NV-ET1801 or NV-ER1808i or. NV-ER1816i

Similar documents
10/100 PoE+ NV-ER1808i or. NV-ER1816i

Data Sheet. Four Port PoE+ Receiver Model NV-ER1804. Application Example: Features:

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i

Sixteen Port PoE+ Receiver Hub Model NV-ER1816i

NV-EC1701. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

100 BaseT transmission; Network speeds up to 93 Mbps*; Up to 8,000ft (2,500m)*

NV-EC1701U. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

Model NV-ET1804 TBus Four Port PoE+ Transmitter with Four PoE, PoE+, or High Power PoE Ports

Model NV-ER1804 TBus Four Port Receiver

NV-EC1701U. Ethernet over Coax Transceiver (+1) (+44) (0) Model NV-EC1701

Model NV-EC1701 EoC Ethernet over Coax Transceiver with PoE, PoE+, or High Power PoE

Model NV-ER1808i TBus Eight Port Receiver Hub FRONT

Model NV-EC1701U Eo2 TM Ethernet over 2-Wire Transceiver with PoE, PoE+, or High Power PoE

Model NV-ER1808i TBus Eight Port Receiver Hub

Model NV-ER1816i TBus Sixteen Port Receiver Hub

INSTALLATION GUIDE. 8 Port IP Video Extender Over Coax With Built-In Gigabit PoE Switch

Who is NVT? Consistent Stock Availability. Fast and Reliable Delivery Capability. Limited Lifetime Warranty and Advance Replacement

Network Video Technologies H Y B R I D V I D E O P R O D U C T S O L U T I O N S

MATERIAL SPECIFICATIONS FOR WIRELESS LINK

Airmux-400 Broadband Wireless Multiplexer

INSTALLATION GUIDE ET1551U. IP Video Camera Over Single Twisted Wire Ethernet Extender with EtherStretch. Description

NITEK INSTALLATION GUIDE EL1500CW. Outdoor IP Cameras Over Coax Network Extender PoE Injector. Description EUROPE USA

Power Over Ethernet (PoE) Part 1 What is it?, How is it used?, and Lightning Field Failure Analysis

CCTV NETWORK SOLUTIONS

4 Channel Security Hubs

IP CABLING TRANSMISSION ITEM NO.: IP07M Chainable IP Extender with Power over Coax/Two Wire

Multi-Channel AVC Active Receiver Hubs Installation Sheet

Installing the IPS 4240 and the IPS 4255

RuggedNet GPoE+/Si Unmanaged 4 and 8-Port PoE/PoE+ Switch. User Manual. 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949)

MONITOR BRACKETS CCTV SYSTEMS. BT7510S Ex GST Inc GST. BT7511S Ex GST Inc GST. BT7512S Ex GST Inc GST. BT7518S Ex GST Inc GST. BT7513S Ex GST Inc GST

Artistic Licence. Art-Switch PoE4. User Guide. Art-Switch PoE4 User Guide. Version 1-3

SEL-3060 Ethernet Radio Data Sheet

CM /100/1000BASE-T

Call For Interest PoE- plus. Chris Di Minico MC Communications

MUSE : IP+POWER+RS-232 Transmitter

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

RADWIN 2000 PORTFOLIO

Product catalog. May Where any application finds its wireless solution L E X Y C O M T E C H N O L O G I E S, I N C

RADWIN 2000 Portfolio. Built for Backhaul

Emergency PHM Series. Emergency PowerHUBB Node - Master/Control/Tunable White. Dimensional Data. Ordering Information (Example: PHM4PC EM)

System Specification. BreezeACCESS TM EZ. January 2008

Application & Solution Guide

Airmux-400 Broadband Wireless Multiplexer (Ver. 2.4)

Specification Sym Notes Minimum Typical Maximum Units 900 MHz Operating Frequency Range MHz

Airmux-200 Wireless Broadband Multiplexer

Smart Metering Modem Solutions BROADBAND

10/100BASE-TX to 100BASE-FX. Fast Ethernet Media Converter. Quick Installation Guide

SC-IPT3001E, SC-IPR3001E User s Manual

The I-2532 CAN to Fiber Converter

Specifications subject to change without notice Heartbeat of the Smart Grid

RuggedNet GPoE+/Mi Managed 4 and 8-Port PoE/PoE+ Switch. Quick Start Guide. 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949)

OmniConverter GPoE+/SX. User Manual. 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 2

