Falcon F35 & F45 Digital Panel Meters

Similar documents
Hawk 3 Digital Panel Meter / Controller

DC Voltage Hawk II H235 Series Advanced Digital Panel Meter

S662 Preset Batch/Dual Counter

S663 Preset Rate/Totalizer Counter

DIN SERIES DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

S660 Preset Totalizer Counter

Economical Digital Indicators For Process and Electrical Measurement

DP2000 ORDERING GUIDE To Order MODEL NO.

USB-2404-UI Specifications

Process displays For standard signals, temperature, resistance measurement

PANEL MOUNT PROCESS METER IDP

Model 580 Digital Process Indicators Series

DRG-SC Series Signal Conditioners

SDM3045X Digital Multimeter. DataSheet

Digital Panel Meters DC/AC Current and Voltage Indicator/Controller Type LDM40

INPUT RESISTANCE OR CLAMP VOLTAGE. 2 Years 23 C ±5 Voltage mv 3 10 nv > 10 G

UL CONDITIONS OF ACCEPTABILITY

Chapter 6 Specifications

RS Pro DIGITAL MULTI-METER SDM3055 SERIES

EN SERIES NEMA CASED DIGITAL PANEL METERS ELECTRO- NUMERICS, INC.

Advanced Ladder Logic Full IEC Languages 25A for <1 24 VDC DC Switched

HP 34401A Specifications 8

Model 6517B Electrometer / High Resistance Meter Specifications

4-20mA, 0-10V and general process measuring bargraph displays

SDM3045X Digital Multimeter. DataSheet

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Isolated DIN Rail Mount Loop-Powered 2-Wire Signal Conditioners. DRLP Series

SHIMADEN DIGITAL INDICATORS

RIGOL Data Sheet DM3058/DM3058E Digital Multimeter Product Overview Applications Easy to Use Design Main Features owerful Measurement Functions

DIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.

Digital Multimeter Series

SHIMADEN DIGITAL INDICATOR

USB-TEMP and TC Series USB-Based Temperature Measurement Devices

RD700 RD701 DIGITAL MULTIMETER INSTRUCTION MANUAL

ENGLISH. General features 2. Technical features 3. Installation 10. Preliminary operations 12. Front panel description 13.

SHIMADEN DIGITAL INDICATORS

MINI 048 / JUN 2003 PAGE 1. Temperature I/O Module HE500OCS048 / HE500OCS078 HE500RCS078

MODEL: M2XU MODEL: M2XU [1][2] [3][4]

Each click of a dial opens a doorway to precision. 2553A. Precision DC Calibrator. Bulletin 2553A-01EN

Process Calibrator. TechChek 820

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

PID CONTROLLERS LT SERIES

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

High Performance Process & Temperature Controllers

APPA 300 Series. The Most User-Friendly High Performance Multimeter

8588A Reference Multimeter

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

SDM3055 Digital Multimeter. DataSheet

R24 DISPLAY MODULE WITH ACTIVE OUTPUT AND RELAY

Fuzzy Temperature Controllers E5AF

Model Multimeter Specifications ABSOLUTE ACCURACY TYPICAL ACCURACIES 2002 SPECIFIED CALIBRATION INTERVALS

MODEL: M6SXU MODEL: M6SXU [1][2] [3][4]

ISOLATED 4-20 ma TRANSMITTERS

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

Multifunction Intelligent 4-wire Isolated Signal Conditioner

Specifications. 744 Users Manual

Miniature Low-Cost Temperature Transmitters MTX

ATK Clamp Meter

Pen Multimeter. Model

Practical Instrument Electronics PIECAL 820

8558A 8 1/2 Digit Multimeter

PC500 PC510 DIGITAL MULTIMETER INSTRUCTION MANUAL

Keysight 34401A Multimeter

INSTRUCTION MANUAL DIGITAL MULTIMETER

DIGITAL MULTIMETER INSTRUCTION MANUAL

- SMART TUNE- PID CONTROL - UNIVERSAL, 3 WIRE- TC, RTD AND LINEAR INPUT - AUX- REMOTE SET POINT/ TRIM INPUT - 2x ISOLATED CONTROL AND RETRANSMISSION

7SD/7SH/7SM Temperature Controllers

OPERATOR S INSTRUCTION MANUAL

SDM3055 Digital Multimeter. DataSheet

1.General instructions Specifications Description...7

Light-strip indicator

ORDERING INFORMATION T79D

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

Datasheet. SDM3065X Digital Multimeter. Product Overview. Main Feature. Application fields. Main Function

MODEL: W2TS. Mini-MW Series

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Digital MultiMeter - Make your job efficiency User Instruction Manual

Excellent low-cost Process & Temperature Controllers

General Specifications

GAMMA 10 DIGITAL MULTIMETER

DATA SHEET A Multimeter 5.5 Digit Dual Display, Benchtop DMM

Pen Multimeter. Model

EX1000 Series EX1000A EX1000A-TC EX1016A EX1032A EX1048A EX10SC EX1000A-TCDC RELIABLE DATA FIRST TIME EVERY TIME.

