INSTALLATION MANUAL Sluice Gates, Stop-logs & Screens

Similar documents
MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

Rodney Hunt. A GA Industries Company Glydaseal Gates

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

SPECIFICATION: ALUMINUM SLIDE GATES

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Fisher 667 Diaphragm Actuators Size 80 and 100

Installation, Operation and Maintenance Manual. RB Weir Gate

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

PENSTOCK VALVES. Performance through Excellence

Mechanical Actuators

CV Control Valves Installation and Operation Manual

E N G L I S H GARDEN SHED. Assembly Instructions. Suitable for Models WITH VARYING DEPTHS

YALE FIGURE 500 & 500R CLOSURE OPERATION AND MAINTENANCE INSTRUCTIONS

MODEL 200/220 ASSEMBLY INSTRUCTIONS

INSTRUCTION MANUAL Q-HYDRAULIC

YONGJIA NSV VALVE CO.,LTD. GATE, GLOBE & CHECK VALVES ASSEMBLY & MAINTENANCE PROCEDURES

Model: 3-IN-1/1067x1.5 Model: 3-IN-1/1320x1.5

Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher

Fisher 667 Diaphragm Actuator Sizes 30/30i 76/76i and 87

Typical Group D Rear Acoustical Cover Installation

General Four-Way Operation, Maintenance & Service Manual

MODEL H " BYRD SHELIX CUTTERHEAD INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Inventory (Figure 2)

Motorized Tower Raising System Manual

PENSTOCKS Sluice Gates

HEAVY DUTY CENTRIFUGAL PUMPS

Oxford Stalls Installation Instructions

4-8 HSF 250 Patriot. Line Stop Fitting Installation Instructions. Installation Instructions and Best Practices continued on back

CONSTRUCTION MATERIALS

OWNER'S MANUAL TIE ROD, WALL & FLOOR MOUNTED JIBS. Model JIB-HC, JIB-LC, JIB-FM

UNPACKING. Thank you for purchasing the Manual Capsule Filling Machine from KARISHMA PHARMA MACHINES.

6o ft (18.3 m) Southwest Windpower, Inc West Route 66 Flagstaff, Arizona USA Phone: Fax:

Section Heavy Duty Slide Gates Tender No. [ ] Page 1

COYOTE ENTERPRISES, INC. RIMLOC BLAST WHEEL MAINTENANCE & ASSEMBLY MANUAL

SLIDE GATE. The MU series is used mainly in water treatment, irrigation, hydraulic works and hydro-electric power plants.

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

Cast Iron Slide Gates

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

AFB (AIR FAN BEARING) INSTALLATION GUIDE

INSTALLATION INSTRUCTIONS for the JOMY RETRACTABLE LADDER. If there are any questions, please call (800)

Installation Instructions TMW Antenna Tower Mount for 4ft (1.2m) Antennas.

1. Turn off or disconnect power to unit (machine). 2. Push IN the release bar on the quick change base plate. Locking latch will pivot downward.

ClearSpan End Frame Kit 30' Wide x 11' High

DODGE Grease Lubricated SPLIT-SPHER Roller Bearings and Pillow Blocks

Horizontal Cable Systems

BISON GOOSENECK FOOTBALL 1 PAIR OF GOAL POSTS

Assmann Corporation of America TANK INSTALLATION AND USE GUIDELINES FOR BULK STORAGE TANKS

EKSPAN. Standard F Series Bearings. Description. Bearing types F series bearings are available in three forms - Typical 21F details.

