National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Similar documents
1 Exam Prep NFPA 70: National Electric Code 2011 Tabs and Highlights

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Wisconsin Contractors Institute Continuing Education

CONTINUING EDUC ATION

NEC 2014 Code Changes

2017 NEC TABLE OF CONTENTS

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

MEMORANDUM. National Fire Protection Association

Part VIII Electrical GENERAL REQUIREMENTS CHAPTER 33

Article 700: Emergency Systems. 2.! Audible and visual signal devices shall be provided, where practicable to indicate.

Article 225: Outside Branch Circuits And Feeders

American Electrical Institute

GENERAL SUBSCRIBER SERVICES TARIFF Pembroke Telephone Company, Inc. Third Revised Contents Sheet 1 Cancels Second Revised Contents Sheet 1

NEC P14 First Draft Ballot (A2016)

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

Article 250 Grounding & Bonding

National Fire Protection Association M E M O R A N D U M. Technical Committee on Initiating Devices for Fire Alarm and Signaling Systems

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

NOTICE OF RULE MAKING PROCEEDINGS AND PUBLIC HEARING

FTTH ENGINEERING AND INSTALLATION INTRODUCTION

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

2014 NEC Changes Part 1

Wiring Methods, Components, and Equipment for General Use -- OSHA Standard

RADIO AND TELEVISION SATELLITE EQUIPMENT

Journeyman's Practice Exam

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

HELUKABEL UL-LISTED CABLES

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

A. Product Data: For each electrical identification product indicated.

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

A. Product Description: Stranded conductor insulated wire.

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Code Check Electrical is a field guide to common code issues in residential

ELECTRIC GROUNDING AND WIRING REQUIREMENTS BOOTHS-METAL

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

SECTION ELECTRICAL IDENTIFICATION

Continued from Part 1 Rules 1 25.

M E M O R A N D U M. NFPA 101A First Draft Correlating Committee FINAL Ballot Results (A2018)

M E M O R A N D U M. NFPA Technical Committee on Assembly Occupancies and Membrane Structures. NFPA 101 ROP Letter Ballot Circulation

Second Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 12/12/ :15 AM

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

CHAPTER 2 Wiring and Protection. Article 200 Use and Identification of Grounded Conductors

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

SECTION BUILDING WIRE AND CABLE

2. Electrical rooms shall be centrally located and stacked so that feeder conduits and bus duct are run as straight and short as possible.

SUBJECT: NFPA 70 Second Draft TC Ballot Final Results (A2016)

UNION COUNTY ENGINEER DIVISION OF BUILDING REGULATIONS

ELPT 1429 RESIDENTIAL WIRING

I dedicate this book to the Lord Jesus Christ, my mentor and teacher. Proverbs 16:3 NOTICE TO THE READER ABOUT THE AUTHOR

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

AGENDA. NEC Code-Making Panel 5. Report on Comment Meeting. November 28-December 1, Redondo Beach, CA

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

ELECTRICAL GENERAL DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Electrical/Telecommunications Design

Continuing Education, For UDC Electrical Inspectors, Commercial Electrical Inspectors, Master Electricians and Journeyman Electricians.

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

MEMORANDUM. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

Electrical IP Red Seal Practice Exam

03/7/12 Issuance UTD Section Page 1 of 5 Electrical General

FINAL - ER 70 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes

Electrical Standards Division 16

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

SECTION ELECTRICAL IDENTIFICATION

4. Special Systems Design: including Fire Alarm and Security. C. Electrical and Telecommunications Ductbanks: Refer to Section 16118

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

SECTION COMMUNICATIONS COPPER OSP CABLING

M E M O R A N D U M. NFPA Technical Committee on Electrical Equipment of Industrial Machinery

First Revision No. 112-NFPA [ Global Input ] Submitter Information Verification. Committee Statement and Meeting Notes 1/14/2015 1:57 PM

National Radio Astronomy Observatory Socorro, NM EVLA Memorandum 41 Lightning Protection for Fiber Optic Cable. T. Baldwin June 05, 2002

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

Suggested Statement/Substantiation for The PoE Task Group PIs

Paul Dobrowsky Innovative Technology Services

Overview of Grounding for Industrial and Commercial Power Systems Presented By Robert Schuerger, P.E.

B. Manufacturers: Square-D, G.E. or Westinghosue.

EPG. by Chris C. Kleronomos

Section 2 Installation

SECTION DISTRIBUTION SWITCHBOARDS

Copper Sheathed Cable Sheath Currents

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

Jake Leahy s Electrical Code Connection. A look at Grounding and Bonding of Electrical Services Article Florida Building Code 5 th Edition

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

We have 3 ways to help you prepare

Communications Integrators, Inc. June S. Wilson Street, Suite 105 Tempe, Arizona Toll Free (800) Web Site

Electrical Wiring: Commercial, Seventh Canadian Edition

Grounding and Bonding of Service Equipment

CIR (Crush & Impact Resistant) VFD Power Cable

AN EXAMPLE OF A STANDARD ARC FLASH PPE LABELING STRATEGY

12.6 Delta Phase versus Line Current

14 AWG 2 AWG: 600 Volt

Surge Protection and Grounding Issues

Busbar and Modular Wiring Systems

SECTION DISTRIBUTION SWITCHBOARDS

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

Transcription:

