Cool. NFF Series. CoolX600 NFF Series. Patented Resonant Technology. NFF Series; No Fan Featured

Similar documents
NFF Series. CoolX600 NFF Series Cool. Patent Pending Resonant Technology. NFF Series; No Fan Featured

Cool. NFF Series. CoolX600 NFF Series. Patent Pending Resonant Technology. NFF Series; No Fan Featured

CoolX CoolPac. CoolPac Slots Power. CoolX CoolMod. Vnom (V) CoolModel. Single Output Modules (1 Slot) High Power Modules (3 Slot)

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

Model Vnom Power Description Set Point Dynamic Vtrim Imax Remote Power (V) (W) Adjust Range (V) Range (V) (A) Sense Good

solo Ultra-high efficiency 1U size Xsolo Single Output Power Supply 500W W 2 FEATURES APPLICATIONS INCLUDE

XSOLO ULTRA-COMPACT, HIGH-EFFICIENCY 500 W AND 1000 W SINGLE OUTPUT POWER SUPPLIES

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product datasheet

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

C B. Models. Models 2MOPP

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

MVAB120 Series 120W 2" x 4" AC-DC Power Supply Converter

MAD40 MULTI -OUTPUT SERIES OPP SCP OVP. 2 X 3.5 Inch AC-DC POWER SUPPLIES. UNIVERSAL INPUT RANGE UP TO 40Watts PART NUMBER STRUCTURE LOW CROSS REG.

General. Environmental. EMC & Safety

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

Doc. EA Model Number:

Medical / Industrial AC-DC Power Supply 1200W with 5V/2A Standby / MEB-1K2A series

Features. Regulated Converters. RACM40 40 Watt Enclosed & Open Frame Case Style Single Output RACM40- S / - AC/DC Converter.

Electrical Specifications

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

Industrial Serie +600S

General. Environmental. EMC & Safety

Features. Regulated Converters. RACM Watt Enclosed Case Style Single Output. RACM150- S/ _ Fan Option (1) Single. AC/DC Converter.

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

150 Watt Industrial (WLT)

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

TECHNICAL DATASHEET MDS Medical AC-DC Open Frame 065APS18 B Highlights & Features Safety Standards Model Number: Unit Weight Dimensions (W x L x H):

Electrical Specifications

Note1: Max Cap Load is tested at minimum input and full resistive load. Connections (3) Case Style (1)

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

LB115S 115W Single Output

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1. Automation Datacom IPC. Industry Measurement Telecom

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

Output Power Output Voltage (3) Output Current Total Regulation (2) Efficiency (5) Model Number (1,6) 8 W 3.3 VDC 2.50 A 7% 68% AEL15US03 (4) 12 W

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

DDP400 and MDP400, SC series, are sealed, full potted, compact, high efficiency, small form factor AC-DC power supplies.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

CLP0112 Open Frame Power Supply Vac input; 12Vdc output; 150W Output Power

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

M A D 65 U S 12 B - PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

Electrical Specifications. Input Current 115 VAC: 1.2 A max. 230 VAC: 0.65 A max.

The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.

Compliance. Safety Approvals USA Canada Europe. Isolation: General. Dimensions. AC Input CN1 Output CN2 Optional CN3. Weight

MB120S 120W Single Output Medical Series

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

Output Voltage (Vfan) & Current

Output Voltage* (nom.)(adjustable)

NEVO+1200M. 6 x6 x W. 1.2kg DATA SHEET MAIN FEATURES

Output Voltage (Vfan) Convection-cooled (6,7) Forced-cooled (8) & Current

Model and Output Power Output Nominal Voltage Package Option Means of Protection Grade. 12 V DC: -US12 Open Frame: -OF. 24 V DC: -US24 U-Chassis: -UC

Voltage Adjustment. Load Regulation

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

PDAM500 Series 500W Power Supply

VOF XX - XXX - X

TB65 65W Single Output Test and Measurement/Industrial Series

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Features. Regulated Converter RACM Watt Enclosed & Open Frame Case Style Single Output RACM65- S / - AC/DC Converter.

