM RELIABILITY, ARE THE HALLMARKS OF WORLD-RENOWNED PRODUCT PERFORMANCE.

INNOVATING, INVESTING, DELIVERING & ENERGIZING For, Synergy Transformers to succeed, energy has to be everywhere. In our ideas, our goals, and our day-to-day work. Energy is inspiring. Energy makes the world go round.

ABOUT We at Synergy Transfomers are a team of engineers with expertise in electrical field. We are engaged in the manufacturing of distribution transformers and special purpose transformers under the brand name synergy. We firmly believe in quality and that too backed up by after sales services to their installations throughout INDIA. Synergy Transfomers was established in the year 2004. The company is based at Agatrai 130 kms. North of Rajkot, one of the fastest growing industrial zone of the country. The city is well connected by air, rail and road. We are manufacturing oil filled distribution transformers 100 KVA to 5 MVA and furnace and power transformers upto 15 MVA 66 KV class. We design and manufacture a complete rang of transformers in our class. We at synergy transfomers see that our customers get the best of the products and an excellent after sales service support.

INDEX 01 DISTRIBUTION TRANSFORMERS PAGE 05 02 FURNACE TRANSFORMERS PAGE 07 03 POWER TRANSFORMERS PAGE 09

1. OIL IMMERSED DISTRIBUTION TRANSFORMER We manufacture wide range of Oil Cooled Distribution Transformers. The standard range is 50 KVA to 3750 KVA. OFF LOAD DISTRIBUTION TRANSFORMER MAIN FEATURES (1) Designed for 25 years of trouble-free performance (2) Magnetic circuit - Step-lap designed for lower losses and excitation current cold-rolled silicon-steel plate M3 to M5, MOH and ZDKH type (3) Electric circuit - Electrolytic grade 99.99% high-quality oxygen-free copper lines with transposition in L.V. coil for current sharing in parallel conductors or copper foil. (4) Dielectric circuits - High Dielectric Insulation Property to withstand lightening impulse. (5) Thermal circuit - ONAN through natural convection for effective cooling through axial and radial ducts. Modern manufacturing techniques ensure cost effectiveness, reliability and a long trouble-free performance TECHNICAL SPECIFICATIONS Duty, Type Outdoor / Indoor, Pole or Ground Mounted Voltage Class 3.3, 6.6, 11, 22,33 Kv or any Specific No of phases 1 or 3 phase Frequency 50/60 Hz Vector Group Dyn 1 or Dyn 5 or Dyn 11 or any specific Insulating Fluid PCB Free Mineral Oil, both inhibited & uninhibited, as per IS/IEC and customer requriement Class of Insulation Class A Tap Changer Off Circuit or On Load Tapping Range ±7.5% in 7 Step or ±5% in 5 Step with 2.5% Step Volts. Winding Material Aluminium or Copper with multi paper covering Applicable Standards IS 2026, IEC 76, ANSI, IEEE Painting Epoxy, Polyurethane or customer specific STANDARD FITTINGS (01) Rating & Diagram Plate (02) Earthing Terminals (03) Lifting Lugs (04) Thermometer Pocket (05) Air Release Hole with Plug (06) Oil Conservator with Drain Plug (07) Explosion Vent with Diaphragm (08) Oil Level Indicator (09) Drain-cum-Bottom-Filter Valve (10) Top Filter Valve with Plug (11) Bi-directional Rollers (12) Silica Gel Breather (13) Cooling Radiators (14) LV Side Cable Box & Copper Bus Bar Suitable for Cable PROTECTIVE DEVICES (01) Buchholz Relay with Alarm and Trip Contact upto 500 KVA (02) Oil Temperature Indicator with Alarm an Trip Contact (03) Winding Temperature Indicator with Alarm and Trip Contact (04) Magnetic Oil level gauge with Alarm Contact (05) Marshalling Box to House O.T.I. and W.T.C. OPTIONAL ACCESSORIES ON REQUEST (01) Neutral C.T. (02) Shut - off Valves (03) Annunciation Window (04) Jacking Pads (05) Pressure Release Valve On Load switch with 9, 13, 17 Position in 1 Step Voltage Ratio 1.2% to 2.5% Increase or Decrease. ON LOAD DISTRIBUTION TRANSFORMER (with AVR)

APPLICATIONS A Distribution Transformer is a transformer that provides the final voltage transformation in the electric power distribution system, stepping down the voltage used in the distribution lines to the level used by the customer. Engineering Industries Domestic / Commericial Auto Industries Forging Industries Ceramic Industries Plastic Industries Hospitals