PowerShare PS604A adaptable power amplifier

Pro Range SIL PICO SIL MICRO SIL LITE SIL MAX SIL BASE. 5.1GHz 5.8GHz Wireless Links

Active UTP Transceiver Hub Installation Guide

Airmux-400 Specifications

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

FSW-1650 FSW User Manual. 16/24-Port 10/100 Rackmount Switch

ST-CCTV-VBAC8 8-Channel Active UTP Video Receiver

3 GHz Carrier Backhaul Radio. Model: AF-3X. Tel: +44 (0) Fax: +44 (0) LINK GPS MGMT DATA DATA

LAN/Length Cable Tester TCT-2690 Pro

FL WLAN 24 AP XDB and RAD XDB

Datasheet. Licensed Backhaul Radio. Model: AF-4X. Up to 687 Mbps Real Throughput, Up to 200+ km Range

Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual

5/8/16/24 Ports. Fast Ethernet Switch. User s Guide VER:1.0

ARCO 400. Technical Data

10/100Base. 100Base-FX Switching Converter. User s Manual

Selection guide. Communication accessories. Communication accessory selection guide. Characteristics

Spring Return DuraDrive Proportional Actuator

LongReach II Active CCTV Receiver Hub [8P], [16P] Installation Guide

EM 6000 EM 6000 DANTE True bit diversity receiver

FTT-10A Free Topology Twisted Pair Transceiver Model 50051

Portable Multi-Channel Recorder Model DAS240-BAT

Hybrid Bi-SectorTM Array

Side view View from below Rear view

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual

CATALOG. Network Access & Connectivity

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Nodes, Wall Switches, Sensors & Peripherals Data Sheet

MediaMatrix X-Frame 88

[ tima-datasheet-en v11.1 ]

LT-800 Stationary Transmitter

ST-CCTV-VBAC16 16-Channel Active UTP Video Receiver

Gemini Express Fiber Multiplexer User s Guide

satech SynchroStar GPS 200 Series

Trio Q Data Radios. Licensed UHF Ethernet and Serial Data QR450

Dante Kit MEG basic

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

Hybrid Bi-SectorTM Array

2.4GHz/5GHz 300Mbps Outdoor CPE

Airmux-400 Broadband Wireless Multiplexer (Ver )

(ES) Equipements Scientifiques SA - Département Réseaux sans fil rue de Buzenval BP Garches Tél Fax.

CMC 256plus - protection relay test set and universal calibrator

Hybrid Bi-SectorTM Array

t-series The Intelligent Solution for Wireless Coverage and Capacity

RADWIN 2000 PORTFOLIO CARRIER-CLASS POINT-TO-POINT SOLUTIONS. RADWIN 2000 product portfolio

Non-Spring Return DuraDrive Modulating Actuator

Active CCTV Receiver Balun Installation Guide

MultiNet. Instruction Manual. Digital Energy Multilin. Serial to Ethernet Converter. Manual P/N: A2 Copyright 2009 GE Multilin

Wireless Equipment. Ubiquiti 5Ghz NanoStation Wireless Access Point WT5-UNS...2. Ubiquiti 5.8GHz 25dBi PowerBeam AC Antenna WT5-UPBAC4...

Transcription:

Data Sheet Application Example: Link Quality Link Data 1 PoE Data 2 PoEData 3 PoE Data 4 PoE NV-ET1804 Ethernet Transmitter 328ft ( 100m) NV-ET1804 any wire NV-ET1801 or NV-ER1804 or NV-ER1808i or NV-ER1816i 328ft ( 100m) Power Supply Switch or Router LAN/WAN Hybrid DVR or NVR Monitor Features: 100 BaseT transmision; Network speeds up to 150Mbps*; Up to 8,000ft (2,500m)* Powers up to four PoE, PoE+, or High Power PoE cameras (or other PoE devices), up to 50 watts* Use with any TBus Receiver One TBus receiver at the network-end can support multiple remote Transmitters/IP cameras 56 VDC is distributed over the TBus to all connected equipment Easy configuration, no PC required Transparently supports all networking protocols (UDP, TCP/IP, HTTP, Multicast*, etc.) 128-bit AES encrypted transmission; Built-in transient protection Limited lifetime warranty The NVT TBus is a compact media converter that allows 10/100 BaseT Ethernet and PoE+ power to be transmitted using virtually any kind of cable. These devices are often used in legacy installations where existing cable is re-deployed as part of an upgrade to IP cameras. 56 VDC class 2 power is delivered to one transceiver, which distributes it to multiple* remote transmitters, and their PoE, PoE+, or High Power PoE cameras*. These transceivers are extremely simple to use, with no IP or MAC addressing required. Status LEDs indicate power, Ethernet/PoE, and TBus connectivity/activity/quality. They are backed by NVT s award winning customer support and limited lifetime warranty. * Distance and number of devices supported may be lower due to power supply capacity and wire voltage-drop. See Wire Distance Charts on page 4. Aggregate TBus bandwidth is dynamically allocated (shared based on traffic), and decreases with wire distance. See Wire Distance Chart on page 5. Multicast requires an IGMP Querier, either in a network switch, or within the NV-ER1808i or NV-ER1816i Receiver Hub. High bandwidth streaming devices (>15Mbps) that employ unusually chatty protocols (TCP/IP, TFTP, etc.) are not recommended. Use RTP/UDP instead. Page 1 of 5