SERIES 4200 TYPE W PRESSURE GATE. Installation, Operation & Maintenance Manual. Manufactured by:

WALK-BEHIND SPREADER 50 LB. CAPACITY Model 99623

ELEGANCE SHOWER DOOR/ENCLOSURE INSTALLATION INSTRUCTIONS. Style A Style B Style C Style D

RITE-HITE RAINGUARD TM

Installation Manual for Gate Guard

Fisher 657 Diaphragm Actuators Size 80 and 100

All American Mower Blade Sharpener Mulching Blade Model Patent Pending

ClearSpan End Frame Kit 26' Wide x 12' High

Pow-R-Feed Systems Service Manual

HEAVY DUTY HG560 CAST IRON SLIDE GATE

VINYL CLASSIC FREESTANDING PERGOLA ASSEMBLY INSTRUCTIONS

9 questions to ask when specifying a slewing ring bearing

400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS

No. 412, 414, 416 Operations Manual

4.4 PUMP MAINTENANCE MODELS: DB, DC, DF, DG, DJ, DL

Hardinge FlexC Collet System Style D 65mm

Owner s Manual ODYSSEY BENCH MODEL. O4100B shown REV E. Southern Avenue, Phoenix, AZ USA Workhorseproducts.

OPERATION AND MAINTENANCE INSTRUCTIONS AVK UNDERGROUND FIRE HYDRANT

Precision Steel Car s 100 T Steel Coil Car

Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation

SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL

Reliance SG800 Series Steel Water Gage Valves

SLIDE GATE SERVICE CONDITIONS

Installation, Assembly, and Operation Manual: Multi-Section Prestige Flagpole

PROPELLER SHAFT GROUP CONTENTS GENERAL INFORMATION SPECIAL TOOLS SERVICE SPECIFICATIONS PROPELLER SHAFT...

Heavy and Medium Duty Fire Doors

VB36 SHORTBED.TAILSTOCK

Hardinge FlexC Dead-Length Collet System Style DL 42mm. Installation Instructions and Parts Lists

Thank you for purchasing our product! *Please read these instructions and follow them step by step.*

SECTION METAL FABRICATIONS

Introduction... 2 Scope of Manual... 2 Description... 2 Specifications Installation... 2 Actuator Mounting... 3 Loading Connection...

Page 1. SureMotion Quick-Start Guide: LACPACC_QS 1st Edition - Revision A 03/15/16

INSTALLATION INSTRUCTIONS

Geology, Prospectors, Mining, Metallurgy, Assaying, Environmental, Geotechnical

Lumber Smith. Assembly Manual. If you are having problems assembling the saw and need assistance, please contact us at:

HANDHOLE SEAT GRINDER

Studio Face Xtreme 6020 Installation Instructions (Nickel , Black )

INSTALLATION MANUAL IOWA MOLD TOOLING CO., INC. BOX 189, GARNER, IA MANUAL PART NUMBER:

Dura-Lock Roof System

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

BETTIS SERVICE INSTRUCTIONS FOR MODELS G01 THROUGH G10 SERIES HYDRAULIC SPRING RETURN ACTUATORS WITH M11 HYDRAULIC OVERRIDE

Table of Contents. B. Base Tool Changer...2 MC-36 Manual Tool Changer...2

SET-UP & MAINTENANCE GUIDE. DME Helical Gear Stack Mold Centering Devices

Product Guide Specification

Installation - Sub Cills

PAT installation of a Sun Dome over a in-ground

Floating Lake Truss Dock Instructions

SawStop. T-GlideTM. Fence System- Professional Series II OWNER S MANUAL

DYNATRAC BALL JOINT REBUILD INSTRUCTIONS V5.0

25000 Series Lo-T TM Butterfly Control Valve Instructions

Transcription:

