The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012

Similar documents
The HOIS recommended practice for in-service computed radiography of pipes

Pre Conference Workshop on Advanced Digital imaging

Film Replacement in Radiographic Weld Inspection The New ISO Standard

Computed Radiography

» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Examination of Pipe Welds by Image Plate Based Computed Radiography System

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

Experiences of users in Digital Radiography

Radiographic testing: Increased detection sensitivity using optimum source to object distance

ON THE WAY TO DIGITAL RADIOGRAPHY

5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

Fig.2: Scanner VistaScan for image plates

Projection Radiography. application on stream

Performance evaluation of a photon counting detector for high energy NDT applications

Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

ScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR)

THE CR SPECIALISTS HD-CR CR 35 NDT

Welding Inspection Non-Destructive Testing Course Reference WIS 5

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Introduction To NDT. BY: Omid HEIDARY

Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers

Phased Array UT Application For Boiler Tube Inspection in Manufacturing And In-Service Anandamurugan S 1, Siva Sankar Y 2

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS

Advanced Digital Radiography for Field NDT

ISO INTERNATIONAL STANDARD

17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

Digital Profile Radiography Practical uses and limitations

Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography

DACON INSPECTION SERVICES. Computed RADIOGRAPHY

Digital Profile Radiography Practical uses and limitations

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 2: X- and gamma-ray techniques with digital detectors

Strategies for Film Replacement in Radiography - a comparative study -

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY

Digital Radiology with Photon Counting Detectors

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

Part 3: Image quality classes

Determination of Optimum X-Ray Tube Output Parameters kv and ma for Digital Radiography Testing of Welded Tubes

RELIABILITY OF GUIDED WAVE ULTRASONIC TESTING. Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

Real Time Linear Array Imaging. Brian Caccamise

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded

Digital Radiography for the Inspection of Small Defects

This document is a preview generated by EVS

Dürr NDT GmbH & Co. KG Höpfigheimer Straße 22 D Bietigheim-Bissingen Germany. Contract No. BAM ZBA Dürr

UNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY

Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications

Advancements In Digital Radiography: CR, DR, and DICONDE

RADIOGRAPHIC EXAMINATION PROCEDURE

New Developments in Automated Inspection for Corrosion under Insulation

Digital Radiography Systems Techniques and Performance Evaluation for Space Applications

A Modified Detectability Criterion for Conventional Radiography Simulation

Overview. Corrosion detection improvement of oil and gas pipelines with industrial radiography method by using image processing.

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS. Bernhard REDMER

NDT-PRO Services expands service offering

Engineering Policy & Procedure

Digital Radiography : Flat Panel

Radiographic Testing (RT) [10]

Research Article Digital Radiography Using Digital Detector Arrays Fulfills Critical Applications for Offshore Pipelines

The field deployable digital X-Ray solution for weld inspection in O&G

Mobile digital radiography system for nondestructive testing of large diameter pipelines

Center for Nondestructive Evaluation 304 Wilhelm Hall Iowa State University Ames, Iowa 50010

Hardware for High Energy Applications 30 October 2009

Gamex Lite 3.0 Program description and operating manual

Digital Radiography and its Advantages in Field NDT Inspections Today

COMPUTED RADIOGRAPHY THE STATE OF THE ART

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography

SINCE2011 Singapore International NDT Conference & Exhibition, 3-4 November 2011

Amorphous Selenium Direct Radiography for Industrial Imaging

The Battle of Carbon Steel

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

Pipeline Technology Conference 2010

PAUT as Tool for Corrosion Damage Monitoring

Digital Radiography, Flexible Risers

Digital Detector Array Image Quality for Various GOS Scintillators

CARESTREAM INDUSTREX Digital Imaging Plates

FOCUS. Quick Industrial X-ray Testing Without Intermediate Data Carriers of Information. by V.A. Troitskiy

Ray Detection Digital Image Quality and Influential Factors

digital radiography r High-energy DT Applications lior Pick, Ron Pincu and Ofra Kleinberger over film radiog- p P This advanced

IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison

3/31/2011. Objectives. Emory University. Historical Development. Historical Development. Historical Development

Visibility of Detail

Gamex CR 2.0 Program description and operating manual

Australian Standard RADIOGRAPHY OF WELDED BUTT JOINTS IN METAL. Part 2 IMAGE QUALITY INDICATORS (IQI) AND RECOMMENDATIONS FOR THEIR USE

NEW POSSIBILITIES OF RADIATION CONTROL OF QUALITY OF WELDED JOINTS

10/3/2012. Study Harder

PRACTICAL ENHANCEMENTS ACHIEVABLE IN LONG RANGE ULTRASONIC TESTING BY EXPLOITING THE PROPERTIES OF GUIDED WAVES

In-service inspections for primary coolant circuit components of light water reactors Part 6: Radiographic testing

Spokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales

Computed Radiography of Resistance Temperature Sensor for Indian PHWR

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

CARESTREAM INDUSTREX Digital Imaging Plates

Half value layer and AEC receptor dose compliance survey in Estonia

Transcription:

The HOIS recommended practice for in-service computed radiography of pipes WCNDT 2012, Durban, SA. April 2012 Dr Stephen F Burch, ESR Technology, Oxfordshire,UK steve.burch@esrtechnology.com ESR Technology Ltd

HOIS Joint Industry Project (JIP) HOIS is a well established JIP & forum for improved NDE in the oil and gas industry Focus on upstream applications Members comprise: Oil and Gas producers NDT service/vendor companies NDT equipment vendors A regulatory authority (UK HSE) Managed by ESR Technology Now has 39 members More information from www.hois2000.com ESR Technology Ltd Slide 2

Computed Radiography (CR) in the oil and gas industry In-service inspection of pipes Flaws of interest generally corrosion & erosion Can be internal or external Corrosion product often present for external flaws External insulation often present Drivers: No need for dark room/chemical disposal required for film Reduced exposure times compared with film Ease of dimensional measurements Most widespread application is combination of tangential & double wall double image (DWDI) Can then measure through-wall extent of corrosion ESR Technology Ltd Slide 3

Potential issues for in-service CR No relevant international standards Lack of quality control IQI values not specified for in-service inspection Variable exposures, source positioning, source selection Subjective assessment of image quality Lack of understanding of CR equipment by users CR equipment more complex than film! Range of different scanners and imaging plates Effects of different user selectable parameters not well understood Gain/sensitivity Pixel size Other parameters (e.g. scanning speed) Not clear what is needed to achieve acceptable image quality ESR Technology Ltd Slide 4

HOIS Project on CR recommended practice for ISI Early HOIS sponsored blind trial of CR for ISI gave unexpectedly poor results (2003) Follow-up showed this to be due to limitations in procedures used, not the inherent capabilities of the equipment. Productive collaboration with CR experts at BAM, Berlin. Professor Uwe Ewert & Dr Uwe Zscherpel Several practical CR trials to develop and validate the recommended practice HOIS Recommended Practice Published in January 2010 available for download from www.hoispublications.com Now being progressed to form basis of pren 16407 ESR Technology Ltd Slide 5

HOIS CR Recommended Practice: Scope For wall loss in-service inspection of pipes only Corrosion/erosion flaws NOT cracks Techniques covered: DWDI and/or tangential radiography DWSI Two quality classes Standard quality Higher quality for more demanding applications such as inspection of fine pitting ESR Technology Ltd Slide 6

HOIS CR recommended practice - key sections Radiation Sources Focus on isotope sources as these are nearly always used for in-service inspection Types of source Source selection Size and strength of sources Recommended Source to Detector Distances DWSI DWDI Tangential Inspection CR Image Quality criteria Normalised Signal-to-noise ratio (SNR_N) Target single-wire IQI values Guidance on exposure times ESR Technology Ltd Slide 7

Isotope source selection for tangential radiography Limits are similar for CR & radiographic film Example: 2" sch 80 pipe has a max path of 35mm (much greater than twice the wall thickness) Isotope source Approximate maximum tangential path (mm) Standard quality (for generalised wall loss) Higher quality (for pitting flaws) Se 75 55 40 Ir 192 85 60 Co 60 140 100 ESR Technology Ltd Slide 8

Source to detector distances (SDD) for DWDI Setting the SDD involves a trade-off between image sharpness and exposure time For wall-loss applications, image unsharpness can be larger than for weld radiography After much discussion, recommend distances based on geometric unsharpness, U g, projected onto a plane on the source side of pipe Standard quality: U g = 0.6 mm Higher quality: U g = 0.3 mm Above values in reasonable accordance with current practice SDD for higher quality is twice the SDD for standard quality ESR Technology Ltd Slide 9

CR image quality With CR, apparently acceptable images can be obtained with very short exposure times But these images can be noisy and may not have acceptable sensitivity for flaw detection and reliable sizing Objective measures of CR image quality are needed to ensure adequate flaw sensitivity CR image quality measures considered: Image signal to noise ratio CR image grey level (target grey-level values) Wire IQIs ESR Technology Ltd Slide 10

Image quality measures: Signal-to-noise ratio Concept of normalised signal-to-noise ratio (SNR_N) given in EN 14784-1 & 2 Can be used to measure objectively the quality of CR images Select areas for analysis with no significant image variations caused by the component (e.g. pipe centre line avoiding any areas of corrosion) Advantages: Provides quantitative measure of CR image quality Can be applied to tangential radiography (using pipe centre line or free beam areas) Limitations: Does not take account of radiographic contrast of CR image Needs measurement of basic spatial resolution (BSR) of IP/scanner using duplex wire IQIs ESR Technology Ltd Slide 11

HOIS CR recommended practice SNR_N targets Double wall techniques: Standard image quality: SNR_N 50 on pipe centre-line Similar to IP5 film class, e.g. D7 film with density = 2 Higher image quality: SNR_N 80 on pipe centre-line Similar to IP3 film class, e.g. D4 film with density = 2 Tangential techniques Follow above if pipe centre line available for SNR_N measurement Use free beam if not, but aim for higher values ESR Technology Ltd Slide 12

