Exact Simultaneous Iterative Reconstruction Technique Algorithm-An Effective Tool In Biomedical Imaging

Similar documents
Improvement in Image Reconstruction of Biological Object by EXACT SIRT cell Scanning Technique from Two Opposite sides of the Target

DESIGN OF SLOTTED RECTANGULAR PATCH ARRAY ANTENNA FOR BIOMEDICAL APPLICATIONS

Interaction of an EM wave with the breast tissue in a microwave imaging technique using an ultra-wideband antenna.

A modified Bow-Tie Antenna for Microwave Imaging Applications

A Pin-Loaded Microstrip Patch Antenna with the Ability to Suppress Surface Wave Excitation

Non Invasive Electromagnetic Quality Control System

CHAPTER 2 MICROSTRIP REFLECTARRAY ANTENNA AND PERFORMANCE EVALUATION

WIRELESS power transfer through coupled antennas

Non resonant slots for wide band 1D scanning arrays

SAR Analysis in a Spherical Inhomogeneous Human Head Model Exposed to Radiating Dipole Antenna for 500 MHz 3 GHz Using FDTD method

Bayesian Estimation of Tumours in Breasts Using Microwave Imaging

Simulation Measurement for Detection of the Breast Tumors by Using Ultra-Wideband Radar-Based Microwave Technique

A Study On Preprocessing A Mammogram Image Using Adaptive Median Filter

Effect of Various Slot Parameters in Single Layer Substrate Integrated Waveguide (SIW) Slot Array Antenna for Ku-Band Applications

SCATTERING POLARIMETRY PART 1. Dr. A. Bhattacharya (Slide courtesy Prof. E. Pottier and Prof. L. Ferro-Famil)

Design of Microstrip Array Antenna for Wireless Communication Application

A. Kumar and S. Sharma Department of Electronics and Communication Engineering S. D. D. Institute of Engineering and Technology Barwala, India

Comparative Channel Capacity Analysis of a MIMO Rayleigh Fading Channel with Different Antenna Spacing and Number of Nodes

A method of controlling the base station correlation for MIMO-OTA based on Jakes model

Effect of Open Stub Slots for Enhancing the Bandwidth of Rectangular Microstrip Antenna

Mutual Coupling Reduction in Two- Dimensional Array of Microstrip Antennas Using Concave Rectangular Patches

APPLICATION OF SWEPT FREQUENCY MEASUREMENTS TO THE EMBEDDED MODULATED SCATTERER TECHNIQUE

MICROWAVE SUB-SURFACE IMAGING TECHNOLOGY FOR DAMAGE DETECTION

AN APPROACH TO DESIGN AND OPTIMIZATION OF WLAN PATCH ANTENNAS FOR WI-FI APPLICATIONS

FDTD CHARACTERIZATION OF MEANDER LINE ANTENNAS FOR RF AND WIRELESS COMMUNICATIONS

Harmful Effects of Mobile Phone Tower Radiations on Muscle and Bone Tissues of Human Body at Frequencies 800, 900, 1800 and 2450 MHz

Analysis and design of microstrip to balanced stripline transitions

Design and Development of Quad Band Rectangular Microstrip Antenna with Ominidirectional Radiation Characteristics

EFFECT ON PERFORMANCE CHARACTERISTICS OF RECTANGULAR PATCH ANTENNA WITH VARYING HEIGHT OF DIELECTRIC COVER

Design of a UHF Pyramidal Horn Antenna Using CST

MAGNETO-DIELECTRIC COMPOSITES WITH FREQUENCY SELECTIVE SURFACE LAYERS

UNIVERSITI MALAYSIA PERLIS

Performance Analysis of Different Ultra Wideband Planar Monopole Antennas as EMI sensors

DUAL-WIDEBAND MONOPOLE LOADED WITH SPLIT RING FOR WLAN APPLICATION

Postwall waveguide slot array with cosecant radiation pattern and null filling for base station antennas in local multidistributed systems

Switched parasitic antennas and cxontrolled reactance parasitic antennas: a systems comparison

