EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

Similar documents
FCC TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

RADIO TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

RADIO TEST REPORT (AS/NZS 4268)

FCC DoC TEST REPORT. TESTED : Sep. 01 to 02, 2010 APPLICANT : LOGITECH FAR EAST LTD.

RADIO TEST REPORT (AS/NZS 4268)

RADIO TEST REPORT. ADDRESS: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

VCCI TEST REPORT. TESTED : June 22 to 23, 2010 APPLICANT : LOGITECH FAR EAST LTD.

FCC DoC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

DFS TEST REPORT. ISSUED BY : Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

TEST REPORT... 1 CONTENT...

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

EMC TEST REPORT. according to

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

FCC Test Report (15.249)

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

EMC TEST REPORT. Report No.: CE10-LIE040101E

DFS TEST REPORT. ADDRESS: 6F.-2, No.68, Liancheng Rd., Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.)

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

EN RF Test Report

EMC Test Report. Report Number: M030826

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

FCC DoC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

RF EXPOSURE REPORT. Sagemcom 250 route de l empereur, Rueil Malmaison,92500, France

EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

CONFORMANCE TEST REPORT FOR EN /-6

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

ELECTRONICS TESTING CENTER, TAIWAN

CE EMC TEST REPORT. MANUFACTURER : TP-Link Technologies Co., Ltd.

CE EMC TEST REPORT. TESTED : June 22 to 23, 2010 APPLICANT : LOGITECH FAR EAST LTD.

EMC TEST REPORT. According to

2620 Modular Measurement and Control System

ELECTRONICS TESTING CENTER(ETC), TAIWAN

FCC DoC TEST REPORT. ISSUED BY : Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

EMC TEST REPORT for LEDELS LIGHTING CO., LTD. LED module Model No. : LL-F12T4815X6B

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

EMC test report AU01+E04

DFS TEST REPORT (WinCE System)

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

CE EMC TEST REPORT. According to

CE TEST CERTIFICATION

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

CE TEST CERTIFICATION

Communication Certification Laboratory

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

9. Electrostatic Discharge Immunity Test (ESD)

Test Certificate A sample of the following product received on May 13, 2011 and tested on May 13, 18 and 19, 2011 complied with the requirements of,

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

CE EMC Test Certification

CE EMC TEST REPORT. ADDRESS: No. 25, Wu-Gong 6th Rd., Wu Ku Industrial Park, Taipei Hsien, Taiwan, R. O. C.

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

C E R T I F I C A T I O N

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

VCCI TEST REPORT. According to. Class B ITE. Equipment : USB video camera

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

VCCI TEST REPORT. According to. V-3/ , TECHNICAL REQUIREMENTS, Class B ITE. Equipment : USB video camera. Model No. : V-U0017 / V-U0021

TEST REPORT. Product: Thermo-Hygrometer Model No.: FL-201, FL-201W Trade mark: N/A Report No.: TCT151014E001 Issued Date: Oct. 15, 2015.

CE EMC TEST REPORT. according to. EN V1.4.1 ( ) and EN V1.2.1 ( ) Equipment : WIRELESS 11B CARDBUS CARD

Test Report GUANGDONG EAST POWER CO., LTD

1 SUMMARY OF STANDARDS AND RESULTS

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

CE EMC Test Report GUANGZHOU DMKEMOTOR CO. LTD

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

FCC Test Report RF141003E10B-1. Report No.: PY FCC ID: EX6150. Test Model: Received Date: Apr. 17, Test Date: Apr. 22 to July 21, 2015

CE EMC Test Report. : Class 1 Bluetooth Data Module : BT740-SA, BT730-SA, BT740-SC, BT730-SC

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

CE EMC Test Report. : Bluetooth Dual Mode UART AT featuring smartbasic. (please refer to for more details.)

FCC Test Report (Zigbee-Thread)

TEST REPORT. Building 6,XinXinTian Industrial Park, XinSha Road, ShaJing, Baoan District, ShenZhen, China

EMC Testing Report. StarCam Genie N/A MICRO-STAR INT L CO., LTD.

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

MIL STD 461F TEST REPORT. For. Rugged PDA. Model Number: P37B. Trade Name: N/A. Issued to

Unilab(Shanghai) Co.,Ltd. Report No. : UL CE010-1 Page 1 of 27 EMC TEST REPORT

CE EMC Test Report. Approved & Reviewed by: Ty: XXX. Kent Chen / Assistant Manager. Report No.: EH Page : 1 of 44 Report Version: Rev.

