No: /18 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

Similar documents
No: /16 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación UNIT DESCRIPTION

Installation Instructions

No: /16 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación DESCRIPTION

No: /17 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

with Light Level, Isolated Relay and Manual On features

No: /17 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

CX-100. Installation Instructions. PIR Occupancy Sensor SPECIFICATIONS

Installation Instructions

No: /17 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación

Installation Instructions

v3 360 Passive Infrared Line Voltage Occupancy Sensor

Installation Instructions

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4

O ccupancy and Light Level Sensor L ow Vo l tage Ceiling Fixture Mount

INSTRUCTIONS UNIVERSAL TRAY STAND - SMALL AASFT24 AASLH24 AASLP24

Installing the FSP-211 Sensor in Light Fixture

SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

STL200/277 Installation Manual STL200/277

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

ASSEMBLY AND INSTALLATION INSTRUCTIONS

ASSEMBLY AND INSTALLATION INSTRUCTIONS

STL200/277 Installation Manual STL200/277

STEALTH. STL200 Installation Manual. Specifications: STL200 STL200H STL200HB. Switching Capacity: 8 amps

STEALTH. STL110 Installation Manual. Specifications: STL110 STL110HB STL110H STL110R. Switching Capacity:

INSTRUCTIONS VERTICAL GROW SHELF SYSTEM VGS300 & VGS600

Mini Sensor. Outdoor Motion Sensor. Installation Manual

3000W multi Pir light controller

Smart Task Motion Activated Task Light Installation Manual

Eco-$mart, Inc. TOLL FREE:(888) FAX:(941)

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Important Safety Instructions

3000W MULTI PIR LIGHT CONTROLLER

ASYX 2.0 S3-S4-L3-L4-L5-L6 Wall Installation Instructions

Dual Technology Wall Mount Occupancy Sensor

2 Pendant Adjustment. Pendant Slider Plate. 3/4 (19mm) IP, (29mm) O.D. Knockouts. 1/2 (13mm) IP, (22mm) O.D. Knockout

Dual Technology Wall Mount Occupancy Sensor

High/Low Bay Passive Infrared Occupancy Sensor

SmartBox RAB. Installation Manual. Outdoor Motion Sensor. It s easy to add. motion detection to all your outdoor lights! Contents.

Technical Application Guide

Infrared Wall Mount Occupancy Sensor

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires

Datasheet ENGLISH Halogen lamp 120W with motion sensor ( ) Halogen lamp 400W with motion sensor ( )

Tuff Dome. Installation Manual. vandal resistant. Outdoor Motion Sensor. Contents. Specifications. Switching Capacity:

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

FFLED18 INSTALLATION INSTRUCTIONS

Wireless Occupancy Sensor User Guide

DLA-E (Philips EvoKit) The DLA-E is designed to install in the mounting slot of the Philips EvoKit SR retrofit kit.

Smart Post RAB. Installation Manual. Outdoor Motion Sensor. It s easy to add. motion detection to your post lantern! Contents.

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

INSTALLATION INSTRUCTION Adjustable Spot - Endurance Sign Lighting

Installation Manual. Specifications: Cautions: TURN OFF ALL POWER AT CIRCUIT BREAKER / FUSE PANEL.

ROUND LIGHTPLANE 1 3D FLUSH

Universal TechBox Series

Instruction Sheet VDM-200-T. Tilt Wall Mount

Instruction Sheet. VDM Series FIXED & TILT WALL MOUNT

Dialight Daylight Harvesting Sensor User Guide

Installation Instructions SKU# , Rated Voltage V~ 50Hz

1010/T Series Incandescent Illuminator

SUPERPLANE 2.5 INSTALLATION INSTRUCTIONS WALL/SURFACE BACK MOUNT. A nd Avenue, Unit 1 Oakland,

INSTALLATION MANUAL PBC-UMS

User Guide Guide de l utilisateur Guía del Usuario

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE LED SURFACE AMBIENT LUMINAIRE FACTORY SETTINGS. Configuration Value

Dual Technology Ceiling Mount Sensor

INSTALLATION INSTRUCTION

Heritage Solar Lamp Post

Instruction Sheet. VDM Series. Tilt Low Profile Mount

INSTALLATION MANUAL PBL-UMP

Instruction Sheet. VDM Series FIXED & TILT WALL MOUNT

INSTALLATION INSTRUCTION Accent

INSTALLATION INSTRUCTION Accent

FFLED18 INSTALLATION INSTRUCTIONS

Custom Pendant- Hardwire Assembly and Installation Instructions

WATTSTOPPER OEM SENSOR GUIDE INTEGRATED LIGHTING CONTROLS. designed to be better.

