High power RF capabilities at Loughborough University

Similar documents
A miniature high-power pos driven by a 300 kv Tesla-charged PFL generator

A Low Impedance Marx Generator as a Test bed for Vacuum Diodes

6 - Stage Marx Generator

Generation of Sub-nanosecond Pulses

A multi-band printed monopole antenna

CHAPTER 1 INTRODUCTION. Pulsed power is a technology to compress the duration of time to generate peak instantaneous

Significant practical features of Tesla transformers

Improvements to Secondary Windings of Tesla Transformers

Magnetic coupling in Tesla transformers

INVESTIGATION OF A HIGH VOLTAGE, HIGH FREQUENCY POWER CONDITIONING SYSTEM FOR USE WITH FLUX COMPRESSION GENERATORS

High Power Pulsed Electron Accelerators Development for Industrial Applications

Cylindrical electromagnetic bandgap structures for directive base station antennas

UWB Type High Power Electromagnetic Radiating System for Use as an Intentional EMI Source

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

Design and Construction of a150kv/300a/1µs Blumlein Pulser

Optimizing the secondary coil of a tesla transformer to improve spectral purity

Design and construction of double-blumlein HV pulse power supply

Optically reconfigurable balanced dipole antenna

PHASING CAPABILITY. Abstract ARRAY. level. up to. to 12 GW. device s outpu antenna array. Electric Mode. same physical dimensions.

Bipolar modulation of the output of a 10-GW pulsed power generator

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

Wideband blade monopole antenna with sleeved coaxial feed

A notched hand wearable ultra wideband w printed monopole antenna for sporting activities

Progress In Electromagnetics Research, Vol. 119, , 2011

Investigating the effects of control lines on a frequency reconfigurable patch antenna

J.-H. Ryu Agency for Defense Development Yuseong, P. O. Box 35-5, Daejeon , Korea

PICO SECOND RISE TIME PULSE GENERATION USING MARX GENERATOR WITH PEAKING CIRCUIT

Reconfigurable antenna using photoconducting switches

RAVEN, A 5 kj, 1.5 MV REPETITIVE PULSER* G. J. Rohwein Sandia National Laboratories Albuquerque, New Mexico 87185

A NEW BROADBAND PULSED HIGH VOLTAGE MONITOR *

Antenna frequency and beam reconfliguring using photoconducting switches

A miniature reconfigurable printed monopole antenna for WLAN/WiMAX and LTE communication bands

CHAPTER 5 CONCEPT OF PD SIGNAL AND PRPD PATTERN

Solid State Modulator for Plasma Channel Drilling

Investigation of the effect of metallic frames on 4G eyewear antennas

High voltage charging system for pulsed power generators

System description 4. SERVICES ONSITE INSTALLATION AND TRAINING SYSTEM ACCEPTANCE MAINTENANCE... 7

Strathprints Institutional Repository

The Study of TVS Trigger Geometry and Triggered Vacuum. Conditions

AN ULTRA PORTABLE MARX GENERATOR-BASED SOLUTION FOR MIL STD 461 E/F RS-105 TESTING

Design and Implementation of 8 - Stage Marx Generator Used for Gas Lasers

Trees, vegetation, buildings etc.

High Voltage Engineering

Stitched transmission lines for wearable RF devices

Over-voltage Trigger Device for Marx Generators

PMT/UMT(275) Power Gap Description and Use Application Note

Fuse and Load Testing With Mid-Sized, High Energy Density Flux Compression Generators

Inductive power transfer in e-textile applications: Reducing the effects of coil misalignment

standard impulse voltage is represented by a double exponential wave [1-2] given by --- (1) Where α and β are constants in microseconds.

A 1.1 MV REP-RATE IN-LINE OUTPUT SWITCH AND TRIGGERING SYSTEM

I p = V s = N s I s V p N p

ANALYSIS OF A PULSED CORONA CIRCUIT

Design and operation influences regarding rise and fall time of a photoconductive microwave switch

High Voltage Generation

PARTIAL DISCHARGE MEASUREMENT

9. How is an electric field is measured?

Kent Academic Repository

Kent Academic Repository

Modeling of cable for measurements of small monopole antennas. Liu, L; Weng, YF; Cheung, SW; Yuk, TI; Foged, LJ

MAHALAKSHMI ENGINEERING COLLEGE

Compact Self-Loaded Marx Generator with Integrated Pulse-forming Line for an Ultra-Wideband Source

Kentech Instruments Ltd. CPS3/S pulser Serial No. J03*****

Basics of Partial Discharge. Prepared for 2015 Phenix RSM Meeting January 2015

Test and Measurement for EMC

High Votage Module AC/DC/Impulse Test System

Addressing the challenges of fabricating microwave antennas using conductive threads

Design and performance analysis of transmission line-based nanosecond pulse multiplier

Underwater Spark Sources: Some experimental information.