National Fire Protection Association 1 Batterymarch Park, Quincy, MA 02169-7471 Phone: 617-770-3000 Fax: 617-770-0700 www.nfpa.org M E M O R A N D U M TO: Members of the NEC-Code Making Panel 16 FROM: Jean O Connor DATE: February 28, 2011 SUBJECT: NFPA 70 ROP TC Circulation Ballot (A2013 Cycle) The February 24, 2012 date for receipt of the NFPA 70 ROP letter ballot has passed. In accordance with the NFPA Regulations Governing Committee Projects, the attached circulation report contains the number of members eligible to vote, the names of principals whose ballots were not returned, and the reasons for negative votes for your review so you may change your ballot if you wish. Abstentions and affirmative comments are also included. If you wish to change your vote, the change must be received at NFPA as soon as possible, however, no later than Thursday, March 8, 2012. Members who have not returned a ballot may do so at this time. Ballots or ballot changes should be sent to Jean O Connor via either e-mail to joconnor@nfpa.org or via fax to 617-984-7070. You may also mail your changes to the attention of Jean O Connor at NFPA, 1 Batterymarch Park, Quincy, MA 02169. The return of ballots is required by the Regulations Governing Committee Projects. Attachment: Circulation Explanation Report

1 16-1 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 Entire Document (Log # 1170o ) Affirmative with Comment Brunssen, J. The terms buildings and buildings and structures are appropriately applied throughout Article 770 and Chapter 8. 16-2 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 Entire Document (Log # 921o ) 16-3 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Burial Cover (New), 300.5, 680.10, 830.47, and 840.47 (Log # 1342a ) 16-3a Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Cable Routing Assembly (Log # 1623a ) 16-4 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Cable Routing Assembly (New) and 770.2 (Log # 2776 ) 16-5 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Coaxial Cable (New) and 820.2 (Log # 1732 ) 16-6 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Communication Equipment (Log # 616 ) 16-7 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Communications Circuit (New) and 800.2 (Log # 1730 )

2 16-8 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Communications Raceway (New) and 800.2 (Log # 1731 ) 16-9 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Composite Optical Fiber Cable (New) and 770.2 (Log # 1727 ) 16-10 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Conductive Optical Fiber Cable (New) and 770.2 (Log # 1726 ) 16-11 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Network-Powered Broadband Communications Circuit (New) and 830.2 (Log # 1733 ) 16-12 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Non-Power-Limited Fire Alarm Circuit (NPLFA) (New) and 770.2 (Log # 2774 ) 16-13 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Nonconductive Optical Fiber Cable (New) and 770.2 (Log # 1728 ) 16-14 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Optical Fiber Cable (New) and 770.2 (Log # 1729 )

3 16-15 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Optical Fiber Raceway (New) and 770.2 (Log # 2777 ) 16-16 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Point of Entrance (New) and 770.2, 770.48(A), 770.100(E), and Table 770.154(A) (Log # 1715 ) 16-17 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Point of Entrance (New) and 800.2 (Log # 1717 ) 16-18 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Point of Entrance (New) and 820.2 (Log # 1719 ) 16-19 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 100.Point of Entrance (New) and 830.2 (Log # 1720 ) 16-20 Eligible To Vote:16 Affirmative: 14 : 1 Abstain: 0 : 1 770 (Log # 901 ) Johnson, S. Article 770 deals with optical fiber cables. These cables have little to do with electrical installations and have more in common with Articles 800, 820, 830, and 840 installations. For this reason, it is appropriate that Article 770 be moved into Chapter 8 with other telecommunications related installations. 16-21 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770, Informational Note (Log # 627 )

4 16-22 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2 (Log # 194 ) 16-23 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2 and 800.2 (Log # 707 ) 16-24 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2 (Log # 2317 ) 16-25 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2.Abandoned Optical Fiber Cable (Log # 190 ) 16-26 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2.Cable Routing Assembly (Log # 164 ) 16-26a Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2.Electrical Circuit Protective System, 770.179(E) (Log # CP1601 ) 16-27 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2.Exposed (to Accidental Contact) (Log # 191 ) 16-28 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2. Innerduct (Log # 192 )

16-29 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2.Optical Fiber Cable (Log # 621 ) 16-30 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2.Optical Fiber Cable (Log # 916 ) Affirmative with Comment Brunssen, J. Based upon the Panel Action on Proposals 16-29 and 16-30 the definition of Optical Fiber Cable should now read: "Optical Fiber Cable. A factory assembly or field assembly of one or more optical fibers having an overall covering." The comma following 'optical fibers' is unnecessary. 16-31 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2. Point of Entrance (Log # 193 ) 16-32 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2.Point of Entrance (Log # 1716 ) 16-33 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2. Point of Entrance (Log # 2159 ) 16-34 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.2.Point of Entrance 16-35 Eligible To Vote:16 Affirmative: 14 : 1 Abstain: 0 : 1 770.3 (Log # 434 ) 5

