Led Spot MR16 10W Cold White by CDE Technology BV

Similar documents
Led Spot MR16 10W Neutral White with 700 ma constant current driver by CDE Technology BV

Led 12V 3W Spot Light GU5.3 by Tuono Lighting

20W TL 324 smd LED Warm White by Simplify-It

LED T5 30cm Warm White by BS Ledlight

High Bay Led Lamp by Glo

Line Lite International BV 7W Dimmable Downlight Sharp

Line Lite International BV 150 watt Cree PowerLED Streetlight 50 x 3 watt IP65 60 degr

Led Tube Light KLV-T8-121-WA by KLV Ledverlichting

Flood Light LVS-70 Warm White by Ledverlichting Soest

Lamp measurement report 1 Feb 09 for Line Lite International BV Line Lite International BV Sharp 4W GU10 WW

Line Lite International BV Petrol Gas Station Light 50 watt IP65

Lamp measurement report 25 March 09 for LedNed LedNed spotlight MR16GU5.3 WW

LVS C42 GU10 4W WW by Ledverlichting Soest

LVS D01 GU10 3W WW dim by Ledverlichting Soest

LVS C76 GU10 9W Nichia by Ledverlichting Soest

1200 x 300 mm led panel by ElektoLED

LVS A16 MR16 3x3W Cree by Ledverlichting Soest

Negative ion Lamp GTFL-13 by GreenTubes

Pharox MR16 by Lemnis

Lamp measurement report - 13 Nov 2012 LED light bulb E14 dimmable by Oxxy Light

Lamp measurement report - 13 May 2012 Led TL 120 cm 18W 6500K by Prolumia

Lamp measurement report - 11 Feb 2013 E27 led light bulb XP-e Cree 8x1W by TOP.LED.SHOP

Lamp measurement report - 13 April 2016 ONT x18 by Triolight B.V.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L540-C27-B25 tel: fax: lm x 0.

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P30LN-L600-C30-B25 tel: fax: lm x 0.

PAR30S GU W OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE

Orb Optronix, Inc th Ave Kirkland, WA Device Ref #: P20-L360-C27-B25 tel: fax: lm x 0.

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Lumen lm 1 lm= 1cd 1sr The luminous flux emitted into unit solid angle (1 sr) by an isotropic point source having a luminous intensity of 1 candela

Basic lighting quantities

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

57-100W-XXK-WPH12-SG W-40K-WPH12-SG W-57K-WPH12-SG

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

LM Test Report. for. Philips (China) Investment Co., Ltd. InstantFit LEDtube Model:

Report No.: HZ a/R2. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Report No.: EASZE Page 2 of 14

Report No.: HZ h/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

Eternal Shine Technology Co.,Ltd. EST

True energy-efficient lighting: the fundamentals of lighting, lamps and energy-efficient lighting

(Lumens) Stabilization Time CRI (K) (Light & Power) Table 1 Executive Data Summary

LM Test Report

OUTPUT RANGE: VIVID SERIES OUTPUT RANGE: BRILLIANT SERIES COLOR TEMPERATURE RANGE. Form Factor Operating Temperature Electrical Dimming and Flicker

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

SpecSheet_AR111_18.5W_VIVID UND BRILLIANT 2 SpecSheet_AR111_12.5W_VIVID UND BRILLIANT 7 SpecSheet_AR111_6W_VIVID UND BRILLIANT 12

Report No.: HZ k/R1. (Lumens) Stabilization Time CRI (K) (Light & Power) Table 1: Executive Data Summary

Photometric Test Report

LM Test Report

LM Test Report. for EiKO Global, LLC. 25W Floodlight Model: FLM-2C-N-U

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. For. LED2 Lighting Group, Inc. (Brand Name: LED2) 600 Minnesota Ave, Kansas City, KS 66101

NVLAP LAB CODE LM Test Report. Outdoor Full-Cutoff Wall-mounted Area Luminaires. Model name(s): LWA-50W

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires

LM-79 Test Report. Electrical and Photometric tests as required by IESNA LM-79 test standard

LM Test Report

Photometric Test Report

NVLAP LAB CODE LM Test Report. For DONGGUAN THAILIGHT SEMICONDCTOR LIGHTING CO.,LTD. (Brand Name: THAILIGHT)

