CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

Similar documents
CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

CENTRE OF TESTING SERVICE INTERNATIONAL

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

CENTRE OF TESTING SERVICE INTERNATIONAL

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

FCC TEST REPORT On Behalf of. Global Tech China Limited. Solar Light(Large)/28W,16W. Model No.: Additional Model No: Please Refer To Page 15

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

FCC TEST REPORT On Behalf of GZTOD.CO., LTD The Multifunctional Platooninsert Model No.: YA30WSL-6AU6U

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

AUSTRALIA TEST REPORT For. KLM Lighting Co., Limited. LED Down Light. Model No.: KLM-HP30WSN

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

EMC test report AU01+E04

EMC T E S T R E P O R T

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC Test Report. Report Number: M030826

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

EMC VERIFICATION SUMMARY Report No.: SZHH

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

FCC 47 CFR PART 15 SUBPART B TEST REPORT SHENZHEN EAGLE TECHNOLOGY CO., LTD Mirror photo booth Model No.: EAGMR

FCC 47 CFR PART 15 SUBPART B TEST REPORT KST DIGITAL TECHNOLOGY LIMITED. Brushless Servo

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58

TEST REPORT... 1 CONTENT...

Test Report GUANGDONG EAST POWER CO., LTD

EMC Test report for LED Panel Light Models , , , , ,

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

1 SUMMARY OF STANDARDS AND RESULTS

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

EMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57

ELECTRONICS TESTING CENTER(ETC), TAIWAN

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC TEST REPORT For Gztod. Co., Ltd. Smart USB Charger Model No.: YA50WS3-8U

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

EMC TEST REPORT. For PEAK ELECTRONIC(HUIZHOU)CO., LTD. DAB/FM radio Model No.: DB-318 Additional Model No.: DB-318B, DB-318C, DB-318R, DB-318U

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

D. Guarnone (verifier)

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

EMC TEST REPORT For INNOKIN TECHNOLOGY CO., LIMITED. ITaste vv. Model No.: ITaste vv

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

EMC TEST REPORT for Repel-it. REPEL-IT ULTRASONIC PEST REPELLER Model No. : REPEL-IT/UPR/AN-B019

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

EMI -- T E S T R E P O R T

EMI T E S T R E P O R T

EMC TEST REPORT For LOKOLED LED Downlight Model No.: LL-17-45W-Floodlight-R-VL, LL-06-45W-18K/M

TABLE OF CONTENTS. 1. General Description of EUT General Information of Test Conducted Emission Tests 7-10

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: HARMONIC CURRENT EMISSIONS ON AC MAINS RESULT: Pass

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

BS EN TESTS ON THE RS-485 FFP2 THE BRAIN REVISION C

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

TEST REPORT Title 47-Telecommunication

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for

CE-EMC Test Report. United GULF GATE Trd. Co. MS EN 55032:2015 EN :2014 EN :2013 EN :2010+A1 :2015 JQL E

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

Declaration of Conformity.

Verification On Behalf of Shenzhen Leer Chuang Technology Co., Ltd.

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

EMC TEST REPORT For CE

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment

Page: 1 of 46 EMC TEST REPORT : SISF, SISF-2, SISFN-BLACK, SISFN-2-BLACK

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

Page: 1 of 41 EMC TEST REPORT. Product Name : Multi-socket with surge protection : SPG3-B-10, SPG3-B-15, SPG3-B-5, SPG3-B-6

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

BUREAU VERITAS. itaste svd

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

EMI T E S T R E P O R T

PT. SARANA KARYA SOLUSINDO.

Contents. Report No.: EMC-CE-2114 Page: 2 of 39

EMC Test Report. Shenzhen JT Detection Technology Co., Ltd. Product : Car LED headlight bulbs Brand Name :WEIYAO AUTO LED.

TABLE OF CONTENTS. 6. PHOTOGRAPH Photo of Conducted Emission Measurement Photo of Radiation Emission Measurement...