INSTALLATION INSTRUCTION Grand Accent

Item No: MIN :2.95in/75MM MAX:15.75in/400MM MAX: n

Round or Square Type IC Wall Wash Housing with Lamp for Flangeless Trims

INSTALLATION INSTRUCTIONS SUPERPLANE 4 WALL MOUNT. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

USER S MANUAL. NX-5 Series. Power Supply Built-in Compact Multi-voltage Photoelectric Sensor

SMARTBULLET SMSBULLET2X12

WALL LANTERN ITEM # MODEL #LWS1204C ATTACH YOUR RECEIPT HERE. Serial Number. Purchase Date

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR

12 24 VAC/VDC ±10% (inhibited when voltage is applied) min. pulse width duration = 50 ms. Normal mode or Background Analysis mode

SUPERPLANE TM 4 RECESSED SP4R

INSTALLATION INSTRUCTION Accent

Installation Instructions

HP 2 SERIES Integral Driver - Solid State LED

Installation Instructions (For Dealer or Contractor)

L DN 2810 FL DE 3925 L DN 2810 FL PIR DE 3925 L DN 5630 FL DE 3925 L DN 5630 FL PIR DE 3925 L DN 9850 FL DE 3925 L DN 9850 FL PIR DE 3925

Tilting, Swiveling & Rotating Flat Panel Wall Mount

NOVA-EXT Versatile Projector Mount Model: NOVA-EXT

Woven Leather Chandelier Large Assembly and Installation Instructions

PARTS INCLUDED TOOLS & PARTS NEEDED Do not mount on vibrating surfaces. appro to 2.5 meters 12M

Universal Projector Ceiling Mount Model: DPM-45

EBDSM-PRM Product Guide

AUC Cell Assembly Torque Stand. User Manual

A-dec 574L and 575L Dental Lights on a Cabinet or Wall INSTALLATION GUIDE

Transcription:

Wattstopper Outdoor PIR Motion Sensors No: 24259 04/18 rev. 1 Installation Instructions Instructions d Installation Instrucciones de Instalación Catalog Numbers Les Numéros de Catalogue Los Números de Catálogo: EW-200-120, EW-200-277 Country of Origin: Made in China Pays d origine: Fabriqué en Chine País de origen: Hecho en China Box Contents One (1) EW-200-120, EW-200-277 Accessory bag: Cover plate for 4" round outdoor junction box, with two cover plate attachment hole plugs, cover plate gasket, cover plate screws & screw covers (4 ea), lens mask, wire nuts (3) Installation instructions Please read all of the installation instructions before installing this product. SPECIFICATIONS Voltage: EW-200-120...120VAC, 60Hz EW-200-277...277VAC, 60Hz Mountable Locations... Wall, ceiling or under eaves Operating Temperature... -40 to 130 F (-40 to 55 C) Lens Coverage:... 270 Load Ratings...0 1000W ballast or tungsten @120VAC...0 1000W ballast @277VAC Motor Load:...1/6 HP @20VAC...1/3 HP @277VAC Current Consumption Without Isolated Relay... 22 ma max. With Isolated Relay... 34 ma max. Time Delay Adjustment... 12sec. 16min. Light Level Adjustment...0.5FC 200FC Isolated Relay on EW-200 (both -120 & -277 models) Normally Open & Normally Closed contacts. Isolated Relay Rating:... 1A @ 30VAC/DC UL 773A Raintight Rated IEC-IP-55 RateD U.S.Patents: 4,787,722; 5,640,113 WARNING THIS UNIT USES HIGH VOLTAGE. IT SHOULD ONLY BE INSTALLED BY QUALIFIED PERSONS THAT ARE THOROUGHLY FAMILIAR WITH PROPER SAFETY PROCEDURES AND ELECTRICAL AND BUILDING CODES FOR THE INSTALLATION LOCATION. TO AVOID FIRE, SHOCK, ELECTROCUTION, OR DEATH.TURN OFF POWER AT THE CIRCUIT BREAKER OR FUSE BOX AND TEST TO ENSURE POWER IS OFF BEFORE WIRING. UNIT DESCRIPTION The EW sensors are outdoor passive infrared (PIR) motion sensors rated for wet conditions. They are preassembled with a junction box cover and are ready to install to standard round outdoor junction boxes. The EW sensors utilize advanced PIR technology and a superior lens design to detect motion. PIR sensing is passive, and detects the difference between infrared energy in motion and the background space. COVERAGE PATTERN Coverage is shown as tested in a controlled setting with the unit mounted at 8 ft at a 10 tilt from the horizontal surface. The actual outside coverage pattern may vary substantially at the specific installation site and is dependent on several factors including weather conditions, external light sources, mounting height and sensor tilt. Coverage adjustment: The front of the sensor housing can be moved up and down for easy coverage adjustment.

