Analysis of Large Amplitude Vibration Mechanism of High-speed Train PRC Girder Bridges Based on Vibration Measurement

Similar documents
Clarification of the Effect of High-Speed Train Induced Vibrations on a Railway Steel Box Girder Bridge Using Laser Doppler Vibrometer

EXPERIMENTAL MODAL AND AERODYNAMIC ANALYSIS OF A LARGE SPAN CABLE-STAYED BRIDGE

DYNAMIC CHARACTERISTICS OF A BRIDGE ESTIMATED WITH NEW BOLT-TYPE SENSOR, AMBIENT VIBRATION MEASUREMENTS AND FINITE ELEMENT ANALYSIS

Fumiaki UEHAN, Dr.. Eng. Senior Researcher, Structural Mechanics Laboratory, Railway Dynamics Div.

Comparison of natural frequencies of vibration for a bridge obtained from measurements with new sensor systeme

732. Numerical and experimental identification of vibration convection chamber of fluid power boiler

Effects of Temperature Variation on Cable Forces of an Extradosed Bridge

A detailed experimental modal analysis of a clamped circular plate

Preliminary study of the vibration displacement measurement by using strain gauge

MODAL IDENTIFICATION OF BILL EMERSON BRIDGE

Evaluation of service life of jointed rails

Experimental investigation of crack in aluminum cantilever beam using vibration monitoring technique

Evaluation Methodology on Vibration Serviceability of Bridge by using Non-Contact Vibration Measurement Method

A Novel Crack Location Method Based on the Reflection Coefficients of Guided Waves

Finite Element Modeling of Early Stage Self-loosening of Bolted Joints Haoliang Xu 1, a, Lihua Yang 1, b,, Lie Yu 1,2, c

Effect of temperature on modal characteristics of steel-concrete composite bridges: Field testing

Fundamental Study on the Remote Vibration Measuring System for Evaluating Rock Slope Stability

Module 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry

Very High Frequency Calibration of Laser Vibrometer up to 350 khz

Experimental Investigation of Crack Detection in Cantilever Beam Using Natural Frequency as Basic Criterion

Bridge Vibrations Excited Through Vibro-Compaction of Bituminous Deck Pavement

FLUTTER CONTROL OF WIND TUNNEL MODEL USING A SINGLE ELEMENT OF PIEZO-CERAMIC ACTUATOR

Coda Wave Interferometry used to detect loads and cracks in a concrete structure under field conditions

A novel procedure for evaluating the rotational stiffness of traditional timber joints in Taiwan

CASE STUDY BRIDGE DYNAMIC MONITORING

CALIBRATION OF LASER VIBROMETER STANDARDS ACCORDING TO ISO

Modal Parameter Identification of A Continuous Beam Bridge by Using Grouped Response Measurements

Implementation and Validation of Frequency Response Function in LS-DYNA

LONG-TERM MONITORING OF SEOHAE CABLE-STAYED BRIDGE USING GNSS AND SHMS

Mode-based Frequency Response Function and Steady State Dynamics in LS-DYNA

Correction for Synchronization Errors in Dynamic Measurements

Displacement Measurement of Burr Arch-Truss Under Dynamic Loading Based on Image Processing Technology

Response spectrum Time history Power Spectral Density, PSD

EWGAE 2010 Vienna, 8th to 10th September

Genetic Algorithms-Based Parameter Optimization of a Non-Destructive Damage Detection Method

저비용음압센서를이용한콘크리트구조물에서의비접촉 Impact-Echo 기반손상탐지

Effect of Braces on Framed Machine Foundation for Turbo Generator

MONITORING OF DYNAMIC PARAMETERS OF STEEL BRIDGES BY VIBRATION TESTS 1 INTRODUCTION

Impact sound insulation: Transient power input from the rubber ball on locally reacting mass-spring systems

Non-contact structural vibration monitoring under varying environmental conditions

An experimental investigation of vibration characteristics in the diamond wire sawing of granite

Identification of Delamination Damages in Concrete Structures Using Impact Response of Delaminated Concrete Section