EMC Test report for Plug-in adaptor Models PM1Wab-ccc

Transcription:

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC 17025 EMC TEST REPORT TEST REPORT NUMBER : CNB3150602-00399-E 2/F., South Tower, Huoju Building, No.181, Canghai Road, Jiangdong Science and Technology Park, Ningbo, Zhejiang, China

TEST REPORT EN 61000-6-3:2007+A1:2011+AC:2012 Electromagnetic compatibility (EMC) Part 6-3: Generic standards Emission standard for residential, commercial and light-industrial environments EN 61000-6-1:2007 Electromagnetic compatibility (EMC) Part 6-1: Generic standards Immunity for residential, commercial and light-industrial environments Report Reference No.... CNB3150602-00399-E Date of issue... 15 June 2015 Testing Laboratory Name... Address... GZ test site: A101, No.65, Zhuji Road, Tianhe District, Guangzhou, Guangdong, China Testing location/ procedure... Full application of Harmonised standards Partial application of Harmonised standards Other standard testing method Applicant s name... Address... Test specification: Standard... EN 61000-6-3:2007+A1:2011+AC:2012, EN 61000-6-1:2007 Test Report Form No.... CTSEMC-1.0 TRF Originator... Master TRF... Dated 2009-01 All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the is acknowledged as copyright owner and source of the material. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description.... Car Charger Trade Mark... / Manufacturer... Model/Type reference... AST-CR113 Ratings... DC 24V Result... PASSED Compiled by: Supervised by: Approved by: Kate zhang / File administrators Duke yang / Technique principal Vincent yao / Manager Report No.: CNB3150602-00399-E Page 1 of 39

EMC -- T E S T R E P O R T Test Report No. : CNB3150602-00399-E 15 June 2015 Date of issue Type / Model... EUT... AST-CR113 Car Charger Applicant... Address... Telephone... Fax... Contact... Manufacturer... Address... Telephone... Fax... Contact... Factory... Address... Telephone... Fax... Contact... The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory. Report No.: CNB3150602-00399-E Page 2 of 39

TABLE OF CONTENTS Description Page 1 TEST STANDARDS... 5 2 SUMMARY... 5 2.1 GENERAL REMARKS... 5 2.2 FINAL ASSESSMENT... 5 3 EQUIPMENT UNDER TEST... 6 3.1 Power supply system utilised... 6 3.2 Short description of the Equipment under Test (EUT)... 6 3.3 EUT operation mode... 6 3.4 EUT configuration... 7 3.5 Performance level... 7 3.6 Definition related to the performance level... 7 4 TEST ENVIRONMENT... 8 4.1 Address of the test laboratory... 8 4.2 Test facility... 8 4.3 Environmental conditions... 8 4.4 Definitions of symbols used in this test report.... 8 4.5 Statement of the measurement uncertainty... 8 4.6 Measurement Uncertainty... 9 4.7 Test Description... 9 5 TEST CONDITIONS AND RESULTS... 10 5.1 Conducted disturbance... 10 5.2 Radiated disturbance (electric field)... 13 5.3 Electrostatic discharge... 19 5.4 Radiated, radio-frequency, electromagnetic field... 21 5.5 Electrical fast transients / Burst... 23 5.6 Surge... 25 5.7 Conducted disturbances induced by radio-frequency fields... 27 5.8 Power frequency magnetic field... 29 6 USED TEST EQUIPMENT... 31 7 TEST PHOTOGRAPHS... 33 7.1. Photo of power line conducted emission measurement (C.E.)... 33 7.2. Photo of radiated emission measurement (R.E. Electric field)... 33 7.3. Photo of electrostatic discharge Immunity measurement (E.S.D.)... 33 7.4. Photo of RF field strength Immunity measurement (R.S.)... 34 7.5. Photo of EFT/surge immunity measurement (E.F.T./Surge./Dips.)... 34 7.6. Photo of conducted disturbance Immunity measurement (C.S.)... 34 7.7. Photo of PFM field immunity measurement (P.F.M.F.)... 35 Report No.: CNB3150602-00399-E Page 3 of 39

8 External and Internal Photos of the EUT... 36 9 Manufacturer/ Approval holder Declaration... 39 Report No.: CNB3150602-00399-E Page 4 of 39

1 T E S T S T A N D A R D S 2 S U M M A R Y The tests were performed according to following standards: EN 61000-6-3:2007+A1:2011+AC:2012 Electromagnetic compatibility (EMC) Part 6-3: Generic standards Emission standard for residential, commercial and light-industrial environments EN 61000-6-1:2007 Electromagnetic compatibility (EMC) Part 6-1: Generic standards Immunity for residential, commercial and light-industrial environments 2.1 GENERAL REMARKS Date of receipt of test sample 05 June 2015 Testing commenced on 05~13 June 2015 Testing concluded on 15 June 2015 2.2 FINAL ASSESSMENT The EMC requirements pertaining to the technical standards and tested operation modes are - fulfilled. - not fulfilled. The equipment under test - fulfils the EMC requirements cited on page 1. - does not fulfil the EMC requirements cited on page 1. Report No.: CNB3150602-00399-E Page 5 of 39