INSTALLATION MANUAL Sluice Gates, Stop-logs & Screens INTRODUCTION During manufacture and assembly of equipment great care is taken to ensure accuracy in mating the sealing faces on frame and doors, especially on metal seated units. It is essential; therefore, that Sluice Gates should be erected accurately, free from distortion and treated with care. The sluice gates door must not be removed from the frame prior to erection. The Frame prior assembly must be kept together as one unit to provide the most rigid structure to avoid distortion / damage to the sealing faces during erection. If the sealing faces are distorted or damaged in any way during erection. If the sealing faces are distorted or damaged in any way during installation the degree or sealing / leakage attainable will be affected directly. Through on the following pages we detail recommendations for installing the Sluice gates, Wall brackets and Hoist using foundation bolts are for guidance. The procedure can be adjusted according to actual site conditions. If the Sluice Gates is not to be used for some considerable time after installation, due to other site activities It is suggested that the Sluice Gates door is well covered with tarpaulin sheets or similar to avoid foreign objects from loading on the top of gate and becoming entrapped between the seals causing consequential damage. UNLOADING AND PACKING Please unload all the material by using crane. Please use the holes and bolts are provided for unloading of the gates. Gate frame and Gate plate and packed together. Please unload the same in the same condition. While unloading please check all the material as per delivery challan. Packing should be removed only when the erection is to be commenced. HANDLING AND STORAGE If the Sluice Gates are not to be used immediately after unloading the same should be stored well covered with tarpaulin sheets. Other material like spindles, nut bolts, gunny bag, and hoist hand wheel indicator pipe should be stored in the safe place. Place the thimble in the correct position in the forms and secure in place. The top and bottom center line is marked on the flange face and should aligned with the a plumb. The thimble should be flush or projecting slightly from the hand wheel face. Use thimble or other bracing on the inside of the opening to support the thimble and prevent war page during the pour. This is particularly important on the larger thimbles or when the concert. Cover will be especially high. Plug the trapped holes in the thimble while pouring the concrete. After concrete is over the holes should be made free. Take care not to tilt or move thimble from its original position. Let the concrete set then clean the front machined face of the thimble. Web : www.yashwant.biz More Information: yiw.online@gmail.com 1 P a g e

INSTALLATION OF WALL THIMBLE YASHWANT INDUSTRIAL WORKS PVT.LTD Place the thimble in the correct position in the forms and secure in place. The top and bottom centre line is marked on the flange faces and should be aligned with a plumb. The thimble should be flush or projecting slightly from the headwall face. Use thimble or other bracing on the inside of the opening to support the thimble and prevent warpage during the pour. This is particularly important on larger thimbles or when concrete cover will be especially high. Plug the tapped holes in the thimble while pouring the concrete. After concrete is over the holes should be free. Take care not to tilt or move thimble from its original position. Let concrete set than clean that front machine face of the thimble. INSTALLATION OF GATE ON THE WALL THIMBLE Clean the back flange of the gate frame thoroughly. Apply a thin coat of grease on the front face of thimble and mount the complete assembled gate on the thimble. Place bolts and tighten uniformly (Normally tighten the diagonally opposite bolts) until a metal to metal contact is made. Fit foundation bolts projections are square. Place the nut on the foundation Bolts. Do not tighten it immediately. Once concrete is set then tighten the nut to the requirement. FIXING OF LIFTING RODS / STEM/ GUIDE BRACKETS After the gate has been mounted and shipping stops have been removed, place the lower end of stem with stem coupling in the gate plat. Insert threaded stem into stem nut. Mount stem guide and grout packet. Check bolts projections are square. Place the nut on the foundation bolt. Do not tighten it immediately. Once concrete is set then tighten the nut to the requirement. Install stem couplings as required. Make sure to tighten all the bolts with nuts of the coupling. Take care, not to bend stems or damage threads during installation. MOUNTING OF HEAD STOCK Place the headstock assembly and guide assembly on the platforms insert the anchor bolts for both the assemblies and grout the packets. Check bolt projection are square. Place the nut on the anchor bolt. Do not tighten it immediately. Once concrete is set then tighten the nut to the requirement. The threaded end of the stem is already inserted in the stem nut. Fix the pointer on the spindle and fix the indicator pipe is threaded at the bottom side from the outside. Check nut is also provided for the indicator pipe. Fix the hand wheel on the work shaft of the headstock. INITIAL SETTING OF GATE OPENING INDICATOR FOR RISING SPINDLE GATE The indicator pointer is provided should be fixed in the threads provided the spindle at the end portion of the spindle. After the indicator pipe is fixed on the cap of the headstock please check the indicator on O mark. Do not open or close the gate for achieving O mark. Web : www.yashwant.biz More Information: yiw.online@gmail.com 2 P a g e

