967 269 Plan 798 Elevation 100 626 Section BC101ES DOLPHIN TITAN CHANGING UNIT Carrying capacity of more than 400kg An alternative design embodying strength, safety and hygiene in a robust construction HEIGHT 967 MM WIDTH 788 MM PROJECTION CLOSED 105 MM PROJECTION OPEN 626 MM Ideal for use in public toilets, washrooms or any area particularly vulnerable to vandalism Safety strap operable with one hand Aluminium Unit with rounded edges and stainless steel cappings Optional liner roll dispenser above the table Pneumatic shock absorbers concealed in strong stainless steel mount casings Pneumatic shock absorbers, facilitating smooth and noiseless operation PRODUCT CODES Linen roll dispenser BC101-PRD Paper rolls BC101-PR Offers your customers a unique service and optimum safety Hygienic and a customer-friendly solution TECHNICAL HELPLINE 01424 202224 DOLPHINSOLUTIONS.CO.UK
BC 101-ES Dolphin Prestige Titan Changing Unit and Liner Roll Dispenser User Manual Please read carefully before use DOLPHIN
INSTALLATION INSTRUCTIONS SAFETY BABY CHANGING TABLE Read the Installation Instructions Thoroughly Before Commencing Installation The design of the safety baby changing table makes it easy to mount in even very small rooms. The changing table must be mounted onto a wall which is suited to carry the weight of the table as well as a baby preferably a solid wall! Where To Mount the Baby Changing Table Determine the ideal place to mount the baby changing table. Keep in mind that the depth of the changing table is 625 mm in open position. The distance from the floor to the lower edge of the table mountings should be approx. 750 mm (see FIG. 1). Doorways, sinks etc. should of course also be taken into consideration when choosing where to mount the changing table. IMPORTANT: Do NOT mount the table in a chlorine-containing environment! Marking and Drilling Holes To mount the changing table onto brick, gas concrete or the like, use 10 mm screws and matching universal plastic dowels e.g. Fischer fixings type S-12. When mounting the changing table onto a cavity wall of min. 16 mm (or 2 x 13 mm) plaster board, we recommend prior mounting of a reinforcement plate of stainless steel, plywood or the like, onto which the changing table is subsequently mounted. Attach reinforcement plate to the wall using a considerable number of special metal cavity fixings, Fischer part. no. BC 62328 or equivalent (part. no. BC 62315 for double plate). The changing table itself is also mounted with these screws and dowels plus one metal washer per screw hole. For further details, please refer to the instructions of the dowel supplier. In places where plaster walls have not yet been finished, we suggest mounting a 16 mm plywood board on the inside of the plaster wall, rendering the need for a reinforcement plate on the outside unnecessary. Mark and drill holes as indicated on FIG. 1. The top holes for the table mountings should be drilled into solid brick - not into a joint. IMPORTANT: Be sure to drill the holes for the mountings exactly vertically underneath each other, or the pneumatic shock absorbers inside the mountings may break! BC 101-ES User Manual www.dolphindispensers.co.uk
PAPER ROLL HOLDER CHANGING TABLE The dimensions stated are based on a work height of approx. 950 mm. FIG. 1 MOUNTING THE BABY CHANGING TABLE Disassemble the cover plates of the table mountings by removing the 6 screws (3 on each) with a Torx screwdriver no. 20. Mount the table onto the wall, making sure that it is completely level. The changing table is factory pre-adjusted to easily close when given a slight push from open position. Check that the changing table is mounted solidly onto the wall. Check that the shock absorbers can pass freely when opening and closing the table. Reassemble the cover plates onto the mountings. BC 101-ES User Manual www.dolphindispensers.co.uk
Components MOUNTING PAPER HOLDER The paper holder consists of the following parts: 1 holder Left-side mountings with lock Right-side mountings 2 keys Mark and drill holes as indicated on FIG. 1. Fix the mountings onto the wall with 6 mm screws and plugs suited for the wall type onto which the paper holder is to be mounted. Place a paper roll loosely in the paper holder and tip the holder towards the wall, making the white locking devices click. BC 101-ES User Manual www.dolphindispensers.co.uk
Components BC 101-ES User Manual www.dolphindispensers.co.uk