3 E Q U I P M E N T U N D E R T E S T 3.1 Power supply system utilised Power supply voltage: DC 24V Other (Specified blank below) 3.2 Short description of the Equipment under Test (EUT) Number of tested samples: 1 Serial number: Prototype 3.3 EUT operation mode The equipment under test was operated during the measurement under the following conditions: Full Load Operating Mode: Full Load Emissions tests.: According to EN 61000-6-3, searching for the highest disturbance. Immunity tests. : According to EN 61000-6-1, searching for the highest susceptivity. Report No.: CNB3150602-00399-E Page 6 of 39

3.4 EUT configuration (The CDF filled by the applicant can be viewed at the test laboratory.) The following peripheral devices and interface cables were connected during the measurement: Not applicable 3.5 Performance level The test results shall be classified in terms of the loss of function or degradation of performance of the equipment under test, relative to a performance level defined by its manufacturer or the requestor of the test, or agreed between the manufacturer and the purchaser of the product. 3.6 Definition related to the performance level based on the used product standard based on the declaration of the manufacturer, requestor or purchaser Criterion A: Definition: Full Load performance within limits specified by the manufacturer, requestor or purchaser: Criterion B: Definition: temporary loss of function or degradation of performance which ceases after the disturbance ceases, and from which the equipment under test recovers its Full Load performance, without operator intervention: Criterion C: Definition: temporary loss of function or degradation of performance, the correction of which requires operator intervention: Criterion D: Definition: loss of function or degradation of performance, which is not recoverable, owing to damage to hardware or software, or loss of data: Report No.: CNB3150602-00399-E Page 7 of 39

4 T E S T E N V I R O N M E N T 4.1 Address of the test laboratory GZ test site: A101, No.65, Zhuji Road, Tianhe District, Guangzhou, Guangdong, China 4.2 Test facility The test facility is recognized, certified, or accredited by the following organizations: CNAS-Lab Code: L3394 has been assessed and proved to be in compliance with CNAS-CL01: 2006 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC 17025: 2005 General Requirements) for the Competence of Testing and Calibration Laboratories. IC-Registration No.: 8374A The 3m Alternate Test Site of has been registered by Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with Registration No. 8374A on May 22, 2014. FCC-Registration No.: 971995 EMC Laboratory has been registered and fully described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from the FCC is maintained in our files. Registration No.971995, July 13, 2012. 4.3 Environmental conditions During the measurement the environmental conditions were within the listed ranges: Temperature: 15~35 C Humidity: 25~75 % Atmospheric pressure: 86~106 kpa 4.4 Definitions of symbols used in this test report - The black square indicates that the listed condition, standard or equipment is applicable for this report. - The empty square indicates that the listed condition, standard or equipment is not applicable for this report. 4.5 Statement of the measurement uncertainty The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was calculated for all measurements listed in this test report acc. to CISPR 16-4 Specification for radio disturbance and immunity measuring apparatus and methods Part 4: Uncertainty in EMC Measurements and is documented in the CTS quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. Report No.: CNB3150602-00399-E Page 8 of 39

4.6 Measurement Uncertainty Test Item Frequency Range Uncertainty Note Conduction disturbance 150kHz~30MHz 1.22dB (1) Power disturbance 30MHz~300MHz 1.38dB (1) 30MHz~300MHz 3.14dB (1) Radiation emission (3m) 300MHz~1000MHz 3.18dB (1) (1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2. 4.7 Test Description 4.7.1 Description of Standards and Results EMISSION (EN 61000-6-3:2007+A1:2011+AC:2012) Description of Test Item Standard Limits Results Conducted disturbance at mains terminals Conducted disturbance at telecommunication port EN 61000-6-3:2007+A1:2011+AC:2012 -------- PASS EN 61000-6-3:2007+A1:2011+AC:2012 -------- N/A Radiated disturbance EN 61000-6-3:2007+A1:2011+AC:2012 -------- PASS Harmonic current emissions EN 61000-3-2:2006+A2:2009 Class D N/A Voltage fluctuations & flicker EN 61000-3-3:2013 -------- N/A Description of Test Item IMMUNITY (EN 61000-6-1:2007) Basic Standard Performance Criteria Results Electrostatic discharge (ESD) IEC 61000-4-2: 2008 B PASS Radio-frequency, Continuous radiated disturbance IEC 61000-4-3:2006 +A1:2007+A2:2010 A PASS Electrical fast transient (EFT) IEC 61000-4-4:2012 B PASS Surge (Input a.c. power ports) B PASS IEC 61000-4-5: 2005 Surge (Telecommunication ports) B N/A Radio-frequency, Continuous conducted disturbance IEC 61000-4-6: 2008 A PASS Power frequency magnetic field IEC 61000-4-8: 2009 A PASS Voltage dips, >95% reduction Voltage dips, 30% reduction IEC 61000-4-11: 2004 B N/A Voltage interruptions C N/A N/A is an abbreviation for Not Applicable. B N/A Report No.: CNB3150602-00399-E Page 9 of 39