Bandwidth Enhancement of Microstrip Patch Antenna Using Metamaterials

Study and Analysis of Wire Antenna using Integral Equations: A MATLAB Approach

Broadband aperture-coupled equilateral triangular microstrip array antenna

Impedance Modeling for a Unit Cell of the Square Loop Frequency Selective Surface at 2.4 GHz

MICROWAVE IMAGING TECHNIQUE USING UWB SIGNAL FOR BREAST CANCER DETECTION

SIERPINSKI CARPET FRACTAL ANTENNA ARRAY USING MITERED BEND FEED NETWORK FOR MULTI-BAND APPLICATIONS

Venu Adepu* et al. ISSN: [IJESAT] [International Journal of Engineering Science & Advanced Technology] Volume-7, Issue-4,

Image Simulator for One Dimensional Synthetic Aperture Microwave Radiometer

CIRCULARLY POLARIZED SLOTTED APERTURE ANTENNA WITH COPLANAR WAVEGUIDE FED FOR BROADBAND APPLICATIONS

International Journal of Electronics and Communication Engineering & Technology (IJECET), ISSN INTERNATIONAL JOURNAL OF ELECTRONICS AND

SAR REDUCTION IN SLOTTED PIFA FOR MOBILE HANDSETS USING RF SHIELD

Determination of Transmission and Reflection Parameters by Analysis of Square Loop Metasurface

Circularly Polarized Post-wall Waveguide Slotted Arrays

University of Bristol - Explore Bristol Research. Link to published version (if available): /LAWP

A MODIFIED FRACTAL RECTANGULAR CURVE DIELECTRIC RESONATOR ANTENNA FOR WIMAX APPLICATION

Performance Comparison of Micro strip Band pass Filter Topologies On Different Substrates

BANDWIDTH ENHANCEMENT OF CIRCULAR MICROSTRIP ANTENNAS

Precise measurement of complex permittivity of materials for telecommunications devices

A New Hyperthermia Scheme with a Cylindrical LHM Lens

Wideband Loaded Wire Bow-tie Antenna for Near Field Imaging Using Genetic Algorithms

DESIGN OF MID-BAND FREQUENCY PATCH ANTENNA FOR 5G APPLICATIONS

COMPUTATION OF RADIATION EFFICIENCY FOR A RESONANT RECTANGULAR MICROSTRIP PATCH ANTENNA USING BACKPROPAGATION MULTILAYERED PERCEPTRONS

Effects of Two Dimensional Electromagnetic Bandgap (EBG) Structures on the Performance of Microstrip Patch Antenna Arrays

Radiation Analysis of Phased Antenna Arrays with Differentially Feeding Networks towards Better Directivity

Broadband and Gain Enhanced Bowtie Antenna with AMC Ground

User Conference Title

COMPACT SHORTED MICROSTRIP PATCH ANTENNA FOR DUAL BAND OPERATION

Microwave-induced acoustic imaging of biological tissues

Design and Development of Rectangular Microstrip Array Antennas for X and Ku Band Operation

State and Path Analysis of RSSI in Indoor Environment

DESIGN AND DEVELOPMENT OF MICROSTRIP PATCH ANTENNA

Variability in EMF Permittivity Values: Implications for SAR Calculations

Design and Development of Ultralow Sidelobe Antenna

3D FINITE ELEMENT ANALYSIS FOR NON- ASYMMETRY STRUCTURE ANTENNA FOR MICROWAVE ABLATION THERAPY

Dielectric Leaky-Wave Antenna with Planar Feed Immersed in the Dielectric Substrate

H. Arab 1, C. Akyel 2

Chapter 5 OPTIMIZATION OF BOW TIE ANTENNA USING GENETIC ALGORITHM

MICROWAVE SCATTERING FOR THE CHARACTERIZATION OF A DISC-SHAPE VOID IN DIELECTRIC MATERIALS AND COMPOSITES

13 Bellhouse Walk, Bristol, BS11 OUE, UK

Admittance Loading Of Dielectric Loaded Inclined Slots In The Narrow Wall Of A H-Plane Tee Junction