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

Report No.: HZ w. Stabilization Time (Light & Power) CRI. Table 1: Executive Data Summary. Figure 1- Overview of the sample

NVLAP LAB CODE LM Test Report. For. Shenzhen OKT Lighting Co.,LTD. (Brand Name: OKT LIGHTING)

Sample Report. IES LM Test Report. LED Lamp 001. Test results reported for: Orb Optronix report: LEDC WG. Original issue date:

Report No.: HZ f. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

Catalog Number UPC Number LED Spot Bullet Flood Light 42W 4204 Lumens White

Photometric Test Report

RoHS QPL ID # PNZ72BAB

RoHS QPL ID # PNZ72BAB

LED Slim Panel 48 W PRODUCT DATA SHEET

Cat# 71146A 150W Trunion Mount

Address: IES LM Luminaire Description: Indoor High Bay Light Source: LGIT 5630 Ballast/Driver: VPL Overdrive L320HBL46DIM/50K

RoHS VAC 50/60HZ 0.38A Max W PF LM LM/W x 90

RoHS. Dimming: PWM/VR/0-10V QPL ID # PL21D5Q1B95E. Cat# W FlatPanel Pole Mount. EPA Rating 2.33ft 2.

NVLAP LAB CODE LM Test Report. Outdoor Non-Cutoff and Semi-Cutoff Wall-mounted Area Luminaires. Model name(s): WML-50W

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

LM Test Report. For. Revolution Lighting Technologies, Inc. (Brand Name: ) 2280 Ward Ave. Simi Valley, CA

Report No.: HZ j. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. For. Builders Pack. ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

RoHS QPL ID # PLC6V1PABNUJS

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

LM Test Report. For. GREEN LOGIC LED ELECTRICAL SUPPLY INC (Brand Name: GLLUSA) Shenfubao Industry Park, Bonded area, Futian District,Shenzhen

Photometric Test Report

LM Test Report. For. Eternal Shine Technology Co.,Ltd. (Brand Name: EST) ShenFuBao Industry Park,Bonded area,futian District,Shenzhen,China

NVLAP LAB CODE LM Test Report For. Outdoor Pole/Arm-mounted Area and Roadway Luminaires

NVLAP LAB CODE LM Test Report. For GREEN LOGIC LED ELECTRICAL SUPPLY INC. Outdoor Full-Cutoff Wall-mounted Area Luminaire

Report No.: HZ h. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

LM Test Report. For FALKOR INDUSTRY INC. (Brand Name: Falkor Lighting) 5580 Bandini Blvd Bell,CA USA

Cat# LED High Bay

Properties of LED considering museum lighting

REVOLUTION LIGHTING TECHNOLOGIES INC

Radiometric and Photometric Measurements with TAOS PhotoSensors

Morris Products 53 Carey Road, Queensbury, NY 12804

71352A QPL ID # PLT2P2L2UNWR. RoHS

LM Test Report. for Maxlite Inc. LED Canopy Model: MLCAN20LED50

PARATHOM PAR ADV 5.3 W/827 GU10

Morris Products 53 Carey Road, Queensbury, NY 12804

RoHS. Model: VAC 50/60HZ 0.127A Max 14.6 W PF LM LM/W x90 Aluminium Housing + Polycarbonate Lens

71345A. 50W LED Floodlight Yoke(Bracket) Mount. RoHS QPL ID # PLDUWHES4P5Q. Model: 71345A

NFMS THEORY LIGHT AND COLOR MEASUREMENTS AND THE CCD-BASED GONIOPHOTOMETER. Presented by: January, 2015 S E E T H E D I F F E R E N C E

Transcription:

Led Spot MR16 10W Cold White by CDE Technology BV Page 1 of 19

Summary measurement data parameter Color temperature Luminous meas. remark result 5807 K Cold white 308 Cd intensity I v Beam angle 66 deg Power P 10.1 W Power Factor 0.64 For every 1 kwh net power consumed, there has been 1.2 kvahr for reactive power. Luminous flux 333 Lm Luminous 33 Lm/W efficacy CRI_Ra 78 Color Rendering Index. Coordinates x=0.3258 chromaticity and diagram y=0.3394 Fitting 230V It uses a current driver for the leds, converting 230 V mains into current. PAR-value 2.9 The number of photons seen by an average plant µmol/s/m 2 when it is lit by the light of this light bulb. Value valid at 1 m distance from light bulb. S/P ratio 2.0 This factor indicates the amount of times more efficient the light of this light bulb is perceived under scotopic circumstances (ow environmental light level). D x H external 50 x 72 mm External dimensions of the light bulb. dimensions D luminous area 46 mm Dimensions of the luminous area (used in Eulumdat file). This is equal to the ID of the reflector end at the front of the light bulb. Page 2 of 19