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

EMC standards. Presented by: Karim Loukil & Kaïs Siala

FCC TEST REPORT (15.407)

EN v1.2.1 ( ) TEST REPORT FOR b/g PCIExpress Minicard MODEL NUMBER: AR5BXB63 REPORT NUMBER: 06U

FCC TEST REPORT (RFID)

TEST REPORT. Issued for:

FCC 47 CFR PART 15 SUBPART B

CE EMC Test Report. : Bluetooth 4.2 module (BLE only) (Refer to item for more details)

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

C E R T I F I C A T I O N

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

Transcription:

EMC TEST REPORT REPORT NO. : RM110613E07 MODEL NO. : M-R0027 RECEIVED : June 13, 2011 TESTED : June 17, 2011 ISSUED : June 22, 2011 APPLICANT : LOGITECH FAR EAST LTD. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C. ISSUED BY : Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch Hsin Chu Laboratory LAB ADDRESS : No. 81-1, Lu Liao Keng, 9th Ling, Wu Lung Tsuen, Chiung Lin Hsiang, Hsin Chu Hsien 307, Taiwan This test report consists of 22 pages in total. It may be duplicated completely for legal use with the approval of the applicant. It should not be reproduced, except in full, without the written approval of our laboratory. The client should not use it to claim product certification, approval, or endorsement by TAF or any government agencies. The test results in the report only apply to the tested sample. Report No.: RM110613E07 1 Report Format Version 4.0.0

Table of Contents RELEASE CONTROL RECORD...3 1 CERTIFICATION...4 2 SUMMARY OF TEST RESULTS...5 3 GENERAL INFORMATION...6 3.1 GENERAL DESCRIPTION OF EUT...6 3.2 GENERAL DESCRIPTION OF TEST MODE...6 3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS...7 3.4 DESCRIPTION OF SUPPORT UNITS...8 3.5 CONFIGURATION OF SYSTEM UNDER TEST...8 4 IMMUNITY TEST...9 4.1 GENERAL DESCRIPTION...9 4.2 GENERAL PERFORMANCE CRITERIA DESCRIPTION...10 4.3 EUT OPERATING CONDITION...12 4.4 ELECTROSTATIC DISCHARGE IMMUNITY TEST (ESD)...13 4.4.1 TEST SPECIFICATION...13 4.4.2 TEST INSTRUMENTS...13 4.4.3 TEST PROCEDURE...14 4.4.4 DEVIATION FROM TEST STANDARD...14 4.4.5 TEST SETUP...15 4.4.6 TEST RESULTS...16 4.5 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST (RS)..18 4.5.1 TEST SPECIFICATION...18 4.5.2 TEST INSTRUMENTS...18 4.5.3 TEST PROCEDURE...19 4.5.4 DEVIATION FROM TEST STANDARD...19 4.5.5 TEST SETUP...19 4.5.6 TEST RESULTS...20 5 PHOTOGRAPHS OF THE TEST CONFIGURATION...21 6 APPENDIX - INFORMATION ON THE TESTING LABORATORIES...22 Report No.: RM110613E07 2 Report Format Version 4.0.0

RELEASE CONTROL RECORD ISSUE NO. REASON FOR CHANGE DATE ISSUED RM110613E07 Original release June 22, 2011 Report No.: RM110613E07 3 Report Format Version 4.0.0

1 CERTIFICATION PRODUCT: 2.4GHz Cordless Mouse BRAND NAME: Logitech MODEL NO.: M-R0027 APPLICANT: LOGITECH FAR EAST LTD. TESTED: June 17, 2011 TEST SAMPLE: ENGINEERING SAMPLE STANDARDS: EN 301 489-1 V1.8.1 (2008-04) EN 301 489-3 V1.4.1 (2002-08) EN 55022:2006+A1:2007 (Not Applicable) EN 61000-3-2:2006+A1:2009+A2:2009 (Not Applicable) EN 61000-3-3:2008 (Not Applicable) EN 61000-4-2:2009 EN 61000-4-3:2006+A1:2008+A2:2010 EN 61000-4-4:2004+A1:2010 (Not Applicable) EN 61000-4-5:2006 (Not Applicable) EN 61000-4-6:2009 (Not Applicable) EN 61000-4-11:2004 (Not Applicable) The above equipment (Model: M-R0027) has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts of the measurements of the sample s EMC characteristics under the conditions specified in this report. PREPARED BY :, DATE: June 22, 2011 ( Claire Kuan, Specialist ) APPROVED BY :, DATE: June 22, 2011 ( Ken Lu, Manager ) Report No.: RM110613E07 4 Report Format Version 4.0.0