FIELD ADJUSTMENT OF WEDGES YASHWANT INDUSTRIAL WORKS PVT.LTD As we have to install the total assembly of the gate frame and Gate plate wedges adjustment is not at all required because all wedges are perfectly set before dispatch. If there are leakages due to frame being twisted while erection the wedges adjustment may be required. The wedges on gate should be adjusted diametrically opposite each other commencing highest wedge on the side. Firstly fixing bolt should be loosened and then adjusted bolts should be unscrewed. Close the gats plate on matching face of frames. Tighten the adjusting bolts. Tighten the fixing bolts. Check with feeler gauge again. When the wedges are set the clearance should not exceed. PNEUMATIC & ELECTRIC ACTUATOR In case of use of actuator, please ensure that you have received the Instruction sheet for pneumatic or electric actuator separately from their respective manufacturer. Please see that you receive all the contact details of actuator manufacturer for any problems arise in future. The top & bottom limit settings are to be done properly with the help of competent person who understands the electric functioning of actuator or call the actuator manufacturer s authorized person at extra cost. Due to improper setting of limit switches of actuator it may cause the damage to the gate frame, Gate plate, wedges and other parts of the gate as well. Also please see that sufficient support is provided to Gate Frame & Yoke sides with concrete. This will effect smooth working of Actuator &lifting the plate. So utmost care has to be taken to mount & set the actuator. FIELD ADJUSTMENT OF FLUSH BOTTAM CLOSING GATE The seal is supported by Cast Iron bracket; The seal is held by stainless steel retainer bar bolted with Cast Iron bracket with stainless steel fasteners. Sealing pressure shall be varied by adjusting side and top wedges. Flush bottom assembly is not at alt to be adjusted. INITIAL OPERATION OF GATE AFTER COMPLETION OF INSTALLATION Clean Sluice Gate, open fully and carefully remove all foreign matter from the faces and invert. The faces, wedging and sliding surfaces and the opening screw should then be well greased. Every possible care should be taken to ensure that the faces are neither scratched nor damaged in any way. Otherwise Slice Gate can not be expected to seal under pressure. Now the gate is ready for use. Web : www.yashwant.biz More Information: yiw.online@gmail.com 3 P a g e

MAINTENANCE INSTRUCTION YASHWANT INDUSTRIAL WORKS PVT.LTD Each gate should be inspected thoroughly after every six months. Spindles and other working components should be lubricates after every six months. Use large diameter hand wheels should be avoided. The gates before regular use or after having been lift standing for considerable length of Time gate plate should be raised and foreign matter should be carefully removed. The contacting faces, spindles and other machined parts should be greased. Every Possible care should be taken to ensure that the faces are neither scratched nor damaged. ERRECTION AND COMMISSIONING INSTRUCTIONS Thimble, gate frames, gate plates and all other parts of sluice gates should be unloaded from vehicle very carefully. Crane should be used for heavy items for unloading. The machined faces nut bolts etc. should not be damaged at all while unloading. The gates are manufactured with grate care to insure accuracy in mating the faces of the door and frame. It is very essential therefore that the gates should be accurately erected. Free from distortion and treated with the gates must not be dismantled for fixing. The C.I. Thimble embedded in the concrete in the vertical line marked on thimble. The plumb line should be used for the front side (on which the gates frame is to be fixed on the thimble). The gate frame & gate plate jointly should be erected and mounded on the thimble after the due setting of concrete / grout of thimble. The top of the gate frame should be embedded in the concrete by stainless steel foundation bolts for rest of the frame stainless steel bolts should be used for gate frame & thimble fixing. After the grout is cured then tighten foundation bolt nut. Excessive tightness is not required. Clear opening hoist open fully and carefully remove all foreign matters from faces, wedging, sliding surfaces and opening screw. The face of sliding surfaces and operating screw should then be well greased. All wedges are perfectly set before dispatch. The wedges on gate should be adjusted diametrically opposite each other commencing highest wedge on one side. Firstly fixing bolts should be loosened and then adjusting bolts should be unscrewed. Close the gate plate on mating face of frame. Tighten the adjusting bolts. Tighten the fixing bolts. Check with feeler guage again. When the wedges are set the clearance should not exceed. Each gate should be inspected thoroughly After every six months; Spindle and other working components should be lubricated after every six months. Use of large diameter hand wheels should be avoided. The gates before regular use or after having been left standing for considerable length of the gate plate should be raised and foreign matter carefully removed. The contacting faces, spindles and other machined parts should be greased. Every possible care should be taken to ensure that the faces are neither scratched nor damaged. Web : www.yashwant.biz More Information: yiw.online@gmail.com 4 P a g e