IMA 1000 Watts Power Supply Series. for medical and industrial applications. Product data sheet

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DDP400 SERIES KEY FEATURES DESCRIPTION MARKET SEGMENTS AND APPLICATIONS

IMA 600 Watts Power Supply Series. for medical and industrial applications. Product data sheet

CCH400 & CCH600 Series

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

Electrical Specifications

TE60 60W Single Output External Power Test & Measurement/Industrial Series

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Metal Case Power Supplies

TE60 60W Single Output External Power Test & Measurement/Industrial Series

LFWLP W 12V 15.00A 25.00A 92%

Features. Regulated Converter. REM6 6 Watt 2:1 & 4:1 DIP24 Single and Dual. Output. DC/DC Converter

FEATURES AND BENEFITS. Compact size: 6.5 x 2.8 x 1.5

Load (2) Single or Dual

For more information, please visit the product page. output. output current max (A)

Model Selection Model Output Current Total OVP Number Class Volts (Convection Cooled) Efficiency 1 Ripple &Noise 2 Regulation Threshold

CB Scheme UL508 UL ATEX II3G

Output Full Load

VMS-300A - XX - XXX - X

5 x 3 x 0.75 Inches form factor. 275 Watts with Forced Air Cooling. Efficiencies up to 92% Standby Power < 0.5 W

(*) Reference the User Manual or contact the factory for parallel operation between modules plugged into slots 1/2/3/4 and slots 5/6/7/8.

IP67 DESCRIPTION KEY FEATURES MARKET SEGMENT AND APPLICATIONS TRC ELECTRONICS, INC

Load (2) Single or Dual

IMA 400 Watts Power Supply Series. for medical and industrial applications. Product data sheet

Electrical Specifications. Adjustment range Main output ± 5% Total regulation (line and load) ± 2.0% ± 5.0% Turn-on 120 Vac Input 2.0 s max.

Sirius 250/350 Watts, Single / Multi output AC-DC, modular power solution

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

Transcription:

Cool TM 600 NFF Series Patented Resonant Technology NFF Series; No Fan Featured 100% natural convection cooled No internal or external fans needed No base-plate needed No Acoustic Noise or Vibrations & Breakthrough Level Reliability - No fans required 600W with natural convection - MTBF >00000 hours - 25% better, than todays leading solutions High Input Surge Protection - KV Line to PE for harsh environments Reverse Energy Protection - No blocking diodes required 2W Standby Power Safety Approved to 5000m Altitude >93% Efficiency 5 Year Warranty Flexibility Analog and Digital Management - PMBus monitoring and control capability Field Configurable - Plug and Play Power Series and Parallel Outputs - Higher voltages/currents Mounting Options - Base/Side and DIN-Rail mounting Certifications Medical - IEC60601-1 3rd Edition compliant - IEC60601-1-2 th edition EMC compliant - 2 MOPP - Dual Fused - BF rated - ISO1385 Industrial - IEC60950, IEC62368-1 - ISO9000 - SEMI F7 Defence/Aero - MIL810G certifi ed - MIL61G, CE101, CE102 TYPICAL APPLICATIONS Medical; Clinical diagnostic equipment, Medical lasers, Dialysis equipment, Radiological Imaging, Clinical Chemistry Industrial; Test and Measurement, Industrial Machines, Automation equipment, Printing, Telecommunications, Audio equipment Hi Rel; Harsh Industrial Electronics, Radar (Naval, Ground Based), Communications Test & Measurement The World s Only Fanless modular power supply, the is the revolutionary new Convection-Cooled modular power supply from Excelsys. It provides an incredible 600W in a compact.5 x 8.5 x 1U package with no fan. The silent CoolX600 generates no acoustic noise and offers system designers best in class performance in effi ciency (>93%) and unrivalled reliability in addition to the most comprehensive feature set and specifi cations. The series comprises two base models. The CX06S is certifi ed to IEC60950 2nd edition for industrial applications whereas the CX06M carries IEC60601-1 3rd edition & IEC60601-1-2 th edition (EMC) for medical applications. The CoolX600 can be populated with up to CoolMods, providing up to isolated DC outputs ranging from 2.5V to 58.0V. Continuing the Excelsys tradition of fl exibility, the CoolX600 is completely user and fi eld confi gurable. Outputs can be adjusted to the required set point voltages and can be confi gured in parallel or series for higher current and/or higher voltages. CoolPacs can be paralleled for higher power and N+1 Redundancy applications. Stand-out features for medical applications include BF rating (Body Floating), input dual fusing, 2 x MOPP isolation and <300uA leakage current. Other features include KV input surge immunity, SEMI F7 compliance, MIL810G compliance and the ability to withstand input voltages of up to 300VAC making it ideal for use in remote locations and those subject to input voltage disturbances. No fans make it ideal for acoustic and vibration sensitive applications. With Digital Communications available, the CoolX600 provides the most fl exible, highest specifi cation modular power supply in the market, all backed up by the Excelsys 5 Year Warranty ensuring quality and the lowest total cost of ownership CoolX CoolPac CoolPac Slots Power CX06S CX06M Model CmA CmB CmC CmD CoolX CoolMod 600W 600W Vnom (V) 5 12 2 8 Medical Approval IEC60601-1 3rd edition & IEC60601-1-2 th edition (EMC) - Yes Set Point Adjust Range (V) 2.5-6.0 6.0-15.0 15.0-28.0 28.0-58.0 Imax (A) 21 15 8.33.17 Industrial Approval IEC60950 2nd edition Yes - Power (W) 105 180 200 200 1