2 SUMMARY OF TEST RESULTS The EUT has been tested according to the following specifications: EMISSION Standard Test Type Result Remarks Conducted Test NA Not Applicable EN 55022:2006 +A1:2007 Telecommunication Ports Conducted Test NA Not Applicable EN 61000-3-2:2006 +A1:2009+A2:2009 EN 61000-3-3:2008 Radiated Test NA Not Applicable Harmonic current emissions Voltage fluctuations & flicker NA NA Not Applicable Not Applicable IMMUNITY Standard Test Type Result Remarks EN 61000-4-2:2009 Electrostatic discharge immunity test PASS Radiated, EN 61000-4-3:2006 radio-frequency, +A1:2008+A2:2010 electromagnetic field PASS immunity test EN 61000-4-4:2004 Electrical fast transient / burst immunity test. NA Meets the requirements of Performance Criterion A Meets the requirements of Performance Criterion A Not Applicable EN 61000-4-5:2006 Surge immunity test NA Not Applicable EN 61000-4-6:2009 Immunity to conducted disturbances, induced by radio-frequency fields NA Not Applicable Voltage dips, short EN 61000-4-11:2004 interruptions and voltage variations immunity tests NA Not Applicable Report No.: RM110613E07 5 Report Format Version 4.0.0

3 GENERAL INFORMATION 3.1 GENERAL DESCRIPTION OF EUT PRODUCT MODEL NO. POWER SUPPLY 2.4GHz Cordless Mouse M-R0027 DC 1.5V from battery MODULATION TYPE GFSK OPERATING FREQUENCY 2405MHz ~ 2474MHz NUMBER OF CHANNEL 12 ANTENNA TYPE DATA CABLE I/O PORT PCB printed antenna with 2.82dBi antenna gain NA NA ASSOCIATED DEVICES NA NOTE: 1. The above EUT information was declared by manufacturer and for more detailed feature descriptions, please refer to the manufacturer's specifications or User's Manual. 3.2 GENERAL DESCRIPTION OF TEST MODE The EUT was tested under following test mode: Test Mode Mode 1 Description Normal mode Report No.: RM110613E07 6 Report Format Version 4.0.0

3.3 GENERAL DESCRIPTION OF APPLIED STANDARDS The EUT is a RF product. According to the specifications of the manufacturer, it must comply with the requirements of the following standards: EN 301 489-1 V1.8.1 (2008-04), EN 301 489-3 V1.4.1 (2002-08) Emission tests: EN 55022:2006+A1:2007 (Not Applicable) EN 61000-3-2:2006+A1:2009+A2:2009 (Not Applicable) EN 61000-3-3:2008 (Not Applicable) Immunity tests: EN 61000-4-2:2009 EN 61000-4-3:2006+A1:2008+A2:2010 EN 61000-4-4:2004 (Not Applicable) EN 61000-4-5:2006 (Not Applicable) EN 61000-4-6:2009 (Not Applicable) EN 61000-4-11:2004 (Not Applicable) All test items have been performed and recorded as per the above standards. Report No.: RM110613E07 7 Report Format Version 4.0.0

3.4 DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units. The following support units or accessories were used to form a representative test configuration during the tests. No. Product Brand Model No. Serial No. FCC ID NOTEBOOK COMPUTER ASUS A2400H 49NG038455 FCC DoC 1 (For ESD test) NOTEBOOK COMPUTER (For RS test) ASUS M2400N 38NP051951 NA 2 2.4GHz Transceiver Logitech C-U0008 NA NA No. Signal cable description 1 NA 2 NA Note: 1. All power cords of the above support units are unshielded (1.8m). 3.5 CONFIGURATION OF SYSTEM UNDER TEST 1. NOTEBOOK COMPUTER 2. 2.4GHz Transceiver Wireless TEST TABLE EUT Report No.: RM110613E07 8 Report Format Version 4.0.0