Development of Shock Acceleration Calibration Machine in NMIJ

IOMAC' May Guimarães - Portugal

Application of MEMS accelerometers for modal analysis

Digital inertial algorithm for recording track geometry on commercial shinkansen trains

3.0 Apparatus. 3.1 Excitation System

Characterization of Train-Track Interactions based on Axle Box Acceleration Measurements for Normal Track and Turnout Passages

430. The Research System for Vibration Analysis in Domestic Installation Pipes

TRANSVERSE FATIGUE CHARACTERISTICS OF BOLTED JOINTS TIGHTENED THIN PLATES

Experimental Study of Infrastructure Radar Modulation for. Vehicle and Pedestrian Detection

VIBROACOUSTIC MEASURMENT FOR BEARING FAULT DETECTION ON HIGH SPEED TRAINS

Finite element simulation of photoacoustic fiber optic sensors for surface rust detection on a steel rod

Vibration Fundamentals Training System

Countermeasure for Reducing Micro-pressure Wave Emitted from Railway Tunnel by Installing Hood at the Exit of Tunnel

SOLVING VIBRATIONAL RESONANCE ON A LARGE SLENDER BOAT USING A TUNED MASS DAMPER. A.W. Vredeveldt, TNO, The Netherlands

New Long Stroke Vibration Shaker Design using Linear Motor Technology

An Investigation of Optimal Pitch Selection to Reduce Self-Loosening of Threaded Fastener under Transverse Loading

Modeling of the part-pedaling effect in the piano

TESTING A BINARY CRACK SENSOR USING A LABORATORY MODEL OF CRACKS IN STEEL GIRDERS

AN AUTOMATED DAMAGE DETECTION SYSTEM FOR ARMORED VEHICLE LAUNCHED BRIDGE

FIRST MEASUREMENTS FROM A NEW BROADBAND VIBROTHERMOGRAPHY MEASUREMENT SYSTEM

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor

DEVELOPMENT OF MEASUREMENT SYSTEM USING OPTICAL FIBER AE SENSORS FOR ACTUAL PIPING

Modal Parameter Estimation Using Acoustic Modal Analysis

Nonlinear Ultrasonic Damage Detection for Fatigue Crack Using Subharmonic Component

Control and Signal Processing in a Structural Laboratory

Fatigue crack propagation in uniaxial loading and bending fatigue in 20 khz testing. Mohamed Sadek PhD Student Karlstad university

Experimental study of traffic noise and human response in an urban area: deviations from standard annoyance predictions

sin(wt) y(t) Exciter Vibrating armature ENME599 1

NONDESTRUCTIVE EVALUATION OF CLOSED CRACKS USING AN ULTRASONIC TRANSIT TIMING METHOD J. Takatsubo 1, H. Tsuda 1, B. Wang 1

Pitch Bending PITCH BENDING AND ANOMALOUS BEHAVIOR IN A FREE REED COUPLED TO A PIPE RESONATOR

Experimental Vibration-based Damage Detection in Aluminum Plates and Blocks Using Acoustic Emission Responses

Influence of the Vibrational Properties of the Resonance Board on the Acoustical Quality of a Piano

FREE VIBRATION ANALYSIS AND OPTIMIZATION OF STREEING KNUCKLE

Finite Element Study of Using Concrete Tie Beams to Reduce Differential Settlement Between Footings

EXPERIMENTAL ANALYSIS OF BOLT LOOSENING DYNAMICS CHARACTERISTIC IN A BEAM BY IMPACT TESTING

Keywords: Bracing bracket connection, local deformation, selective pallet racks, shear stiffness, spine bracings.

