ET M3792_a. DC 6, 12, 15, 20, 24 V AC 12, 24, 42, 230 V Voltage range U N

Similar documents
Installation / Monitoring Technique

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

Installation- / Monitoring technique

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Relay interface modules A

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

62 Series - Power relays 16 A. Features / /

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

40 Series - Miniature P.C.B. Relays A

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/300

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

48 Series - Relay interface modules A. Features

mm wide Low coil power PCB or 93 series sockets. Copper side view. 1 CO (SPDT) 6/10 250/400 1, /0.2/ (12/10) AgNi

Safety Technique. SAFEMASTER Emergency Stop Module LG 5925

38 Series - Relay interface modules A. Features /

38 Series - Relay Interface Modules A

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

Miniature Power Relay MSR

RELOG. All-or-nothing Relay

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Output of three-phase motors at 50 Hz and 400 V

38 Series - Relay interface modules A

38 Series - Relay interface modules A

30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

Installation- / Monitoring Technique

2 or 4 pole changeover contact Plug-in/Faston 187

Safety Relay H-462. Dimensions LxWxH(in mm) Size 1: 57,8 x20,5 x48,6 Size 2: 67,4 x20,5 x48,6

62.22 Copper side view

The power in relays and timers since Catalogue

relais A mark Relay modules

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay LG 5928

Controls Contactors and Contactor Assemblies Special Applications

PIR6WT-1Z interface - time relays

E-STOP relays, safety gate monitors

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Type CP-S, CP-C & CP-A Switch mode

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

SIGMA Terminal components

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

PSR-SCP- 24DC/ESD/5X1/1X2/300

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Modular step relays 16 A

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Interface relays and optocouplers Product group picture

Thermistor motor protection relays

Pluggable interface relays CR-P Pcb relays

PCB relay for DC voltage, polarized, monostable or bistable

Capacitor Switching Contactors

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Step relays 10 A SЕRIES. Lighting control in corridors (for hotels, offices and hospitals) Bedroom light control. Living room light control

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Pluggable interface relays CR-U Universal relays

No-wear isolation of potentials in terminal block design

05/09/2014

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

MasterINTERFACE 39 Series - Relay interface modules

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Process displays For standard signals, temperature, resistance measurement

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

MasterINTERFACE 39 Series - Relay interface modules

08/07/2015

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

AC/DC. Monitoring Technique. VARIMETER IMD Insulation monitor RN 5897/020

316 PHOENIX CONTACT. RIF-1 for miniature and solid-state relays Page 334. RIF-2 for industrial relays Page 342. RIF-3 for octal relays Page 346

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

02/11/2015

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

02/11/2015

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

XUA1 - AC Voltage and phase balance relay

08/07/2015

Relay modules, Relay sockets, Plug relays

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

A rated contacts PCB mount - bifurcated terminals. Copper side view

Liquid level monitoring relay CM-ENS.2x

DZD 92 L. Wiring diagram. Time domains. Function. Dimensional drawing. Indicators. Accessories

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Thermistor motor protection relays

Safety relays - PSR-SCP- 24DC/ESD/4X1/

IMPULSE SWITCH, REMOTE SWITCH

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Environmental Influences. Display. Inputs and Outputs. Electromagnetic Compatibility. Communication Interfaces. Insulation Strenght.

Switching relay terminal block; Relay with 1 changeover contact (1u); with miniature switching relay

A rated contacts Flange mount/faston 250 (6.3 x 0.8 mm) connection

Relays, Timers, Interface Modules, Sockets and Accessories Catalogue. The power in relays and timers since 1954

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Transcription:

