ES8000-S V-LOCK ELECTRICAL SPECIFICATION INSTALLATION INSTRUCTIONS

Similar documents
FSH. ility VE1260 V

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

Travel Trailer Latch With Dead Bolt Trailer Latch With Dead Bolt. U.S. Patent No. 5,927,773

Replacement PVCu Door Lock

Installation & Programming Guide

WD WD7000 Series

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

Installing Your Electronic Deadbolt

CRCODE-202. Mechanical Lock. Instruction and Programming Manual. Before Installing:

Before fitting door, check opening size and squareness of timber frame. The door is made smaller to give correct clearance within the frame.

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

Product data sheet R106FS POWERMATIC FREE SWING DOOR CLOSER

Entry Mortise Lock Set Lever to Lever

Installation Instructions

Installers guide Deadbolt 02.

INSTALLATION MANUAL FORTRESS SERIES

Door Hardware Installation Instructions. For Assistance Call:

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

Ovation Series Door Furniture. ASSA ABLOY, the global leader in door opening solutions

Pet Door Panel Installation Manual

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

Installation Instructions for Trilock Omni BB Twin Pull Handle Version - Suits 35mm to 45mm door thickness

Window Locks. We take the worry out of protecting what s valuable to you. Lockwood: no worries.

Tools Required. * When installing on a fire door, please see instructions below. *

MORTISE LOCKS LA1Tx7 //DATASHEET

Passage Mortise Lock Set Lever to Lever

FOLDING DOOR INSTRUCTIONS

Screen Door Locks. Mechanical Locking Solutions. Window Locks. Lockwood Product Catalogue 1300 LOCK UP ( ) lockweb.com.au 2.

CL4500 Installation Instructions

INSTALLATION INSTRUCTIONS Z7800 SERIES MORTISE LOCK

Installation Instructions

Installation Instructions 50 (06-09) 1-15/32 15/32 21/32. 1/4-20 x 5/8" FHMS or #14 x 1/2" FHWS 1/16 1/4. Floor Plate

Installation Instructions

Installation Instructions. Oakmont Folding Doors

Entry Mortise Handleset

Installation Instructions For The 8850FL Series Mortise eboss

Mounting a BalanceBox 400 to a brick wall

Shetland Stalls Installation Instructions

WOOD DOOR INSTALLATION

Sectional Door Installation Instructions

ED5200S(A) Series ED5200S(A) Series x M107 Windstorm Series SecureBolt Exit Device

CrossOver X25 Lock Installation Need another copy of these installation sheets? You can download one at

P USHbutton 500 series

2. Connect driver to power source leads. After connections are made, place driver above ceiling. SEE MINIMUM SPACE REQUIREMENTS BELOW.

98/ Customer Service # Dogging Key (use to lock down pushbar)

SIMPLICITY SERIES. Affordable hardware for multi-residential developments made easy.

INSTALLATION INSTRUCTIONS

Stage 2: Preparing the door (read in conjunction with Hole Drilling Options on back of Template).

Parts. Backplate. Battery Cover. Backup Key. Touchscreen Assembly. Inside Assembly. Thumbturn. Strike. Reinforcement Plate. Bolt.

ED5200(A) Series Rim Exit Devices

XL JOINERY LTD LA PORTE VISTA MODULAR 3 ASSEMBLY INSTRUCTIONS

Installation Instructions

KNOB LATCH. Specifications: Glass-To-Wall Installation CAT NO. LAT001 C.R. LAURENCE CO., INC. PROFESSIONAL QUALITY

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index:

Installation Instructions II-2/4/5K-0608

Catalogue. Locks for aluminium. The global leader in door opening solutions

33/3550AWDC. Fire-Rated Devices include these. additional. components. 1-Point Latch (LBL) Metal Edge Wrap required for 60 and 90-minute applications

7210 Surface Vertical Rod Exit Device Installation Instructions. Outside Trim

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

Required Tools: Suggested Additional Tools: 1 Cordless Drill with Robertson Bits 1 Ratchet Wrench 1 7/16 or 11mm socket 1 7/16 or 11mm Gear Wrench

Installation Instructions for Vista Air Vertically Folding Walls

How To Measure Your Finished Opening

SYSTEM 42 SCREEN CASSETTE WITH 30mm SIDE RAIL

CM340B STOP READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING SERVER CABINET FROM SKID

Vanity Installation Instructions

CRL JACKSON 900 SERIES

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

Installation instructions for the Apex and Volt Electric Locksets

ProLogic Xtreme L22 - Electromechanical Redundant Safe Lock System - Instructions

1530(F) Mortise Exit Devices Installation Instructions

Super Tube Spiral Slide Instructions

Shepherd 210A Fingerprint Door Lock Installation Manual V1.1

120x165mm. 85x165mm TEMPLATE. ELECTRONIC DEADBOLT model no.: & & Toll-free Number:

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

7130(F) Series Mortise Exit Devices Installation Instructions

INFITTING & OVERLAP HINGED DOORS

Installation Instructions

Acoustical Surfaces, Inc.