COVERAGE PATTERN (CONT D) 90 Top View EW-200 270 coverage 8ft (2.4m) Side View 9.5ft (3m) 25ft (8m) 52.5ft (16m) Masking: Opaque adhesive tape is supplied so that sections of the sensor s lens can be masked to restrict coverage in unwanted areas. MOTION SENSOR PLACEMENT Mounting Options Install onto a standard 4 round outdoor junction box. Mount to a flat, stable, vibration-free surface. Mount vertically or horizontally, usually to a wall, ceiling or under an eave. Careful consideration must be given to sensor placement. PIR sensors detect the difference between infrared energy in motion and the background space. To be detected, a person or vehicle must be within the sensor s coverage pattern and have an unobstructed view of the sensor. Horizontally Mounted: For horizontal mounting, such as under eaves, rotate the sensor housing as shown in the diagrams below. Make sure that the gasket is seated properly. 1 2 3 Loosen the two screws at the back of the sensor. Rotate the sensor housing 180. Replace and tighten the screws. Vertically Mounted: The sensor comes assembled and ready for vertical cover plate mounting, as shown in the illustration below. Attach mounting post to the cover plate: Make sure that the O-ring is on the threaded end of the mounting post before installing. O-ring Lightly screw the mounting post into the cover plate by rotating the sensor. Adjust the sensor to the desired angle, then tighten the locking ring. Locking ring and collar must be securely seated against the cover plate locking ring. 2

MOUNTING AND SENSOR POSITIONING GUIDELINES WARNING: LAMP BULB MUST BE 1/2 INCH OR MORE FROM SENSOR HOUSING Mount to flat, stable, vibration-free surface Avoid runoff; sheltered locations preferred Mount motion sensor level Mount sensor below lamps to avoid heat effects Aim motion sensor downward to limit sensing Do not mount by vents or above lamps 3

