3. SIGNIFICANCE AND USE 3.1 These test methods provide a quantitative measure of the tack property of a pressure sensitive adhesive.

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

GB/T Translated English of Chinese Standard: GB/T

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. FZ/T

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

QB/T Translated English of Chinese Standard: QB/T LIGHT INDUSTRY STANDARD

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T819.

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

This document is a preview generated by EVS

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE

FZ/T Translated English of Chinese Standard: FZ/T

GB/T / IEC :2007

JB/T Translated English of Chinese Standard: JB/T

NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA

GB/Z Translated English of Chinese Standard: GB/Z

Standard Test Methods for Loop Tack 1

GB/T Translated English of Chinese Standard: GB/T

IGPG Car Wash Round Robin Test Procedure

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF

GB/T / ISO 594-1:1986

INTERNATIONAL STANDARD

ISO 534. Paper and board Determination of thickness, density and specific volume

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

1. Scope. 2. Apparatus The apparatus shall comprise at least the following individual components: IGPG Car Wash Round Robin Test Procedure

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

National Standard of The People s Republic of China

QB/T Translated English of Chinese Standard: QB/T LIGHT INDUSTRY STANDARD OF

INTERNATIONAL STANDARD

TB/T Translated English of Chinese Standard: TB/T RAILWAY INDUSTRY STANDARD

Rubber, vulcanized or thermoplastic Determination of abrasion resistance using a rotating cylindrical drum device

QB/T Translated English of Chinese Standard: QB/T

Test methods for lead-free solders- Part 5 : Methods for tensile tests and shear tests on solder joints

GB/T / ISO :1999

Test Panel Information Sheet

Installation and Care Instructions: Rear Windshield - CFMOTO UForce 800

ISO 105-X18 INTERNATIONAL STANDARD. Textiles Tests for colour fastness Part X18: Assessment of the potential to phenolic yellowing of materials

GB/T / CISPR 15:2005

GB / IEC/CISPR 11:2010

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD

ANCHOR PLATE ATTACHMENT STEEL STUD FRAMING OR FURRING CONSTRUCTION WITH ACCESS FROM PANEL SIDE ONLY

Installation Instructions

ISO ~ISOJ INTERNATIONAL STANDARD. Plastics and ebonite - Determination of indentation hardness by means of a durometer (Shore hardness) - --

ISO 2808 INTERNATIONAL STANDARD. Paints and varnishes Determination of film thickness. Peintures et vernis Détermination de l'épaisseur du feuil

INTERNATIONAL STANDARD

3M XYZ-Axis Electrically Conductive Adhesive Transfer Tape (ECATT) 9723

Pencil Hardness Tester BEVS 1301

ISO INTERNATIONAL STANDARD

Part 1: Rolling bearings Balls. Steel balls

ORAFLEX Cushion. for Flexible Packaging. Flexographic Mounting Tapes - Bringing life to your prints. Cushion Mounting Tapes

3M Impact Protection Profile Installation System Instructions

Initial wet-web tensile strength, stretch and tensile energy absorption

Pilkington OptiView Protect. Pilkington OptiView. Handling and Processing Guidelines

Practical Information ORALITE Reflective Films of Class RA2, Grade B for Road Safety

EAST AFRICAN STANDARD

Corrugated fibreboard Determination of edgewise crush resistance (unwaxed edge method)

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB/T Translated English of Chinese Standard: GB/T

SMT Troubleshooting. Typical SMT Problems For additional process solutions, please refer to the AIM website troubleshooting guide

GB/T / CISPR 25:2008

ISO INTERNATIONAL STANDARD. Textiles Determination of fabric propensity to surface fuzzing and to pilling Part 2: Modified Martindale method

Introduction to the development of FEFCO Testing Methods for corrugated board and boxes

Applying Aspheric Mirrors to a BMW R1200RS Motorcycle. Richard Clompus Trinidad, CA

PanelKeeper GL1500 Kit

Read and understand the requirements of this procedure Assist students with installation as needed

ISO INTERNATIONAL STANDARD IULTCS/IUF 470. Leather Test for adhesion of finish. Cuir Essai d'adhérence du finissage. Second edition

1. Storage and transportation. Care Instruction

Cold curing adhesive K-X280

Elcometer Cross Hatch Cutter. Operating Instructions

HERNON MANUFACTURING, INC.