* * 9875/ Customer Service #10-24 # Dogging Key (use to lock down pushbar)

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

INSTALLATION: D1-NOTCH DRYWALL TRIM FLANGE

SERVICE MANUAL FOR HOMELOCK M1034D 2034D 1134DW 1134D

LEGENDS RETRACTABLE DOOR SCREENS

Lumber Smith. Assembly Manual. If you are having problems assembling the saw and need assistance, please contact us at:

Heavy Wall Applied Stop Tube Frame and Door Installation

INSTALLATION INSTRUCTIONS Small Flat Panel Height-Adjustable, Extended Pitch Swing Arm Wall Mount Model KWE-110

Installation Instructions

Using the RhAT II Universal

INSTRUCTION BOOK EASILY REMOVEABLE DIES FOR YOUR BINDING NEEDS OD 4012 SHOWN WITH THE OPTIONAL PALM SWITCH FOR THE OD 4012

Rim-Lock Door Set Installation Instructions

CM543 STOP READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE REMOVING CABINET FROM SKID

SERIES. Installation Instructions

HIT-30 ALUMINUM DOOR SERIES OWNERS MANUAL

LEGENDS RETRACTABLE DOOR SCREENS

SPIDA SAW OPERATIONS MANUAL

Transcription:

ES8000-S V-LOCK Part No. ES8000-221 - 1116 INSTALLATION INSTRUCTIONS IMPORTANT Please read the instructions carefully prior to installation. It is important to follow the instructions precisely to ensure the lock and strike plate are correctly positioned. ELECTRICAL PREPARATION Always ensure the correct transformer and cable gauge is specified and used. ELECTRICAL SPECIFICATION Power To Open (PTO) Wiring Connections BLACK BLUE - 0 volts d.c. - Access Control (PTO) RED - Positive Continuous Supply PURPLE - (COM) WHITE - (NO) ORANGE - (NC) NC NO DC Power + Bolt Position Monitor Power To Lock (PTL) Wiring Connections BLACK - 0 volts d.c. BLUE - Access Control (PTL) RED - Positive Continuous Supply NC NO PURPLE - (COM) WHITE - (NO) DC Power + Connections - 3 Wire Control: Positive voltage should be connected to the RED wire providing permanent power. Negative voltage should be connected to the BLACK wire. Positive voltage should be connected to the BLUE wire providing a lock/unlock signal. When connected as above the motor will provide power assisted unlocking allowing the bolt to retract with up to 15kg of side load. ORANGE - (NC) Voltage-free changeover switch contacts are provided for position monitoring. When locked, the monitor switch (COM-PURPLE) is connected to (NC-ORANGE). The V-Lock is multi-voltage and operates with either 12 to 24VDC power. The V-Lock has built-in Reverse Polarity Protection for installer safety. Note: We only recommend 3 wire connections at all times. Electrical Specifications Voltage Supply +/-5% 12Vdc@1000mA +/-5% 24Vdc@5000mA Peak Current Draw 1000mA Standard Current Draw (Locked) PTL 78mA PTO 130mA Lock Monitor Output Voltage free contacts rated 30Vdc/100mA Operation temperature -10 - +50 @90%RH

CABLE GAUGE REQUIREMENTS Distance Cross Cable Dimension Americal Wire Gauge 5m 0.33mm AWG22 10m 0.65mm AWG19 15m 1.04mm AWG17 20m 1.31mm AWG16 30m 1.63mm AWG14 50m 2.05mm AWG12 MOUNTING APPLICATIONS The V-Lock can be installed vertically or horizontally, however when used on entry doors exposed to weather, the V-Lock must never be installed vertically. Never mount the V-Lock in the floor. SELECTING THE MODE CONFIGURATION STEP A - Loosen both screws on side of lock body. - With some force, slide screws in direction required until stop at end of slot is reached. - Hold in position and re-tighten screws. PTL STEP B - Rotate Latch Plate screw beneath the red re-sealable sticker according to orientation shown below: Turn counter-clockwise 180 for Power-to-Open (Fail Secure) Turn clockwise180 for Power-to-Lock (Fail Safe) PTO STEP C - Change jumper position on Printed Circuit Board beneath the red re-sealable sticker as shown below: Power-to-Open (Fail Secure) Power-to-Lock (Fail Safe) Bolt Label IMPORTANT - Ensure the correct mode is set before applying power, then follow steps A-C. If the lock had been operated previously and the screw in Step B is missing refer to the Troubleshooting section. Ensure all re-sealable stickers and screws are re-attached after configuration to prevent ingress of dust.

