SETUP SUNSTAR 传感与控制 Model 3173 PERFORMANCE SPECIFICATIONS Load range 1 Accuracy 0.07 % Non-linearity Hysteresis Repeatabilit

Similar documents
Model Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Models Tension/Compression Pancake Load Cell Model 3174 with tension base DESCRIPTION FEATURES

Model UG. Ultra Precision Universal Canister Load Cell DESCRIPTION FEATURES

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

Model RGH. Rod End In-line Compression/Tension Load Cell DESCRIPTION FEATURES

Model RH. Rod End In-line Tension Load Cell DESCRIPTION FEATURES

Model A-5. Mid Range Wet/Wet Differential Pressure Transducer. A-5, Datenblatt Seite 1 DESCRIPTION FEATURES

TORQUE. Quick-ship program - torque

Hall-effect Position Sensors with Sealed Housing The 103SR Series Hall-effect position sensor assemblies are sealed in aluminum or stainless-steel thr

Model TMS DIN-Flange Torque Measurement System DESCRIPTION APPLICATIONS FEATURES

Model TS. Transducer Simulator User s Guide. Sensotec Sensors

Load Cells LOAD CELLS

WOI Series. Limitless Wireless Operator Interface DESCRIPTION

Quadrature Speed and Direction Sensors. SNG-Q Series. Datasheet

Model FP2000. Configurable Pressure Transducer DESCRIPTION FEATURES

Limitless Wireless Multi-Protocol Receiver WMPR Series Issue 2. Datasheet FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS

Load Cell Accessories and Services

Heavy Duty Pressure Transducers

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

SMART Position Sensor, 100 and 180 Arc Configurations

ZT-4 Tonnage Load Module By Toledo Integrated Systems User s Manual

Miniature pressure sensor

SS421 Series. Solid State Hall-effect Sensors Adjustable Hall-Effect Under-speed Detectors

Model LBS Miniature Compression Load Button

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

Characteristic Condition Min. Typ. Max. Unit. Response time 3 µs Output voltage swing: VOM- VOM+ 0.4 V s - 0.4

TRANSDUCER IN-LINE AMPLIFIER

Issue D. Installation Instructions for the Quadrature Speed and Direction Sensors SNG-Q Series. Sensing and Internet of Things

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

XPC10 High temperature miniature pressure sensor

Broadband Current Probe Series Operation Manual

Sensor Datasheet Collection

Model FP2000. Configurable Pressure Transducer DESCRIPTION FEATURES

up to 200 C, 4007B... Technical Data 4007B, General Measuring range bar Overload bar Power supply ma* 1 Output signal (FS

Model DB Disc Caliper Brake AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

HOD /BBA HOD /BBA

Non-Submersible Industrial Pressure Transducer

Model A. DIN Rail Strain Gage Conditioner. Installation and Operating Manual

SUNSTAR 传感与控制

PX2 Series Heavy Duty Pressure Transducer

TRANSDUCER IN-LINE AMPLIFIER

Model 935A Current Source Operation Manual

MICRO SWITCH Electromechanical Safety Switches GSS Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

PX2 Series Heavy Duty Pressure Transducer

Model C STRAIN GAGE LOAD CELL. Installation and Operating Manual

Application Sheet How to Apply Honeywell APS00B Angular Position Sensor ICs

Broadband Current Probe Series Operation Manual

Type N Coaxial Calibration Kit

HOD /BBA HOD /BBA

Series APD4059. For Load Cells/Pressure Transducer Transmitters. Field Rangeable, with Calibration Resistor. Standard Features.