Experimental Observation of RF Radiation Generated by an Explosively Driven Voltage Generator

Peter, T; Sun, YY; Yuk, TI; Abutarboush, HF; Nilavalan, R; Cheung, SW

COMPACT FLASH X-RAY UNITS. Abstract

Lecture 5: High Voltage and Pulsed Power

Shielding Effect of High Frequency Power Transformers for DC/DC Converters used in Solar PV Systems

CHAPTER 2. v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES

Design of Kicker Magnet and Power Supply Unit for Synchrotron Beam Injection. BymWANG

Optically isolated, 2 khz repetition rate, 4 kv solid-state pulse trigger generator

Pulse Niru Company. General Catalogue.

An acoustic emission slope displacement rate sensor: Comparisons with established instrumentation

Dual-band MIMO antenna using double-t structure for WLAN applications

ABSTRACTS of SESSION 6

ULTRA FAST, HIGH REP RATE, HIGH VOLTAGE SPARK GAP PULSER

Multi-band material loaded Low-SAR antenna for mobile handsets

Directed Energy Weapons in Modern Battlefield

Development of a 300-kV Marx generator and its application to drive a relativistic electron beam

Description of HPM generation in atmospheric air using the laser and klystron terminology

Electromagnetic driven selfpiercing riveting of metal & composite sheets

DEVELOPMENT OF AN ULTRA-COMPACT EXPLOSIVELY DRIVEN MAGNETIC FLUX COMPRESSION GENERATOR SYSTEM

Design and Fabrication of Tesla Coil

Lightning transient analysis in wind turbine blades

Appendix B Experimental equipment and procedures

EMC standards. Presented by: Karim Loukil & Kaïs Siala

A dual-band antenna for wireless USB dongle applications

A3-308 HIGH SPEED GROUNDING SWITCH FOR EXTRA-HIGH VOLTAGE LINES

Advanced post-acceleration methodology for pseudospark-sourced electron beam

proton beam onto the screen. The design specifications are listed in Table 1.

Simplified, high performance transceiver for phase modulated RFID applications

HIGH POWER ELECTRONICS FOR ARMOR AND ARMAMENT

Lecture 36 Measurements of High Voltages (cont) (Refer Slide Time: 00:14)

List of Experiments. Exp. # Experiment Title Page #

High Rep-Rate KrF Laser Development and Intense Pulse Interaction Experiments for IFE*

Transcription:

Loughborough University Institutional Repository High power RF capabilities at Loughborough University This item was submitted to Loughborough University's Institutional Repository by the/an author. Citation: NOVAC, B.M., SMITH, I.R. and WHITTOW, W.G., 29. High power RF capabilities at Loughborough University. IN: IET Conference Publications on High Power RF Technologies, 26 February 29, 5pp. Additional Information: This is a conference paper. It is also available at: http://ieeexplore.ieee.org/. Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE. Metadata Record: https://dspace.lboro.ac.uk/2134/128 Version: Accepted for publication Publisher: IET / c IEEE Please cite the published version.

This item was submitted to Loughborough s Institutional Repository (https://dspace.lboro.ac.uk/) by the author and is made available under the following Creative Commons Licence conditions. For the full text of this licence, please go to: http://creativecommons.org/licenses/by-nc-nd/2.5/