Periodic Error Correction in Heterodyne Interferometry

IOMAC' May Guimarães - Portugal TIME-FREQUENCY ANALYSIS OF DISPERSIVE PHENOMENA IN BRIDGES

INTERNAL CONCRETE INSPECTION AND EVALUATION METHODS FOR STEEL PLATE-BONDED SLABS BY USING ELASTIC WAVES VIA ANCHOR BOLTS

Generic noise criterion curves for sensitive equipment

Modal Analysis of Microcantilever using Vibration Speaker

Modal vibration control of submarine hulls

TECHNOLOGY UTILIZATION GUIDELINES OF STRUCTURAL HEALTH MONITORING FOR BUILDINGS AND ITS APPLICATION

Acoustic Resonance Analysis Using FEM and Laser Scanning For Defect Characterization in In-Process NDT

MEASUREMENT OF SURFACE DISPLACEMENT EXCITED BY EMAT TRANSDUCER

Development of Variable Rate Spring by Permanent Magnet with Flux Concentration Method

(i) Sine sweep (ii) Sine beat (iii) Time history (iv) Continuous sine

Dynamic Strain Measurement Using Improved Bonding Fiber Bragg Grating

RECENTLY DESIGNED BOW-STRING RAILWAY BRIDGES IN SLOVAKIA

Keywords: piezoelectric, micro gyroscope, reference vibration, finite element

Convenient Structural Modal Analysis Using Noncontact Vision-Based Displacement Sensor

Damage Detection Using Wavelet Transforms for Theme Park Rides

Method of Determining Effect of Heat on Mortar by Using Aerial Ultrasonic Waves with Finite Amplitude

Monitoring The Machine Elements In Lathe Using Vibration Signals

ULTRASOUND IN CFRP DETECTED BY ADVANCED OPTICAL FIBER SENSOR FOR COMPOSITE STRUCTURAL HEALTH MONITORING

Investigation on Sensor Fault Effects of Piezoelectric Transducers on Wave Propagation and Impedance Measurements

2 Study of an embarked vibro-impact system: experimental analysis

EFFECTS OF ACCELEROMETER MOUNTING METHODS ON QUALITY OF MEASURED FRF S

Transcription:

6 th International Conference on Advances in Experimental Structural Engineering th International Workshop on Advanced Smart Materials and Smart Structures Technology August -2, 25, University of Illinois, Urbana-Champaign, United States Analysis of Large Amplitude Vibration Mechanism of High-speed Train PRC Girder Bridges Based on Vibration Measurement Junki Nakasuka, Tsukasa Mizutani 2, Yujin Yamamoto Masato Uchida 4, Di Su 5, Tomonori Nagayama 6 Master Student, Dept. of Civil and Engineering, University of Tokyo, Japan. E-mail: nakasuka@bridge.t.u-tokyo.ac.jp 2 Assistant Professor, Dept. of Civil and Engineering, University of Tokyo, Japan. E-mail: mizutani@bridge.t.u-tokyo.ac.jp Master Student, Dept. of Civil and Engineering, University of Tokyo, Japan E-mail: yamamoto@bridge.t.u-tokyo.ac.jp 4 Research Fellow, East Japan Railway Company, Japan E-mail: masato-uchida@jreast.co.jp 5 Project Lecturer Professor, Dept. of Civil and Engineering, University of Tokyo, Japan. E-mail: su@bridge.t.u-tokyo.ac.jp 6 Associate Professor, Dept. of Civil and Engineering, University of Tokyo, Japan. E-mail: nagayama@bridge.t.u-tokyo.ac.jp ABSTRACT Many of railway infrastructure in Japan for high speed train, so called Shinkansen, are bridges. It is vital to find and cope with the problems of bridges as soon as possible. Recently, the railway company found some Prestressed Reinforced Concrete (PRC) girder bridges had large amplitude vibration which was not observed in properly designed girders. Girders natural frequency estimated by impact test was found to be % larger than the excitation frequency caused by Shinkansen passing in specific velocity. Thus, the large amplitude vibration mechanism cannot be simply explained as resonance. In this paper, we conducted vibration measurement of the large amplitude vibration girders. The result of measured vibration analysis shows the natural frequency becomes lower as amplitude becomes larger, but the natural frequency is still 7 % larger which is too large in terms of analysis error. Then, we took into consideration the effect of Shinkansen vehicles weight and conducted eigenvalue analysis using a FEM model introducing those effect. As a result, the natural frequency during Shinkansen passing in the specific velocity becomes close to the excitation frequency. Resonance phenomena occurs at that moment, which is considered as the large amplitude vibration mechanism. KEYWORDS: Large amplitude vibration, PRC girder, vibration measurement, amplitude dependency of natural frequency, Shinkansen viaduct. INTRODUCTION Shinkansen operation plays a significant role in large transportation of human and goods in Japan. The operation disrtion makes crucial effect on domestic economy. Therefore, structural characteristics of the infrastructure of Shinkansen should be evaluated properly. In Shinkansen 29.2 m span PRC girders, which is allowed for clack to occur only during Shinkansen passing in design [], the large amplitude vibration occurs during Shinkansen passing in specific velocity, which caused the fatigue fracture of a connecter of aerial wiring [2]. In design of only these girders, impact coefficient was not set properly. Thus, such a phenomenon does not occur in other girders. The railway company defines the amplitude of vibration larger than 2 mm between maximum and minimum displacement as large amplitude vibration []. Figure. shows the dynamic response of two girders with same design during Shinkansen passing in the same velocity; one has the large amplitude vibration phenomena (called large amplitude vibration girder ), the other does not have it (called small amplitude vibration girder ). Figure. shows amplitude increases as Shinkansen passes, the girder bends to the per, and the large amplitude vibration continues after Shinkansen passing in the large amplitude vibration girder unlike the small amplitude vibration girder.