4 IMMUNITY TEST 4.1 GENERAL DESCRIPTION Product Standard: EN 301 489-1 (2008-04), EN 301 489-3 (2002-08) Basic Standard, Specification, and Performance Criteria: EN 61000-4-2 EN 61000-4-3 EN 61000-4-4 EN 61000-4-5 EN 61000-4-6 Electrostatic Discharge ESD: 8kV air discharge, 4kV Contact discharge, Performance Criterion B Radio-Frequency Electromagnetic Field Susceptibility Test RS: 80-1000 MHz, 1400-2700 MHz, 3V/m, 80% AM (1kHz), Performance Criterion A Electrical Fast Transient/Burst - EFT, Power line: 1kV, Signal line: 0.5kV, Performance Criterion B Surge Immunity Test: 1.2/50 us Open Circuit Voltage, 8 /20 us Short Circuit Current, line to line 0.5 kv, line to earth - 1kV, Performance Criterion B Conducted Radio Frequency Disturbances Test CS: 0.15-80 MHz, 3Vrms, 80% AM, 1kHz, Performance Criterion A EN 61000-4-11 Voltage Dips: i) 0% residual for 0.5 cycle, Performance Criterion B ii) 0% residual for 1 cycle, Performance Criterion B iii) 70% residual for 25 cycle, Performance Criterion B Voltage Interruptions: i) 0% residual for 250 cycle, Performance Criterion B is required for EUT with battery back-up, Performance Criterion C is required for EUT without battery back-up. Report No.: RM110613E07 9 Report Format Version 4.0.0

4.2 GENERAL PERFORMANCE CRITERIA DESCRIPTION 1 2 3 4 The Requirement of Performance Criteria Performance criteria for continuous phenomena applied to transmitters (CT) Performance criteria for transient phenomena applied to transmitters (TT) Performance criteria for continuous phenomena applied to receivers (CR) Performance criteria for transient phenomena applied to receivers (TR) Criterion A of the applicable class shall apply Criterion B of the applicable class shall apply Criterion A of the applicable class shall apply Criterion B of the applicable class shall apply Report No.: RM110613E07 10 Report Format Version 4.0.0

The phenomena allowed during and after test in each criterion are clearly stated in the following table: Class 1 SRD equipment Criteria During test After test A B Operate as intended. No loss of function. For equipment type II the minimum performance shall be 12dB SINAD No unintentional responses May be loss of function (one or more) No unintentional responses Operate as intended. For equipment type II the communication link shall be maintained No loss of function No degradation of performance No loss of stored data or user programmable functions Operate as intended Lost function(s) shall be self-recoverable No degradation of performance No loss of stored data or user programmable functions Class 2 SRD equipment Criteria During test After test A B Operate as intended. No loss of function. For equipment type II the minimum performance shall be 6dB SINAD NO UNINTENTIONAL RESPONSES MAY BE LOSS OF FUNCTION (ONE OR MORE) No unintentional responses Operate as intended. For equipment type II the communication link shall be maintained No loss of function No degradation of performance No loss of stored data or user programmable functions Operate as intended Lost function(s) shall be self-recoverable No degradation of performance No loss of stored data or user programmable functions Class 3 SRD equipment Criteria During test After test A and B MAY BE LOSS OF FUNCTION (ONE OR MORE) No unintentional responses NOTE: This device belongs to Type I, class 3 SRD equipment. Operate as intended, for equipment type II the communication link may be lost, but shall be recoverable by user No degradation of performance Lost functions shall be self-recoverable Report No.: RM110613E07 11 Report Format Version 4.0.0

4.3 EUT OPERATING CONDITION a. Turn on the power of all equipment. b. Set the EUT under typical use condition. c. EUT presses "H" messages to link with support unit 1 (Notebook Computer) under transmission condition continuously via wireless. d. Repeat steps a-c. Report No.: RM110613E07 12 Report Format Version 4.0.0

4.4 ELECTROSTATIC DISCHARGE IMMUNITY TEST (ESD) 4.4.1 TEST SPECIFICATION Basic Standard: EN 61000-4-2 Discharge Impedance: 330 ohm / 150 pf Discharge Voltage: Air Discharge 2, 4, 8, 10, 12, 15kV (Direct) Contact Discharge 2, 4, 6, 8kV (Indirect) Polarity: Positive & Negative Number of Discharge: Minimum 20 times at each test point Discharge Mode: Single Discharge Discharge Period: 1 second minimum 4.4.2 TEST INSTRUMENTS DESCRIPTION & CALIBRATED CALIBRATED MODEL NO. SERIAL NO. MANUFACTURER DATE UNTIL NoiseKen, ESD Simulator ESS-100L(A) 0189C01491 Aug. 03, 2010 Aug. 02, 2011 NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML/ROC and NIST/USA. 2. The test was performed in ESD room A. Report No.: RM110613E07 13 Report Format Version 4.0.0