HIGH POWER RF CAPABILITIES AT LOUGHBOROUGH UNIVERSITY B.M.Novac, I.R.Smith and W. Whittow Department of Electronic and Electrical Engineering, Loughborough University, Loughborough, Leicestershire LE11 3TU, UK Keywords: RF, HPM, HV Abstract Members of the Plasma and Pulsed Power Group at Loughborough University are engaged in several experimental activities related to the generation of high power radio frequency radiation. The paper reviews some of the more important projects that have recently been successfully completed. 1. Introduction Pulsed-power research at Loughborough University began some 25 years ago, with the production and measurement of blast waves from exploding wires and their use in impact studies of materials at high rates of strain. Subsequently, major facilities such as high-current capacitor banks and their ancillary equipment (ultra-high speed cameras, flash X-ray systems, digital oscilloscopes, etc) for both plasma and explosive device facilities have been introduced into what are now well equipped laboratories, with the aid of funding from the Engineering and Physical Sciences Research Council and government and industrial concerns. During the last decade one of the areas that has been given particular attention is that of compact and repetitive power sources for high power radiation generators. Various established pulsed power techniques have been adapted for use in these applications, and a number of novel projects have been successfully completed. Of particular note is a very high repetition rate system based on an extremely compact high voltage Tesla transformer. Closely related to this has been the production of a high frequency low inductance closing switch operating under corona stabilisation. A significant technical breakthrough was achieved with the demonstration of the first magnetically insulated transformer successfully produced world wide. In an alternative development, very high power systems based on exploding wires and transformer conditioning systems have been exploited in single-shot systems to drive high power microwave generators such as Vircators and other microwave sources. Related consultancy activities have seen designs produced for both large and small explosively-driven systems for driving single shot high power microwave loads. Blue skies research has been conducted on various novel techniques for microwave generation by unconventional means, with the most valuable result being a technique that produces ultra-wide band radiation from below 1 MHz up to at least 18 GHz. 2. Compact high-voltage pulsed power sources based on Tesla transformer technology Due to its simplicity in design, low cost and compactness, a Tesla pulse transformer is in some cases preferred to a Marx generator, with its inherent disadvantage of a slower voltage rise-time being mitigated by use of a pulse forming line (PFL) in conjunction with a high voltage fast spark gap (FSG) switch. Two Tesla transformer based systems were developed at Loughborough in the last five years: one built for and tested in common with Dstl and operating at an output voltage in excess of 5 kv and a much more compact unit with an output of up to 25 kv, developed for MBDA UK. A Tesla system is in principle based on the arrangement of Fig. 1 and it can conveniently be divided into an initial energy supply, a pulsed power generator, and the radiating elements. The initial energy is usually provided by a battery pack, followed by a 3 kv DC DC converter. The pulsed power generator consists of a capacitor bank (CB) made from 2 nf, 3 kv ceramic capacitors connected in parallel to the primary winding of the aircored pulse (Tesla) transformer through a short flat transmission line, with the circuit closed through a twoelectrode pressurized air spark gap (ASG) switch. The primary winding comprising a single-turn laminated copper strip 1 μm thick, sandwiched and heat bonded between two layers of Mylar-polyethylene laminate. The transformer secondary winding is usually made from a round copper conductor, wound on a conical polyethylene mandrel. A sectional view of the overall 5 kv pulsed power generator is given in Fig. 2 and a typical output voltage waveform in Fig. 3. If required, to sharpen the voltage pulse a coaxial PFL is integrated into the secondary circuit of the transformer, together with a SF 6 pressurized fast spark-gap switch (FSG). Fig. 4 shows the arrangement of the final field experiments and the radiated electric field at

Fig. 1. Schematic of a Tesla based pulsed power generator Fig. 2. Overall view of the 5 kv pulsed power generator Fig. 4. (upper) Open site measurement of radiated field. Insert shows arrangement for AD-7 D-dot sensor. (lower) Radiated field waveform (after ground corrections have been applied) at 1 m (solid line) and 15 m (dotted line) from source 5. (upper) A view of a CS-SG; (lower) voltage across switch at 2 khz PRF Fig. 3 Tesla transformer typical output voltage: (upper) 5 kv unit and (lower) compact 25 kv unit

Tesla primary circuit Magnetically insulated Tesla transformer PFL and switch Antenna Field injection system 1.9.8 B = 1.3 T.7.6.5.4 Vs (MV).3.2 Ia.1 B.1.2.3.4.5.5 1 1.5 2 time (μs) Fig. 6 (upper) Schematic of a multi-mv UWB source; (lower) 1 MV output demonstrated secondary winding flashover path lengtheners Fig. 7 (from upper to lower): primary circuit, Tesla transformer and HV secondary Fig. 8 (left) Vircator HPM generator; (right) overall view of complete system