2. OIL IMMERSED FURNACE TRANSFORMER (Rectifier Duty Transformer) Furnace Transformers are designed for induction melting and inducting heating for ferrous and non-ferrous metal. Induction Furnace has coil constructed from heavy copper tubing. It is designed and tuned to the inverter circuit which applies a medium frequency (generally 500 Hz or 1000 Hz) voltage to the induction coil. The magnetic field produced by the induction coil induces eddy currents in the charge and heats it. Medium frequency is necessary to enhance the rate of heat generation. The inverter circuit requires for its operation a D.C. voltage which is obtained by converting available three phase A.C. voltage. Transformers which are used for transforming available three phase A.C. voltage to required voltage for converter circuit of the induction furnace are referred to as induction furnace transformers. Thus they are essentially Rectifier / Converter Duty transformers. FURNACE TRANSFORMER (6 PULSE) SPECIAL FEATURES (1) Electrostatic Earth Shield provided between Primary and Secondary side windings for protection of rectifier elements against voltage surges in Primary side windings. [Ref. D-3] (2) Use reduced current densities to limit losses due to harmonic currents. (3) Use reduced flux density to limit core losses due to harmonic flux. (4) Designed to suit 6 Pulse / 12 Pulse or other rectifier circuits as required by Furnace Manufacturer. Two active parts in one tank can also be provided. (5) Conforming to I.S. 2026 and I.S. 4540 - Specifications for Power Transformers and Specification for Rectifiers. Input voltage is derived from the rating of the rectifier transformers from standard three phase AC distribution voltage like 433 V, 3.3 kv, 6.6 kv, 11 kv, 33 kv, etc. These become the primary voltage of the transformer. Secondary voltage can be between 400 to 1000 V decided by the required D.C. output Voltage. Sr. Primary Secondary Remarks No. (1) Secondary winding. 1 (2) 2 way, using Bridge circuit. (3) 6 Pulse 2 (1) One delta and one star cell side windings (2) 2 way using Bridge circuit. (3) 12 Pulse D-1 Typical Rectifier Transformer Winding Connections in common use Shield Primary Side Windings Secondary Side Windings A Voltage Wave Form of 6 Pulse Circuit D-2 Output Voltage Wave forms in 6 / 12 Pulse Circuit B Voltage Wave Form of 12 Pulse Circuit D-3 Earthed Shield Provided Between Primary & Secondary Side Windings FURNACE TRANSFORMER (12 PULSE) Why weights and dimensions of Induction Furnace Transformers are higher than Conventional Transformers? (01) To achieve reduced current densities, more conductor cross section areas are required. Hence core weight increases. (02) To achieve reduced flux density, more core cross section area is required, hence core weight increases. (03) In a transformer, core weight and copper weight are inter dependent. Increase in conductor cross section requires that core window area be bigger resulting in increase of core weight also. Similarly increase in core cross section is achieved by increasing core dia. which increases mean dias of winding and the lengths of their mean turn. This increases copper weight also. Increase in core and copper weights increase the overall dimensions, increasing oil quantity, structural steel etc. (04) When an electrostatic shield is provided between the windings, more radial gap is required between the windings. This further increases core weight, copper weight, oil quantity and structural steel.

APPLICATIONS Furnace Transformers are used in steel plants, casting & forging industries where melting of metals is the primary business. Induction Heating Induction Melting

POWER 3. TRANSFORMER SPECIFICATIONS (01) 3 phase, 50 Hz in voltages of 11kV, 22kV, 33kV, 66 kv & 110 kv (02) Off-circuit tap changer to provide ± 5 %,± 7.5% & +5% to -10% taps in steps of 2.5% (03) On load tap changer to provide +5% to -15% taps in steps of 1.25% as standard range & also custom built for any other ranges. OLTC will be internally/externally mounted as per the requirement (04) Class A, uniform/non-uniform insulated (05) Vector group Dyn 11, YNd 11, YNyn 0 (06) Continuous duty, double copper wound (07) Painting as per IS/IEC standards (08) Both HV & LV side outdoor bushings or cable boxes (09) Cooling radiators/fans. (10) Standard fittings as per IS/IEC standards (11) Buchholz relay with alarm and trip contact with shut off valves (12) Oil temperature indicator with alarm and trip contact (13) Winding temperature indicator with alarm and trip contact (14) Magnetic oil level gauge with alarm contact (15) Marshaling box to house oil temperature indicator and winding temperature indicator (16) Cooler control unit (17) Neutral current transformer FEATURES (01) Designed for 25 years of trouble-free performance (02) Design conforms to IS 2026, IEC 60076, ANSI and other relevant standards (03) Low power loss and low noise (04) Designed to withstand electrical impulses and thermal and dynamic stresses (05) Optimum utilization of active materials for compactness (06) Modern manufacturing techniques ensure cost effectiveness and reliability OPTIONAL ACCESSORIES (01) Winding temperature indicator and oil temperature indicator with remote indication (02) RTDs for winding temperature measurement (03) Oil preservation system through air cell/thermosphyon filter (04) Neutral earthing bar with epoxy supports

APPLICATIONS Synergy manufactures power transformers from 3.0 MVA 33/11 kv upto 15 MVA, 66 kv voltage class. All transformers can be supplied with the desired tappings for positive/negative voltage variation either with OFF circuit or ON load tap changers. We can also manufacture intermediate sizes with non standard voltage ranges as per customer requirements. Synergy power transformers are currently in operation in several power utilities playing an important role in efficient transmission and distribution of electricity. Hydro Power Plant Coal Power Plant Solar Power Plant

Reproduction in whole or in part without permission is prohibited. Synergy Transformers. All Rights Reserved. SYNERGY transformers Works: National Highway 8-D, Nr. Trishul Motors Agatrai, Ta.: Keshod, Dist : Junagadh. (Gujarat) +91 2871 299555 synergytransformers@yahoo.com sales@synergytransformers.com www.synergytransformers.com Regd. Office: "Diksha Parva" Maheshwar Madhi Main Road, Pipaliya Nagar, Mangrol Road, Keshod-362220, Dist: Junagadh. (Gujarat) +91 2871 253077 95861 77766 95862 77766 95463 77766 95864 77766 www.vrvenus.com +91 78787 54321