displacement[mm] 5 5-5 large amplitude vibration girder small amplitude vibration girder max min -5 2 4 6 time[s] Figure. Small and large amplitude vibration (velocity: 229 km/h) View Table 2. description of measured three girders Girder A Girder B Girder C Amp Large amplitude Large amplitude Small amplitude Measurement date 24/2/ 24//26-27 24/2/ Table 2.2 Measured bridge design Structural type Post-tension Tshape PRC 4 main beam Girder length m Span 29.2 m Rails A,B: 4 m Radius of C: curvature Girder height.7 m Bearing Rubber (fix-roller) The railway company conducted impact test on the large amplitude vibration girders to clarify the mechanism [2]. The natural frequency was estimated to be about. Hz. On the other hand, the excitation frequency by Shinkansen passing under certain velocity causing the large amplitude vibration was estimated to be 2.6 Hz. Large amplitude vibration mechanism was initially thought as resonance, but there is % difference between the natural frequency and the excitation frequency, which is too large to ignore as an analysis error. Therefore, the problem does not considered to be simple resonance, and the mechanism or structural characteristics of the girders should be clarified. Considering the above, the objectives of this paper are as follows. Firstly, vibration measurement on the large amplitude vibration girders in Shinkansen passing under various velocity was conducted and the large amplitude vibration mechanism are clarified by analyzing the measured vibrations and conducting eigenvalue analysis using a FEM frame model. Secondly, by analyzing the large amplitude girders vibration measured by the railway company for years, long term trend of the structural characteristics is clarified. 2. VIBRATION MEASUREMENT OF LARGE AMPLITUDE VIBRATION GIRDERS The railway company conducted single point vibration measurement of the displacement on the large amplitude vibration girders [2]. In this chapter, multi-point vibration measurement of the large amplitude vibration girders was conducted and the structural characteristics of those are clarified by analyzing measured vibrations and identifying the modal shape. A small amplitude vibration girder was also measured to compare the difference of amplitude between the large and small amplitude vibration girders. Responses of the girders under 74 Shinkansen passing in velocity from 9 km/h to 25 km/h were measured for 4 days. 2.. Measured girders Table 2. shows specification of the measured three girders. These girders design are the almost same as shown in Table 2.2, which can avoid difference of the design affecting on amplitude. 2.2. Measuring Instrument To identify the modal shape, two RSV-5 which are laser doppler vibrometer and manufactured by Polytec shown as Figure 2. were used. The laser doppler vibrometer is useful under such a condition in this measurement that it s hard to access the surface or the back of the girder because of high pier height or heavy traffic under the girder.