Dorna, G. The panel determined that the submitter s substantiation was insufficiently detailed. It wrote To ensure that this change will not impact this article will take a review of the Chapters 1, 3, and 4 to determine that all applicable sections have been referenced in Article 770. Let s expand the detail of submitter s substantiation to the level of a review of Chapters 1, 3 and 4 Chapter 1 The submitter s statement about Chapter 1 is: Chapter 1, General has two parts that apply to optical fiber cables and raceways, definitions in Article 100 and the requirement to use and install listed and labeled equipment in accordance with the manufacturer s instructions are referenced Article 770. The rest of Chapter 1 is not needed for optical fiber cable and raceway installations. The table below is a detailed analysis of Chapter 1. Article Applies to Article 770? Observation 100 Definitions Part I General yes Part II Over 600 Volts- No 770.2 references Article 100. Panel action on proposal 16-27 narrows the reference to Part I of Article 100 110 Requirements for Electrical Installations No The title of the article clearly omits optical fiber cables. Likewise, the scope is clear about covering only electrical conductors. Clearly, only Part I of Article 100 applies to Article 100 and it is already referenced in 770.2, so nothing is lost by exempting Article 770 from Article 100. Chapter 4 The title of Chapter 4 is Equipment for General Use ; clearly the equipment is electrical equipment. Let s review chapter 4 in detail in the table below: Article Applies to Article 770? 400 Flexible Cords and Cables No 402 Fixture Wires No 404 Switches No 406 Receptacles, Cord Connectors, and Attachment Plugs (Caps) No 408 Switchboards and Panelboards No 409 Industrial Control Panels No 410 Luminaires, Lampholders, and Lamps No 411, Lighting Systems Operating at 30 Volts or Less No 422 Appliances No 424 Fixed Electric Space-Heating Equipment No 426 Fixed Outdoor Electric Deicing and Snow-Melting Equipment No 427 Fixed Electric Heating Equipment for Pipelines and Vessels No 430 Motors, Motor Circuits, and Controllers No 440 Air-Conditioning and Refrigerating Equipment No 445 Generators No 450 Transformers and Transformer Vaults (Including Secondary Ties) No 455 Phase Converters No 460 Capacitors No 470 Resistors and Reactors No 480 Storage Batteries No 490 Equipment, Over 600 Volts, Nominal No Each of the Articles in Chapter 4 covers a deferent type of electrical equipment and none of the Articles in Chapter 4 applies to Article 770. Chapter 3 In the current edition of the Code, only those sections of Article 300 apply to Article 770. The submitter states: Article 770 has references to 300.22 for installations in air-handling spaces and it has references to Chapter 3 for the installation of raceways. The table below is a detailed analysis of Chapter 3 (other than Article 300). Article Applies to Article 770? Observation 310 Conductors for General Wiring No 312 Cabinets, Cutout Boxes, and Meter Socket Enclosures No 314 Outlet, Device, Pull, and Junction Boxes; Conduit Bodies; Fittings; and Handhole Enclosures Yes 770.110(A)(1) already requires that the installation of Chapter 3 raceways comply with the applicable requirements of Chapter 3. 320 Armored Cable: Type AC No 322 Flat Cable Assemblies: Type FC No 324 Flat Conductor Cable: Type FCC No 326 Integrated Gas Spacer Cable: Type IGS No 328 Medium Voltage Cable: Type MV No 330 Metal-Clad Cable: Type MC No 332 Mineral-Insulated, Metal-Sheathed Cable: Type MI No 334 Nonmetallic-Sheathed Cable: Types NM, NMC, and NMS No 336 Power and Control Tray Cable: Type TC No 338 Service-Entrance Cable: Types SE and USE No 6

7 340 Underground Feeder and Branch-Circuit Cable: Type UF No 342 Intermediate Metal Conduit: Type IMC Yes 770.110(A)(1) already requires that the installation of Chapter 3 raceways comply with the applicable requirements of Chapter 3. 344 Rigid Metal Conduit: Type RMC Yes 348 Flexible Metal Conduit: Type FMC Yes 350 Liquidtight Flexible Metal Conduit: Type LFMC Yes 352 Rigid Polyvinyl Chloride Conduit: Type PVC Yes 353 High Density Polyethylene Conduit: Type HDPE Conduit Yes 354 Nonmetallic Underground Conduit with Conductors: Type NUCC Yes 355 Reinforced Thermosetting Resin Conduit: Type RTRC Yes 356 Liquidtight Flexible Nonmetallic Conduit: Type LFNC Yes 358 Electrical Metallic Tubing: Type EMT Yes 360 Flexible Metallic Tubing: Type FMT Yes 362 Electrical Nonmetallic Tubing: Type ENT Yes 366 Auxiliary Gutters Yes 368 Busways No 370 Cablebus No 372 Cellular Concrete Floor Raceways Yes 770.110(A)(1) already requires that the installation of Chapter 3 raceways comply with the applicable requirements of Chapter 3. 374 Cellular Metal Floor Raceways Yes 376 Metal Wireways Yes 378 Nonmetallic Wireways Yes 380 Multioutlet Assembly No 382 Nonmetallic Extensions No 384 Strut-Type Channel Raceway Yes 770.110(A)(1) already requires that the installation of Chapter 3 raceways comply with the applicable requirements of Chapter 3. 386 Surface Metal Raceways Yes 388 Surface Nonmetallic Raceways Yes 390 Underfloor Raceways Yes 392 Cable Trays Yes 394 Concealed Knob-and-Tube Wiring No 396 Messenger-Supported Wiring No 398 Open Wiring on Insulators No 399 Outdoor Overhead Conductors over 600 Volts No The detailed analysis shows that the use of Chapter 3 raceways is already covered in 770.110(A)(1) and the installation is required to comply with Chapter 3 so nothing would be lost if the raceway articles were not directly applicable to Article 770. The numerous electrical cable articles have no relevance to Article 770. Article 770 permits installation of optical fiber cables in cable trays; see 770.113 and 770.133. Article 770 has no requirements for the installation of cable trays and the installation requirements of Article 392 would be lost. This analysis, therefore, leads to the conclusion that this proposal should be accepted in part and the addition of all of Chapter 3 should be rejected. Therefore, the introductory paragraph of 770.3 should be changed to read: Installations of optical fiber cables and raceways shall comply with 770.3(A) and (B). Only those sections of Chapters 1, 2 and 4 and Article 300 referenced in this article shall apply to optical fiber cables and raceways. 16-36 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.3(B) (New) (Log # 429 ) 16-37 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.3(C) (New) (Log # 708 )

