... avoid using constructionstyle generators that have master GFCIs.

Similar documents
Production power on a budget: How to generate clean reliable power, Part 2 By Guy Holt

Production power on a budget: How to generate clean reliable power, Part 1 By Guy Holt

G.F.C.I. by Sam Goldwasser -- exerpts from: Sci.Electronics.Repair FAQ:

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

Preface...x Chapter 1 Electrical Fundamentals

User's Guide. AC Circuit Load Tester. Model CT70

A DUMMIES GUIDE TO GROUND FAULT PROTECTION

TN, TT & IT Earthing Arrangements

Grounding for Power Quality

Busbars and lines are important elements

Alternating Current Power

TEACHER ASSESSMENT BLUEPRINT ELECTRICAL CONSTRUCTION TECHNOLOGY. Test Code: 5171 Version: 01

GROUNDED ELECTRICAL POWER DISTRIBUTION. Excerpt from Inverter Charger Series Manual BY: VIJAY SHARMA ENGINEER

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

LCM100 USER GUIDE. Line Carrier Modem INDUSTRIAL DATA COMMUNICATIONS

ET 40 - Electrician Theory Examination Marking Schedule

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL series

Circuit Analyzer MS5908A. Operation S Manual MS5908A TEST. ma VA ms Hz% 12 A 15 A 20 A HOLD ms VA. V Vd Z RCD GFCI

MINING EARTH LEAKAGE PROTECTION WITH VARIABLE SPEED DRIVES

Application Note (Revision NEW) Original Instructions. EMI Control in Electronic Governing Systems

MASTECH MS5908. Circuit Analyzer

Earth leakage protection Response time of medium-sensitivity residual current devices

To Float or Not to Float? Analysis of a floating vs. grounded output Associated Power Technologies

IMPORTANCE OF INSULATION RESISTANCE

Grounding Recommendations for On Site Power Systems

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

Section 6: System Grounding Bill Brown, P.E., Square D Engineering Services

Partial Discharge, Survey or Monitor?

Single Earthed Neutral and Multi Earthed Neutral. Single Earthed Neutral and Multi Earthed Neutral: Multi Grounded Neutral System (MEN):

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Residual Current Operated Circuit-Breakers (RCCBs)

Page 1 T O O L S A N D M AT E R I A L S R E Q U I R E D. 1. Screwdriver 2. Carpenter's level 3. Electrical Tape PA R T S L I S T. A.

Electrical Protection System Design and Operation

ET 51 - Electrician Theory Examination Marking Schedule

CHAPTER 2 ELECTRICAL POWER SYSTEM OVERCURRENTS

Healthcare Isolation Power Systems. Presented by: David Knecht

EELE 354 Lab Assignment 5: Fuse and Ground Fault Current Interrupter (GFCI) Operation

Selective Coordination for Emergency and Legally-Required Standby Power Distribution Systems

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

Transformer Core for Ground Fault Circuit Interrupter (GFCI) (ELCB Earth leakage circuit breaker)

Industrial and Commercial Power Systems Topic 7 EARTHING

Product Classroom. Introduction. Grounding Systems. TN system. Title. Grounding System Introduction. Date October, 2016.

Instruction Manual. Description Calibration. Excitation Sensor and Reverse Power Relay

Class 300 Equipment CBS 305, 320 Current Boost Systems FEATURES. DESCRIPTION Page 2. SPECIFICATIONS Pages 2 through 4.

Back to the Basics Current Transformer (CT) Testing

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Chapter 1 Electrical Theory and Part C Series Parallel and Code Questions Multiwire Branch Circuits Unit 1 Electrician s Math

Instruction Manual for Digital Grounding Resistance Meter

Grounding and Bonding

The InterNational Electrical Testing Association Journal. BY STEVE TURNER, Beckwith Electric Company, Inc.

SE-502 MANUAL GROUND-FAULT GROUND-CONTINUITY DETECTOR

Device Interconnection

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

ELECTRICIAN S THEORY EXAMINATION 17 November 2012 QUESTION AND ANSWER BOOKLET

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

FINAL - ET 60 - Electrician Theory Examination Marking Schedule

Variable Transformers Product Design & Engineering Data

2 Grounding of power supply system neutral

Chapter 2: Electricity

Maintenance/Connection/Installation Service life C/O cyclesx1000

Ground Fault Protection

ECE 528 Understanding Power Quality

AC Voltage- Pipeline Safety and Corrosion MEA 2015

PCR Polarization Cell Replacement. The Polarization Cell Replacement (PCR) Technical Literature COMMON APPLICATIONS

ABSTRACT 1 INTRODUCTION

ECM3 EARTH CONTINUITY RELAY

Quality Control Checklist - Design Drawings

1 INTRODUCTION 1.1 PRODUCT DESCRIPTION

MV network design & devices selection EXERCISE BOOK

Protective Relays Digitrip 3000

Application Note. About VFD Cables Steve Wetzel, Sr. Product Engineer

Short-Circuit Current Calculations

I. Introduction to Animal Sensitivity and Response

Webinar: An Effective Arc Flash Safety Program

Residual current circuit breakers (RCCBs)

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

EPG. by Chris C. Kleronomos

Functional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit.