Spare Parts Position No. Part No Description 1 BC 65524 Hood for mounting bracket, complete, left 2 BC 65525 Hood for mounting bracket, complete, right 3 BC 65541 Crank 4 BC 65546 Mounting bracket, complete, left 5 BC 65547 Mounting bracket, complete, right 6 BC 65534 Spacer Ø25 mm, for spindle 7 BC 65531 End flange, left 8 BC 65532 End flange, right 9 BC 20040 Nut M5, stainless, self-locking 10 BC 65516 Aluminium table-top, 790 mm, white 11 BC 20038 Nut M6, stainless 12 BC 20047 Tight-fitting bolt M5 6x60 mm 13 BC 20041 Allen bolt, stainless, M6 x 25 mm 14 BC 20057 Locking ring Ø40 DIN 472 15 BC 65562 Spherical bearing 16 BC 20042 Allen bolt for crank (setscrew), stainless, M6 x 16 mm 17 BC 65402 Gas spring, 330 N, (Bansbach) BC 65407 Gas spring, 350 N, (Scandiloc) BC 65406 Gas spring replacement set with crank, screws etc. 18 BC 20065 Spacer, polyamide, Ø5.2 x Ø10 x 3 (only for installation with part. no.: 65402) BC 20855 Spacer, nylon, Ø5.3 x Ø10 x 1 (only for installation with part. no.: 65407) 19 BC 20044 Screw, countersunk, stainless, M4 x 10, torx 20 BC 20053 Screw, stainless, M6 x 20 mm, torx 21 BC 20835 Spacer, flat, stainless, A2, M5 x 10 22+23+24 BC 65551 Safety belt complete with buckle 25 BC 40068 Screw, stainless, M4 x 12 mm, torx BC 65520 Measuring band BC 65630 Pictogram, door Bell-Chem Products Company Haywood Way, Hastings, TN35 4PL Tel: 01424 202224 Fax: 01424 205200 www: dolphindispensers.co.uk info@dolphindispensers.co.uk DOLPHIN BC 101-ES User Manual www.dolphindispensers.co.uk
BABY CHANGE INSTALLATION INSTRUCTIONS
NAPPY CHANGING UNIT INSTALLATION Stainless Steel Units STEEL UNITS Each stainless steel unit can either be surface-mounted or recessed. A matching stainless steel cover frame is available for surfacemounted installations. RECESSED FIXING IN MASONRY Each unit has six recess mounting holes. Form the opening in the brick or blockwork wall, incorporating an appropriate lintel to span the opening. Install rough timber fixing grounds and screw fix the changing unit to the reveals of the opening using minimum 5mm screws. Before final tightening, insert packing shims as necessary for alignment and to obviate any distortion on tightening. Use either flat head screws with finishing washers and flat washers or pan head wood screws with flat washers, making sure that consideration is given to the operating clearance and that the back flange of the unit neatly masks the opening and the termination of the wall finish. RECESSED FIXING IN STUDWORK Timber double stud blocking is necessary around the opening. After locating the unit within the framed opening, insert packing shims as necessary for alignment and snug fitting. Secure the unit to the blocking using minimum 5mm flat head wood screws with finishing washers and flat washers or pan head wood screws with flat washers, making sure, as with all fixing methods, that consideration is given to the operating clearance. SURFACE MOUNTING The unit can be fixed directly through the back plate using screws and appropriate wall plugs and plastic caps to cover the screw heads. A matching stainless steel cover frame is available for surface-mounted installations which engages the changing unit with a snap fit. The cover frame covers the otherwise exposed edges and provides a neat finishing surround. RECOMMENDED MOUNTING HEIGHT TO BASE OF UNIT: Standard 900mm Wheelchair 750mm In all mountings, the flat fender washer must be inserted underneath the finishing washer: installing the unit using only the finishing washer may result in the washer biting directly into the body of the unit with consequent damage and loss of stability. Nappy changing units are no stronger than the anchors or substrates to which they are attached and as such must be firmly secured in order to support the loads for which they are intended.
NAPPY CHANGING UNIT INSTALLATION Polyethylene Units POLYETHYLENE UNITS Each unit has four mounting ports based on a traditional 400mm stud spacing. Two additional ports are provided for optional use. All fixings are supplied with each unit to cater for fixing to either solid masonry or studded wall constructions. RECOMMENDED MOUNTING HEIGHTS: Standard 900mm Wheelchair 750mm FIXING TO MASONRY Secure the unit to brick and concrete block substrates using four 5mm x min.75 mm wood screws into proprietary wall plugs. The flat fender washer is to be inserted underneath the finishing washer. Finally, insert the snap-fit plastic covers in each fixing port to cover the fixings. Fixing to studwork 1Mark out and drill fixing holes. Insert toggle. 2Twist toggle freely to gain purchase on the supporting member. There should be a minimum cavity clearance of 65mm to allow the toggle bar to turn. 3Push the integral disc along the toggle to make a snug purchase on the wall face. The toggle strands are rachetted to hold the disc in place. 4Cut off the surplus projection of the toggle and offer up the unit for fixing. 5Align and engage the fixing bolt in the threaded toggle bar with washers engaged. The flat fender washer is to be inserted underneath the finishing washer. Finally, insert the snap-fit plastic covers in each fixing port. Cover cap Toggle ALTERNATIVE FIXING METHOD TO STUDWORK The BC 100-EH/BC 100-EV unit can be fitted with the EZ Mount backer plate to provide an alternative method of fixing to studded walls. Two galvanised steel mounting bars are supplied, one pre-fixed to the rear of the unit and the other loose for fixing to the wall. The wall bar has a multitude of fixing holes to cater for variable stud positions.
Dolphin Solutions Ltd Southpoint, Compass Park, Junction Road Bodiam, TN32 5BS, United Kingdom T +44 (0)1424 202 224 info@dolphinsolutions.co.uk dolphinsolutions.co.uk Dolphin Solutions Ltd
SOUTHPOINT, COMPASS PARK, BODIAM, ROBERTSBRIDGE, TN32 5BST, UNITED KINGDOM + 44 (0)1424 202 224 TEL + 44 (0)1424 205 200 FAX hello@dolpinsolutions.co.uk dolphinsolutions.co.uk