Sensor head Data Data logger Acquisition (PC) Board (DAQ) Controller Figure 2. RSV-5 used in the vibration measurement R R2 R R4 R5 R6 R7 R8 R9 Q Q5 Q7 P P2 P P4 P5 P6 P7 P8 P9 Figure 2.2 Measured points (Reference point: R5 (girder A and B), P5 (girder C)) Girder A Girder B Girder C time[s] Velocity 2 km/h 2 km/h 22 km/h 2 km/h 24 km/h 25 km/h Excitation 2.2 Hz 2. Hz 2.4 Hz 2.6 Hz 2.7 Hz Hz frequency Figure. Displacement in each girder under typical Shinkansen velocity (Sampling frequency: 5 Hz) 2.. Measurement way Disp[mm] Figure 2.2 shows measured points.r5 in girder A and B, P5 in girder C were selected as reference point. One RSV-5 always measured vibration on the reference point in any Shinkansen passing. The other RSV-5 measured vibration on a point except for the reference point, called moving measured point, which was moved after every Shinkansen passing. Vibrations of the fixed reference point and the moving measured point were measured simultaneously.. VIBRATIONS ON REFERENCE POINT In this chapter, the structural characteristics of the large amplitude vibration girders and the mechanism is examined by analyzing the vibrations on the reference point. Figure. shows the vibrations on the reference point under typical Shinkansen s velocity/excitation frequency. In girder C the amplitude seems stable regardless of Shinkansen s velocity. On the other hand, in girder A and B amplitude becomes larger when the Shinkansen s velocity becomess closer to about 2 km/h, about 2.6 Hz in excitation frequency. This result does not conflict with the railway company s impact test.

Fourier amplitude spectrum[mm].5.4..2. 2.9. frequency[hz] (a) girder A Fourier amplitude spectrum[mm].5 2.7 2.9 frequency[hz] (b) girder B Figure.2 Fourier amplitude spectrum in each girder s free vibrations.2 2.6 R=-.89 R 2 =-.88998 amplitude[mm] (a) girder A.2 2.6 R=-.76 amplitude[mm] (b) girder B Figure. relationship between logarithm of amplitude and natural frequency (red line: linear regression line).. Examining structural characteristics and mechanism of large amplitude vibration by estimating natural frequency The vibration after Shinkansen passing seems free vibration as shown in Figure., which means natural frequency can be easily estimated. Whether the large amplitude vibration mechanism is resonance or not can be quantitatively evaluated by comparing the natural frequency estimated from the free vibration with the excitation frequency of 2.6 Hz causing the large amplitude vibration. The natural frequency was estimated by discrete Fourier transform. In this analysis, we extracted such free vibration that the length is 2 second and first wavelength is cut to avoid Shinkansen passing affecting on the free vibration. Figure.2 shows Fourier amplitude spectrum of the measured free vibrations of the large amplitude vibration girders. According to the Figure.2, the dominant frequency monotonically increases as Fourier amplitude spectrum decreases, which means the natural frequency can increases in free vibration as amplitude decreases in free vibration. Figure. shows the relationship between each cycle s amplitude and the reciprocal of each cycle s wavelength which is regarded as instantaneous natural frequency. In this analysis, the free vibrations were processed by a low pass filter with 4 Hz cut off frequency to remove high frequency noise. According to Figure., the large amplitude vibration girders clearly have amplitude dependence of natural frequency. Linear regression analysis shows the logarithm of amplitude and natural frequency have strong correlation as shown in Figure.. The linear regression lines were calculated as Eq.. and Eq..2 in girder A and B, respectively, which enables to estimate natural frequency from amplitude. Girder A: f n =-.582 log σ +2.9 (.) Girder B: f n =-.476 log σ +6 (.2) f n is natural frequency (Hz), σ is amplitude (mm). According to Eq.. and Eq..2, the natural frequency decreases to about 2.75 Hz to Hz at the amplitude of 5 mm which is the measured maximum displacement, but still there is about 7% difference from the excitation frequency of 2.6 Hz causing the large amplitude vibration. Therefore, the large amplitude vibration mechanism cannot explained only as the amplitude dependency of natural frequency.