This article is designed to give you an insight into generators that can be used with your caravan or motorhome.

The Variable Threshold Neutral Isolator (VTNI)

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

Instruction Manual. Manual de instrucciones. Guide d utilisation ET PMET Rev 808

Understanding Harmonics

Ground Fault Protection

INTELLIMETER REGISTER

SureTest Circuit Analyzers

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

ELECTRICIAN S THEORY EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Current Transformer Requirements for VA TECH Reyrolle ACP Relays. PREPARED BY:- A Allen... APPROVED :- B Watson...

Custom VIBRASONIC s Manual P/N

Grounding System Theory and Practice

Exploring the Necessity of the Hot Hipot Test

SAFETY ASPECTS AND NOVEL TECHNICAL SOLUTIONS FOR EARTH FAULT MANAGEMENT IN MV ELECTRICITY DISTRIBUTION NETWORKS

Unit 6 ~ Learning Guide Name:

3Ø Short-Circuit Calculations

Choice of earth leakage protection devices

Power System Protection Manual

Transcription:

Production Power on a budget: Ground-fault protection strategies, Part 3 BY GUY HOLT The third in a multipart exploration of how to safely use small portable generators in motion picture and live event production. IN ORDER FOR GROUND FAULT CIRCUIT INTERRUPTERS (GFCI) to save lives, they have to be used. Given production schedules these days, if a GFCI repeatedly nuisance trips it will be quickly pulled out of service. This makes mitigating the effects of residual currents and small ground leaks an important part of ground-fault protection, so that, should an individual take a shock, there is an operational GFCI in place that will cut power within the necessary microseconds. Here s how to accomplish this with small portable generators. As we learned in Part 2 of this series, residual currents generated by multiple devices on top of minor ground-faults in a distribution can easily approach, and possibly even exceed the 4 6 ma trip threshold of Class A GFCI devices. To make matters worse, the hardware store type of GFCI used on portable generators are particularly prone to tripping under these circumstances, because of their quick response time and the fact that they do not incorporate high frequency filtration to eliminate nuisance tripping from high frequency residual currents. To compound the problem even further, many portable generators incorporate a single master GFCI that protects multiple circuits and hence is subjected to the accumulation of residual currents of multiple loads. The problem to using this approach to ground-fault protection (commonly called a blanket approach) is that the accumulation of all these small leakages will be enough to either trip a master GFCI outright or use up so much of the GFCI s allowed leakage current that it becomes excessively sensitive to momentary transient leakage currents caused by the switching on and off of electronic devices as discussed in Part 2.... avoid using constructionstyle generators that have master GFCIs. Figure 1 A blanket strategy to ground-fault protection. A GFCI tripping under these circumstances is simply a nuisance because it is unnecessary from a safety standpoint. Confined to the equipment-grounding conductor (EGC), residual currents present no danger. The human body is a resistive load and according to Ohm s Law (V = I R) shock current (I) is a function of voltage (V) and resistance (R) only. It is not the residual current that causes a 24