DO S AND DONT S Before Sluice gate is put into regular services or after having been left standing for considerable length of time the door should be raised and all foreign matter carefully removed from faces, guide grooves and the invert area. The sealing faces, guide wedge faces, screwed stems and any other machine parts should then be well greased. Do not use large hand wheels, tee keys, other than those originally supplied. Every Sluice gate should be operated at least once every three months and checked for signs of wear / corrosion every six months. The nuts of all constructional and foundation bolts should be checked for tightness after every twelve months. On installations which are subjected to vibration due to high water velocity acting on the gate all the bolts / mits should checked more frequency for tightness. If the sluice gates are installed in situation where debris or foreign matter can be built up, we recommend that the Sluice gates should be periodically inspected. The protection paint should be examined after every six months for signs of damage and be repainted as required. The screw of each gate should be cleaned inspected for wear and regressed every six months. The grease nipples should be greased after every six months. The stem nut should be checked after every twelve months for signs of wear and be replaced if necessary. Badly worn threaded shearing and clause the gate to fail without warning. If frequency of operation is greater than this or operation condition, are more severe inspection should be carried out at shorter internals to suit. When the stem protection cover is supplied these should be removed every six months and the stem cleared inspected for wear and regressed prior to refitting of the cover. Use of large diameter hand wheel should be avoided. The gates before regular use or after having been lift standing for considerable length of time gate plate should be raised and foreign matters should be carefully removed. The contacting faces, spindles and other machined parts should be greased. Every possible care should be taken to ensure that the faces are neither scratched nor damaged. HANDLING AND STORAGE If sluice gates are not to be used immediately after unloading the same should be stored well covered with tarpaulin sheet. Other materials like spindle, nut bolt, gunny bag, hoist, hand wheel, etc. should be stored in safe place. HEALTH SAFETY AT WORKS NOTICE Attention is drawn to the duty for which the equipment in this manual was designed. The equipment must be installed operated and maintained in accordance with recommendations given by us and we disclaim responsibility if any relevant information or advice given is disregard and for using procedures other than those recommended. Web : www.yashwant.biz More Information: yiw.online@gmail.com 5 P a g e