4.4.3 TEST PROCEDURE a. Electrostatic discharges were applied only to those points and surfaces of the EUT that are accessible to users during normal operation. b. The test was performed with at least ten single discharges on the pre-selected points in the most sensitive polarity. c. The time interval between two successive single discharges was at least 1 second. d. The ESD generator was held perpendicularly to the surface to which the discharge was applied and the return cable was at least 0.2 meters from the EUT. e. Contact discharges were applied to the non-insulating coating, with the pointed tip of the generator penetrating the coating and contacting the conducting substrate. f. Air discharges were applied with the round discharge tip of the discharge electrode approaching the EUT as fast as possible (without causing mechanical damage) to touch the EUT. After each discharge, the ESD generator was removed from the EUT and re-triggered for a new single discharge. The test was repeated until all discharges were complete. g. At least ten single discharges (in the most sensitive polarity) were applied to the Horizontal Coupling Plane at points on each side of the EUT. The ESD generator was positioned at a distance of 0.1 meters from the EUT with the discharge electrode touching the HCP. h. At least ten single discharges (in the most sensitive polarity) were applied to the center of one vertical edge of the Vertical Coupling Plane in sufficiently different positions that the four faces of the EUT were completely illuminated. The VCP (dimensions 0.5m x 0.5m) was placed vertically to and 0.1 meters from the EUT. 4.4.4 DEVIATION FROM TEST STANDARD No deviation As per client requests, the following discharge levels were also applied: Contact Discharge 6, 8kV for contact discharge. Air Discharge 10, 12, 15kV for direct air discharge. Report No.: RM110613E07 14 Report Format Version 4.0.0

4.4.5 TEST SETUP 1m 0.1m Vertical coupling plane Nearest Wall PS ESD Generator Horizontal coupling plane EUT 0.5mm Isolation Support 80cm 470k X4 Reference Ground Plane For the actual test configuration, please refer to the related item Photographs of the Test Configuration. NOTE: TABLE-TOP EQUIPMENT The configuration consisted of a wooden table 0.8 meters high standing on the Ground Reference Plane. The GRP consisted of a sheet of aluminum at least 0.25mm thick, and 2.5 meters square connected to the protective grounding system. A Horizontal Coupling Plane (1.6m x 0.8m) was placed on the table and attached to the GRP by means of a cable with 940kΩ total impedance. The equipment under test, was installed in a representative system as described in section 7 of EN 61000-4-2, and its cables were placed on the HCP and isolated by an insulating support of 0.5mm thickness. A distance of 1-meter minimum was provided between the EUT and the walls of the laboratory and any other metallic structure. Report No.: RM110613E07 15 Report Format Version 4.0.0

4.4.6 TEST RESULTS MODE Mode 1 INPUT POWER DC 1.5V from battery ENVIRONMENTAL CONDITIONS (START OF TEST) 24 deg. C, 45 % RH, 1001 hpa ENVIRONMENTAL CONDITIONS (End of Test) 24 deg. C, 45 % RH, 1001 hpa TESTED BY Barry Lee Discharge Level (kv) 2, 4, 8, 10, 12, 15 TEST RESULTS OF DIRECT APPLICATION Polarity Contact Test Point Air Discharge (+/-) Discharge Performance Criterion +/- 1 ~ 5 NA NOTE (1) A No conductive surfaces found, therefore no contact discharge was executed. Description of test point: Please refer to following page for representative mark only. Discharge Level (kv) TEST RESULTS OF INDIRECT APPLICATION Horizontal Vertical Polarity Test Point Coupling Coupling (+/-) Plane Plane Performance Criterion 2, 4, 6, 8 +/- 1 ~ 4 NOTE (1) NOTE (1) A Description of test point: 1. Front side 2. Right side 3. Left side 4. Rear side NOTE: (1) There was no change compared with the initial operation during the test. (2) The EUT function held temporarily, but could be self-recoverable after the test. (2) The cursor function held temporarily, but could be self-recoverable after the test. Report No.: RM110613E07 16 Report Format Version 4.0.0

DESCRIPTION OF TEST POINT 1 2 3 5 4 Report No.: RM110613E07 17 Report Format Version 4.0.0