shock, but the current drawn by the individual making contact with a voltage. Since residual currents do not increase potential, there is no increase in shock hazard even though their accumulation on the EGC can cause a current imbalance that will cause GFCI to nuisance trip. Another drawback to placing a master GFCI on a generator is that even a minor fault in one piece of equipment will take out every piece of equipment operating on the generator. In a music production, a stage can lose all of its back-line power as a result and the band will go mute. In motion picture production, the consequences can be even more catastrophic and possibly even life threatening given the nature of movie production. For example, imagine the typical indie movie set powered by a portable generator at night. Unlike a road crew working at night, a movie crew uses the ambient light generated by the movie lamps illuminating the set as their work light because separate work lights would pollute the lighting effect they are trying to accomplish. Under these circumstances, should a master GFCI nuisance trip the entire distribution system will go down leaving the crew figuratively in the dark on where the leak occurred while the entire set is literally left in the dark inhibiting their ability to get the lights back on. Furthermore, if the master GFCI tripped because a crewmember received an actual electrical shock, the darkness will compound the hazard by inhibiting aid being administered to the shocked individual. (For a similar reason, even though NEC 525.23 requires GFCI protection for almost all 15 A and 20 A, 120 V outlets located outdoors, it does not permit egress lighting to be powered by a receptacle protected by a GFCI.) While placement of GFCIs on generators may work adequately in applications involving tools, they clearly do not work in motion picture and event staging applications. So, what is a conscientious technician to do when they have to operate a portable generator in wet hazardous conditions? One could argue that a simple remedy is to not earth ground the generator. According to this argument, if the generator is not grounded with a ground rod, earth cannot serve as a fault path. Fault current will thereby not go to earth and there is no potential exposure to electric shock. While this argument holds some validity for diesel tow plants, which are easily insulated from earth, it does not hold true in the case of small portable generators under 15 kva. A recent study conducted by The Construction Safety Association of Ontario (CSAO) found that it is very difficult to insulate small generators from earth. In fact, the CSAO study discovered that operating a portable generator on wet ground can earth it, creating a possibly hazardous situation in the event of a fault. What is a conscientious technician to do? First, they should avoid using construction-style generators that have master GFCIs. Since the recent code revisions discussed in Part 1 require GFCI protection only on 20 A and 30 A 120 V receptacles, many generators, like the Honda EU6500 or EU7000 inverter generators, do not have GFCI protection on their 240 V receptacles. Which means that a construction-style splitter box like that pictured in Figure 2 can be used on one of these generators to split out their 240 V receptacle into two 120 V circuits. These boxes typically Figure 2 A construction-style splitter box with GFCI protected branch circuits. further divide the 120 V circuits into smaller 20 A and 30 A 120 V branch circuits, each protected by a GFCI. This approach, which places the GFCI at the load rather than at the generator, offers some distinct advantages. Figure 3 A horizontal discrimination strategy for ground-fault protection First, it segments the distribution system into zones and thereby reduces the residual and leakage currents seen by any one individual GFCI. If each GFCI has only one or two loads on it, it is less likely to nuisance trip because residual currents are less likely to reach the GFCI s trip threshold or sensitize it to transient conditions. Second, should the GFCI trip under fault conditions, power is lost only to the individual circuit and not the entire distribution system, making it easier to identify the faulty load. And third, because it is close to the load, the GFCI will more reliably remove dangerous fault conditions because there is less opportunity for fault current 25 PROTOCOL

to return to the neutral conductor before passing through the GFCI s CT as we saw in Part 1 of this series. Called a horizontal discrimination strategy, this approach to ground-fault protection, is still far from ideal. One problem is that the GFCIs used in these distribution boxes are of the inexpensive hardware-type with less lenient trip curves than what is allowed by UL 943. Depending on the type of loads used, these boxes may also be unsuitable because their GFCIs do not incorporate high frequency filtration. For instance, the high frequency residual currents generated by some loads (like the Kino and HMI ballasts discussed in Part 2) will trip these GFCIs even when there is no other load on the circuit (making constructionstyle splitter boxes unsuitable for many event staging and motion picture applications.)... for there to be a shock hazard (I>8 ma) there must be a voltage source (V), a closed circuit (someone making contact with two points at different voltage), and a low resistance (R). Figure 4 A 100 A/240 V Shock Block GFCI located immediately after the common bus of paralleled Honda EU6500 generators provides blanket protection to the 240 V distribution system. A transformer steps-down the 240 V output of the paralleled generators into a single 100 A/120 V circuit, that can power a large light as well as be broken down into smaller 20 A branch circuits using standard film-style distribution equipment. A 100 A/120 V Shock Block GFCI located immediately after the transformer provides blanket protection to the 120 V distribution system. As a separately derived system, the transformer segments the distribution system in a tiered fashion, while GFCIs on the individual 20 A/120 V branch circuits of the lunch box segment it in a horizontal fashion, thereby eliminating the nuisance tripping of the GFCIs. The only solution to noisy loads is to isolate them to a circuit that is protected by a film-style GFCI further upstream. For example the 100 A Shock Block in Figure 4 above protects both a 4K HMI as well as loads operating on dedicated GFCI protected circuits provided by a GFCI lunchbox in this case. A film-style GFCI that employs high frequency filters and a trip curve that more closely approximates the inverse-time curve of UL 943 will be less prone to nuisance tripping from the accumulated residual currents of these loads. Another problem with a strictly horizontal discrimination strategy is that the main feeder trunk between the generator and the GFCI protected branch circuits (section K in the illustration above) remains without active protection. This hole in protection can expose personnel to shock hazards from something as common as nicked cable insulation. Even absent a clear shock hazard, a strictly horizontal discrimination strategy is inadequate because multiple small faults (each less than 4 ma) that individually won t trip a GFCI at the load will run together, like many ground springs running together to form a stream, as they all return to their common source, the generator. Under such circumstances, someone touching the generator may receive a severe shock, while someone 26