. m 2 m. m.8 m.65 m S D D2 D D4 S2 E E2 E E4 E5 E6 E7 E8 E9 Transverse beams Slab Main beams Slab Figure 4. FEM frame model (same in girder A and B) Table 4. the second moment of area of each component beam the second moment of area (m 4 ) S.4 - S2.69 - D~D4.78~.95 E, E9.45 E2,E4,E6,E8 6.8 - E, E7.9 E5 A:.68/ B:.82 Young s modulus (N/m 2 ) Table 4.2 material characteristics of each component Main beam Transverse beam slab Concrete. PC tendon 2. Reinforcing rebar 2. ---- Unit weight (kg/m ) 25 Poisson s ratio.2.2. Evaluating mechanism of amplitude dependency of natural frequency The amplitude dependency of natural frequency can be caused by crack. As we refers in chapter, in PRC girders design, crack is allowed to occur in the large amplitude vibration girders only during Shinkansen passing. If girders vibrate in large amplitude, the crack can open and then effective sectional area decreases, which leads stiffness decreasing. If stiffness decreases, natural frequency can also decrease. On the other hand, if girders vibrate in small amplitude, the crack may not open and effective sectional area increases, stiffness can increases, and natural frequency can increases. According to the Figure.2, the natural frequency converges to. Hz and 2.95 Hz in girder A and B, respectively. This result does not conflict with railway company s impact test. This is because natural frequency is estimated by vibration with sufficiently small amplitude in impact test. 4. EIGENVALUE ANALYSIS USING FEM FRAME MODEL In the last chapter, we found natural frequency could decrease as amplitude increases, but the natural frequency decreases to 2.75 Hz~ Hz at the smallest, which is still significantly larger than excitation frequency of 2.6 Hz causing the large amplitude vibration. On the other hand, Shinkansen s vehicle weight can also decreases the natural frequency. To estimate the natural frequency considering Shinkansen s vehicle weight as well as amplitude dependency of natural frequency, FEM frame model was made and eigenvalue analysis was conducted. 4.. FEM frame model The structure of the FEM frame model, the second moment of area and material characteristics are shown in Figure 4., Table 4. and Table 4.2, respectively. These are referred by Tetsudou Kouzoubutsutou Sekkei Hyoujun Dou Kaisetu [4]. Now, in the main beams the second moment of area changes depending on the location of the sections because PC tendon is located different place in each section. Furthermore, E5 component in girder B is bigger than that in girder A, which is introduced only in girder B. 4.2. Modal shape identification Using the measured data, modal shape was identified to calibrate the FEM frame model. The identification procedure of the modal shape is as follows.