5 T E S T C O N D I T I O N S AN D R E S U L T S 5.1 Conducted disturbance For test instruments and accessories used see section 6 part 6.2. 5.1.1 Description of the test location Test location: Shielded room 5.1.2 Description of the test set-up 5.1.2.1 Operating Condition The EUT is Full Load during the test, and the results of the maximum emanation are recorded 5.1.2.2 Block Diagram of Test Setup 5.1.3 Limits disturbance Frequency Maximum RF Line Voltage (db V) Quasi-peak Level Average Level 150kHz ~ 500kHz 79 66 500kHz ~ 30MHz 73 60 Note: (1) The tighter limit shall apply at the edge between two frequency bands. Report No.: CNB3150602-00399-E Page 10 of 39

5.1.4 Test result The requirements are Band width Frequency range Min. limit margin Fulfilled 9kHz 0.15 MHz - 30 MHz >5.47 db at 0.15-30 MHz Remarks: The limits are kept. For detailed results, please see the following page(s). Report No.: CNB3150602-00399-E Page 11 of 39

5.1.5 Test protocol Test point Operation mode Remarks: DC Power Port Full Load Result: - passed - not passed EUT Car Charger MODEL NO. AST-CR113 Operating Condition DC 24V Test Condition Ambient Temperature: 24 C Humidity: 56% Operator Eric No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbuv) (dbuv) (dbuv) (db) 1 0.3460 11.14 44.45 55.59 79.00-23.41 QP 2 0.3460 11.14 44.72 55.86 66.00-10.14 AVG 3 0.6860 10.96 43.29 54.25 73.00-18.75 QP 4 0.6860 10.96 43.57 54.53 60.00-5.47 AVG 5 1.0300 10.94 35.80 46.74 73.00-26.26 QP 6 1.0300 10.94 36.08 47.02 60.00-12.98 AVG 7 1.7180 10.87 21.34 32.21 73.00-40.79 QP 8 1.7180 10.87 21.57 32.44 60.00-27.56 AVG 9 2.0620 10.82 20.01 30.83 73.00-42.17 QP 10 2.0620 10.82 20.01 30.83 60.00-29.17 AVG 11 17.5180 10.26 7.55 17.81 73.00-55.19 QP 12 17.5180 10.26 2.40 12.66 60.00-47.34 AVG Note:Level=Reading+Factor. Margin= Limit-Level Report No.: CNB3150602-00399-E Page 12 of 39

5.2 Radiated disturbance (electric field) For test instruments and accessories used see section 6 part 6.1. 5.2.1 Description of the test location Test location : Semi-Anechoic chamber Test disturbance: 3 Meter 5.2.2 Description of the test set-up 5.2.2.1 Operating Condition The EUT is Full Load during the test, and the results of the maximum emanation are recorded 5.2.2.2 Block Diagram of Test Setup 5.2.3 Limits of disturbance Frequency (MHz) Distance (Meters) Field Strengths Limits (dbμv/m) 30 ~ 230 3 40 230 ~ 1000 3 47 Note: (1) The tighter limit shall apply at the edge between two frequency bands. (2) Distance refers to the distance in meters between the test instrument antenna and the closest point of any part of the E.U.T. Report No.: CNB3150602-00399-E Page 13 of 39

5.2.4 Test result The requirements are Band width Frequency range Min. limit margin Fulfilled 120kHz 30 MHz - 1000 MHz >2.45 db at 30-1000 MHz Remarks: The limits are kept. For detailed results, please see the following page(s). Report No.: CNB3150602-00399-E Page 14 of 39