INPUT AC Operating Input Range 85 26 VAC Nominal Input Voltage Range Universal Input 7-0Hz 100 20 VAC Extended AC Operating Range Maximum for 5 seconds 300 VAC DC Input voltage range 120 300 VDC Input Current 90VAC @ 20W 6.0 A Inrush Current 230VAC @ 600W 25 A Power Factor 120VAC@ 500W 0.98 Undervoltage Lockout Shutdown 65 7 VAC Input Fuses Rating Dual Fused (Line and Neutral) 250VAC 8 A Effi ciency 230VAC, 600W with 3 x CmC CoolMods 93 % COOLMOD OUTPUT Parameter Conditions/Description Min Nom Max Unit Power Rating CX06: See derating curves 600 W Minimum Load 0 A Line Regulation For ±10% change from nominal line ±0.1 % Load & Cross Regulation For 25% to 75% load change ±0.2 % Transient Response For 25% to 75% load change 0.5A/uS: Voltage Deviation Settling Time Ripple and Noise 100mV or 1.0% pk-pk. 20MHz BW 1 % Overvoltage Protection Tracking OVP Level 105 125 % Latching OVP Level 125 160 % Remote Sense Max. line drop compensation 0.5 VDC Overshoot 1 % Rise Time Monotonic 10 ms Turn-on Delay From AC in From Global Enable From CoolMod Enable 800 10 10 ms ms ms Hold-up Time For nominal output voltages at full load 20 ms CoolMod Power As per CoolMod table Output Adjustment Range Manual: Multi-turn potentiometer. As per CoolMod table Vtrim: As per CoolMod table Overcurrent Protection Straight line with hiccup activation @ 35% Vo nom 110 130 150 % Short Circuit Protection OverTemperature Protection Yes, Autorecovery Yes, Autorecovery Capacitive Load 10 mf 500 % µs AUXILIARY OUTPUT Nominal Output Voltage Aux Voltage Option A 11.76 12 12.2 V Aux Voltage Option B.75 5 5.25 V Load Regulation ±2 % Line Regulation For ±10% change from nominal line ±0.5 % Maximum Output Current Aux Voltage Option A Aux Voltage Option B 1.96.7 A A Maximum Output Capacitive 1000 uf Load Output Overcurrent Protection Hiccup 110 10 % Short Circuit Protection Yes, Autorecovery GALVANIC ISOLATION Input to Output Reinforced (2 x MOPP) 000 VAC Input to Case Basic (1 x MOPP) 1850 VAC Output to Case Basic (1 x MOPP) 1850 VAC Output to Output Basic (1 x MOPP) 1850 VAC 2