Control Technique Connecting Module Interface Relay Pluggable HC 09 078 According to DIN EN 18 output contacts with monostable PCB-relay OA 8 Version with bistable PCB-relay OB 9 Contact material with fine gold High thermal current up to I th = 1 A with relays OA 8 and OB 9 Large temperature range: - 0... + 8 C As option with free-wheel diode or varistor between A1/A As option with AgSnO or with hard gold Width: 1.8 mm ET11.07 + OA ET11.0 ET11.01 OA 8 OA 7 OA8 OB 9 Circuit Diagrams A1(+) 11 1 A 1 1 M79_a A1 11 A 1 1 M79_a A1 11 A 1 1 M79_a 1 M79_a Approvals and Markings Technical Data Coil Nominal voltage U N DC, 1, 0,, 8, 0, 1 V, others on request DC, 1, 1, 0, V AC 1,,, 0 V Voltage range 0.7... U N 0.8... 1. U N 0.8... 1. U N 0.8... 1.1 U N Nominal consumption 0. W 0. W 0. W 1 W / 1. VA.0 NO.1 C/O.01 1 NO.11 1 C/O.01 1 NO.11 1 C/O.01 1 NO.11 1 C/O Contact material as option AgSnO or with hard gold Rated insulation voltage AC 0 V Limiting continuous current I th A A 1 A 1 A Switching capacity min./max. Switching capacity AC 1 at AC 0 V DC 1 at DC V / 000 VA 0 / 00 W NC: 1 A, NO: A / 00 VA / 00 W NC: 1 A, NO: A / 000 VA / 00 W NC: 1 A, NO: A / 000 VA / 00 W NC: 1 A, NO: A Electrical life 1. x x x x Operate time / release time 8 / ms 7 / ms 7 / ms Other x Mechanical life 0 x 0 x 0 x DC 1 x AC Temperature range - 0... + 7 C - 0... + 1 C - 0... + 1 C -... + 0 C Insulation to DIN EN 0-1, DIN EN 0178 Overvoltage category AC 0 V Degree of pollution Rated impulse voltage III est voltage (1 min) Contact-coil Contact-contact Surge voltage (1. - 0 ms) Contact-coil Clearance and creepage distance to DIN EN 070, DIN EN 0; Contact-coil kv AC eff.. kv AC eff. kv kv AC eff. 1. kv AC eff. 8 mm Weight 1 g 17 g 17 g 1 g All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. 1 1.0.1 en / 7

Characteristics,,0 1,8 UB max. without load M07_a 1, 1, UB max. atimax. U U B N 1, 1,0 0,8 OA 8: Operating voltage limit curve 8 7 Switching cycles AgSnO 0 0, 0, 0, 0,8 1,0 1, 1, 1, 1,8,0 M000_d Switching capacity P[kVA] OA 8: Contact service life (at t u = 0 C) Switching cycles 7 7, 7, 0, 0 0 0 0 80 0 C Ambient temperature OA 7, OA 8: Operating voltage limit curve P max. for OA 71/7 OW model OA model 0 0, 1,0 1,,0,, Switching power P[kVA ] OA 7, OA 8: Contact service life (at t u = 0 C) M07 a Switching voltage U [ V] 0 0 180 0 0 0 0 0, 0, 0, 0,8 1 8 M001 Switching voltage U [ V ] 0 00 10 0 7 0 0 0 0 1 Imax for OA 71/7 0, 0, 0,7 Switchingcurrent I [A] 7, 1 M07 a Switching current I --- Safe switch off, no standing arc max.1 switching cycle/s [A] Safe switch-off,no standing arc max.1 switching cycle/s Arc extinguishing during switchover time of contacts, max. 1 switching cycles/s OA 8: Limit curve for arc-free operation (at t u = 0 C) OA 7, OA 8: Limit curve for arc-free operation (at t u = 0 C) Characteristic is valid for: - inductive load - capacitive load The actual number of cycles with reactive loads n blind is can be calculated as follows: n blind = n ohmic x F OA 8, OA 7, OB 9: Reduction factor for inductive loads 1.0.1 en / 7

Characteristics UB UN T Spmax =f( U,T,I B ) U K at 0% ED 1, 1, 1,1 1,0 0,9 0,8 0,7 1 I=I K Kmin I K=A I K=1A M07_a U Bmin =f(t Sp ) 1 Example: * for max. voltage or max. coil resistance (at t e >s... 0% ED) known: T U =0 C, I K =A requested: U Bmax? solution: U Bmax = 1,0xUN known: I K =I Kmin, U B =1,1UN requested: TU zul? solution: TU zul = C * for operating behaviour of the relay known: relay "cold", i.e. T Sp=T U [with T U =0 C] requested: U Bmin? solution: U Bmin =0,77xUN 0, 0 0 0 0 80 0 T U [ C] known: Relais "hot", i.e. T Sp >TU [with TSp -> C but according to 1 or TUca. 0 C) requested: U Bmin? solution: U Bmin =0,98xUN 0 0 0 0 80 0 0,9 1 1,1 1, 1, 1,9 I K = continuous current R W = resistance in hot state R N = nominal coil resistance T U = ambient temperature T Sp = actual coil temperature U B = opertating voltage applied U N = nominal voltage T Sp[ C] RW RN OB 9: Operating voltage limit curve Switching cycles n ohmic 7 0 1 Swichting power P[kW] M08_a Switching voltage U [V DC] 0 00 0 80 0 0 0 0 1,1,,, 1 1 Switching current I[A DC] M09_a DC-drive AC-drive Comment Graph is valid for: - clear resistive load (cos =1) -AC 0V OB 9: Contact service life Contact distance > 0, mm Grapic only for resistive DC-loads at max.1 switching cycle/s - safe switch-off -no standing arc At voltages <DCV max. 00 W can be switched. OB 9: Limit curve for arc-free operation (at t u = 0 C) 1.0.1 en / 7