R J 4 5 E T H E R N E T I N T E R FA C E S (4 each ) Connectivity: PoE Power: Protection: Wire type: Distance: T B u s L I N K I N T E R E R FA C E Connectivity: Wire type: Impedance: Topology: Data throughput: Latency: Wire distance: 10/100/1000 BaseT IEEE 802.3ab auto-negotiation, auto MDI / MDX crossover This Power Sourcing Equipment (PSE) detects and supports Powered Devices (PDs) that are compatible with IEEE 802.3af or 802.3at, or PDs that draw up to 50 watts. For maximum power distance, appears on all eight RJ45 pins*. Industrial transient protection Thermistor current protection or better up to 328 feet (100m) BNC or RJ45 Coax, single- or multi-pair UTP, 18/2, or STP wire 25 to 100 Ω Bus architecture supports star, daisy-chain, or any combination. One control-room Receiver may support multiple remote TBus Transmitters. 150 Mbps total network bandwidth* with dynamic bandwidth allocation 3 ms Up to 8,000 feet, 1.5 miles (2.5 Km)* Transmission technology: IEEE 1901 Encryption: 128-bit AES, through one-button Joining * I M P O R TA N T N O T E : Data rate, distance, and number of devices may be lower due to wire voltage-drop, power supply capacity, or signal attenuation. See pages 4 & 5. W A R N I N G : For safety, never use more than two power supplies within a TBus channel. Never use more than one 60 watt remote power supply on each TBus channel. R E G U L AT O R Y UL Listed to IEC/UL 60950-1 Complies with FCC part 15A limits W A R R A N T Y Limited Lifetime Technical Specifications Specifications subject to change without notice. L E D S TAT U S I N D I C AT O R S Power Flashes when initializing or Joining Link Quality Link Remote device detected Link NV-ET1804 Ethernet Transmitter Link Quality Green = good Amber = fair Red = poor M E C H A N I C A L / E N V I R O N M E N TA L Data 1 PoE Data 2 PoE Data 3 PoE Data 4 PoE Data Green = good Flashes with Data PoE Green = PoE device connected Body Dimensions: 6.00 in (152 mm) wide 1.39 in (35 mm) high 4.40 in (112 mm) deep excluding connectors Shipping weight: 1.20 lb (0.54 Kg) Operating / storage temperature: -40 F to 185 F (-40 C to +85 C) 20 to 85% relative humidity non-condensing Power consumption: 3W Generated heat: 10 BTU/hour Transient immunity: 5 x 20µS 3,000A, 6,000V ESD 20KV, 200pF P O W E R S U P P LY Power is usually supplied by the TBus Receiver. For optional supplemental local power, an additional class 2 power supply may be purchased. These supplies are external inline, with an IEC380-C14 power inlet and a 6 ft (1.18 m) line cord. Input voltage is 100~240VAC 50/60Hz. A molded P1J 5.5mm barrel connector provides a class 2 (SELV) regulated output. Model NV-PS56-60W: 56V 60W 4.90 in (124 mm) long 2.00 in (51 mm) wide 1.25 in (32 mm) high, 0.67 lbs (300 g) Model NV-PS56-90W: 56V 90W 5.77 in (147 mm) long 2.36 in (60 mm) wide 1.27 in (32 mm) high, 0.94 lb (430 g) Operating / storage temperature: -40 F to +185 F (-40 C to +85 C) 20 to 5% relative humidity non-condensing Transient Immunity: 5x20µS 3000A, 6000V ESD 20KV, 200pF Use only the power cord provided with the unit or equivalent UL approved type SPT-2, SVT, or SJT 18/3 AWG 100~240 VAC, 1 Amp 60 C max 15 ft (4.5 m) long. One end with IEC380-C13 appliance coupler and the other end with NEMA 1015P or equivalent for your country. Page 2 of 5

