PROFLAME G FIRE SYSTEM

Similar documents
R PROFLAME Instruction Book Collection

45 AND 60 UNIVERSAL REMOTE INSTALLATION AND OPERATION INSTRUCTIONS

Model: 5001 INSTALLATION AND OPERATING INSTRUCTIONS

Model: 5301P INSTALLATION AND OPERATION INSTRUCTIONS

Cat. No. H8861 Model: RCL-S-STAT

5001 INSTALLATION AND OPERATING INSTRUCTIONS

3301 INSTALLATION AND OPERATING INSTRUCTIONS

Model: 3003P INSTALLATION AND OPERATING INSTRUCTIONS

CAUTION. RXM5010 Touchscreen Remote Installation and Operation Manual MODEL: RXM5010

Model: 1001TH-A INSTALLATION AND OPERATING INSTRUCTIONS

Model: 5010 INSTALLATION AND OPERATING INSTRUCTIONS

f i r e - p a r t s. c o m

SMART-STAT Remote Control Kits - Installation and Operating Instructions -

Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS

1410T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS

Model: VR-1A INSTALLATION AND OPERATING INSTRUCTIONS

Model: 3301PF. Built-in Factory Program

Radio Control Installation and Operating Instructions System 4

Avanti Hearth Products Z60

Model: 3301PF-1 INSTALLATION AND OPERATING INSTRUCTIONS

3301PF INSTALLATION AND OPERATING INSTRUCTIONS

PHOTO FRAME STRING LIGHTBOXES

Installation & Programming Guide

Model: 4001TH INSTALLATION AND OPERATING INSTRUCTIONS

CON1001TH-1 (SKYCONTH-1) INSTALLATION AND OPERATING INSTRUCTIONS

Remote Control Outlets Operating Instructions

Model: VR-2A INSTALLATION AND OPERATING INSTRUCTIONS

Model: 3301P. Built-in Factory Program

TROUBLE SHOOTING FOR 1001-A SERIES REMOTES

MRT. Instruction Manual. Remote Crane Controls. PSMRTINST-01A October, 2001 Part Number: Copyright 2001 Electromotive Systems

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

RCTS-MLT Remote Control Kits -For use with SIT Millivolt Valves only- - Installation and Operating Instructions -

B-Tronic EasyControl EC5401B

See Page 8 for Part Numbers

KNX radio wall-transmitter 1gang/2gang flat quicklink Order no.: 8565 x2 xx

INSTALLATION INSTRUCTIONS ATV WINCH MULTI-MOUNT Multi-Mount Mounting-Kit: PN Application: YAMAHA BIGBEAR 00+

RCT-MLT-II Remote Control Kits - Installation and Operating Instructions -

Installation Instructions

2016 Motorized Shades Basic Programming

Radio / Cassette. Malta RCR 45. Operating instructions

Users instructions SYMAX remote for your Wanders fires & stoves gas appliance

GV60 PLUS. GV60 PLUS Electronic Ignition Remote Control. used on Valor heaters of Series Portrait, Horizon, H4, G3, L1, L2, L3, MF and RFD

ATOMIC WALL CLOCK with REMOTE TEMPERATURE SENSOR Model CL Instruction Manual

Installation Instructions

DEUTSCH. Operating instructions ENGLISH. Kiel RD 104

534I, 650, 739I, 1200, 1300, 1500, MF28I

New Radio Remote Control Switching System with LED Indicator Light in Remote Control

Radio controllers. Innovation combined with skill and tradition. Intelligent solutions. for all living spaces. Radio-controlled regulation

INDEX 1 - PRODUCT FEATURES

Splash-proof Wireless Stereo Speaker System User s Manual

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use.

ACCESSORY MODULE Including Protection, Performance, and Inlet Shut-off Valve Packages

RADIOBAND V3 Programming & Installation Manual

Operation. 1 of 14. Serial number label

CONTENTS. Accessories and Components System Unit and Joystick Assembly and Charging the Battery Jeotech Using Phases...

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

ERROR MESSAGES: Click on Error for further detail PROBE ERROR: PROBE IS OPEN OR NOT CONNECTED.

INSTALLATION INSTRUCTIONS UTV LIGHT BAR KIT Part Number: and Application: All UTV s*

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

BR2 Lap Beacon Manual

INSTALLATION INSTRUCTION ATV BUMPER/WINCH MOUNT Mount Kit: PN Application: POLARIS 300, 400, 500 and 700 Sportsman

Synthesized Transmitter

Wireless Rain Station

SMART TOILET CONTROL

Installation And Programming Instructions For Profile Series With RF Technology

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

MEGA REMOTE RADIO REMOTE CONTROL SYSTEM

C-Bus 8 Channel Low Voltage Relay

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

INSTRUCTION MANUAL VHF FM TRANSCEIVER TK-7102H UHF FM TRANSCEIVER TK-8102H KENWOOD CORPORATION B (M)

EPIC VOICE AMPLIFIER P/N SERIES FOR USE WITH SCOTT RESPIRATORS USING SCOTT FULL FACEPIECES EQUIPPED WITH VOICEMITTERS

«FCC» DECLARATION OF CONFORMITY FCC rules PART 15. NUM AXES declares that. the training collar DOGTEK CANICOM 400

SIT 849 SIGMA LH M U LT I F U N C T I O N A L C O N T R O L F O R G A S B U R N I N G A P P L I A N C E. w w w. s i t g r o u p.