4.5 RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST (RS) 4.5.1 TEST SPECIFICATION Basic Standard: EN 61000-4-3 Frequency Range: 80 MHz - 1000 MHz 1400 MHz - 2700 MHz Field Strength: 3 V/m Modulation: 1kHz Sine Wave, 80%, AM Modulation Frequency Step: 1 % of momentary frequency Polarity of Antenna: Horizontal and Vertical Antenna Height: 1.5m Dwell Time: 3 seconds 4.5.2 TEST INSTRUMENTS DESCRIPTION & SERIAL CALIBRATED CALIBRATED MODEL NO. MANUFACTURER NO. DATE UNTIL AR Power Amplifier 150W1000M3 311567 NA NA AR Power Amplifier 60S1G3M1 306171 NA NA AR LOG ANTENNA AT5080ANT 309740 NA NA BOONTON RF Voltage Meter 4232A 93801 Dec. 17, 2010 Dec. 16, 2011 R&S Signal Generator SMIQ03B 102114 Aug. 31, 2010 Aug. 30, 2011 Electric Field Probe EMR-20 AB-0039 Sep. 23, 2010 Sep. 22, 2011 ADT RS Test Workbench(Software) ADT_RS_V7.6.3 NA NA NA NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are traceable to NML/ROC and NIST/USA. 2. The test was performed in Chamber Room No. B. 3. The transmit antenna was located at a distance of 2.0 meters from the EUT. Report No.: RM110613E07 18 Report Format Version 4.0.0

4.5.3 TEST PROCEDURE The test procedure was in accordance with EN 61000-4-3 a. The testing was performed in a fully-anechoic chamber. b. The frequency range is swept from 80 MHz to 1000 MHz, 1400 MHz to 2700 MHz with the signal 80% amplitude modulated with a 1kHz sine wave. c. The dwell time at each frequency shall not be less than the time necessary for the EUT to be exercised and to respond, but shall in no case be less than 0,5s. d. The field strength level was 3V/m. e. The test was performed with the EUT exposed to both vertically and horizontally polarized fields on each of the four sides. 4.5.4 DEVIATION FROM TEST STANDARD No deviation 4.5.5 TEST SETUP EUT RF Amplifier RF Generator and control system Monitorin g system For the actual test configuration, please refer to the related item Photographs of the Test Configuration. NOTE: TABLETOP EQUIPMENT The EUT installed in a representative system as described in section 7 of EN 61000-4-3 was placed on a non-conductive table 0.8 meters in height. The system under test was connected to the power and signal wire according to relevant installation instructions. Report No.: RM110613E07 19 Report Format Version 4.0.0

4.5.6 TEST RESULTS MODE Mode 1 INPUT POWER DC 1.5V from battery ENVIRONMENTAL CONDITIONS (START OF TEST) TESTED BY 24 deg. C, 58 % RH, 1001 hpa Kyle Hunag ENVIRONMENTAL CONDITIONS (END OF TEST) 24 deg. C, 58 % RH, 1001 hpa Frequency (MHz) Result Polarity Azimuth Field Strength (V/m) 80-1000 PASS V&H 0 3 80-1000 PASS V&H 90 3 80-1000 PASS V&H 180 3 80-1000 PASS V&H 270 3 1400-2700 PASS V&H 0 3 1400-2700 PASS V&H 90 3 1400-2700 PASS V&H 180 3 1400-2700 PASS V&H 270 3 Obser- vation NOTE Performance Criterion A NOTE: There was no change compared with initial operation during the test. Report No.: RM110613E07 20 Report Format Version 4.0.0

5 PHOTOGRAPHS OF THE TEST CONFIGURATION ESD TEST RS TEST Report No.: RM110613E07 21 Report Format Version 4.0.0

6 INFORMATION ON THE TESTING LABORATORIES We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited and approved according to ISO/IEC 17025: Copies of accreditation certificates of our laboratories obtained from approval agencies can be downloaded from our web site: www.adt.com.tw/index.5.phtml. If you have any comments, please feel free to contact us at the following: Linko EMC/RF Lab: Tel: 886-2-26052180 Fax: 886-2-26052943 Hsin Chu EMC/RF Lab: Tel: 886-3-5935343 Fax: 886-3-5935342 Hwa Ya EMC/RF/Safety/Telecom Lab: Tel: 886-3-3183232 Fax: 886-3-3185050 Email: service.adt@tw.bureauveritas.com Web Site: www.adt.com.tw The address and road map of all our labs can be found in our web site also. --- END --- Report No.: RM110613E07 22 Report Format Version 4.0.0

CONSTRUCTION PHOTOS OF EUT Page 1

Page 2

Page 3

Page 4