SNR_N (fitted) SNR_N as a function of exposure for different scanners/ips 140 Wide variations in exposure times need to achieve specified Comparison of SNR_N fitted curves values for different IPs 120 100 High sensitivity and low levels of fixed pattern noise 80 60 40 20 Low sensitivity and/or high levels of fixed pattern noise 0 0 10 20 30 40 50 60 Exposure (Ci.Min @ 500mm) ESR Technology Ltd Slide 13

Image quality measures: Single-wire IQIs Used as standard for radiography of welds Can also be applied for in-service radiography of wall-loss flaws Advantages: Easy to apply. No special software needed Takes account of radiographic image contrast Issues: Not appropriate for tangential radiography IQI may obscure flaws of interest Ensure that IQI is placed centrally in image not right at edge Target values need to be established experimentally Some subjectivity in assessment of wire values ESR Technology Ltd Slide 14

Target values for IQI wires for wall loss CR Experimental trials to determine IQI wire numbers for CR images collected in accordance with the recommended practice Number of IQI wires visible will depend on: Image quality class (standard/high) Wall thickness of pipe Presence of any liquid product in pipe Source used (Ir 192, Se75 etc) Large number of experimental measurements needed ESR Technology Ltd Slide 15

IQI value W Trial results for DWDI IQI values for Ir 192 Apply to empty and product filled pipes Note experimental scatter. RP uses solid lines shown 15 14 13 12 11 10 DWDI - Ir 192 DWDI Bergen Oct 08 IPC2/CR100 DWDI IPC2/CR50P NDT Services DWDI Bergen Feb 08 IPC2/CRX Tower DWDI Bergen May 09 ST6/Fuji DWDI Water filled Bergen Feb 08 IPC2/CRX Tower DWDI Water filled Bergen Oct 08 IPC2/CR100 DWDI Water Filled Bergen May 09 ST6/Fuji & HD CR 35/White DWDI Ir 192 Target values DWDI HIGHER Bergen Feb 08 IPS/CRX Tower DWDI HIGH Bergen Oct 08 IPS/CR50XP DWDI HIGHER Bergen May 09 HD CR 35 White IP DWDI Water filled HIGHER Bergen Feb 08 IPS/CRX Tower DWDI Water filled HIGH Bergen Oct 08 IPS/CR50XP DWDI Ir 192 High Target values EN1435 (DWDI) 9 8 7 6 5 0 10 20 30 40 50 60 Equivalent steel total penetrated thickness (mm) ESR Technology Ltd Slide 16

Validation of RP repeat blind POD trial Original CR POD trial in 2003 gave comparatively poor performance POD 60% Procedure used was not fully developed for the DWDI application Repeat CR trial on same specimens in 2007 in accordance with HOIS CR recommended practice Used DWSI to detect flaws (quicker than DWDI) POD 98% Clear improvement ESR Technology Ltd Slide 17

Recent HOIS CR activities Further CR trials for in-service inspection External corrosion scabs highlights limited coverage of tangential technique (shots at 5º increments needed to find deepest point) Effects of dry pipe insulation Some initial investigations of CR for weld inspection Main interest of members is for site radiography of new welds Use isotope sources and relevant double-wall techniques Significantly higher quality required Some interest in DR flat panels for site radiography Near real-time imaging Shorter exposure times than for CR ESR Technology Ltd Slide 18

CR pros and cons for in-service inspection Main CR advantages Avoids need for dark room and chemical disposal Re-usable IPs (cost savings) Adequate image quality for erosion/corrosion On-screen measurements of dimensions (tangential) Greater exposure tolerance than film (higher dynamic range) Electronic images can be readily transmitted and stored Potentially shorter exposure times (often not a significant factor) Main CR limitations High capital cost of equipment High complexity of equipment compared with film (many user adjustments effects not well understood) Scanner/IP related large-scale non-uniformities in image brightness (e.g. banding/shading) Limits to achievable SNR due to IP/scanner induced fixed pattern noise IP's can be damaged quite easily and become "used" (scratches etc) ESR Technology Ltd Slide 19

Conclusions There is a need for improved quality control for inservice inspection of wall-loss using CR A recommended practice has been developed by the HOIS JIP: Download from www.hoispublications.com Draft EN standards pren16407-1 & -2 have just been issued for public comment in EU. ESR Technology Ltd Slide 20

Acknowledgements The HOIS JIP is thanked for funding this work Members of the HOIS JIP are thanked for useful discussions and feedback during the preparation of the CR recommended practice The following are thanked for hosting, supply of equipment and participation in the HOIS CR experimental trials Aker Solutions, AGR EMI team, NDT Services DÜRR NDT, FujiFilm, GE Inspection Technologies Malcolm Miller, Shell for leading the second blind trial ESR Technology Ltd Slide 21

Thank you for your attention Any questions? ESR Technology Ltd Slide 22

Thank you for your attention Any questions? ESR Technology Ltd Slide 23