Isolation Enhancement in Microstrip Antenna Arrays

The analysis of microstrip antennas using the FDTD method

Rectangular Patch Antenna to Operate in Flame Retardant 4 Using Coaxial Feeding Technique

Miniaturized and Dual Band Hybrid Koch Dipole Fractal Antenna Design

Extraction of Antenna Gain from Path Loss Model. for In-Body Communication

ANALYSIS OF HUMAN BREAST MILK AT MICROWAVE FREQUENCIES

Design and Analysis of Two Slot Antenna for Microwave Ablation

Electromagnetic Band Gap Structures in Antenna Engineering

Dual-Band Dual-Polarized Antenna Array for Beam Selection MIMO WLAN

Design of a 2.45 GHz Circularly Polarized Rectenaa for Electromagnetic Energy Harvesting

PLANAR BEAM-FORMING ARRAY FOR BROADBAND COMMUNICATION IN THE 60 GHZ BAND

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Magnetic Response of Rectangular and Circular Split Ring Resonator: A Research Study

A PERTURBED CIRCULAR MONOPOLE ANTENNA WITH CIRCULAR POLARIZATION FOR ULTRA WIDEBAND APPLICATIONS

Keywords-Microstrip, Fractal, Sierpinski.

Decision Feedback Equalizer A Nobel Approch and a Comparitive Study with Decision Directed Equalizer

Sensor and Simulation Notes Note 548 October 2009

High Permittivity Design of Rectangular and Cylindrical Dielectric Resonator Antenna for C-Band Applications

Short Interfacial Antennas for Medical Microwave Imaging

THEORETICAL AND EXPERIMENTAL RESEARCH OF A HORN ANTENNA NEAR FIELD

ECHO-CANCELLATION IN A SINGLE-TRANSDUCER ULTRASONIC IMAGING SYSTEM

Absorbers and Anechoic Chamber Measurements

Analysis of Crack Detection in Metallic and Non-metallic Surfaces Using FDTD Method

A WIDEBAND RECTANGULAR MICROSTRIP ANTENNA WITH CAPACITIVE FEEDING

Transcription:

Exact Simultaneous Iterative Reconstruction Technique Algorithm-An Effective Tool In Biomedical Imaging Kalyan Adhikary 1, Poulomi Sinha 2, Priyam Nandy 3, Prantika Mondal 4 Assistant Professor, Dept of ECE, Modern Institute of Engineering and Technology, Bandel, West Bengal, India 1 B.Tech (Final Year), Dept of ECE, Modern Institute of Engineering and Technology, Bandel, West Bengal, India 2,3,4 ABSTRACT: In this paper, authors have verified and validated the effectiveness of Exact SIRT algorithm [1] for reconstruction of biological model. The biological model has been illuminated by a transmitting array antenna with a beam width of 6 0. The biological target is divided into large number of cells here 420 cells, so that complex permittivity and electric fields are assumed to be constant in the small area of each cell. Here Exact SIRT method of reconstruction algorithm has been applied on a semi-human sized biological model consisting of human organs like fat, muscle, liver, gallbladder and muscle type material and reconstructed complex permittivity value of the biological target are tabulated and reconstructed images obtained are presented in this paper. Reconstruction of complex permittivity of target area is simulated using Force 209 FORTRAN [2] and reconstructed images are depicted by using colour gradation scale. KEYWORDS: SIRT, Tomography, Complex permittivity, Exact algorithm. I. INTRODUCTION The Greek word tomos means parts or section and graph means representation in pictorial means. Hence tomography is the imaging technique of unknown cross section of any object. Tomography of a biological body using low microwave frequency range (near about 1 GHz) will be a non invasive technique for medical diagnosis as low microwave signal has less radiation hazard compare to X-rays in computed tomography. Moreover, interaction of microwaves with dielectric properties of biological tissue is attractive as complex permittivity of the tissue changes with the water content in it and this water content also changes with the penetration of disease. Thus the reconstruction of complex permittivity of the biological tissue discriminates the healthier tissue from the diseased one. Various iterative reconstruction algorithms based on moment method solution for randomly inhomogeneous biological model had been developed on the assumption that change of characteristic parameter of a cell produces effects on the other and hence, results a coupled effect on the receiver point. But the exact solution of such a large number of non-linear equations containing a large number of unknown variables is quite impossible. So, for ease of calculation the iteration methods [3]-[6] have been adopted. Improved first order and second order algorithm [7] considering the first order and second order mutual interaction terms fails to reconstruct larger model as higher order play the dominant role as compared to first order and second order mutual interaction terms. Hence perturbation equation becomes non-convergent. For the same reason these algorithms are not applicable for smaller model with large perturbation. Due to the above limitations of the reconstruction algorithms developed earlier, a new exact algorithm [1] had been developed where the difference of two electric fields, one is obtained when the object medium is assumed to be a homogeneous one and the other is obtained when actual experimental model is used at a particular receiver location, is expressed in terms of unknown permittivity, relevant co-factors of co-efficient matrix corresponding to the homogeneous medium and perturbed internal fields. Copyright to IJIRSET www.ijirset.com 68