5.2.5 Test protocol Test point: Operation mode Remarks: Horizontal Full Load Result: - passed - not passed EUT Car Charger Operating Condition DC 24V Test Condition Ambient Temperature: 24 C Humidity: 56% Operator Eric MODEL NO. AST-CR113 No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbμv) (dbμv/m) (dbμv/m) (db) 1 66.1800-20.35 49.17 28.82 40.00-11.18 QP 2 105.6000-17.70 52.22 34.52 40.00-5.48 QP 3 136.9200-16.08 50.35 34.27 40.00-5.73 QP 4 184.7100-14.80 52.35 37.55 40.00-2.45 QP 5 251.9400-11.34 50.73 39.39 47.00-7.61 QP 6 296.7600-2.28 41.75 39.47 47.00-7.53 QP Report No.: CNB3150602-00399-E Page 15 of 39

No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbμv) (dbμv/m) (dbμv/m) (db) 1 356.0000-11.25 49.45 38.20 47.00-8.80 QP 2 392.4000-10.64 51.43 40.79 47.00-6.21 QP 3 499.5000-8.12 36.45 28.33 47.00-18.67 QP 4 699.0000-3.70 33.38 29.68 47.00-17.32 QP 5 863.5000-0.69 29.20 28.51 47.00-18.49 QP 6 954.5000 0.38 29.02 29.40 47.00-17.60 QP Report No.: CNB3150602-00399-E Page 16 of 39

Test point: Operation mode Remarks: Vertical Full Load Result: - passed - not passed No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbμv) (dbμv/m) (dbμv/m) (db) 1 66.7200-20.41 49.84 29.43 40.00-10.57 QP 2 106.6800-17.61 43.28 25.67 40.00-14.33 QP 3 136.1100-16.09 45.55 29.46 40.00-10.54 QP 4 174.4500-15.62 44.10 28.48 40.00-11.52 QP 5 184.1700-14.85 42.24 27.39 40.00-12.61 QP 6 251.6700-11.36 37.99 26.63 47.00-20.37 QP Report No.: CNB3150602-00399-E Page 17 of 39

No. Frequency Factor Reading Level Limit Margin Detector (MHz) (db) (dbμv) (dbμv/m) (dbμv/m) (db) 1 352.5000-11.31 40.71 29.40 47.00-17.60 QP 2 389.6000-10.68 42.62 31.94 47.00-15.06 QP 3 570.2000-5.63 29.32 23.69 47.00-23.31 QP 4 706.0000-3.46 31.82 28.36 47.00-18.64 QP 5 869.1000-0.86 28.31 27.45 47.00-19.55 QP 6 972.7000 0.21 28.58 28.79 47.00-18.21 QP Note:Level=Reading+Factor. Margin= Limit-Level Report No.: CNB3150602-00399-E Page 18 of 39

5.3 Electrostatic discharge For test instruments and accessories used see section 6 part 6.3. 5.3.1 Description of the test location Test location : Test location no. 2 Power supply: Test condition: DC 24V Ambient Temperature: 24, Humidity:56% Date of test : 05~13 June 2015 Operator : Eric 5.3.2 Severity of levels electrostatic discharge 5.3.2.1 Severity level: Contact discharge at ±4KV air discharge at ±8KV Level 5.3.2.2 Performance criterion: B 5.3.3 Description of the test set-up 5.3.3.1 Operating Condition Test Voltage Contact Discharge (kv) Test Voltage Air Discharge (kv) 1 2 2 2 4 4 3 6 8 4 8 15 X Special Special The EUT is Full Load during the test, and the results of the maximum emanation are recorded 5.3.3.2 Block Diagram of Test Setup Report No.: CNB3150602-00399-E Page 19 of 39

5.3.4 Test specification: Contact discharge voltage: 2 kv 4 kv Air discharge voltage: 2 kv 4 kv 8 kv Discharge impedance: Discharge factor: 330 / 150 pf 1 sec. Number of discharges: 10 Type of discharge: Direct discharge Air discharge Contact discharge Indirect discharge Contact discharge Polarity: Positive Negative Discharge location: see photo documentation of the test set-up all external locations accessible by hand horizontal plate (HCP) vertical coupling plate (VCP) 5.3.5 Test result The requirements are Fulfilled Performance Criterion: B Remarks: During the test no deviation was detected to the selected operation mode(s). Report No.: CNB3150602-00399-E Page 20 of 39