8 16-38 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.12 (Log # 709 ) 16-38a Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.12.Innerduct for Optical Fiber Cable (Log # CP1600 ) 16-39 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.24 (Log # 436 ) 16-40 Eligible To Vote:16 Affirmative: 9 : 6 Abstain: 0 : 1 770.24 (Log # 1572 ) Brunssen, J. The "Regulations Governing Committee Projects" state in Section 4-3.3 (d) that proposals shall include a 'statement of the problem and substantiation for Proposal'. The submitter has identified neither a fire nor an electrical safety hazard to warrant expanding the requirements of 770.24. The requirements of 300.4 are intended to promote fire and electrical safety where electrical cables containing significant voltage and available current are run within walls, floors and ceilings. Hazards may result when nails, screws or other fasteners are driven into the wall, floor or ceiling should they puncture the electrical cable. Optical fiber cables are much smaller (approximately 1/8 inch in diameter) than power cables, contain no power, and do not pose a fire or electrical safety hazard. Support of cables is presently addressed in 300.4(D). Deike, Jr., R. Optical Fiber should not be held to the same installation requirements as electrical cable. There was no substantiation provided to document that fiber optic cable presents the same level of hazard to personnel or property that electrical cable does. The level of protection required for the fiber optic cable should be determined by the end user. Dorna, G. The submitter s assertion that optical fiber cables need to be protected when installed other-then-parallel to framing members is totally unsubstantiated. Likewise the submitter s assertion that optical fiber cables require support when installed behind accessible panels is not substantiated. These no-voltage cables present no shock hazard and unlike electric power cables, they cannot initiate a fire. Article 770 already addresses the only hazard that optical fiber cables present, the hazard from the spread of fire. Ivans, R. This proposal should be Rejected. Optical fiber and communications circuits are not required to be protected the same as power, Class 1, or life safety circuits, therefore adding all the subsections in 300.4 is unnecessary. Section 90.1(A) states the purpose of the NEC is practical safe guarding of persons and property from hazards arising from the use of electricity. The requirements of 300.4 are intended to protect cables containing voltage and available current that present the risk of fire or electrical shock. Where there is only signal power, limited power or no power at all (optical fiber) in the cable, there is no reason to add excessive requirements. Johnson, S. The workmanship requirements for optical fiber cables are not the same as those required for high voltage conductors. The safety and shock hazards present in power carrying cables are not present in these types of cables. The submitter's substantiation has not shown that adding these more stringent requirements are necessary from a safety standpoint. Prezioso, L. The proposal failed to present sufficient substantiation for the added requirements and any fire or electrical safety issues that would be remedied by the change.

9 16-41 Eligible To Vote:16 Affirmative: 9 : 6 Abstain: 0 : 1 770.24 (Log # 3139 ) Brunssen, J. The "Regulations Governing Committee Projects" state in Section 4-3.3 (d) that proposals shall include a 'statement of the problem and substantiation for Proposal'. The submitter has identified neither a fire nor an electrical safety hazard to warrant expanding the requirements of 770.24. The requirements of 300.4 are intended to promote fire and electrical safety where electrical cables containing significant voltage and available current are run within walls, floors and ceilings. Hazards may result when nails, screws or other fasteners are driven into the wall, floor or ceiling should they puncture the electrical cable. Optical fiber cables are much smaller (approximately 1/8 inch in diameter) than power cables, contain no power, and do not pose a fire or electrical safety hazard. Support of cables is presently addressed in 300.4(D). Deike, Jr., R. Optical Fiber should not be held to the same installation requirements as electrical cable. There was no substantiation provided to document that fiber optic cable presents the same level of hazard to personnel or property that electrical cable does. The level of protection required for the fiber optic cable should be determined by the end user. Dorna, G. See my explanation of Vote on Comment 16-40. Ivans, R. This proposal should be Rejected. Optical fiber and communications circuits are not required to be protected the same as power, Class 1, or life safety circuits, therefore adding all the subsections in 300.4 is unnecessary. Section 90.1(A) states the purpose of the NEC is practical safe guarding of persons and property from hazards arising from the use of electricity. The requirements of 300.4 are intended to protect cables containing voltage and available current that present the risk of fire or electrical shock. Where there is only signal power, limited power or no power at all (optical fiber) in the cable, there is no reason to add excessive requirements. Johnson, S. See my Explanation of Vote on Proposal 16-40. Prezioso, L. See my Explanation of on Proposal 16-40 (Log #1572). 16-42 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.24 (Log # 3358 ) Affirmative with Comment Ivans, R. I agree with panel action to Accept In Part with further substantiation. It is appropriate to align with NFPA 90A. Cable ties are listed under the UL certification category for Positioning Devices (ZODZ) for this purpose. 16-43 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.24, Informational Note 1 (Log # 822 ) 16-44 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.24, Informational Note 2 (Log # 435 )

16-45 Eligible To Vote:16 Affirmative: 14 : 1 Abstain: 0 : 1 770.26 (Log # 710 ) Dorna, G. The current text uses the term optical fiber cables and raceways twice. The panel statement that raceways are required to be fire stopped is undisputable but is based on a misreading of the text. The raceways the submitter recommends deleting are optical fiber raceways not raceways in general. The fire stopping of raceways is covered by 300.21. Article 770 already requires the fire stopping of Chapter 3 raceways; see 770.110(A)(1). It should be noted that 830.26 does not mention raceways because there are no raceways unique to that Article. There are (or were) optical fiber raceways, communications raceways and CATV raceways; there are no network-powered-broadband raceways. Since the panel accepted the use of communications raceways in place of optical fiber raceways, it could have accepted the proposal in principle and changed optical fiber cables and raceways to optical fiber cables and communications raceways just as it did in its action to accept proposal 16-169 in principle. If the panel had accepted proposals 16-45 and 16-169, the fire stopping of communications raceways would still be required by 800.26. Affirmative with Comment Ohde, H. We agree with the panel action and panel statement that all raceways are required to be fire stopped. It does not matter if the raceway is a communication raceway or any other type of raceways. All electrical installations in these areas need to be fire stopped to prevent the possible spread of fire or products of combustion. 16-46 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.47 (New) (Log # 437 ) 16-47 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.48(B) (Log # 438 ) 16-48 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.49 (New) (Log # 195 ) Affirmative with Comment Ohde, H. We agree with the panel action however believe that that is a grounding requirement and does not belong as 770.49 in Part II Cables Outside and Entering Buildings. This grounding requirement would be best suited somewhere in Part IV Grounding Methods. 16-49 Eligible To Vote:16 Affirmative: 14 : 1 Abstain: 0 : 1 770.93(B) (New) (Log # 196 ) 10