RELIABILITY Reliability and MTBF Warranty MTBF of >00 khours, Telecordia SR-332, Issue 1 CoolMod CoolPac 5 Years 0.52 1.08 Fpmh Fpmh ENVIRONMENTAL Operating Temperature Operates to specifi cation below -20 C after 10 min warm-up -0 +85 C Storage Temperature -0 +85 C Derating See Derating Curves including note 2 Relative Humidity Non-condensing 5 95 %RH Shock & Vibration MIL-STD810G Method 51.6 Altitude 5000 m LEAKAGE CURRENTS Parameter Conditions/Description AC Leakage Current Input to earth ground Units Normal condition (high line) Mains Voltage 26VAC/60Hz µa Single fault condition (high line) Mains Voltage 26VAC/60Hz 231 µa Touch Current Normal Condition Mains Voltage 26VAC/60Hz 83 µa Single Fault Condition Mains Voltage 26VAC/60Hz 87 µa EMC Parameter Conditions/Description Criteria Radiated Emissions EN 55011, EN 55022 and FCC, Class B Conducted emissions EN 55011, EN 55022 and FCC, Class B Power line harmonics EN 61000-3-2, Class A Voltage fl icker EN 61000-3-3 ESD EN 61000--2, level, 8 kv contact, 15 kv air A Radiated immunity EN 61000--3, level 2, 3 V/m A Electrical fast transient EN 61000--, level, ± kv B Surge immunity EN 61000--5, level, 2 kv DM, kv CM B Conducted RF immunity EN 61000--6, level 2, 3 Vrms A Power frequency magnetic fi eld EN 61000--8, level 2, 3 A/m A STANDARDS & DIRECTIVES 1) Parameter Conditions/Description Safety Agency Approvals EN60601-1 3rd Edition, UL60601-1, CSA601, EN60950 2nd Edition, CSA C22.2 No. 60950-1, IEC/EN 60950-1, Edition 2 and UL 60950-1/CSA 22.2 No 60950-1, Edition 2; all national deviations 5000 m (16,00 ft) altitude, 100 V to 20 ±10% Vac IEC/EN 60601-1, Edition 3 and IEC 60601-1(2005), EN60601-1(2006) all national deviations ANSI/AAMI ES 60601-1(2005) CAN/CSA C22.2 No. 60601-1 (2008); 5,000 m (16,00 ft) altitude, 100 V to 20 Vac ±10% IEC 62368 Edition 2 IEC 62368-1 (201) Edition 2 5000 m (16,00 ft) altitude,100 V to 20 ±10% Vac IEC 60601-1-2 Edition IEC 60601-1-2 (201) Protection class WEEE ROHS REACH Class I Waste Electrical and Electronic Equipment Directive (WEEE) 2002/96/EC EU DIRECTIVE 2011/65/EC RoHS compliancy Compliant 1) Designed to support Type B and Type BF Applied Part End Product Requirements 3

MECHANICAL DATA Parameter Description Dimensions (L x W x H) L x W x H 215.9mm x 11.3mm x 39.1mm.5 x 8.5 x 1U Weight Nominal Weight: CoolPac + x CoolMods 1Kg Connectors Description Mating Connectors (if applicable) AC/DC input terminal block AC/DC IEC input (Option) Main DC output terminal block TE 2-137667-S, DINKLE DT-35-B07W-03 IEC 320 Inlet M Screws System Signal Connector J1005 Molex 87833-0831 8-way Locking Molex 51110-0860; Non Locking Molex 51110-0850; Crimp Terminal: Molex p/n 5039 or Molex 51110-0856 which includes Locking Tab & Polarization Keying Output Signal Connectors J1001-100 Molex 87833-0631 6-way Locking Molex 51110-0660; Non Locking Molex 51110-0650; Crimp Terminal: Molex p/n 5039 or Molex 51110-0656 which includes Locking Tab & Polarization Keying Output Sense Connectors J3 JST-S2BPH-K(LF)(SN) JST PHR2. Crimp Terminal JST BPH-002T-P.0.5S or SPH-002T-P.05S Auxiliary Output Connector J1 Molex 101880210 2pin CoolX Mechanical Drawings 6.00 162.00 19.55 3.00 215.90 2.25 2.25 2.25 11.30 36.15 2.00 39.10 31.50 122 CoolX can be mounted on its base, vertically or on its side. CoolX can also be mounted on the Excelsys DIN Rail accessory (Z7).

CoolX 600 Efficiency, Dera ng and Power Limit Curves 115V 230V CoolX Dera ng 2) Enhanced thermal performance with system fans & base plate cooling. Consult Excelsys for details. Configuring Your CoolX 5

CoolX Connectors Input Connectors Standard (Screw Terminal) CoolPac Connectors Op on 1 (IEC Terminal) CoolMod Connectors Specifications are subject to change REV 1.0.0 6 Europe/Asia North America Excelsys Technologies Ltd.t: +353 21 35716 Excelsys Technologies t: +1 972 771 5 27 Eastgate Drive f: +353 21 3586 80 Bricketts Mill Road, f: +1 972 21 1805 Eastgate Business Park e: sales@excelsys.com Hampstead, e: salesusa@excelsys.com Little Island New Hampshire Co. Cork 0381 Ireland USA