Identified modal shape (measured data) Analyzed modal shape (after calibration) Analyzed modal shape (before calibration) girder A girder B.2.4.6.8 natural frequency:. Hz -to- girder ratio:.92.2.4.6.8 natural frequency: 2.95 Hz -to- girder ratio:.86.2.4.6.8 natural frequency:. Hz -to- girder ratio:.92.2.4.6.8 natural frequency: 2.95 Hz -to- girder ratio:.98.2.4.6.8 natural frequency:.22 Hz -to- girder ratio:.99.2.4.6.8 natural frequency:.7 Hz -to- girder ratio:.98 Figure 4.2 Identified modal shape and analyzing modal shape before/after calibration Firstly, two free vibrations on the reference point and every moving measured point were extracted. Secondly, by conducting discrete Fourier transform to the free vibrations, the ratio of amplitude on the reference point and that on another moving measured point at the natural frequency were calculated. Finally, by normalizing amplitude at the reference point, modal shape could be estimated. In this paper, primary bending mode was distinguished and could be easily identified. 4.. Calibration of FEM frame model based on identified modal shape In calibration of the FEM frame model by using the identified modal shape, we focused on the natural frequency and the -to- girder ratio. As Figure 4.2 shows, analyzed modal shape before calibration has higher natural frequency and smaller -to- girder ratio than identified modal shape. The shape of the primary bending mode strongly depends on the stiffness of four main beams, therefore we changed them by trial and error as the natural frequency and the -to- girder ratio had good agreement with identified them. As for the model of girder A, by decreasing the stiffness of D and D4 by 28%, they had good agreement with the identified them. As for the model of girder B, it was hard to make -to- girder ratio of the model have good agreement with the identified one. Thus, by decreasing the stiffness of all main beams to 5%, only natural frequency had good agreement with the identified one. 4.4. Estimating natural frequency under existence of Shinkansen s vehicle weight By introducing the Shinkansen s vehicle weight and the amplitude dependency of natural frequency to the model, how much the natural frequency decreases is clarified in this chapter. In reality, the large amplitude vibration phenomena occurs only when Shinkansen passes on the -side, therefore Shinkansen s vehicle weight is introduced on the -side. Shinkansen s vehicle weight should be introduced as distributed load. Then, concentrated loads calculated by a weighted average considering the location of the rails and the main beams were introduced at the each lattice point. As for amplitude dependency of natural frequency, stiffness lowering rate in each main beam depending on displacement during Shinkansen passing was introduced as follows. Firstly, we estimated displacement d (mm) in each main beam. As Figure 4. shows, the displacements in each main beam are not constant in assuming Shinkansen passes on the -side. The displacement of the outmost beam of the line (d ) when Shinkansen passes on the -side (Figure 4.(a)) is considered to be equal to that of the outmost beam of the -side when Shinkansen passes on the -side (Figure 4.(b)) because the girder s shape is almost symmetry. The latter displacement can be easily estimated from the vibration data on the reference point locating at center of the outmost main beam of the -side. The displacement of the out most beam of the -side (d 4 ) when Shinkansen passes on the -side can be directly estimated from the vibration data on the reference point. The displacement of middle two main beams (d 2, d ) are calculated as a slope of the displacement was linear.

d d d d 4 2 d d 2 d d 4 Reference point (a) Shinkansen passing on the -side (b) Shinkansen passing on the -side Figure 4. Assumption of displacement of main beams Secondly, we estimated the extent of the stiffness decreasing in each main beam. Assuming main beams held Eq.. and Eq..2, natural frequency can be calculated from the estimated displacement in each main beam. Furthermore, stiffness is proportional to the square of natural frequency from general beam theory [5]. Therefore, stiffness lowering rate β was calculated by Eq. 4.. (4.) f n is the estimated natural frequency (Hz), and f is the natural frequency in sufficiently small amplitude (Hz). As mentioned in chapter, f =.(Hz) and f =2.95(Hz) in girder A and girder B, respectively. By conducting eigenvalue analysis using the FEM frame model which was calibrated based on the measured data and introduced Shinkansen s vehicle weight and the amplitude dependency of natural frequency, the natural frequency decreases to 2.6~2.62 Hz in girder A, and 2.58~2.6 Hz in girder B, which are almost same as the excitation frequency of 2.6 Hz causing the large amplitude vibration. In short, the large amplitude vibration mechanism is concluded as instantaneous resonance during Shinkansen passing. 5. LONG TERM TREND OF STRUCTURAL CHARACTERISTICS Until the last chapter, the large amplitude vibration mechanism is clarified. In this chapter, the long term trend of the structural characteristic of amplitude dependency of natural frequency is also estimated by analyzing the vibration data measured by railway company for past years for future prediction of the structural characteristics. Figure 5. shows the amplitude dependency of natural frequency in every 2 months analyzed in the same way as Figure.. This figure indicates there is some seasonal dependency of natural frequency, especially in winter natural frequency increases and in summer decreases. Then, we extracted the amplitude at the same level to avoid the effect of the amplitude dependency. Figure 5.2 shows the average natural frequency in the each amplitude in the measurement date, which actually indicates the natural frequency decreases in summer and increases in winter. Furthermore, Figure 5.2 also indicates that average temperature of the measurement date and the natural frequency have strong negative correlation, R=-.9 and R=-.7 in girder A and girder B, respectively. Comparing natural frequency in amplitude of.5~2.5 mm in winter with that in amplitude of 5.5~6.5 mm in summer, the difference is about.2 Hz which cannot be ignorable. This result tells us that environmental condition is also important to comprehend the structural characteristics. 6. SUMMARY Some Shinakansen PRC viaducts were found to have the large amplitude vibration phenomena which can affect Shinkansen operation and structure itself. According to the multi-point vibration measurement conducted by us, the large amplitude vibration phenomena occurs under Shinkansen s velocity of 2 km/h, the excitation frequency of 2.6 Hz, which does not conflict with the investigation preliminarily conducted by the railway company. Furthermore, we observed the natural frequency of the large amplitude vibration girders decrease by.2 Hz at most in large amplitude which shows the girder has nonlinear dynamic property. This reason is considered to be a crack allowed to occur in design in the PRC structure in large amplitude. However, the large amplitude vibration mechanism cannot be explained only as the nonlinearity of the natural frequency because there is still non-