The exact algorithm is based on the integral equation for the field of harmonic source in presence of a dielectric medium which is assumed to be divided into large number of small cells. The areas of the cells are kept very small so that electric field intensity and complex permittivity in each cell remain constant. Richmond [8] stated that total field at the centre of each cell must be equal to the sum of the incident field and the scattered field in that cell from the neighbouring cells and hence a system of linear equations can be obtained. Further, the change of characteristic parameter such as conductivity, permittivity etc. of a cell produces effects on all other cells and hence, results a coupled effect at the receiver point. Necessary modifications have been made subsequently in Exact algorithm for measurement of incident fields perturbed fields and the received fields in the targeted region [9], [10], [11], [12], [13]. In this paper, rectangular region of a biological target is illuminated by a transmitting antenna having beam width 6 0. II. PERTURBATION TECHNIQUE It is assumed that the dielectric region is divided into large number of cells, so that electric field intensity and complex permittivity in each cell is nearby uniform. According to Richmond [8] a system of linear equation can be obtained by equating the total field at the centre of each cell with the sum of incident and scattered fields at that centre for a sufficiently large number of cells, the solution approaches the exact solution. The field distribution in unperturbed homogeneous medium is expressed by the equation [C]. [E i ] = [E in i ] (1) in where E is the incident field at i-th cell in free space and E i i is the internal field at i-th cell when the medium is assumed to be homogeneous one having known permittivity distribution.[c] is (nxn) coefficient matrix of homogeneous medium. The homogeneous medium is now replaced by the inhomogeneous biological targets. As the dielectric medium is changed, the permittivity values of the cells are perturbed simultaneously by small amounts of Δε i ( i = 1, 2,., n ) and the corresponding changes in the internal fields are ΔE i s then [C ].[E i ]=[E i in ] (2) where [C ] is the coefficient matrix of the inhomogeneous medium and E i =[E i + ΔE i ] is the perturbed total field at the i-th cell. Exact algorithm [6] has been developed by expressing this field difference ΔE i in terms of requisite fractional change of permittivity x i of the i-th cell, relevant cofactors and perturbed internal fields E i =-x i E i + N j=1 x j E j ' M ji (0) (0) Δ(0) and M ji (0) are the determinant and cofactor of (j,i)-th element of unperturbed coefficient matrix [C] respectively. x i is the requisite fractional changes in permittivity values for different cells from the assumed initial permittivity for the medium which is given as x i =( model - homo )/ (ε homo -1) where homo and model are the complex permittivity of i-th cell of homogeneous medium and model to be imaged respectively. Hence the difference in field equation at the l-th receiver location for the k-th beam passing through it is N E Rml (k) E Rol (k) = x j E M jr (0) j=1 j (4) Δ(0) where E Rml (k) and E Rol (k) denote the scattered field intensity at the l-th receiver location for the k-th beam in the inhomogeneous and homogeneous numerical model respectively. The values of x i i.e., the requisite fractional changes in permittivity values for different cells for the medium can be determined from the set of eqn. (4). (3) Copyright to IJIRSET www.ijirset.com 69