General remarks The ambient temperature during the whole set of measurements was 23.5-25 deg C. Warm up effect: during the warm up time the illuminance decreased with 9 % and the consumed power decreased with 4 %. Voltage dependency: the power consumption and illuminance do not vary when the voltage is varied from 200-250 V. The dim-function of the current driver is tested. The three pre-sets seem to work well. This article contains some additional photos at the end. Page 3 of 19

Overview table Lamp measurement report 30 Oct 2009 The overview table is explained on the OliNo website. Please note that this overview table makes use of calculations, use this data with care as explained on the OliNo site. Eulumdat light diagram This light diagram below comes from the program Qlumedit, that extracts these diagrams from an Eulumdat file. It is explained on the OliNo site. The light diagram giving the radiation pattern. It indicates the luminous intensity around the light bulb. This light bulb has the same Page 4 of 19

light diagram for the C0-C180 as for the C90-C270 plane since it has symmetry over is height axis. Illuminance Ev at 1 m distance, or luminous intensity Iv Herewith the plot of the averaged luminous intensity Iv as a function of the inclination angle with the light bulb. The radiation pattern of the light bulb. This radiation pattern is the average of the light output of the light diagram given earlier. Also, in this graph the luminous intensity is given in Cd. These averaged values are used (later) to compute the lumen output. Page 5 of 19

Intensity data of every measured turn angle at each inclination angle. This plot shows per inclination angle the intensity measurement results for each turn angle at that inclination angle. There normally are differences in illuminance values for different turn angles. However for further calculations the averaged values will be used. When using the average values per inclination angle, the beam angle can be computed, being 66 degrees. This is the average value but as the light bulb has a symmetry over its height axis, this angle is valid for all turn-angles the light bulb is looked at. Luminous flux With the averaged illuminance data at 1 m distance, taken from the graph showing the averaged radiation pattern, it is possible to compute the luminous flux. The result of this computation for this light spot is a luminous flux of 333 Lm. Luminous efficacy The luminous flux being 333 Lm, and the power of the light bulb being 10.1 W, yields a luminous efficacy of 33 Lm/W. A power factor of 0.64 means that for every 1 kwh net power consumed, a reactive Page 6 of 19

component of 1.2 kvar was needed. Light bulb voltage (used on power supply!) 230 VAC Light bulb current 69 ma Power P 10.1 W Apparent power S 15.8 VA Power factor 0.64 Of this light bulb the voltage across ad the resulting current through it+its constant current driver power supply are measured and graphed. See the OliNo site how this is obtained. Voltage across and current through the lightbulb The current does not have a sinusiodal form. It contains some peaks instead. The phase is about the same as the voltage. All together the powerfactor is relatively low with less than 0.7. Also the power spectrum of the current is determined. Page 7 of 19

Current power spectrum in % of the first harmonic (50 Hz). The peaks in the current result in the appearance of the higher harmonics. Page 8 of 19

Color temperature and Spectral power distribution The spectral power distribution of this light bulb, energies on y-axis valid at 1 m distance. The measured color temperature is about 5800 K which is cold white. This color temperature is measured straight underneath the light bulb. Below a graph showing the color temperature for different inclination angles. Page 9 of 19

Color temperature as a function of inclination angle. The measurement of CCT has been stopped when less than 5 lux (low illumination value) was measured or when the inclination angle was 90 degrees. With this lamp at 77.5 degree inclination angle less than 5 lux was measured (at the specific measurement distance). The maximum beam angle is 66 degrees, meaning at an inclination angle of 33 degrees there is 50 % left of the initial illuminance value at 0 degrees. Most of the light energy is within this area. In this area the color temperature stays within 2 % of its value at 0 degrees inclination angle. Page 10 of 19