PR-D9CL. GB Version 1

Receiver Type /Version Factory No. Frequency. Transmitter Type /Version Factory No. Frequency

Super Switch Indoor Wireless Remote Control Wall Outlets

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

V6889 IMPORTANT! KEEP INSTRUCTIONS FOR FUTURE REFERENCE. sher-price.com.au

OSMAC RDR Low-voltage Retrofit Kit

ENVIRONMENTAL PROTECTION

DM 800H Twin Handheld UHF System (863.0Mhz-865.0Mhz)

RF (RADIO FREQUENCY) WIRELESS PENDANT

Dynamo Brushless DC Motor and GreenDriveTM Manual

Mini Clamp Meter Model:

Wireless Rain and Wireless Rain/Freeze Sensor

2011 / Circuit Tracer

Section 7 Inteli-Touch Series Casablanca Fan Co. - Factory Service Department - Technical Library

4.Ebz!Gpsfdbtufs G U I D E n catio Lo

YARDMASTER 202S Training Collar System Operating Guide

This document is the property of Teleco Automation Srl who reserves all reproduction and copying rights

SMART TOILET CONTROL

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Activity 3: Wireless Communication Student Handout. Parts Descriptions. Wireless Communications: Wireless Burglar Alarm

Tel: Fax:

Acoustic Electric Guitar

High power radio transmission module MR03 type

3M Dynatel Far End Device III

Long-Range Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock Model: RMR183 & RMR183U User Manual

User Manual Digital Clamp Multimeter. model no.: MSR-C600

VIESMANN. Installation and service instructions VITOTROL 300 RF. for contractors. Vitotrol 300 RF

Transcription:

9.957.001 00 PROFLAME G FIRE SYSTEM USE AND INSTALLATION INSTRUCTIONS Read the instructions before use. This control must be installed in accordance with the rules in force.

English 2-8 The 584 Proflame G Fire is a modular remote control system that directs the many functions of today s hearth appliances. It is configured to control the on/off operation of the main burner. The Proflame G Fire is specifically developed to be used with multifunctional gas controls. 2

TECHNICAL DATA Remote Control Supply voltage Ambient temperature ratings Radio frequency 4.5 V (three 1.5 V AAA batteries) 0-60 C (32-140 F) 315 MHz Receiver Supply voltage Ambient temperature ratings Radio frequency 6.0 V (four 1.5 V AA batteries) 0-60 C (32-140 F) 315 MHz WARNING THE TRANSMITTER AND THE RECEIVER ARE RADIO FREQUENCY APPLIANCES. IF THE RECEIVER IS MOUNTED INSIDE METALLIC CASES, SEVERE LOSS OF PERFORMANCES ( REDUCTION OF THE RANGE OF WORKING) MAY RESULT. ATTENTION! - TURN OFF MAIN GAS SUPPLY OF THE APPLIANCE DURING INSTALLATION OR MAINTENANCE OF THE RECEIVER. - PLACE THE RECEIVER S 3 POSITION SLIDER SWITCH IN THE OFF POSITION DURING INSTALLATION OR MAINTENANCE. - TURN OFF MAIN GAS SUPPLY OF THE APPLIANCE PRIOR TO REMOVING OR REINSERTING THE BATTERIES IN THE RECEIVER. 3

SYSTEM DESCRIPTION The 584 PROFLAME G Fire System consists of two elements: 1. 584 PROFLAME G Fire Transmitter. 2. The 584 PROFLAME G Fire Receiver. The 584 PROFLAME G Fire System complements any millivolt Combination Gas Control. REMOTE CONTROL The Proflame Transmitter uses the latest digital technology, see Fig. 1. With the 584 PROFLAME G Fire Transmitter it is possible to turn the appliance on and off. The 584 PROFLAME G Fire Transmitter is the Remote Control that commands the Receiver. All the commands are given with one button: see Fig. 1. Moving the side slider in the direction of the transmission light it is also possible to disconnect the electric supply of the internal batteries (child safety feature). ON /OFF Key Transmission light Fig. 1: 584 PROFLAME G Fire Transmitter Side slider RECEIVER 4 The 584 PROFLAME G Receiver may be installed in a standard single gang wall switch box or in a low temperature area of the hearth appliance. The receiver accepts commands from the transmitter to operate the functions included with a particular Proflame system configuration. The receiver can be set to one of three positions: On (manual override), Command (remote control) or Off using the three position slider. When the switch is in the MANUAL position, an electrical circuit is created bypassing the transmittercontrolled contacts, and the appliance burner is turned ON. When the switch is in the REMOTE position the appliance is being controlled by the remote control system. When the switch is in the OFF position the appliance burner is turned OFF.