else touching an individual load with a small leak of less than 4 ma will just experience a tingle. The first step to solving this problem is to use a film-style 240 V GFCI at the generator(s) as depicted in Figure 4. Even though it provides blanket protection, a film-style GFCI will be less prone to nuisance tripping in this position than the master GFCI discussed above because of their high frequency filters and more lenient trip curve. This is only a partial solution however, as a Class A device, its trip threshold (4-6 ma) is low for a GFCI offering blanket coverage. Over an entire distribution system, the 50/60 Hz component of residual current (that we saw in Part 2), on top of small ground leaks, may still cause it to nuisance trip because of its low threshold. Since there are no Class C GFCIs with higher trip thresholds suitable for this application (the smallest available is 200 A per phase, three-phase), the second step towards improving service continuity and system safety is to use a small step-down transformer (like that discussed in Part 2) to step down the 240 V output of the generator to 120 V rather than splitting it out with a constructionstyle splitter box. As a separately derived system a transformer creates a new impedance point to which ground leaks will return rather than return to the generator. Since current returns only to the unique magnetic field from which it was generated, the introduction of a transformer segments the distribution system into two tiers. Only ground leaks upstream of the transformer will return to the magnetic field of the generator s stator, those downstream will return to the transformer s core. The net effect is that both the 240 V GFCI at the generator and the 120 V GFCI at the transformer in Figure 4 above see considerably less current imbalance from small ground leaks and so are less prone to nuisance tripping. While segmenting the distribution system in a tiered fashion offers greater protection against nuisance tripping, it is still not ideal because in the event of someone receiving an electric shock all GFCIs (both upstream and downstream) will trip and throw the set into darkness, thereby inhibiting aid being administered to the shocked individual. The reason for this is that the impedance of the human body is such that according to Ohm s Law both film-style and hardware-style GFCIs will trip at the same time. To see why this would be the case all we have to do is plug some numbers into Ohm s voltage equation (V= IR). But before we do so, it is important for the math-phobic among us to appreciate that Ohm s voltage equation is not just an abstract mathematical formula. What it means from a practical standpoint is that for there to be a shock hazard (I>8 ma) there must be a voltage source (V), a closed circuit (someone making contact with two points at different voltage), and a low resistance (R). The degree of hazard (I) is, according to Ohm s Law, inversely proportional to the resistance of the individual that completes the circuit. For example, a film electrician can be working outside with a defective light and not receive a noticeable shock when the ground is very dry. That same person with the same light can receive a life threatening shock when soaked by rain (real or manufactured) because the resistance of the ground-fault circuit is greatly reduced by the mineral ions in water that make it a good conductor. Under such circumstances, the resistivity of his/her body will determine how much current he/ Figure 5 A tiered strategy for ground-fault protection. A 100 A/240 V Shock Block GFCI (left) provides blanket protection to the 240 V distribution system. A 100 A/120 V Shock Block GFCI (right) provides blanket protection to the 120 V distribution system derived from the 240 V output of the generators by a step-down transformer. Figure 6 Body resistance model 27 PROTOCOL

she will draw and consequently the amount of a shock they will take. Put simply, the human body acts like a resistor in an electrical circuit and its resistance, as measured in Ohms, determines how much current will flow in the circuit (a ground-fault circuit in this case.) Figure 6 below depicts a body resistance model (the resistive values are for an average person doing moderate work). To calculate the amount of current our rain-soaked electrician will draw, we use the hand-to-foot resistance of 1,100 ohms (500 + 100 + 500 = 1,100 ohms). Since in this case we are concerned about the effects of current (I) on the human body, we will restate the formula as follows: I = V/R. Plugging numbers into this equation we see that, according to Ohm s Law, the electrician would take a shock of 0.109 amps (I = 120/1,100 = 0.109 amps.) If we multiply 0.109 amps by 1,000 to convert to milliamps we get 109 ma, which as we learned in Part 1 of this series, will send an individual into cardiac arrest if power is not cut off in less than a second. For this reason, both film-style GFCIs and hardware-style GFCIs are required by UL 943 to trip almost instantaneously (within two hundredths of a second) when leakage current can be lethal. To assure service continuity so that the entire set does not go dark in the event of a catastrophic fault like a shock, upstream and downstream GFCIs must be discriminated by trip time. Part 4 of this multipart exploration of how to safely use small portable generators in motion picture and live event production will pick up with how to discriminate between upstream and downstream GFCIs by trip time so that only the downstream GFCIs trip in the event of a ground-fault. Guy Holt has served as a gaffer, set electrician, and generator operator on numerous features and television productions. He is recognized for his writing on the use of portable generators in motion picture production (available soon in book form from the APT Press.) Guy has developed curriculums on power quality and electrical hazard protection that he has taught through the IATSE Local 481 Electrical Department s TECs Program. He is the owner of ScreenLight & Grip, a motion picture lighting rental and sales company that specializes in innovative approaches to set power using Honda portable generators. 28