5.4 Radiated, radio-frequency, electromagnetic field For test instruments and accessories used see section 6 part 6.4. 5.4.1 Description of the test location Test location : Power supply: Test condition: GTEM chamber DC 24V Date of test : 05~13 June 2015 Operator : Eric Ambient Temperature: 24, Humidity:56% 5.4.2 Severity levels of radiated, Radio-frequency, electromagnetic field 5.4.2.1 Severity level: 3V/m and 1V/m 5.4.2.2 Performance criterion: A 5.4.3 Description of the test set-up 5.4.3.1 Operating Condition Level Field strenght(v/m) 1 1 2 3 3 10 X Special The EUT is Full Load during the test, and the results of the maximum emanation are recorded 5.4.3.2 Block Diagram of Test Setup Report No.: CNB3150602-00399-E Page 21 of 39

5.4.4 Test specification: Frequency range: Field strength: EUT - antenna separation: Modulation: Frequency step: 80 MHz to 1000 MHz 3 V/m 3 m AM: 80 % sinusoidal 1000Hz 1 % with 3 s dwell time Antenna polarisation: horizontal vertical Frequency range: Field strength: EUT - antenna separation: Modulation: Frequency step: 1.4GHz to 2GHz 3 V/m 3 m AM: 80 % sinusoidal 1000Hz 1 % with 3 s dwell time Antenna polarisation: horizontal vertical Frequency range: Field strength: EUT - antenna separation: Modulation: Frequency step: 2GHz to 2.7GHz 1 V/m 3 m AM: 80 % sinusoidal 1000Hz 1 % with 3 s dwell time Antenna polarisation: horizontal vertical 5.4.5 Test result The requirements are Fulfilled Performance Criterion: A Remarks: During the test no deviation was detected to the selected operation mode(s). Report No.: CNB3150602-00399-E Page 22 of 39

5.5 Electrical fast transients / Burst For test instruments and accessories used see section 6 part 6.5. 5.5.1 Description of the test location Test location : Test location no. 2 Power supply: Test condition: DC 24V Date of test : 05~13 June 2015 Operator : Eric 5.5.2 Severity levels of electrical fast transients / Burst 5.5.2.1 Severity level: ±500V for DC power supply lines Level Ambient Temperature: 24, Humidity:56% Open circuit output test voltage and repetition rate of the impulses On power port, PE V peak (KV) Repetition rate (KHz) Voltage peak On I/O signal, data and control ports Repetition rate (KHz) 1 0.5 5 or 100 0.25 5 or 100 2 1 5 or 100 0.5 5 or 100 3 2 5 or 100 1 5 or 100 4 4 5 or 100 2 5 or 100 X Special Special Special Special 5.5.2.2 Performance criterion: B 5.5.3 Description of the test set-up 5.5.3.1 Operating Condition The EUT is Full Load during the test, and the results of the maximum emanation are recorded 5.5.3.2 Block Diagram of Test Setup Report No.: CNB3150602-00399-E Page 23 of 39

5.5.4 Test specification: Coupling network: 0.5 kv 1 kv 2 kv Coupling clamp: 0.5 kv 1 kv Burst frequency: 5.0 khz Coupling duration: 60 s Polarity: positive negative 5.5.5 Coupling points Cable description: DC power line: Positive + Negative Screening: screened unscreened Status: passive active Signal transmission: analogue digital Length: 5.5.6 Test result 1.5 m The requirements are Fulfilled Performance Criterion: B Remarks: During the test no deviation was detected to the selected operation mode(s). Report No.: CNB3150602-00399-E Page 24 of 39

5.6 Surge For test instruments and accessories used see section 6 part 6.6. 5.6.1 Description of the test location Test location : Test location no. 2 Power supply: Test condition: DC 24V Date of test : 05~13 June 2015 Operator : Eric 5.6.2 Severity levels of surge 5.6.2.1 Severity level: Line to line: ±0.5KV Level 5.6.2.2 Performance Criterion: B 5.6.3 Description of the test set-up Ambient Temperature: 24, Humidity:56% Test Voltage (KV) 1 0.5 2 1.0 3 2.0 4 4.0 X 5.6.3.1 Operating Condition Special The EUT is Full Load during the test, and the results of the maximum emanation are recorded 5.6.3.2 Block Diagram of Test Setup Report No.: CNB3150602-00399-E Page 25 of 39