Product and Accessories Link Quality Link Data 1 PoE Data 4 PoE NV-ET1804 Ethernet Transmitter NV-ET1804: Four port transceiver only Data 2 PoEData 3 PoE NV-PS56-60W: power supply, 60 watts with IEC line cord NV-PS56-90W: power supply, 90 watts with IEC line cord Do not use with NV-ER1808i or NV-ER1816i NV-BNCT: BNC T adaptor NV-EC4BNC: 1:4 BNC splitter adaptor NV-BNCA: BNC Screw terminal adaptor NV-RJ45A: RJ45 Screw terminal adaptor NV-PC4PR: RJ45 Patch Cord, 4-pair 3 (1m) Page 3 of 5

Wire Type and Power Distance The distance capability of wire is dependant on its ability to deliver DC power, and separately, to deliver highfrequency data signals. The graph below shows maximum power delivery when using a 56V power supply. If you are locally powering your camera (or other remote device), then this graph does not apply. The graph on the next page shows the maximum data delivery rate. A Distance Calculator can be found at www.nvt.com. PoE devices require a minimum of 43V to operate. With a 56V supply, we have up to 13V of allowable voltage drop on the wire. The voltage will dip in proportion to the remote (camera) load. The graph below shows what PoE power distances are supported for various loads and wire types. Start with the camera wattage at the left. Sometimes IP cameras are listed as to their PoE Class rather than wattage. Now read over to the right until you find your kind of wire. Then look up (feet) or down (meters) to find your maximum distance. If your wire is not among the examples, simply measure its total resistance and find the value on the right side of the graph. The maximum supported wattage is on the left. Camera Wattage 50 W 40 W 30 W 25 W 20 W 18 W 15 W 12 W 10 W 8.0 W 6.0 W 5.0 W 4.0 W 3.0 W 2.5 W 2.0 W 98 ft 131 ft 197 ft 164 ft er PoE C 4 PoE C 2 PoE C 1 262 ft 397 ft 328 ft 984 ft 820 ft 656 ft 590 ft 492 ft Power Distance C 1 Pair Ca Pair Cat6 1 Pair 1,312 ft CATV AWG 2 1,968 ft 1,640 ft Cat6 4 Pair 4 Pair or 18/2 CATV 20 AWG WG ir 2,624 ft 3,936 ft 3,280 ft RG WG 9,840 ft 8,200 ft 6,560 ft 5,904 ft 4,920 ft RG-6 18 1 AWG RG59/U 20 AWG R WG RG59/U 22 AWG 13,120 ft RG-11 1 14 AWG 16,400 ft 3 Ω 4 Ω 6 Ω 7 Ω 9 Ω 11 Ω 12 Ω 14 Ω 16 Ω 19 Ω 21 Ω 23 Ω 24 Ω 28 Ω Total Wire Resistance 0 W 38 Ω 5,000 m 4,000 m 3,000 m 2,500 m 2,000 m 1,800 m 1,500 m 1,200 m 1,000 m 800 m 600 m 500 m 400 m 300 m 250 m 200 m 180 m 150 m 120 m 100 m 80 m 60 m 50 m 40 m 30 m Power Distance Page 4 of 5

Wire Type and Data Distance There are a wide variety of wire qualities, from copper-plated steel at the low end (CATV wire) to high performance low-loss pure copper. The graph below will help you to determine your data thoughput as a function of wire type and distance. A Distance Calculator can be found at www.nvt.com. 20,000 ft 10,000 ft 7,000 ft 5,000 ft 3,000 ft 2,000 ft 1,000 ft 700 ft 500 ft 300 ft 200 ft Typical Wire Distance RG-11 Coax RG-6 Coax RG-59 Coax UTP Cat 5 Shielded 18/2 Un-Shielded 18/2 7,000 m 5,000 m 3,000 m 2,000 m 1,000 m 700 m 500 m 300 m 200 m 100 m 70 m 50 m 100 ft 70 ft 50 ft 30 m 20 m 30 ft 150 140 120 100 80 60 40 Maximum Network Data Rate (Mbps) 20 10 m Page 5 of 5 Copyright 2014 NVT, Inc. 411-1804-1-A2