FC-33, DC SELECTABLE SIGNAL CONDITIONER

Digital Multimeter with Backlight

PRODIS. PD-INC Digital Process Meter for sensors with incremental output. Digital Process Meters. Datasheet

SC200 Series. Signal Conditioner MNX10020, REV H 10/17/ Connection Technology Center, Inc Rae Boulevard Victor, NY (585)

Analog Digital Multimeter with Insulation Resistance Measurement

Temperature Transmitters - Head Mounted

DIN Thermocouple Conditioner MODEL 5M14(V)

Keysight Technologies U1210 Series Handheld Clamp Meters

APPENDIX APPENDIX A 1

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Temperature Controls

GAMMA 12 DIGITAL MULTIMETER

M4Y/M4W/M5W/M4M Series

SEM1600T RTD/TC/SLIDE WIRE SIGNAL CONDITIONER

DC1010/DC1020/DC1030/DC1040

MODEL PAX 1/8 DIN ANALOG INPUT PANEL METERS

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

Transcription:

1/8 DIN Indicator 3-1/2 or 4-1/2 digit bright red LED display Front panel pops off for easy decimal point setting and display scaling Only 3.12 (79mm) required behind panel Optional excitation output NEMA 4X removable cover, using part # 45003 1 Rev. 11-21-16

Ordering Information - F or C I I I I I Basic Unit Power Supply Function/ Excitation Output Display Option (temp. units only) Select From Each One Below Basic Unit Function/ F35 3-1/2 digit LED 61 200 ACμA TRMS * F45 4-1/2 digit LED 62 2 ACmA TRMS * 63 20 ACmA TRMS * Power Supply 64 200 ACmA TRMS * 1 120 ACV 65 2 ACA TRMS * 2 220 ACV 66 5 ACA TRMS * 3 9-32 DCV 71 4-20 DCmA Process Function/ 72 1-5 DCV Process 11 200 DCmv 73 0-10 DCV Process 12 2 DCV 13 20 DCV 80 J T/C ** 14 200 DCV 81 K T/C ** 82 S T/C ** 21 200 DCμA 83 T T/C ** 22 2 DCmA 84 E T/C ** 23 20 DCmA 85 R T/C ** 24 200 DCmA 86 DCmV ** 25 2 DCA 90 RTD Pt100 Ohm ** 26 5 DCA 91 20-199.9 Hz RMS * 31 200 ACmV 92 20-1999 Hz RMS * 32 2 ACV 93 20-199.9 Hz Sq. Wave * 33 20 ACV 94 20-1999 Hz Sq. Wave * 34 200 ACV Excitation Output 41 200 ACμA (not available with AC, temperature, or frequency inputs) 42 2 ACmA 0 None 43 20 ACmA 1 12 DCV @ 25mA max. current 44 200 ACmA 2 24 DCV @ 25mA max. current 45 2 ACA 46 5 ACA Display Option Temperature Meter C C 51 200 ACmV TRMS * F F 52 2 ACV TRMS * 53 20 ACV TRMS * 54 200 ACV TRMS * Not available for use with frequency meters * Only available with F35 ** Only available with F45 2 Rev. 11-21-16

DISPLAY Type Height Decimal Point Overrange Indication Polarity 7- segment, red LED 0.56 (14.2mm) User-programmable, internally or on the terminal block Automatic, with - indication, + indication implied POWER REQUIREMENTS AC Voltages 120 or 220VAC, ±10% 50/60Hz DC Voltages 9-32DCV, ±1% Power Consumption F35: 3VA, F45: 2VA ISOLATION 250V RMS MAX ACCURACY @25 C F45 DC Process/Voltage ±0.02% of reading ± 1 count F35 DC Process/Voltage ±0.1% of reading ± 1 count F45 DC Current ±0.05% of reading ±1 count 2A ± 5 counts, 5A ± 5 counts F35 DC Current ±0.1% of reading ± 1 count 2A ± 5 counts, 5A ± 5 counts F45 AC Voltage/Current ±0.5% of reading ± 35 counts F35 AC Voltage/Current * ±1% of reading ± 5 counts (50Hz-100Hz) * For TRMS (45 Hz to 1KHz) ENVIRONMENTAL Operating Temperature 0 to 55 C Storage Temperature -10 to 60 C Relative Humidity 0 to 85% non-condensing Warm-up Time Less than 15 minutes NOISE REJECTION NMRR CMRR A TO D CONVERSION Technique Rate F35=50dB, 50/60Hz; F45=60dB, 50/60Hz Dual slope integration F35=3 samples per second, nominal; F45=2.5 samples per second, nominal MECHANICAL Bezel 3.78 x 1.89 x.51 Depth 2.94 Panel Cutout 3.62 X 1.77 Case Material 94V-1, UL rated Noryl Weight 9.0oz (255.1g) F35 AC/TRMS (Voltage/Current) F35 DC (Voltage/Current/Process) F45 AC (Voltage/Current) F45 DC Current F45 DC (Voltage/Process) (±0.1% of input ± 0.5 count)/ C (±0.01% of input ± 0.05 count)/ C (±0.05% of input ± 0.5 count)/ C (±0.01% of input ± 0.1 count)/ C (±0.05% of input ± 0.1 count)/ C 3 Rev. 11-21-16