Glass Electrode Meter

TRIAXIAL FLUXGATE MAGNETOMETER OWNER'S MANUAL

Bipolar, Latching, or Unipolar Digital Hall-effect Sensor ICs: SS400 Series, SS500 Series

Specifications Type WA2 WA10 WA20 WA50 WA100 WA200 WA300 WA500 Nominal displacement mm Nomi

Holz-Her Sliding Table Saw Kit Installation Instructions: For 1243 Cross-Cut Kits 2 DRO Retrofit

ELPF Load Cell DESCRIPTION

USER GUIDE. WR284 Waveguide TRL Calibration Kit GHz. Models: WR284C30\32 Series (Rev A) 03/16

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

Model 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R

Tension Control Clutch Model TCC-7

9320 Manual Portable Battery Powered Indicator

Telescopic Screw Gun Bracket & Accessories

AM95 Installation Guide

125 Mbps, 650 nm LED. Dimensions

Disc Caliper Brake Model DBSE

English FULL MOTION FLAT PANEL TV MOUNT. User Manual L102 TV Mount. 56 lb (25 kg) VESA. Supporting your digital lifestyle (

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

ULT-DIN O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

bar, Type 413xA..., 414xA... Technical Data (based on Tref = 25 C; power supply 1 ma constant) Type 413xA... 0,2... 0,

CAUTION: WEIGHT ON THIS PRODUCT SHOULD NOT EXCEED 136KG / 300LBS.

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Angular Rate Sensor. Owner's Manual

Installation Instructions for the Transportation Attitude Reference System (TARS Series) Ruggedized Inertial Measurement Unit (IMU)

Current Probe Fixture Instruction Manual

Torque Sensor Accessories and Services

200Amp AC Clamp Meter + NCV Model MA250

o-ring grease can be used to hold the o-ring in the groove during installation.

INSTALLATION INSTRUCTIONS for INSIGHT FIBER OPTIC FLAME SCANNERS

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

Model A. Reaction Torque Sensor. Installation and Operating Manual

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Analog Voltage Detector 0-40kV Operating Instructions VDA040CTM

Model FP2000. Configurable Pressure Transducer DESCRIPTION FEATURES

Questions? Call Toll-Free

Pre-wired Photomicrosensor with Amplifier and Cable EE-SPW321/421 Compact, Thin-profile Photomicrosensor with special amplifier.

USER GUIDE 2.92mm Coaxial Calibration Kit

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Limitless Wireless Multi-Protocol Receiver. WMPR Series. Datasheet

TL-W5MD1 2M *1 *3 TL-W5MD2 2M

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

Heavy Duty Pressure Transducers. PX2 Series 1 bar to 46 bar 100 kpa to 4.6 MPa 15 psi to 667 psi. Datasheet

INSTRUCTION BOOK AND PARTS LIST

Distribution Amplifiers 1

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

INSTALLATION MANUAL SONANCE SOUNDBARS SB46 M AND SB46 L. Introduction. Box Contents. Wall Mount Installations

KURT D810 AngLock Vise Base Assembly

Swivel Hoist Ring RIGGING ACCESSORIES. Color coded to distinguish between UNC (Red) and Metric (Silver) thread types.

SAS-563B Active Loop Antenna Operation Manual

Instruction Sheet SNE SERIES. Cable Chase

Transcription:

Model 3173 DESCRIPTION The Model 3173 covers the lower capacity ranges of 200 pounds force to 3000 pounds force, while exhibiting the high performance characteristics of stiffness and accuracy. These load cells are well suited to materials testing machines and other applications requiring a rugged load sensor. Often ideal for high cycle count applications. FEATURES English threads Enhanced accuracy, 0.07 % Low deflection Fatigue-resistant design and enhanced performance Low full-scale capacity Low profile Decreased sensitivity to extraneous loading m