Installing the wall cover plate 1. Install the receiver in the J box using the existing J box screws. 2. Place the slider into the cover plate with the white dot on the right side. 3. Put the receiver switch in the OFF position. 4. Make sure the receiver and cover plate words ON are on the same side. 5. Align the slider with the switch on the receiver and couple the switch into the slider. 6. Align the screw holes. 7. Using the two (2) screws provided secure the cover plate to the receiver. 3 Positions Slider Fig. 2: 584 PROFLAME G Fire Receiver 2 PIN terminal Fig. 3: 584 PROFLAME G Fire Receiver batteries housing 5

INSTALLATION The 584 PROFLAME G Fire System is designed to command any millivolt Combination Gas Control. The wiring diagram of all the electrical connections is shown in Fig. 4. Particularly shown are three main elements of the system. The Receiver and 820 Nova mv Gas Valve can all be connected by single wire harness (not supplied). TH TP (+) (-) Red Black White Green TPTH Fig. 4: Wiring diagram. OPERATING PROCEDURE FUNCTIONALITY OF THE RECEIVER The Receiver is supplied by four (4) AA batteries, see Fig. 3. The receiver accepts commands via radio signal sent from the transmitter. The receiver sends commands by the wire harness to the multifunctional gas control. When the system is turned on, an acoustic signal ( beep ) is generated to indicate that the Receiver is ready to receive commands from the Remote Control. FUNCTIONALITY OF THE REMOTE CONTROL 6 When the batteries are installed into the Remote control and the side slider is in the position shown in Fig. 5, the LED on the transmitter illuminates each time the ON/OFF button is depressed.

ON /OFF Key Transmission light Fig. 5: 584 PROFLAME G Fire Transmitter Side slider COMMUNICATION BETWEEN THE REMOTE CONTROL AND THE RECEIVER To program the transmitter to the receiver, move the three positions slider of the receiver in the REMOTE position ( see Fig. 2 in page 5) and depress the ON/OFF key of the transmitter. The System has got an automatic learning mode that allows the receiver to mate with a new transmitter in the event that the transmitter must be replaced. As soon as the receiver receives the first correct command from any remote control it captures the new address and then "beeps" 3 times to confirm the synchronization and command execution. TURN ON THE APPLIANCE When the ON/OFF key is pressed, the LED on the transmitter illuminates and the Remote Control is switched on. At the same time the Receiver connects the thermopile to the gas valve millivolt coil and the appliance main burner turns on in the high position. An single acoustic signal from the Receiver confirms the reception of the command. TURN OFF THE APPLIANCE If the appliance and the Remote Control are switched on, when the ON/OFF key is pressed,the Remote control is turned off. At the same time the Receiver removes power from the gas valve millivolt coil and the appliance main burner turns off. An double acoustic signal from the Receiver confirms the reception of the command. LOW BATTERY DETECTION (Transmitter) The duration of the Remote Control batteries depends on many factors: the quality of the batteries used, the number of ignitions of the appliance, etc. When the transmitter batteries are low, depressing the ON/OFF key the light intensity of the LED (see Fig. 5) is weak to alert of a low battery condition before losing battery power at all. As soon as the depleted batteries are replaced, the Transmitter will restart its normal operation. LOW BATTERY DETECTION (RECEIVER) The duration of the Receiver batteries depends on many factors: the quality of the batteries used, the number of ignitions of the appliance, etc. 7

If the receiver batteries are low, a triple acoustic signal will be emitted by the receiver when it receives a command from the transmitter depressing the ON/OFF key. This is an alert of a low battery condition before losing battery power at all. As soon as the depleted batteries are replaced, the acoustic signal from the receiver confirms the reception of the ON/OFF command from the transmitter. CHILD SAFETY LOCK-OUT With this function it is possible to deactivate the remote control key, see Fig. 6. Child safety function OFF Child safety function ON Fig. 6: 584 PROFLAME G Fire Transmitter child safety function BACKUP FUNCTION If the batteries of the Receiver are low, the appliance can be switched on manually by moving the 3 position slider switch on the Receiver to the ON position, see Fig. 3 in Page 5. WARNINGS AND CAUTIONS WARNING Fire Hazard. Can cause severe injury or death The Receiver causes the ignition of the fireplace. The fireplace can turn on suddenly. Keep away from the burner, especially when operating on the BACKUP switch. CAUTION Property Damage Hazard. Excessive heat can cause property damage The fireplace can stay ignited for many hours. Take care to turn off the fireplace if it is unattended by adult people. Do not leave the Remote Control where children can reach it. 8