PAR value and PAR spectrum To make a statement how well the light of this light bulb is for growing plants, the PARarea needs to be determined. See the OliNo website how this all is determined and the explanation of the graph. The photon spectrum, then the sensitivity curve and as result the final PAR spectrum of the light of this light bulb The PAR number for this light results in 2.9 µmol/s/m 2. This value is valid at 1 m distance from the light bulb and valid roughly inside its beam angle. The PAR efficiency is 63 % (valid for the PAR wave length range of 400-725 nm). So maximally 63 % of the total of photons in the light is effectively used by the average plant (since the plant might not take 100 % of the photons at the frequency where its relative sensitivity is 100 %). Page 11 of 19

S/P ratio The S/P ratio and measurement is explained on the OliNo website. Here the results are given. The power spectrum, sensitivity curves and resulting scotopic and photopic spectra (spectra energy content defined at 1 m distance). The S/P ratio is 2.0. More info will come in a separate article. Page 12 of 19

Chromaticity diagram The chromaticity space and the position of the lamp s color coordinates in it. The light coming from this lamp is close to the Planckian Locus (the black path in the graph). Its coordinates are x=0.3258 and y=0.3394. Page 13 of 19

Color Rendering Index (CRI) or also Ra Herewith the image showing the CRI as well as how well different colors are represented (rendered). The higher the number, the better the resemblance with the color when a black body radiator would have been used (the sun, or an incandescent lamp). Each color has an index Rx, and the first 8 indexes (R1.. R8) are averaged to compute the Ra which is equivalent to the CRI. CRI of the light of this light bulb. The value of 78 is (a bit) lower than 80 which is considered a minimum value for indoor usage. Note: the chromaticity difference is 0.001 indicates the distance to the Planckian Locus. Its value is lower than 0.0054, which means that the calculated CRI result is meaningful. Voltage dependency The dependency of a number of lamp parameters on the lamp voltage is determined. For this, the lamp voltage has been varied and its effect on the following light bulb parameters measured: illuminance E_v [lx], the lamppower P [W], the (Correlated) Color Temperature [K] and the luminous efficacy [Lm/W]. Page 14 of 19

Lamp voltage dependencies of certain light bulb parameters, where the value at 230 V is taken as 100 %. The consumed power varies < 2 % and the illuminane doesn t vary when the voltage varies between 200-250 V. This variation is insignificant. When the voltage at 230 V varies with + and - 5 V, then the illuminance varies within 0.1 %, so when abrupt voltage changes occur this effect is not visible in the illuminance output. Warm up effects After switch on of a cold lamp, the effect of heating up of the lamp is measured on illuminance E_v [lx], color temperature CT or correlated color temperature CCT [K], the lamppower P [W] and the luminous efficacy [lm/w]. Page 15 of 19

Effect of warming up on different light bulb parameters. At top the 100 % level is put at begin, and at bottom at the end. Page 16 of 19

The warm-up time is about 25 minutes. During this time the illuminance value and the consumed power decrease with 9 % and 4 % respectively. The small variations in illuminance at the end of the measurement time come from the variations in ambient temperature (23.5-25 ºC). Dim-functionality The used current source enables dimming the connected light bulbs by switching off and on within 2 seconds. The dim-presets are 100 %, 33 % and 66 %. Lamp parameters dependent on the dim-position The consumed power and the illuminance values are nicely linear with the dim-presets; the illuminance follows the specified 33 %, 67 % and 100 % levels. The consumed power decreases only marginally slower than the illuminance does. The color temperature decreases slightly when dimming takes place. Page 17 of 19

Additional photos Lamp measurement report 30 Oct 2009 Close up of the LED inside the lamp reflector Page 18 of 19

Side view of the light bulb The used current driver This is a very versatile current driver: the constant current can be set with dip-switches. During this lamp measurement it was set to 800 ma. Then it can be connected to a (remote) dimmer. It also enables dimming with three presets when switching off and on within 2 seconds, as explained before and which is tested in this article. Disclaimer The information in this OliNo report is created with the utmost care. Despite of this the information can have inaccuracies. OliNo cannot be held liable for the content of the information in this report nor for the consequences of its use. The data in this report is not legally binding. Page 19 of 19