SETUP SUNSTAR 传感与控制 http://www.sensor-ic.com/ Model 3173 PERFORMANCE SPECIFICATIONS Load range 1 Accuracy 0.07 % Non-linearity Hysteresis Repeatability Output @ rated capacity (200 lb to 1K lb) Output @ rated capacity (2K lb to 3K lb) Operation Resolution 200, 500, 1K, 2K, 3K lb ±0.05 % of rated output ±0.05 % of rated output ±0.02 % of rated output 1.50 mv/v (nominal) 2.00 mv/v (nominal) Tension/compression Infinite Standard calibration Tension (+) and compression (-) ENVIRONMENTAL SPECIFICATIONS Temperature, operating Temperature, compensated Temperature effect, zero Temperature effect, output ELECTRICAL SPECIFICATIONS Strain gage type Excitation (maximum) Insulation resistance Input resistance Output resistance -54 C to 93 C [-65 F to 200 F] 21 C to 77 C [70 F to 170 F] ±0.002 % of rated output/ F ±0.002 % of reading/ F Foil 20 Vdc or Vac RMS > 5000 mohm @ 50 Vdc 700 ohm 700 ohm Zero balance ±1.0 % Electrical termination PT02E-10-6P MECHANICAL SPECIFICATIONS Static overload capacity Material Fatigue life (0 to full fatigue load) Fatigue life (full fatigue tension to compression) Natural frequency 150 % of nominal capacity Carbon steel 100 x 10 6 cycles 50 x 10 6 cycles See table WIRING CODES Cable Red Black Green White (+) excitation (-) excitation (+) output (-) output TYPICAL SYSTEM DIAGRAM In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV +/-5 VDC UV-10 +/-10 VDC UBP 0 +/-5 VDC U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV-05 0 +/- 5 VDC (3 wire) DA-05 4-20mA (3 wire) DV10 0 +/- 10 VDC (3 wire) Recommended Tension Base 064-LW31684-1 MODEL 3173 In-Line Amplifier Output Serial Number Mating Connectors & Cables Input Display Units Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH 7541 7558 7561-PSD 2003.1 lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT 023-LW181-023-LF Mating Connector 7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) 7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) 7205-83-XX* Mating connector & 6 conductor cable 7205-82-XX** Mating connector & 4 conductor cable OR * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum 2 SUNSTAR Sensing and 自动化 http://www.sensor-ic.com/ Control m

NATURAL FREQUENCY Nominal load limit capacity F z Static extraneous load limits lb N Static overload capacity (% of nominal capacity) Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) Ringing frequency (Hz) 200 1K 150 100 4471 185 0.003 1500 500 2K 150 100 15625 466 0.003 2440 1K 5K 150 100 15500 911 0.003 3900 2K 10K 150 100 4000 2133 0.001 5500 3K 15K 150 100 5166 2818 0.001 7200 MOUNTING DIMENSIONS Model Capacity N [lb] A cm B cm C cm D cm E cm F cm G threads English H cm I cm No. of holes J Bolting screws K L cm M cm N cm O cm P cm Q cm 3173 900-13.5K [200-3K] 10,47 [4.12] 7,24 [2.85] 3,23 [1.27] 3,48 [1.37] 0,31 [0.12] 0,15 [0.06] 5/8-18 UNF-3B 8.89 [3.5] 0,71 [0.28] 8 1/4-28 hexhead* 3,18 [1.25] 1,27 [0.50] 0,08 [0.03] 2,87 [1.13] 2,21 [0.87] 0,64 [0.25] * tighten to 200 in-lbs m Sensing and Control 3

Model 3173 NOTES 1. This unit calibrated to Imperial (non-metric) units. Warranty. warrants goods of its manufacture as being free of defective materials and faulty workmanship. s standard product warranty applies unless agreed to otherwise by in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to during the period of coverage, will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions 1985 Douglas Drive North Golden Valley, MN 55422 USA 008618-1-EN IL50 GLO May 2008 Copyright 2008 International Inc. All rights reserved. +1-815-235-6847 www.honeywell.com/sensing m

Models 3174-3176 Model 3174 Model 3174 with tension base DESCRIPTION Models 3174, 3175, and 3176 are fatigue-resistant, low-profile tension and compression load cells that are well suited to materials testing machines and other applications requiring a rugged load sensor, while exhibiting the high performance characteristics of stiffness and accuracy. These load cells are extremely resistant to extraneous bending and side-loading forces. The structure virtually eliminates bending strains at the strain gage, minimizing the primary cause of load cell failures. FEATURES English threads Enhanced accuracy, up to 0.07 % Low deflection Fatigue-resistant design and enhanced performance Tension/compression capacity Low profile Low sensitivity to extraneous loading m