11 Ohde, H. There is no need for this Informational Note as it is unwarranted and not necessary. A Code-user is going to know that the terms that are defined in 770.2 which includes "Point of Entrance" applies throughout the entire Article 770. 16-50 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.100(A)(4) (New) (Log # 430 ) 16-51 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.100(A)(5) (Log # 623 ) 16-52 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.100(B)(1) (Log # 197 ) 16-53 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.100(B)(1) (Log # 624 ) 16-54 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.100(B)(3)(1) (Log # 625 ) 16-55 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.100(B)(3)(2) (Log # 626 ) 16-56 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.100(B)(7) (Log # 2160 )

12 16-57 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.110 (Log # 711 ) Affirmative with Comment Ohde, H. We agree with the panel action and panel statement. Cable Routing Assemblies should have their own installation guidelines set forth as indicated by the panel action on this proposal. 16-58 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.110(A)(2) (Log # 1687 ) 16-59 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.110(C)(3) (Log # 2334 ) 16-60 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.112 (New) (Log # 2318 ) 16-61 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.113 (Log # 74 ) 16-62 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.113 (Log # 712 ) 16-63 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.113, 770.182 (Log # 1627 )

13 16-64 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.113(B)(2) (Log # 2327 ) 16-65 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.113(D) (Log # 75 ) 16-66 Eligible To Vote:16 Affirmative: 14 : 1 Abstain: 0 : 1 770.133 (Log # 1021 ) Deike, Jr., R. It recognized that increasing voltage from 600 volts to 1000 volts may be applicable to specific installations. However, adequate technical substantiation has not been provided to support the change in this Article. 16-67 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.133(B) and (C) (Log # 520 ) 16-68 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.133(C) (Log # 713 ) 16-69 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.133(C) (Log # 714 ) 16-70 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.133(D) (New) (Log # 715 )

14 16-71 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.154 (Log # 737 ) 16-72 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 Table 770.154(a), Informational Note 1 (Log # 2423 ) 16-73 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 Table 770.154(a), Informational Note 1 (Log # 2449 ) 16-74 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 Table 770.154(A) (Log # 76 ) 16-75 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.179 (Log # 915 ) 16-76 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.179, 800.170, 800.179, 800.182, 820.179, 830.15, 830.179, and 840.170(A), Informational Note (Log # 2638f ) 16-77 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.179(A), Informational Note (Log # 439 ) 16-78 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.179(A), 800.179(A), 820.179(A), and 830.179(B)(1), Informational Note (Log # 1309 )

15 16-79 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.179(G) (Log # 2105 ) 16-80 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.180 (New) (Log # 1882 ) 16-81 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 770.182 (Log # 716 ) 16-82 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.2 (Log # 203 ) 16-83 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.2 Abandoned Communications Cable, Informational Note (Log # 200 ) 16-84 Eligible To Vote:16 Affirmative: 14 : 1 Abstain: 0 : 1 800.2 Cable (Log # 198 ) Ivans, R. This proposal should be accepted. Communication Cables may be provided with copper conductors with additional optical fiber member(s). These cables are provided with an OF suffix. In addition, 770.3 (B) covering composite optical fiber cables, requires that they be classified as electrical cables in accordance with the type of electrical conductors provided. In the case of communications cables, article 800 would apply. Therefore, the revised definition would better describe such a composite cable. 16-85 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.2 Communications Raceway (Log # 199 )

16 16-85a Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.2.Electrical Circuit Protective System, 800.179(G) (Log # CP1602 ) 16-86 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.2 Exposed (to Accidental Contact), Informational Note (Log # 201 ) 16-87 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.2.Innerduct (New) (Log # 717 ) 16-88 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.2 Point of Entrance (Log # 202 ) 16-89 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.2 Point of Entrance (Log # 628 ) 16-90 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.2.Point of Entrance (Log # 1718 ) 16-91 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.3(C) (Log # 440 ) 16-92 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.3(D) (New) and 800.18 (Log # 441 )

17 16-93 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.3(G) (Log # 718 ) 16-94 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.3(G) (Log # 2778 ) 16-95 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.3(H) (New) (Log # 2106 ) 16-96 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.4(A)(4) (Log # 3130 ) 16-97 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.12 (New) (Log # 442 ) 16-98 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.24 (Log # 1107 ) 16-99 Eligible To Vote:16 Affirmative: 9 : 6 Abstain: 0 : 1 800.24 (Log # 1573 )