WIRING AND INSTALLATION WARNING: WHEN USED WITH LAMP HOLDERS THE LAMPS NEED TO BE 1/2 OR GREATER FROM THE SENSOR. CAUTION: TURN POWER OFF AT THE CIRCUIT BREAKER BEFORE INSTALLING SENSOR.SENSOR MUST BE INSTALLED BY QUALIFIED PERSONNEL ONLY. Wire connections for sensor Gasket IMPORTANT! Thread wires through gasket before connecting to Controlled Loads 4 round outdoor junction-box RED BLACK Cover plate Attach cover plate assembly and gasket to the junction box with 4 screws and screw covers (supplied) IMPORTANT! Make sure that the gasket seats properly when attaching the cover plate WHITE TE: Weather proof caulking may be required around junction box and cover plate to provide a weatherproof seal in some installations. Isolated Relay Wires (N/O, COMMON, N/C) (EW-200 models only) Wire connections when attaching lamp holders (Isolated relay wires not shown) Gasket IMPORTANT! Thread wires through gasket before connecting to additional Controlled Loads (optional) Cover plate Attach cover plate assembly and gasket to the junction box with 4 screws and screw covers (supplied) IMPORTANT! Make sure that the gasket seats properly when attaching the cover plate 4 round outdoor junction-box RED BLACK Lamp Holder (CANLET lamp holder shown) WHITE TE: Weather proof caulking may be required around junction box and cover plate to provide a weatherproof seal in some installations. WIRING AND INSTALLATION Wire the sensor as shown: BLACK wire from sensor to line voltage. WHITE wire from sensor to Neutral. RED wire is connected to lighting loads, if used, as shown (see diagram above and below), not to exceed load rating (see Specifications, front cover). Isolated Relay (See Specifications, front cover, for rating). Connect the wires necessary to the application that requires this output. ORANGE (Common) (must be used for proper operation). BROWN (Normally Closed) (Open when occupancy is detected). YELLOW (Normally Open) (Closed when occupancy is detected). TE: When power is restored to the sensor, the lights will turn on. If no motion is detected by the sensor, the lights will remain on for approximately one minute and then turn off. (See Security Override). 4

Multiple sensors (optional) connected in parallel Multiple loads (optional) connected in parallel TE: When power is restored to the sensor, the lights will turn on. If no motion is detected by the sensor, the lights will remain on for approximately one minute and then turn off. (See Security Override). TESTING AFTER INSTALLATION To facilitate coverage testing, the factory setting for Time Delay is 12 seconds, and the Light Level is at Maximum. If you want to test a sensor for intended detection or operation: 1. Make sure that the time delay is set to 12 seconds and the light level is set to maximum (clockwise to the sun icon. The dials are located on the bottom of the sensor.) 2. Adjust sensor and lamp holders to the desired position. 3. Ensure that power has been restored to the sensor. 4. Move into the location to be tested; lights should turn on. Stand still. In about 12 seconds the lights should turn off. Move or walk and the lights should turn on. Repeat this process to test other locations. Make sensor coverage adjustments as needed (see Sensor Positioning). TE: When power is restored to the sensor, the lights will turn on for approximately one minute. (See Security Override.) TE: If the lights do not turn on with movement in the area after they have turned off in step 4, the level of daylight may be too high and the sensor s light level adjustment is keeping the sensor inactive. Wait until daylight levels have reduced before testing again. 5. See Dial Adjustments, for guidelines to adjust the time delay and light level to the desired settings for operation. DIAL ADJUSTMENTS Time Delay and Light Level control dials are located on the bottom of the sensor. 1. Adjust Time Delay: The time delay is the amount of time that elapses before lights turn off since the sensor last detected motion. This can be set from 12 seconds to 16 minutes. For normal operation, the time delay should be set to 1 minute or more. In areas where there is mostly walk through movement, the time delay amount can be low. In areas where people may stop and remain for periods of time, the time delay should be set to a higher amount, preferably 16 minutes. 2. Adjust Light Level: Turning the light level adjustment dial raises or lowers a daylight level in the sensor. When the light of the day rises above this set level, the sensor becomes inactive; this keeps the lights off when there is enough daylight present. We suggest initially setting the light level adjustment to half way between minimum and maximum. If a different setting is desired after installation, then follow the Making Changes procedures. TIME DELAY DIAL LIGHT LEVEL DIAL Minimum: 12 seconds Maximum: 16 minutes Minimum = Maximum= MAKING CHANGES If you want the lights to turn on/high sooner turn the light level dial toward the sun icon, as desired; this raises the light level setting. (Remember, the sensor must detect motion for lights to turn on.) The lights turn on sooner in the evening. The lights stay on longer in the morning. If you want the lights to turn on later turn the light level dial toward the moon icon, as desired; this lowers the light level setting. (Remember, the sensor must detect motion for lights to turn on.) The lights turn on later in the evening. The lights turn off sooner in the morning. 5