If there are k=1, 2.q no. of beams passing through a particular cell, a set of q number of x j can be calculated from eqn.(4).the required value of x j is the average of the all the values. Here it is assumed that all the cells within the beam width are equally responsible for a particular change at the receiver location. The resultant correction in the complex permittivity that is applied to a particular cell is the average of all the corrections predicted by the different beams passing through that cell. In this way, different cells in the medium are examined one after another and resultant corrections in the complex permittivity are determined. III. RESULTS Numerical We have chosen a semi human-size model of 360 cells, each of 1 sq. cm. in area for verifying Exact SIRT algorithm [1]. It is a complex biological model consisting of different internal structures having complex permittivity identical to those observed in different human organs viz. stomach (60-j18 ), gallbladder (58-j18), liver(48-j12), muscle (50-j23), muscle type material (40-j23) and fat (25-j5)[14],[15]. The model is surrounded by saline water region having 340 cells, each of same 1 sq. cm. area. The total area of model and saline water region is 28x25 sq. cm. The model is illuminated by 15x15 quarter wave dipole array antenna shown in the fig. 1 with a beam width of 6 0 operating at 1 GHz [16]. 20 half wave dipoles are used as receivers and placed at the opposite side of the transmitting antenna. To reduce the effective length of the antenna and multipath propagation, transmitting antenna, receiving antenna and the biological target should be immersed in saline water. Wavelength in the saline water is reduced by a factor of 76 and reduced to 3.14 cm. Block diagram of proposed experimental setup of model and data collecting system is shown in fig.1. Fig. 1: Block diagram of proposed experimental setup of model and data collecting system [16]. Copyright to IJIRSET www.ijirset.com 70

Figures and Tables Numerical models are simulated using Force 209 Fortran and depicted using colour gradation scale. Fig. 2 : Gradation scale used for imaging. Reconstruction of normal model Fig. 3.1 Fig. 3.2 Fig. 4.1 Fig. 4.2 Fig. 3.1 & Fig. 3.2 : Real and imaginary values of complex permittivity of normal model; Fig. 4.1 & fig. 4.2: Reconstructed real and imaginary values of complex permittivity of normal model. Reconstruction of diseased model The model under study is the same as that considered in earlier case, except its stomach region is affected by some disease and hence characterized by a different value of complex permittivity (66-j19.8) where as for normal stomach it is assumed as (60-j18). Fig. 5.1 Fig. 5.2 Fig. 6.1 Fig. 6.2 Fig. 5.1 & fig. 5.2: Real and imaginary values of complex permittivity of diseased model; Fig. 6.1 & fig. 6.2: Reconstructed real and imaginary values of complex permittivity of diseased model Copyright to IJIRSET www.ijirset.com 71