SETUP SUNSTAR 传感与控制 http://www.sensor-ic.com/ Model 3174-3176 PERFORMANCE SPECIFICATIONS Load range 1 Non-linearity Hysteresis Repeatability Output @ rated capacity Creep Resolution 5K, 10K, 20K, 50K, 100K lb ±0.05 % of rated output ±0.05 % of rated output ±0.02 % of rated output 2.00 mv/v (nominal) ±0.025 % of rated output Infinite Standard calibration Tension (+) and compression (-) ENVIRONMENTAL SPECIFICATIONS Temperature, operating Temperature, compensated Temperature effect, zero Temperature effect, output ELECTRICAL SPECIFICATIONS Strain gage type Excitation (maximum) Insulation resistance Bridge resistance Number of bridges 1-54 C to 93 C [-65 F to 200 F] 21 C to 77 C [70 F to 170 F] ±0.002 % of rated output/ F ±0.002 % of reading/ F Foil 20 Vdc or Vac RMS > 5000 mohm @ 50 Vdc 700 ohm Zero balance ±1.0 % Electrical termination PT02E-10-6P MECHANICAL SPECIFICATIONS Static overload capacity Material Fatigue life (0 to full fatigue load) Fatigue life (full fatigue tension to compression) Natural frequency 150 % of nominal capacity Carbon steel 100 x 10 6 cycles 50 x 10 6 cycles See table WIRING CODES Cable Red Black Green White (+) excitation (-) excitation (+) output (-) output TYPICAL SYSTEM DIAGRAM In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV ±5 Vdc UV-10 ±10 Vdc UBP 0 ±5 Vdc U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV-05 0 ±5 Vdc (3 wire) DA-05 4-20mA (3 wire) DV10 0 ±10 Vdc (3 wire) Recommended Tension Base 064-LW30774-1 MODEL 3174 Output In-Line Amplifier Serial Number Input Display Units Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC UP Power Supply SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH 7541 7558 7561-PSD Mating Connectors & Cables 2003.1 lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE 023-LW181-023-LF Mating Connector 7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) 7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) 7205-83-XX* Mating connector & 6 conductor cable 7205-82-XX** Mating connector & 4 conductor cable OR * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum DOWN ENTER EXIT 2 SUNSTAR Sensing and 自动化 http://www.sensor-ic.com/ Control m

SETUP SETUP SUNSTAR 传感与控制 http://www.sensor-ic.com/ NATURAL FREQUENCY Nominal load limit capacity F z Model lb N Static overload capacity (% of nominal capacity) Fatigue capacity (% of nominal capacity) Static extraneous load limits Shear F X or F Y (lb) Bending M X or M Y (lb-in) Torque M Z (lb-in) Deflection at nominal load limit (in) Ringing frequency (Hz) 3174 5K 20K 150 100 11K 9K 12K 0.001 6500 3174 10K 50K 150 100 25K 27K 24K 0.001 7200 3174 20K 100K 150 100 55K 58K 35K 0.001 8600 3175 50K 200K 150 100 32K 33K 67K 0.001 12000 3176 100K 500K 150 100 78K 147K 196K 0.001 15000 TYPICAL SYSTEM DIAGRAM TYPICAL SYSTEM DIAGRAM In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV ±5 Vdc UV-10 ±10 Vdc UBP 0 ±5 Vdc U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV-05 0 ±5 Vdc (3 wire) DA-05 4-20mA (3 wire) DV10 0 ±10 Vdc (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply In-Line Amplifiers (Used with unamplified units only) Amplifier Output Universal In-Line Amplifiers UV ±5 Vdc UV-10 ±10 Vdc UBP 0 ±5 Vdc U3W 4-20mA (3 wire) U2W 4-20mA (2 wire) DIN rail Mount In-Line Amplifiers DV-05 0 ±5 Vdc (3 wire) DA-05 4-20mA (3 wire) DV10 0 ±10 Vdc (3 wire) Customer Supplied Chart Recorder Alarm Panel Data Acquisition Computer PLC Power Supply In-Line Amplifier Output Serial Number Input In-Line Amplifier Output Input Serial Number Recommended Tension Base 064-LW31496-1 MODEL 3175 Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH 7541 7558 7561-PSD Recommended Tension Base 064-LW31496-2 MODEL 3176 Display Units SC500 SC1000 SC2000 SC2001 SC3004 GM NK HH 7541 7558 7561-PSD OR UP 2003.1 lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE DOWN ENTER EXIT OR 2003.1 lb. L1 L2 L3 L4 VALUE CLEAR CHAN TARE UP DOWN ENTER EXIT Mating Connectors & Cables 023-LW181-023-LF Mating Connector 7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) 7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) 7205-83-XX* Mating connector & 6 conductor cable 7205-82-XX** Mating connector & 4 conductor cable * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum Mating Connectors & Cables 023-LW181-023-LF Mating Connector 7205-76-XX* Mating connector & 6 conductor cable (unamplified unit with sense leads but not shunt cal) 7205-75-XX** Mating connector & 4 conductor cable (unamplified unit without sense leads but not shunt cal) 7205-83-XX* Mating connector & 6 conductor cable 7205-82-XX** Mating connector & 4 conductor cable * XX represents length in feet 100ft maximum ** XX represents length in feet 20ft maximum m Sensing and Control 3