5.6.4 Test specification: Pulse amplitude-power line sym.: Source impedance: 2 + 18µF Pulse amplitude-power line unsym: Source impedance: 12 + 9µF Number of surges: 0.5 kv 1 kv 2 kv 4 kv 0.5 kv 1 kv 2 kv 4 kv 5 Surges/Phase angle Phase angle: 0 90 180 270 Repetition rate: 60 s Polarity: positive negative 5.6.5 Coupling points Cable description: DC power line: Positive + Negative Screening: screened unscreened Status: passive active Signal transmission: analogue digital Length: 1.5 m 5.6.6 Test result The requirements are Fulfilled Performance Criterion: B Remarks: During the test no deviation was detected to the selected operation mode(s). Report No.: CNB3150602-00399-E Page 26 of 39

5.7 Conducted disturbances induced by radio-frequency fields For test instruments and accessories used see section 6 part 6.7. 5.7.1 Description of the test location Test location : Test location no. 2 Power supply: Test condition: DC 24V Ambient Temperature: 24, Humidity:56% Date of test : 05~13 June 2015 Operator : Eric 5.7.2 Severity levels of conducted disturbances induced by radio-frequency fields discharge 5.7.2.1 Severity Level: 3V Level Field Strength (V) 1 1 2 3 3 10 X Special 5.7.2.2 Performance Criterion: A 5.7.3 Description of the test set-up 5.7.3.1 Operating Condition The EUT is Full Load during the test, and the results of the maximum emanation are recorded 5.7.3.2 Block Diagram of Test Setup Report No.: CNB3150602-00399-E Page 27 of 39

5.7.4 Test specification: Frequency range: Test voltage: Modulation: Frequency step: 0.15 MHz to 80 MHz 3 V AM: 80 % sinusoidal 1000Hz 1 % with 3 s dwell time 5.7.5 Coupling points Cable description (Port1): DC power line: Positive + Negative Screening: screened unscreened Status: passive active Signal transmission: analogue digital Length: 5.7.6 Test result 0.3 m The requirements are Fulfilled Performance Criterion: A Remarks: During the test no deviation was detected to the selected operation mode(s). Report No.: CNB3150602-00399-E Page 28 of 39

5.8 Power frequency magnetic field For test instruments and accessories used see section 6 part 6.8. 5.8.1 Description of the test location Test location : Test location no. 2 Power supply: Test condition: DC 24V Ambient Temperature: 24, Humidity:56% Date of test : 05~13 June 2015 Operator : Eric 5.8.2 Severity levels of magnetic field immunity 5.8.2.1 Severity Level: 3A/m Level Magnetic Field Strength (A/m) 1 1 2 3 3 10 4 30 5 100 5.8.2.2 Performance Criterion: A X Special 5.8.3 Description of the test set-up 5.8.3.1 Operating Condition The EUT is Full Load during the test, and the results of the maximum emanation are recorded 5.8.3.2 Block Diagram of Test Setup Report No.: CNB3150602-00399-E Page 29 of 39

5.8.4 Test specification: Test frequency: Continuous field: Duration (Continuous field): Short duration (1-3s): 50 Hz 3 A/m 60 s each Axis 3s Axis: x-axis y-axis z-axis 5.8.5 Test result The requirements are Fulfilled Performance Criterion: A Remarks: During the test no deviation was detected to the selected operation mode(s). Report No.: CNB3150602-00399-E Page 30 of 39