DOOR PREPARATION FOR STRIKE AND JAMB Line 2 FRAM 8.0 3.0 1-2mm 2 DOOR When determining the location of the strike and the lock, always ensure the door seal is not overcompressed against the door jamb. Mark Line 1 corresponding to mid-plane of door (ensure there is no over compression between door and frame) Mark Line 2 corresponding with Line 1 on the door jamb Note: the centreline of the door (Line 1) should align with the centre of the V-Lock (Line 2) when the door is in the closed position.

V-LOCK CUTOUT Mark cut-out of V-Lock symmetrically about Line A. Cutout size of face plate must be 256mm x 30mm. Prepare door jamb appropriately as shown above. Note: Thickness of face plate - 3mm.

DOOR PREPARATION AND INSTALLATION OF STRIKE PLATE On the door, mark Line 3 corresponding to the top edge of the lock faceplate (Step 3). Mark and recess cutout of strike plate on door symmetrically, using Line B as the centre guide and Line 3 as the height guide. Cut out the 22mm wide and 23mm deep cavity for the bolt as shown above. Install the strike plate on the door, ensure the door gap is not more than 8mm between the strike plate and the faceplate on the V-Lock. Ensure strike plate is securely fastened to increase overall holding force and security of installation. Note: Thickness of strike plate - 3mm.

INSTALLING V-LOCK IN DOOR JAMB Ensure all wiring connections are correct and are insulated, make sure the wires do not rub on any sharp edges or do not interfere with any locking mechanism. Install the V-Lock into the door jamb as shown above. Power up lock, then let the door open and close normally with door closer. When the strike plate magnet comes within locking range, the V-Lock will lock automatically. IMPORTANT NOTE: Upon testing the V-Lock for the first time, listen if the motor strains. If there is any sort of strain, check if the strike plate and the lock body is aligned as per line 3 in Step 4. (you may be over compressing the door against the jamb/ frame) Adjust the strike or the lock accordingly

TROUBLE SHOOTING Q: The Door is closed but the bolt has not automatically extended and locked into the strike plate. A: Check the following in no particular order: - Check the gap between strike and faceplate is between 3-8mm. - Check the Power supply and Cable Gauge used is to required specification. - Check that its connected according to PTL or PTO requirements. - Check that its the correct strike plate used that came with the product. Q: I m trying to change the lock from Fail Safe PTL to Fail Secure (PTO). The screw in Step B is missing. A: If lock had been operated previously, the screw in Step B will not be visiable. In order to return the V-Lock back into post manufactured mode follow these steps; 1. Change the jumper setting to PTL mode. 2. Shift the top two screws to PTL mode. 3. Ensure the face plate magnet is aligned with the sensor at all times during this procedure. 4. Apply permanent negative voltage to the lock (Black wire) 5. Connect the Red and Blue wire together and apply (positive) power to these two terminals. (CONTINUE HOLDING IT IN THIS POSITION). 6. The bolt will move, watch the cavity indicated in Step B, CONTINUE HOLDING CONNECTIONS IN THIS POSITION. The screw will be visible, quickly remove all power. 7. Now that the screw is visible as shown in Step B you can rotate the screw. Note: Retry if screw is not totally accessible. Q: When the lock attempts to lock it does not lock and return back into the body. A: Check if the Power supply and Cable Gauge, is to required specification as per Page 1. Check that the strike plate and the lock body is aligned as per line 3 in Step 4. Q: When the lock attempts to unlock it does not retract all the way. A: Check that the cavity is wide enough and there is not any pressure on the lock body. Other items to check: - Check that 1000mA power supply is used - Check that the cable gauge is sufficient between the power supply and the lockas per Page 2 - Check that there is no mechanical interference, thats causing strain on the bolt.

ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience. ASSA ABLOY is represented in all major regions, in both mature and emerging markets, with leading positions in Australia, Europe and North America. As the world s leading lock group, ASSA ABLOY offers a more complete product range of door opening solutions than any other company on the market. 1300 LOCK UP (1300 562 587) lockweb.com.au ASSA ABLOY Australia Pty Limited, 235 Huntingdale Rd, Oakleigh, VIC 3166 ABN 90 086 451 9907 2016 The global leader in door opening solutions