The equipment must only be used for duties within the scope described with all accessories properly aligned, fixed and inter faced, but should it be necessary to consider alternative we would be pleased reference and items affected. INSTALLATION OF C.I/ M.S/ S.S/AL. SLUICE GATES The gates are manufactured with great care to insure accuracy in mating the faces of the door and frame. It is very essential therefore that the gates should be accurately erected, free from distortion and treated with the gates must not be dismantled for fixing. The gates assembly should be erected in concrete in the line with plumb than the gate should be placed the foundation bolts of gates frame should embedded into concrete. After the growth is cured check frame and gate plate faces for the non-acceptance of feeler gauge and pack or wedge if necessary between wall and frame. Carefully tighten each foundation bolt nut attending to opposing nuts in turns excessive tightness in not required. Clean operating hoist open fully and carefully remove all foreign matters from faces, wedging, sling surfaces and operating screw should than be well greased. Every care should be taken to ensure that the faces are neither scratched nor damaged. other wise the gates cannot be expected to seal under pressure. WEDGES OF SLUICE GASTES All wedges are perfectly set before dispatch. If there is leakage due to frame being twisted during erection this must be rectified before any wedges adjusted. The wedges on gate should be adjusted diametrically opposite each other commencing highest wedge on one side. Firstly fixing bolts should be loosened and then adjusting bolts should be unscrewed. Close the gates plates on matching face of frames. Tighten the adjusting bolts. Tighten the fixing bolts. Check with feeler gauge again. When the wedges are set the clearance should not exceed. GENEARAL MAINTANCE INSTRUCTIONS FOR SLUICE GATE Each gate should be inspected thoroughly after every six months. Spindles and other working components should be lubricated after every six months. Use of large diameter hand wheels should be avoided. The gates before regular use or after having been left standing for considerable length of time gate plate should be raised and foreign matter should be carefully removed. The contacting faces, spindles and other machined parts should be greased. Every possible care should be taken to ensure that the faces are neither scratched nor damaged. FIXING OF LIFTING RODS. STEM/ GUIDE BRACKETS After the gate has been mounted, the lower end of stem in the gate plate. Joint gates plate and spindle by nut-bolts. Web : www.yashwant.biz More Information: yiw.online@gmail.com 6 P a g e

Insert threaded stem into stem nut. Mount stem guide in order from the bottom up as stem is installed. Place the foundation bolts of stem guide and grout pocket. Check bolts projections are square. Place the nut on the foundation bolt. Do not tighten it immediately. Once concrete is set then tighten the nut to the requirement. Install stem couplings are required. Make sure to tighten all the bolts with nuts of the coupling. Take care, not to bend stems or damage threaded during installation. MOUNTING OF HEAD STOCK Place the headstock assembly and guide assembly on the platform insert the anchor foundation bolts for both the assemblies and grout the pockets. Check bolt projection are square. Place the nut on the anchor bolt. Do not tighten it immediately. Once concrete is set than tighten the nut to the requirement. The threaded end of the stem is already inserted in the stem nut. Fix the hand wheel on the work shaft of the headstock. DO S AND DONT S Before Sluice gate is put into regular service or after being left standing for considerable length of time the door should be raised and all foreign matter carefully removed from faces, guide grooves and the invert area. The sealing faces, guide wedge faces, screwed stems and any other machine part should then be well greased. Do not use large hand wheels, tee keys, other than those originally supplied. Every Sluice gate should be operated at least once every three months and checked for signs of wear / corrosion every six months. The nuts of all constructional and foundation bolts should be checked for tightness after every twelve months. On installations which are subjected to vibration due to high water velocity acting on the gate all bolts / mits should be checked more frequency for tightness. If the Sluice gates are installed in situation where debris or foreign matter can be built up, we recommend that the Sluice gate should be periodically inspected. The protection paint should be examined after every six months for signs of damage and be repainted as required. The screw of each gate should be cleaned inspected for wear and re-greased every six months. The grease nipples should be greased after every six months. The stem nut should be checked after every twelve months for signs of wear and replaced if necessary. Badly worm threads shearing and cause the gate to fail without warning. If frequency of operation is greater than this or operation condition, are more severe inspection should be carried out at shorter intervals to suit. When the stem protection cover is supplied these should be removed every six months and the stem cleaned inspected for wear and re-greased prior to refitting of the cover. Use of large diameter hand wheel should be avoided. The gates before regular use or after having been left standing for considerable length of time gate plate should be raised and foreign matters should be carefully removed. The contacting faces, spindles and other machined parts should be greased. Every possible care should be taken to ensure that the faces are neither scratched nor damaged. For YASHWANT INDUSTRIAL WORKS PVT.LTD. Web : www.yashwant.biz More Information: yiw.online@gmail.com 7 P a g e