TABLE I AVERAGE VALUES OF PERMITTIVITY OF DIFFERENT ORGANS OF NORMAL MODEL Different Organs of Average Values of Complex Permittivity of Different Organs Normal Fat 25-j5 23.24 -j3.82 Muscle 50-j23 50.26-j23.78 Muscle type material 40-j23 39.07-j23.78 Liver 48-j12 48.06-j11.53 Stomach 60-j18 61.34-j18.11 Gallbladder 58-j18 61.40-j18.11 Water 76-j40 76-j40 Reconstructed Normal TABLE II AVERAGE VALUES OF PERMITTIVITY OF DIFFERENT ORGANS OF DISEASED MODEL Different Organs of Average Values of Complex Permittivity of Different Organs Diseased Reconstructed Diseased Fat 25-j5 22.89 -j3.72 Muscle 50-j23 49.68 -j23.66 Muscle type material 40-j23 38.29 -j23.66 Liver 48-j12 47.63-j11.52 Stomach 66-j19.8 67.55 -j20.04 Gallbladder 58-j18 61.30-j20.04 Water 76-j40 76-j40 IV.CONCLUSION So in this paper, Exact simultaneous iterative reconstruction algorithm has been discussed and validated on a semi human size normal biological model and a diseased model (stomach region is affected). The reconstructed image of normal model obtained by Exact SIRT has an average accuracy of 99.75%. In case of diseased stomach model the real part of the reconstructed images obtained by using Exact SIRT show a great amount of deviations of complex permittivity from their normal values which indicate some ailment at the stomach region. The imaginary part of reconstructed image of diseased stomach region is able to indicate the affected portion and showing better resemblance with the diseased model and appears to be very promising for detection of diseased portion in its early stage even in larger model with large perturbation (not more than 20%). Considering the quality of microwave images achieved so far, it can be concluded that future improvement in microwave imaging technique will help the medical professionals to detect the cancerous cells in early stage, to locate and measure edema, to inspect the infectious muscles and soft tissues structures and to measure lung water content more accurately. Thus microwave imaging technique will serve immense benefit to mankind. Copyright to IJIRSET www.ijirset.com 72

REFERENCES [1] K.Purkait & A.N.Datta, An Exact Algorithm for Microwave Tomography, presented at symposium HOT-2003,INRAPHEL,C.U.3rd-5th Feb.2003. [2] Force 209 FORTRAN Compiler, www.lepsch.com. [3] A.N. Datta & B. Bondopadhyay, Int J Electronics, Vol. 58, No.5,pp.831-832, 1985. [4] A.N. Datta & B. Bandyopadhyay, An Improved SIRT-Style Reconstruction Algorithm for Microwave Tomography, IEEE Transactions on Biomedical Engineering, Vol. BME-32, No. 9, pp.719-723, September 1985. [5] A N Datta & B. Bondopadhyay, Proc. of IEEE, Vol. 74, pp.604-606, 1986. [6] A N Datta & B. Bondopadhyay, Innov. Tech Biol. Med, Vol. 8, pp.409-416, 1987. [7] K.Purkait & A.N.Datta, An Improved form of Iterative Reconstruction Algorithm for First Order and Second Order Microwave Image Reconstruction, Indian Journal of Pure & Applied Physics,CSIR,Vol.34,pp.420-424, June1996. [8] J.H. Richmond, IEEE Trans. Antennas Propag. Vol. AP-B, pp 334-341, 1965. [9] K.D. Prasad, Antenna & Wave propagation(isbn No: 81-7684-025-4, 3rd edition, 2007). [10] K.T. McDonald, Radiation in the Near Zone of a Centre -Fed Linear Antenna (June21,2003) (http://puhep1.princeton.edu/~mcdonald/examples/linearantenna.pdf). [11] K.T. McDonald, The Fields of a Short, Linear Dipole Antenna If There Were No Displacement Current(Joseph Henry Laboratories, Princeton University, Princeton, NJ 08544, July 5, 2006). [12] Kabita Purkait and Kalyan Adhikary Application of Modified Cell Scanning Technique in Exact Algorithm for Medical Diagnosis, IJTS Vol- 21,pp.115-127,October 2012. [13] Kabita Purkait and Kalyan Adhikary, Modification in field measurement applied on exact algorithm for biomedical imaging, IJMER, Vol. 2, Issue-3, pp. 1157-1161, May 2012. [14 ] Herman Schwan and Kenneth Foster, RF-field interaction with biological systems: Electrical properties and biophysical mechanisms, Proc. of the IEEE, 68(1), 1980. [15 ]Susan R Smith & Kenneth R Foster, Dielectric properties of low-water-content tissues, Phys. Med. Biol., Vol. 30, No. 9, pp.965-973,1985. [16]K.Purkait & S.Mondal, Application of Exact Simultaneous Iterative Reconstruction Algorithm for Medical Diagnosis, IEEE EDS Student Paper Conference 2011, pp.22-25, April 2011. Copyright to IJIRSET www.ijirset.com 73