Model 3174-3176 MOUNTING DIMENSIONS Model Capacity N [lb] A cm B cm C cm D cm E cm F cm G cm H cm Tap thru I English J cm K cm No. of holes L Bolting M English 3174 20K- 100K [5K- 20K] 15,39 [6.06] 10,99 [4.33] 6,35 [2.42] 4,45 [1.75] 0,310 [0.12] 0,13 [0.05] 5,72 [2.25] 2,06 [0.81] 1¼-12 UNF-3B 13,02 [5.13] 10,3 [13/32] 12 3/8-24 hex head, 2¼ inches long, tighten to 750 in-lb 3175 200K [50K] 20,32 [8.00] 13,15 [5.18] 7,98 [3.14] 6,35 [2.50] 0,30 [0.12] 0,08 [0.03] 7,98 [3.14] n/a 1¾-12 UN-3B 16,51 [6.50] 13,50 [17/32] 16 ½-20 hex head, 3 3/8 in long, tighten to 120 ft-lb, grade 8 bolts 3176 500K [100K] 27,94 [11.00] 18,02 [7.09] 12,50 [4.92] 8,89 [3.50] 0,30 [0.12] 0,08 [0.03] 12,50 [4.92] n/a 2¾-8 UN- 3B 22,86 [9.00] 16,70 [21/32] 16 5/8-18 hex head, 4 5/8 in long, tighten to 290 ft-lb, grade 8 bolts * tighten to 200 in-lbs RECEP. PT02E-10-6P (MATING CONNECTOR FURNISHED) J BOLT CIRCLE THIS SURFACE FLAT TO 0.0005 INCH TIR AND FINISH TO 64 MAX 16 45 MODEL 3174 ONLY A G 2.25 INCH 5.12 CM E I TAP THRU C DIA. K DIA. THRU L NUMBER OF HOLES EQUALLY SPACED M RECOMMENDED BOLTING SCREWS I TAP THRU H D F D Tension bases are recommended for all model 3174, 3175 and 3176 applications. When mounting without the tension base, attention must be given to the mating surface with regard to flatness, hardness and stiffness. F B DIA. A DIA. 4 SUNSTAR Sensing and 自动化 http://www.sensor-ic.com/ Control m

Model 3174-3176 NOTES 1. This unit calibrated to Imperial (non-metric) units. Warranty. warrants goods of its manufacture as being free of defective materials and faulty workmanship. s standard product warranty applies unless agreed to otherwise by in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to during the period of coverage, will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions 1985 Douglas Drive North Golden Valley, MN 55422 USA 008619-1-EN IL50 GLO May 2008 Copyright 2008 International Inc. All rights reserved. +1-815-235-6847 www.honeywell.com/sensing m