18 Brunssen, J. The "Regulations Governing Committee Projects" state in Section 4-3.3 (d) that proposals shall include a 'statement of the problem and substantiation for Proposal'. The submitter has identified neither a fire nor an electrical safety hazard to warrant expanding the requirements of 800.24. The requirements of 300.4 are intended to promote fire and electrical safety where electrical cables containing significant voltage and available current are run within walls, floors and ceilings. Hazards may result when nails, screws or other fasteners are driven into the wall, floor or ceiling should they puncture the electrical cable. Communications cables are typically smaller than power cables (26 AWG copper conductors), operate at power levels of 100 volt-amperes or less derived from a power-limited source, and do not pose a fire or electrical safety hazard. Support of cables is presently addressed in 300.4(D). Deike, Jr., R. Communication circuits and equipment should not be held to the same installation requirements as electrical cable. There was no substantiation provided to document that communication circuits and equipment present the same level of hazard to personnel or property that electrical cable does. The level of protection required for communication circuits and equipment should be determined by the end user. Dorna, G. The submitter s assertion that communications cables need to be protected when installed other-then-parallel to framing members is totally unsubstantiated. Likewise the submitter s assertion that communications cables require support when installed behind accessible panels is not substantiated. Communications cables present minimal shock hazard and unlike electric power cables, they cannot initiate a fire. The uniqueness of communications circuits is recognized by 90.3 which exempts Chapter 8 from the general wiring requirements unless specifically referenced from Chapter 8. The submitter is trying to apply a uniform set of installation rules to power, communications and fiber optics without considering the inherent safety features of communications installations. Ivans, R. This proposal should be Rejected. Optical fiber and communications circuits are not required to be protected the same as power, Class 1, or life safety circuits, therefore adding all the subsections in 300.4 is unnecessary. Section 90.1(A) states the purpose of the NEC is practical safe guarding of persons and property from hazards arising from the use of electricity. The requirements of 300.4 are intended to protect cables containing voltage and available current that present the risk of fire or electrical shock. Where there is only signal power, limited power or no power at all (optical fiber) in the cable, there is no reason to add excessive requirements. Johnson, S. The workmanship requirements for communications cables are not the same as those required for high voltage conductors. The safety and shock hazards present in power carrying cables are not present in these types of cables. The submitter's substantiation has not shown that adding these more stringent requirements are necessary from a safety standpoint. Prezioso, L. See my Explanation of on Proposal 16-40 (Log #1572). 16-100 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.24 (Log # 2945 ) Affirmative with Comment Ivans, R. I agree with panel action to Accept In Part with further substantiation. It is appropriate to align with NFPA 90A. Cable ties are listed under the UL certification category for Positioning Devices (ZODZ) for this purpose. 16-101 Eligible To Vote:16 Affirmative: 9 : 6 Abstain: 0 : 1 800.24 (Log # 3138 ) Brunssen, J. The "Regulations Governing Committee Projects" state in Section 4-3.3 (d) that proposals shall include a 'statement of the problem and substantiation for Proposal'. The submitter has identified neither a fire nor an electrical safety hazard to warrant expanding the requirements of 800.24. The requirements of 300.4 are intended to promote fire and electrical safety where electrical cables containing significant voltage and available current are run within walls, floors and ceilings. Hazards may result when nails, screws or other fasteners are driven into the wall, floor or ceiling should they puncture the electrical cable. Communications cables are typically smaller than power cables (26 AWG copper conductors), operate at power levels of 100 volt-amperes or less derived from a power-limited source, and do not pose a fire or electrical safety hazard. Support of cables is presently addressed in 300.4(D).

19 Deike, Jr., R. Communication circuits and equipment should not be held to the same installation requirements as electrical cable. There was no substantiation provided to document that communication circuits and equipment present the same level of hazard to personnel or property that electrical cable does. The level of protection required for communication circuits and equipment should be determined by the end user. Dorna, G. See my Explanation of Vote on Proposal 16-99. Ivans, R. This proposal should be Rejected. Optical fiber and communications circuits are not required to be protected the same as power, Class 1, or life safety circuits, therefore adding all the subsections in 300.4 is unnecessary. Section 90.1(A) states the purpose of the NEC is practical safe guarding of persons and property from hazards arising from the use of electricity. The requirements of 300.4 are intended to protect cables containing voltage and available current that present the risk of fire or electrical shock. Where there is only signal power, limited power or no power at all (optical fiber) in the cable, there is no reason to add excessive requirements. Johnson, S. See my Explanation of Vote on Proposal 16-99. Prezioso, L. See my Explanation of on Proposal 16-40 (Log #1572). 16-102 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.24, Informational Note 2 (Log # 443 ) 16-103 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.26 (Log # 719 ) Affirmative with Comment Ohde, H. We agree with the panel action but think that all electrical installations in these areas need to be fire stopped to prevent the possible spread of fire or products of combustion. This requirement should not be just be limited to communications cables, communications raceways and cable routing assemblies but should include all electrical installations and equipment. 16-104 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.49 (New) (Log # 204 ) Affirmative with Comment Ohde, H. We agree with the panel action however believe that that is a grounding requirement and does not belong as 800.49 in Part II Cables Outside and Entering Buildings. This grounding requirement would be best suited somewhere in Part IV Grounding Methods. 16-105 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.90(A) and Table 800.154(a), Informational Note 2 (Log # 2424 ) 16-106 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.90(A)(2) and Table 800.154(a) (Log # 2450 )

20 16-107 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.90(B), Informational Note (Log # 629 ) 16-108 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.100, Informational Note (New) (Log # 823 ) 16-109 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.100(B)(1) (Log # 205 ) 16-110 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.100(B)(2)(3) (Log # 444 ) 16-111 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.100(B)(2) (Log # 630 ) 16-112 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.100(B)(3)(1) (Log # 631 ) 16-113 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.100(B)(3)(2) (Log # 2542 )

21 16-114 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.106(A)(1) (Log # 632 ) 16-115 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.106(A)(2) (Log # 633 ) 16-116 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.110 (Log # 720 ) Affirmative with Comment Ohde, H. See our affirmative comment on Proposal 16-57. 16-117 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.110(A)(2) (Log # 1688 ) 16-118 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.113 (Log # 77 ) 16-119 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.113 (Log # 721 ) 16-120 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.113 (Log # 1628 ) 16-121 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.113(B)(2) (Log # 2328 )

22 16-122 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.113(C)(3) (Log # 2331 ) 16-123 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.113(C)(4) and Table 800.154(a) (Log # 371 ) 16-124 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.133(A)(1), 800.133(A)(1)(a), and 800.133(A)(1)(b) (Log # 521 ) 16-125 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.133(A)(1)(b) (Log # 722 ) 16-126 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.133(A)(1)(b) (Log # 723 ) 16-127 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.133(A)(1)(c) (New) (Log # 724 ) 16-128 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.133(A)(2) (Log # 1839 )

23 16-129 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.133(A)(2) Exception No. 1 (Log # 1750 ) 16-130 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.133(A)(2) Exception No. 1 (Log # 1858 ) 16-131 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.154 (Log # 738 ) 16-132 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.154(A) (Log # 78 ) 16-133 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.154(A) (Log # 2335 ) 16-134 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.170 (Log # 1301 ) 16-135 Eligible To Vote:16 Affirmative: 14 : 1 Abstain: 0 : 1 800.170(C) (New) (Log # 2946 ) Prezioso, L. Proposal contained no evidence that having the existing product "listed" will address any current safety problem or issue. Affirmative with Comment Ivans, R. I agree with panel action to Accept with further substantiation. It is appropriate to align with NFPA 90A. Cable ties are listed under the UL certification category for Positioning Devices (ZODZ) for this purpose.