Additional Notes: When testing adjustments, make sure not to block any of the light that is reaching the sensor or reflect any light into the sensor s lens. The sensor requires about 5 seconds for light level adjustments to take effect. This feature prevents the lights from turning on/high and off/low with quick light reflections, from car windows for example. The sensor will not turn lights off/low until no motion is detected and the time delay elapses. SECURITY OVERRIDE The EW sensors have an override-on feature which allows lights to be turned on for the set time delay period. If there is an installed switch turning the switch off then on, turns the lights on. If no motion is detected by the sensor, the lights will remain on for approximately one minute and then turn off. This will also happen when power is restored after a power outage. TE: If the lights do not turn on, the sensor may be inactive due to the daylight level. Turn the switch off for 5 seconds, then turn it on. The lights should turn on as described above. TROUBLESHOOTING Lights do not turn off: 1. The sensor may be detecting movement outside the desired coverage area. The sensor s lens may need to be masked to block unwanted coverage (see Masking). If this does not solve the problem, see step 2. 2. Test to see that the sensor is operating properly. Set the time delay to minimum (12 seconds). Remain still, or move out of range of the sensor. If there is no movement in the coverage area, the sensor should turn lights off/low in 12 seconds. Reset the time delay to the desired value. 3. If the lights do not turn off/low, have a person qualified to check high voltage connections verify that the sensor and lighting are wired correctly (see Wiring and Installation). CAUTION: Make sure power is turned off at the circuit breaker before checking wiring. 4. If the sensor is wired correctly, call our Technical Support number. Lights turn on/high when there is sufficient daylight: Decrease the light level setting, as desired (counterclockwise toward the moon icon, see Dial Adjustments). Lights do not turn on/high: 1. If there is a controlling switch installed, make sure that it is turned on. 2. If the lights do not turn on/high when lights are needed increase the light level setting, as desired (clockwise toward the sun icon, see Dial Adjustments). 3. Have a person qualified to check high voltage connections verify that the sensor and lighting are wired correctly (see Wiring and Installation). CAUTION: Make sure power is turned off at the circuit breaker before checking wiring. 4. If the sensor is wired correctly, call our Technical Support number. ORDERING INFORMATION Catalog # EW-200-120 Description 120VAC, 60Hz, 270 Outdoor/Indoor PIR Motion Sensor with Isolated Relay, includes cover plate EW-200-277 277VAC, 60Hz, 270 Outdoor/Indoor PIR Motion Sensor with Isolated Relay, includes cover plate When ordering, add (-W) for Arctic White or (-G) for Architectural Gray to catalog numbers. THIRD-PARTY ORDERING INFORMATION Additional color-matched lamp holder accessories (Outdoor incandescent lamp holders, Shrouds for PAR 20 & PAR 38 lamps, and Round outdoor junction boxes & cover plates) are available through your local distributor, or for further assistance call CANLET at 1-888-461-5307 WARRANTY INFORMATION INFORMATIONS RELATIVES À LA GARANTIE INFORMACIÓN DE LA GARANTÍA Wattstopper warranties its products to be free of defects in materials and workmanship for a period of five (5) years. There are no obligations or liabilities on the part of Wattstopper for consequential damages arising out of, or in connection with, the use or performance of this product or other indirect damages with respect to loss of property, revenue or profit, or cost of removal, installation or reinstallation. Wattstopper garantit que ses produits sont exempts de défauts de matériaux et de fabrication pour une période de cinq (5) ans. Wattstopper ne peut être tenu responsable de tout dommage consécutif causé par ou lié à l utilisation ou à la performance de ce produit ou tout autre dommage indirect lié à la perte de propriété, de revenus, ou de profits, ou aux coûts d enlèvement, d installation ou de réinstallation. Wattstopper garantiza que sus productos están libres de defectos en materiales y mano de obra por un período de cinco (5) años. No existen obligaciones ni responsabilidades por parte de Wattstopper por daños consecuentes que se deriven o estén relacionados con el uso o el rendimiento de este producto u otros daños indirectos con respecto a la pérdida de propiedad, renta o ganancias, o al costo de extracción, instalación o reinstalación. No. 24259 04/18 rev. 1 Copyright 2018 Legrand All Rights Reserved. Copyright 2018 Tous droits réservés Legrand. Copyright 2018 Legrand Todos los derechos reservados. 800.879.8585 www.legrand.us/wattstopper