DISPLAY Type Height 7- segment, red LED 0.56 (14.2mm) Overrange Indication POWER REQUIREMENTS AC Voltages 120 or 220VAC, ±10% 50/60Hz Power Consumption 2.5VA min./4va max. ACCURACY @25 C 200 Hz ±0.2% of input ±0.2 Hz 2 KHz ±0.2% of input ± 2Hz INPUT LEVEL 500mV to 250V RMS at 1.0MΩ impedance OR 5V to 24V Square Wave (DCoffset 2V maximum) 200Hz = 0.1Hz 2kHz =1Hz ENVIRONMENTAL Operating Temperature 0 to 55 C Storage Temperature -10 to 60 C Relative Humidity 0 to 85% non-condensing @ 40 C (±0.05% of input ± 0.5 count)/ C Warm-up Time Less than 15 minutes CONVERSION Technique Rate Frequency-to-voltage 3 samples per second, nominal 4 Rev. 11-21-16

DISPLAY Type Height Decimal Point 7- segment, red LED 0.56 (14.2mm) Jumper-selectable 2-position (corresponding to resolution desired) Overrange Indication Polarity Automatic, with - indication, + indication implied POWER REQUIREMENTS AC Voltages 120 or 220VAC, ±10% 50/60Hz DC Voltages 9-32 DCV, ±1% Power Consumption 3VA ENVIRONMENTAL Operating Temperature 0 to 55 C Storage Temperature -10 to 60 C Relative Humidity 0 to 85% non-condensing Warm-up Time Less than 20 minutes INPUTS Thermocouple RTD Millivolt Conversion Rate Open Thermocouple Detection J, K, E, T, R, and S Platinum 100 (.00385 alpha), 2, 3 or 4 wire ±84mV reading of uncompensated mv 2-1/2 times per second -1 on displa, -40nA bias on thermocouple Temperature Sensor Type Temperature Accuracy E J K T RTD Pt 100 R,S -200 to 1000 C -328 to 1832 F -200 to 1200 C -328 to 2192 F -200 to 1372 C -328 to 2501 F -200 to 400 C -328 to 752 F -200 to 850 C -328 to 1562 F ±0.1% of rdg ± 1 C ±0.1% of rdg ± 1.8 F 0.1 or 1 Degree User Selectable -50 to 1768 C 1 Degree -58 to 3214 F Automatic Voltage ±84.00mV Voltage ±.02% of rdg ± 1 count 0.01 mv -19.999mV to +84.000mV ±.02% of rdg ± 1 count 0.001mV 5 Rev. 11-21-16

s DC Voltage F35 F45 Max (Unfused) 200mV >100MEG >100MEG 100V 2V 1mV >10MEG >10MEG 250V 20V 10mV >10MEG 1mV >9.9MEG 250V 200V 100mV >9.9MEG 10mV >9.8MEG 250V AC TRMS Voltage F35 F45 Max (Unfused) 200mV >100MEG >100MEG 100V 2V 1mV >1MEG >1MEG 250V 20V 10mV >10MEG 1mV >1MEG 250V 200V 100mV >9.9MEG 10mV >1MEG 250V DC / AC TRMS Current Voltage Max F35 F45 Drop (Unfused) 200mV DC Process F35 F45 Max (Unfused) 0.1 % 10 Ohms.01 % 10 Ohms 500mV 1 to 5Vdc 0.1 % >10MEG.01 % >9.9MEG 10V 0 to 10Vdc 0.1 % >10MEG.01 % >9.9MEG 10V 6 Rev. 11-21-16

Installation and Panel Cutout Engineering Label Mounting Requirements high by 3.62 (91.9mm) wide. To install the Falcon into a panel cutout, remove the clips from the side of the meter. Slide the meter through your panel cutout, then slide the mounting clips back on the meter. Press evenly to Engineering Label Placement If replacement of the engineering unit label is required, place the tip of a ballpoint pen into the small hole at the base of the engineering label in the bezel. Slide the label up until it pops out. Grasp and remove. Slide the new label half the distance in, then use the ball-point pen to slide it down into place. 7 Rev. 11-21-16