24 16-136 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.179(A), Informational Note (Log # 446 ) 16-137 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.179(G) (Log # 2107 ) 16-138 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.179(I) (Log # 445 ) 16-139 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.180 (New) (Log # 1883 ) 16-140 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 800.182 (Log # 725 ) 16-141 Eligible To Vote:16 Affirmative: 11 : 4 Abstain: 0 : 1 810.1 (Log # 2950 ) Brunssen, J. Dish antennas are presently covered in the scope of Article 810. The "Regulations Governing Committee Projects" state in Section 4-3.3 (d) that proposals shall include a 'statement of the problem and substantiation for Proposal'. The submitter has identified neither a problem nor substantiated excluding flat or parabolic (dish) antennas of less than 1 meter is diameter (or across) from article 810. Stating that flat or parabolic antennas 1 m (39.37 in) or less in diameter or across and their associated coaxial cabling "are better suited" to Article 840 is an unsubstantiated technical change.

25 Ivans, R. This proposal should be Accepted In Part. Including flat antennas and correcting the term dish to parabolic should be accepted. However, there is no technical substantiation provided why parabolic antennas 1 m or less in diameter should be excluded from Article 810 or why these should be treated differently than parabolic antennas greater than 1 m in diameter. They are all subject to lightning transients. In addition, although Article 840 covers premises powered broadband systems that deliver broadband services that an antenna might provide, the requirements were specifically developed to cover only fiber to the premises systems where there is no metallic wiring or cable members conductively connected to cabling or devices outside of the building. In order for small parabolic antennas to be included in article 840, appropriate requirements would need to be developed to cover outside cabling and antennas that may be subject to lightning transients. Finally, installation criteria and requirements would need to be developed that somehow differentiate these small parabolic antennas from other antenna systems still covered under Article 810. Johnson, S. The substantiation does not present a compelling argument for moving 1 meter and smaller diameter parabolic dishes into Article 840, while leaving larger parabolic dishes in Article 810. Prezioso, L. The proposal justification and explanation did not provide sufficient substantiation regarding why the term "dish" should be replace with a reference to a "parabolic" antenna exceeding one meter in diameter. 16-142 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 810.2 (Log # 206 ) 16-143 Eligible To Vote:16 Affirmative: 11 : 4 Abstain: 0 : 1 810.3 (Log # 2951 ) Brunssen, J. The "Regulations Governing Committee Projects" state in Section 4-3.3 (d) that proposals shall include a 'statement of the problem and substantiation for Proposal'. The submitter has identified neither a problem nor substantiated excluding flat or parabolic (dish) antennas of less than 1 meter in diameter (or across) from article 810. Stating that flat or parabolic antennas 1 m (39.37 in) or less in diameter or across and their associated coaxial cabling "are better suited" to Article 840 is an unsubstantiated technical change. See my comment supporting my negative ballot on Proposal 16-141. Dorna, G. See my Explanation of Vote on Proposal 16-260. Ivans, R. This proposal should be Rejected. There is no technical substantiation provided why parabolic antennas 1 m or less in diameter should be excluded from the requirements in Article 810 or why these should be treated differently than parabolic antennas greater than 1 m in diameter. They are all subject to lightning transients. It is not appropriate for any antennas to be installed in accordance with article 820 as a blanket requirement. For example, 820.93 (C) describes the use of a listed primary protector. This type of protector is not appropriate for antenna systems which, when protectors are used, would require an antenna lead-in protector specifically designed for antenna systems with surge current ratings. In addition, although Article 840 covers premises powered broadband systems that deliver broadband services that an antenna might provide, the requirements were specifically developed to cover only fiber to the premises systems where there is no metallic wiring or cable members conductively connected to cabling or devices outside of the building. In order for small parabolic antennas to be included in article 840, appropriate requirements would need to be developed to cover outside cabling and antennas that may be subject to lightning transients. Finally, installation criteria and requirements would need to be developed that somehow differentiate these small parabolic antennas from other antenna systems still covered under Article 810. Prezioso, L. Article 840, Network Powered Devices, was written to cover networking devices, not parabolic antennas under one meter in diameter. The proposal justification and explanation did not provide sufficient substantiation regarding why this article should cover parabolic antennas at all, much less only parabolic antennas under one meter in diameter. 16-144 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 810.6 (New) (Log # 1884 )

26 16-145 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 810.7 (New) (Log # 1885 ) 16-146 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 810.11 (Log # 2952 ) 16-147 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 810.16(B) (Log # 2953 ) 16-148 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 810.21 (Log # 634 ) 16-149 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 810.21(C) (Log # 635 ) 16-150 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 810.21(C) Exception (Log # 636 ) 16-151 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 810.21(D) (Log # 637 )

27 16-152 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 810.21(F)(3) (Log # 638 ) 16-153 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 810.71(A) (Log # 639 ) 16-154 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820, Informational Note (Log # 640 ) 16-155 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.2 (Log # 211 ) 16-156 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.2.Abandoned Coaxial Cable, Informational Note (Log # 208 ) 16-157 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.2.Coaxial Cable (Log # 207 ) 16-158 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.2.Exposed (to Accidental Contact), Informational Note (Log # 209 ) 16-159 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.2.Point of Entrance (Log # 210 )