Standard Variants OA 8 Nominal voltage Resistance at Voltage range AgSnO 0 C + µm Au DC V DC V W.1.0.1.1.7... 9. 0 91 71 91 91.... 11.0 70 9 7 9 9 1 9.0....0 70 9 7 9 9 0 1.0....0 80 98 78 98 98 18.0....0 1 0 9 7 9 9 8... 89.0 00 9 7 9 9 0.0... 1.0 80 9 7 9 9 1 80.0... 190.0 0 000 97 77 97 97 Nominal voltage 1) DC V OA 7, OA 8 Voltage range V Resistance at 0 C W OA 7.11 AgSnO OA 8.11 + mm Au OA 7.11.... 1. 70 81 881 01 1 8..... 80 8 88 0 1.....0 0 8 88 0 0 1.0....0 70 8 88 0 1.8....8 1 0 8 88 0 8..... 00 89 889 070 0.0... 1.0 7 000 80 890 071 1 77.0....0 000 81 891 07 Nominal voltage Voltage range ) Resistance at AgSnO DC V AC V V W (±%).01/.11/.01/.11/.8.... 8 91 901 91 911 1 9.... 1. 10 9 90 9 91 1 1... 1. 0 9 90 9 91 0 1... 9 90 9 91 19..... 7 9 90 9 91 1 9.... 1. 9 80 9 91 19..... 0 9 90 9 91..... 80 9 90 9 91 0 18... 000 9 90 9 91 OB 9 1.0.1 en / 7

Ordering Example Accessories OA 8. / _ OA 7. / _.1 = changeover contacts.0 = NO contacts.0 = NC contacs Socket ET 11.01 Fixing clip Functionmodule Socket OB 9. / Accessories.01 = 1 NO contact.11 = 1 changeover contact.01 = NO contact.11 = changeover contact Socket for DIN-rail incl. fixing clip Socket ET 11.0 Fixing clip M90_a Socket Socket ET 11.07 Fixing clip Functionmodule Functionmodule Socket Function module ET11.91: DC V, with free-wheel diode and green LED Article number 0088 ET11.911: DC V, with free-wheel diode and red LED Article number 00909 M89_a M88_a ET11.91: AC/DC V, with varistor and green LED Article number 009 ET11.9: DC 0 V, with free-wheel diode and red LED Article number 00 M79_a Screw terminals Cage clamp terminals Socket incl. fixing clip ET 11.01: with screw terminals Article number 0071 ET 11.0: with screw terminals and safe separation Article number 0097 ET 11.07: with cage clamp terminals Article number 00970 Socket for DIN-rail incl. fixing clip incl. safe separation between ciol and contacts according to DIN EN 097-1, DIN EN 1, DIN EN 00 Degree of protection Terminals: IP 0 DIN EN 09 Terminal designation: DIN EN 000 Wire connection ET 11.01, ET 11.0: 0.1.... mm solid (1-0 AWG) 0.1.... mm stranded (1-0 AWG) 0.1... 1. mm sleeved end (1 - AWG) ET 11.07: x (0.... 1.) mm solid (1 - AWG) x (0.... 1.) mm stranded (1 - AWG) x (0.... 1.) mm sleeved end (1 - AWG) Wire fixing: box terminals or cage clamp terminals Mounting: DIN-rail DIN EN 071 Weight: ET 11.01: ET 11.0: ET 11.07: approx. 8. g approx.. g approx. g M79_a Dimensions Width x height x depth: ET 11.01: ET 11.0: ET 11.07: 1.8 x 7 x 9 mm 1.8 x 7 x 7 mm 1.8 x 97 x 7. mm 1.0.1 en / 7

E. DOLD & SÖHNE KG D-7811 Furtwangen PO Box 11 Telephone (+9) 77 / -0 Telefax (+9) 77 / - e-mail: dold-relays@dold.com internet: http://www.dold.com 1.0.1 en / 7