Voltage [kv] H-field [A/m] 3 2 1-1 8.66 8.68 8.7 8.72 8.74 8.76 8.78 8.8 8.82 Time [µs] H-field 5-5 8.66 8.68 8.7 8.72 8.74 8.76 8.78 8.8 8.82 Time [µs] Normalized Power Spectrum of H-Field signal 1.5 Voltage over Vircator 1 2 3 4 5 6 7 8 9 1 Frequency [GHz] Fig. 9 (left) Arrangement inside the empty oil tank: high-voltage transformer, load and and MV probe. (right) Results from final system testing (from top to bottom): voltage pulse across vircator; microwave pulse; FFT spectrum of field signal 1 m and 15 m after numerically removing the ground reflected wave influence from the digitally recorded data, using appropriate values for the ground conductivity and permittivity. A figure of merit (FOM) of 124 kv is similar to or better than figures reported elsewhere for similar omni-directional EMP sources using only one-stage of pulse compression. The trend in repetitive pulsed power is nowadays towards higher peak power and higher repetition rates. One way to increase the repetition rate by improving the recovery time of the closing switch is to use the coronastabilisation technique. This process works in the presence of both a non-uniform electric field and an electronegative gas, with a highly non-uniform field achieved by designing the electrodes of the spark-gap with a needle-plane geometry. Under these conditions, breakdown of the spark-gap is preceded by a corona discharge in the high field region. Corona encircles the highly stressed electrode and locks the field around it to a corona onset value. Breakdown of the gap will only occur when sufficient space charge is generated to increase the electric field to at least a critical value. As it takes a significant time for such a process to develop, a full voltage recovery is achieved from the overall system and any pre-fire prevented. A schematic view of such a sparkgap is shown in Fig. 5 together with results obtained when operating at a PRF of 2 khz. 3. Magnetically insulated transformers Multi-MV magnetically insulated Tesla transformer (MITT) for radiation generators can have a relatively compact design that requires only a very low-energy capacitor bank, with the intense magnetic field that is responsible for the insulation being produced via a separate coil fed from an external source allowing microsecond time scale operation. A schematic of a powerful UWB source based on this concept is given in Fig. 6, where the injected field is obtained from a pulsed power supply derived from either an auxiliary capacitor bank, as described in this paper, or a compact and autonomous source employing an explosively-driven flux compression generator. A 1 MV Tesla transformer operating under magnetic insulating conditions has been successfully demonstrated giving the output voltage as shown in Fig. 6, with details of the arrangement presented in Fig. 7. It is believed to be the first working magnetically insulated megavolt-size Tesla transformer. A 1 MV UWB source based on this technology is presently under development. Future work is planned also for a 5 MV Tesla transformer using a FCG as an external autonomous power source for the injection field system estimated. Due to the much higher insulating field then available, around 14 T, the transformer volume is expected to remain much the same as that of the present 1 MV unit. 4. Powerful but simple pulsed power generators for single-shot HPM generators Modern applications of high-power microwave (HPM) generators require the development of compact pulsed power supplies capable of generating a voltage pulse up to and beyond 1 MV, and of sustaining the voltage for possibly up to 1 μs when a considerable microwave output is required. No simple solutions are available for this type of power source, and although megavolt Marx generators represent the most obvious answer, they are complex and have a high volume/weight ratio. An alternative is based on explosive magnetic flux compression generators (FCGs) when only a single-shot and possibly expendable system is required. To generate the high-voltage pulse, it is necessary to attach a conditioning unit incorporating an opening switch (OS) to the FCG output.

In cooperation with the Swedish Defence Research Agency (FOI), a power supply has been tested with a HPM source of the Vircator type (Fig. 8). The power generator for the system used a 7 kj/25 kv capacitor bank and an exploding wire array to generate a 15 kv voltage pulse in the primary circuit of a transformer. A pressurised SF 6 spark gap in the secondary circuit sharpens the high-voltage output, so that pulses approaching 5 kv and with a rise time well below 1 ns are generated on a 2 Ω high-power resistor, with the peak power in excess of 1 GW. The overall arrangement is shown in Fig. 8 and details of the HV transformer are given in Fig. 9. Experimental results are also presented in Fig. 9 from final testing of the system, where a reflex triode Vircator replaces the 2 Ω resistor. Measurements were made of the microwave emission using free-field sensors and the results obtained were similar to the microwave emission from the same Vircator even powered by a Marx generator at FOI. 5. Facilities and expertise available at Loughborough The work ongoing at Loughborough would not be possible without the availability of considerable supporting facilities and expertise. A range of explosive and capacitor bank pulsed power sources ranging in output from 1 ka to multi megampere currents are used in the laboratory and at remote firing sites. A wide range of opening and closing high-current, high-voltage switches is available, including rail gap switches rated at 1.2 MA. Numerous electromagnetic sensors and noise immune electro-optic and magneto-optic sensors have been developed in house. High-vacuum work can be undertaken, and the availability of high-speed cameras, mobile multi-flash x-ray equipment and high-performance oscilloscopes enables important events for be recorded in detail. Well-proven and highly detailed numerical techniques have been developed that have enabled major contributions to be made to the two-dimensional modelling on components under transient conditions. Recently, the introduction of finite-element multi-physical modelling has led to an even greater understanding of the underlying physics of both destructive and nondestructive experimentation. Loughborough also has several anechoic chambers that are used to measure and characterise antennas. A suite of commercial and in-house FDTD and TLM simulation software is available.