28 16-160 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.2.Point of Entrance (Log # 641 ) 16-161 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.3(B) and 820.3(C) (New) (Log # 447 ) 16-162 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.3(B) (Log # 448 ) 16-163 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.3(H) (Log # 726 ) 16-164 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.3(H) (Log # 2779 ) 16-165 Eligible To Vote:16 Affirmative: 9 : 6 Abstain: 0 : 1 820.24 (Log # 1574 ) Brunssen, J. The "Regulations Governing Committee Projects" state in Section 4-3.3 (d) that proposals shall include a 'statement of the problem and substantiation for Proposal'. The submitter has identified neither a fire nor an electrical safety hazard to warrant expanding the requirements of 820.24. The requirements of 300.4 are intended to promote fire and electrical safety where electrical cables containing significant voltage and available current are run within walls, floors and ceilings. Hazards may result when nails, screws or other fasteners are driven into the wall, floor or ceiling should they puncture the electrical cable. Coaxial cables are much smaller (approximately 1/4 inch in diameter) than power cables, contain no power, and do not pose a fire or electrical safety hazard. Support of cables is presently addressed in 300.4(D). Deike, Jr., R. Coaxial cable should not be held to the same installation requirements as electrical cable. There was no substantiation provided to document that coaxial cable present the same level of hazard to personnel or property that electrical cable does. The level of protection required for coaxial cable should be determined by the end user. Dorna, G. See my Explanation of Vote on Proposal 16-99.

29 Ivans, R. This proposal should be Rejected. Optical fiber and communications circuits are not required to be protected the same as power, Class 1, or life safety circuits, therefore adding all the subsections in 300.4 is unnecessary. Section 90.1(A) states the purpose of the NEC is practical safe guarding of persons and property from hazards arising from the use of electricity. The requirements of 300.4 are intended to protect cables containing voltage and available current that present the risk of fire or electrical shock. Where there is only signal power, limited power or no power at all (optical fiber) in the cable, there is no reason to add excessive requirements. Johnson, S. The workmanship requirements for low voltage coaxial cables are not the same as those required for high voltage conductors. The safety and shock hazards present in power carrying cables are not present in these types of cables. The submitter's substantiation has not shown that adding these more stringent requirements are necessary from a safety standpoint. Prezioso, L. The proposal failed to present sufficient substantiation for the added requirements and any fire or electrical safety issues that would be remedied by the change. 16-166 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.24 (Log # 2947 ) Affirmative with Comment Ivans, R. I agree with panel action to Accept In Part with further substantiation. It is appropriate to align with NFPA 90A. Cable ties are listed under the UL certification category for Positioning Devices (ZODZ) for this purpose. 16-167 Eligible To Vote:16 Affirmative: 9 : 6 Abstain: 0 : 1 820.24 (Log # 3137 ) Brunssen, J. The "Regulations Governing Committee Projects" state in Section 4-3.3 (d) that proposals shall include a 'statement of the problem and substantiation for Proposal'. The submitter has identified neither a fire nor an electrical safety hazard to warrant expanding the requirements of 820.24. The requirements of 300.4 are intended to promote fire and electrical safety where electrical cables containing significant voltage and available current are run within walls, floors and ceilings. Hazards may result when nails, screws or other fasteners are driven into the wall, floor or ceiling should they puncture the electrical cable. Coaxial cables are much smaller (approximately 1/4 inch in diameter) than power cables, contain no power, and do not pose a fire or electrical safety hazard. Support of cables is presently addressed in 300.4(D). Deike, Jr., R. Coaxial cable should not be held to the same installation requirements as electrical cable. There was no substantiation provided to document that coaxial cable present the same level of hazard to personnel or property that electrical cable does. The level of protection required for coaxial cable should be determined by the end user. Dorna, G. See my Explanation of Vote on Proposal 16-99. Ivans, R. This proposal should be Rejected. Optical fiber and communications circuits are not required to be protected the same as power, Class 1, or life safety circuits, therefore adding all the subsections in 300.4 is unnecessary. Section 90.1(A) states the purpose of the NEC is practical safe guarding of persons and property from hazards arising from the use of electricity. The requirements of 300.4 are intended to protect cables containing voltage and available current that present the risk of fire or electrical shock. Where there is only signal power, limited power or no power at all (optical fiber) in the cable, there is no reason to add excessive requirements. Johnson, S. See my Explanation of Vote on Proposal 16-165. Prezioso, L. See my Explanation of on Proposal 16-165 (Log #1574). 16-168 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.24, Informational Note 2 (Log # 449 )

30 16-169 Eligible To Vote:16 Affirmative: 14 : 1 Abstain: 0 : 1 820.26 (Log # 450 ) Ohde, H. We disagree with the panel action but think that all electrical installations in these areas need to be fire stopped to prevent the possible spread of fire or products of combustion. This requirement should not be just be limited to coaxial cables but should include all electrical installations and equipment such as all raceways, etc. Even though this proposal deals with 820.26, the 2011 NEC 830.26 should also include similar language so there can be consistency with the electrical installation of all electrical equipment where there might be a possibility of spread of fire. 16-170 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.44(D) (Log # 360 ) 16-171 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.47(A) (Log # 451 ) 16-172 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.47(B) Exception No. 2 (Log # 1751 ) 16-173 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.47(B) Exception No. 2 and 820.133(A)(2) Exception No. 1 (Log # 1907 ) 16-174 Eligible To Vote:16 Affirmative: 15 : 0 Abstain: 0 : 1 820.47(B) Exception No. 2 and 820.133(A)(2) Exception No. 1 (Log # 2880 )