. 2.9 2.7 22/~2 2/~4 2/5~6 2/7~8 2/9~ 2/~2 24/~2 24/~4. 2.9 2.7 2/7~8 22/9~ 22/~2 2/~2 2/~4 2/5~6 2/7~8 2/9~ 24/~2 2.6 amplitude[mm] (a) girder A 2.6 amplitude[mm] (b) gider B Figure 5. The season change of the natural frequency 2.9.5~2.5mm 2.5~.5mm.5~4.5mm 4.5~5.5mm 5.5~6.5mm average temperature 5 25 5 5 temperature[ ] 2.9 average temperature 5 25 5 5 temperature[ ] 2.7-5 2// /5/ // 4/5/ date (a) girder A 2.7-5 /5/ 2/5/ /5/ 4/5/ date (b) girder B Figure 5.2 natural frequency in each amplitude level in each measurement date ignorable difference between the natural frequency and the excitation frequency causing the large amplitude vibration phenomena. To consider not only the amplitude dependency of natural frequency but also Shinkansen s vehicle weight, the FEM frame model was developed. By conducting eigenvalue analysis using the calibrated model introduced Shinkansen s vehicle weight and amplitude dependency of natural frequency, the natural frequency can decreases to the excitation frequency causing large amplitude vibration phenomena during Shinkansen passing, which is considered to be the large amplitude vibration mechanism. Furthermore, this paper looked into the long term trend of the structural characteristics as well, and found the natural frequency varies depending on the season clearly. This result implies that to comprehend the structural characteristics of the large amplitude vibration girders, the environmental condition of the measurement is also important. REFERENCES. Railway Technical Research Institute. (987). PRC Keta Sekkei Shishin (Guideline of Construction of PRC girder), Railway Technical Research Institute. [Published in Japanese] 2. Yukito Fujie, Sigenobu Iguchi, Yoshinori Matsuda, and Kaoru Kobayashi. (28). Houkoku Shinkansen Soukou ni Tomonau PRC Tanjunketa no Shindou ni Tsuite (Vibration of PRC Simple Girder Associated with Shinkansen Passing). Proceedings of the Japan Concrete Institute. :, 886. [Published in Japanese].. JR East Consultants Company. (24). Hokuriku Shinkansen Keta Sindou Chousa Sagyou Houkokusyo (Report of Vibration Measurement of Hokuriku Shinkansen girders). 25:9. I-4. [Published in Japanese]. 4. Railway Technical Research Institute. (992). Tetsudou Kouzoubutsutou Sekkei Hyoujun Dou Kaisetu (Normality and Commentary of Construction of Railway Infrastructures), Maruzen Inc. [Published in Japanese]. 5. Yoshihiko Hagiwara, Akihiro Misawa, Hideto Suzuki. (996). Yokuwakaru Zairyourikigaku (Understandable Material Dynamics), Ohm Publication Office. [Published in Japanese].