6 U S E D T E S T EQ U I P M E N T 6.1 Radiated disturbance (electric field) Item Test Equipment Manufacturer Model No. Serial No. Last Cal. 1 Signal analyzer ROHDE & SCHWARZ FSIQ26 100311 2015/03/24 2 EMI Test Receiver ROHDE & SCHWARZ ESVS 10 842885/001 2014/11/04 3 Biconical Antenna ROHDE & SCHWARZ HK116 100221 2015/03/24 4 Log per Antenna ROHDE & SCHWARZ HL223 100226 2015/03/24 5 Log per Antenna ROHDE & SCHWARZ HL050 100186 2015/03/24 6 Pre-Amplifier EMC EMC330 980113 2015/03/24 7 Pre-Amplifier EMC EMC012645 980114 2015/03/24 8 EMI Test Software Farad EZ-EMC N/A N/A 6.2 Conducted Disturbance Item Test Equipment Manufacturer Model No. Serial No. Last Cal. 1 EMI Test Receiver ROHDE & SCHWARZ ESCI 100868 2014/11/04 2 Artificial Mains ROHDE & SCHWARZ ESH3-Z5 832479/025 2014/11/04 3 Artificial Mains ROHDE & SCHWARZ ESH3-Z6 100140 2014/11/04 4 Pulse Limiter ROHDE & SCHWARZ ESHS-Z2 100301 2014/11/04 5 EMI Test Software Farad EZ-EMC N/A N/A 6.3 Electrostatic Discharge Item Test Equipment Manufacturer Model No. Serial No. Last Cal. 1 ESD Simulator Schlöder SESD 200 0302016 2015/03/24 6.4 RF Field Strength Susceptibility Item Test Equipment Manufacturer Model No. Serial No. Last Cal. 1 Signal Generator ROHDE & SCHWARZ SMY 01 843215/014 2014/11/04 2 Signal Generator ROHDE & SCHWARZ SML03 102986 2014/11/04 3 Amplifier KALMUS 713FC 7385-1 2014/11/04 4 Power Meter ROHDE & SCHWARZ NRVS 842856/049 2014/11/04 5 Field Probe ETS HI-6005 00075047 2014/11/11 6 RS Test Software Farad EZ-RS N/A N/A 6.5 Electrical Fast Transient/Burst Item Test Equipment Manufacturer Model No. Serial No. Last Cal. 1 EMC test system Transient-1000 EMC Partner Transient-1000 HAR1000-78 2014/11/04 2 3-Phase Coupling Network EMC Partner CDN1000 CDN1000-08 2014/11/04 3 Coupling Clamp EMC Partner SFT 410 0302015 2014/11/04 4 Genecs Software EMC Partner N/A N/A N/A Report No.: CNB3150602-00399-E Page 31 of 39

6.6 Surge Item Test Equipment Manufacturer Model No. Serial No. Last Cal. 1 EMC test system Transient-1000 EMC Partner Transient-1000 HAR1000-78 2014/11/04 2 3-Phase Coupling Network EMC Partner CDN1000 CDN1000-08 2014/11/04 3 Coupling Clamp EMC Partner SFT 410 0302015 2013/11/05 4 Genecs Software EMC Partner N/A N/A N/A 6.7 Conducted Susceptibility Item Test Equipment Manufacturer Model No. Serial No. Last Cal. 1 RF generator / amplifier Schlöder CDG 6000 HU906007 2014/11/04 2 CDN Schlöder CDN M3 A3003008 2014/11/04 3 CDN Schlöde CDN T2 A3010005 2014/11/04 4 Attenuator Abschwächer DC-500MHz N/A 2014/11/04 5 EM injection clamp Liithi EM101 35670 2013/11/06 6 CDG-6000 Software Schlöder N/A N/A N/A 6.8 Power Frequency Magnetic Field Susceptibility Item Test Equipment Manufacturer Model No. Serial No. Last Cal. 1 Power frequency mag-field generator System EM TEST EMS61000-8K 409001 2014/11/04 Report No.: CNB3150602-00399-E Page 32 of 39

7 T E S T P H O T O G R A P H S 7.1. Photo of power line conducted emission measurement (C.E.) 7.2. Photo of radiated emission measurement (R.E. Electric field) 7.3. Photo of electrostatic discharge Immunity measurement (E.S.D.) Report No.: CNB3150602-00399-E Page 33 of 39

7.4. Photo of RF field strength Immunity measurement (R.S.) 7.5. Photo of EFT/surge immunity measurement (E.F.T./Surge.) 7.6. Photo of conducted disturbance Immunity measurement (C.S.) Report No.: CNB3150602-00399-E Page 34 of 39

7.7. Photo of PFM field immunity measurement (P.F.M.F.) Report No.: CNB3150602-00399-E Page 35 of 39

8 E x t e r n a l a n d I n t e r n a l P h o t o s of t h e E U T External view 1 External view 2 External view 3 Report No.: CNB3150602-00399-E Page 36 of 39

External view 4 PCB view 1 PCB view 2 Report No.: CNB3150602-00399-E Page 37 of 39

Following Number External view Report No.: CNB3150602-00399-E Page 38 of 39

9 M a n u f a c t u r e r / A p p r o v a l h o l d e r D e c l a r a t i o n The following identical model(s): N/A Belong to the tested device: Product description: Car Charger Model name: AST-CR113 Report No.: CNB3150602-00399-E Page 39 of 39