INTERNATIONAL STANDARD

Part E04: Textiles Tests for colour fastness. Colour fastness to perspiration

ISO INTERNATIONAL STANDARD. Panneaux à base de bois Détermination du module d'élasticité en flexion et de la résistance à la flexion

ME 25 ENGLAND. Tel +44 (0) Web 1 Blatchford Road, Horsham, West Sussex RH13 5QR

EAST AFRICAN STANDARD

PSA PEUGEOT CITROËN METHODES D ESSAI MATIERES PAINT COATINGS RESISTANCE TO BIOLOGICAL ATTACKS NO USE RESTRICTION

ISO INTERNATIONAL STANDARD. Fasteners Non-electrolytically applied zinc flake coatings

APPLICATION OF JAC FILMS

ISO INTERNATIONAL STANDARD. Textiles Determination of fabric propensity to surface fuzzing and to pilling Part 1: Pilling box method

Standard Practice for Preparation of Bar and Rod Specimens for Adhesion Tests 1

EAST AFRICAN STANDARD

PolyCarb has good resistance to many chemicals. Some chemicals may harm the PolyCarb sheets. Contact us when in doubt about any chemical.

GB Translated English of Chinese Standard: GB National Standard of the People's Republic of China

PART NUMBER: T-R20 PACKAGE CONTENTS: GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS Scuff Plate TOOLS REQUIRED: APPLICABLE MODELS: 2013 MAZDA CX-

ISO 534 INTERNATIONAL STANDARD. Paper and board Determination of thickness, density and specific volume

3 Scotchmate Reclosable Fasteners

SPECIFICATIONS FOR 3M TM PRESTIGE SUN CONTROL WINDOW FILMS

Identification cards Physical characteristics

ISO INTERNATIONAL STANDARD. Paints and varnishes Determination of film hardness by pencil test

Organic Products Part 4: Management System

Practical Information ORALITE Reflective Films of Class RA3B, Grade C for Road Safety

Transcription:

Translated English of Chinese Standard: GB/T4851-2014 www.chinesestandard.net Sales@ChineseStandard.net GB NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA ICS 83.180 Z 38 GB/T 4851-2014 Replacing GB 4851-1998 Measurement of Static Shear Adhesion for Adhesive Tapes (ISO 29863:2007, Self Adhesive Tapes - Measurement of Static Shear Adhesion, MOD) 胶粘带持粘性的试验方法 Issued on: July 8, 2014 Implemented on: December 1, 2014 Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of the People's Republic of China. www.chinesestandard.net Page 1 of 23

Table of Contents Foreword... 3 1 Scope... 5 2 Normative References... 5 3 Terms and Definitions... 5 4 Classification... 6 5 Method A: Measurement of Shear Adhesion to a Vertical Standard Steel Panel... 7 6 Method B: Measurement of Shear Adhesion to a Vertical Panel Covered with NIST SRM 1810A Standard Fibreboard... 12 7 Method C: Measurement of Shear Adhesion to a Vertical Panel Covered with a Fibreboard Agreed upon by the Buyer and Seller... 13 8 Method D: Measurement of Shear Adhesion of Filament Reinforced Tape Applied to a Horizontal Standard Steel Panel... 14 9 Method E: Measurement of Shear Adhesion of Filament Reinforced Tape Applied to a Horizontal Panel Covered with NIST SRM 1810A Standard Fibreboard... 16 10 Method F: Measurement of Shear Adhesion of Filament Reinforced Tape Applied to a Horizontal Panel Covered with a Fibreboard Agreed upon by the Buyer and Seller... 17 11 Method G: Measurement of Shear Adhesion to a Vertical Standard Steel Panel at an Elevated Temperature after 10 min Dwell Time... 18 Annex A (Informative) The Structural Changes between This Standard and ISO 29863:2007... 21 Annex B (Informative) Technical Differences and Their Reasons between This Standard and ISO 29863:2007... 22 www.chinesestandard.net Page 2 of 23

Foreword This Standard was drafted according to the rules given in GB/T 1.1-2009. This Standard replaces GB/T 4851-1998 Test Method for Holding Power of Pressure Sensitive Adhesive Tapes. Compared with GB/T 4851-1998, the main technical differences of this Standard are as follows: -- the Standard name is changed into Measurement of Static Shear Adhesion for Adhesive Tapes ; -- the reference to standard JB/T 7499-1994 Coated Abrasives - Waterproof Abrasive Paper is deleted (See Chapter 2 of 1998 Edition); -- the term of roughness average is added (See 3.2); -- the types of cleaning agents are changed (See 5.2.2; 4.4.1 of 1998 Edition); -- the cutting method of samples is added (See 5.3.1); -- the requirements for standard test steel panel are changed (See 5.3.2; 4.2 of 1998 Edition); -- the dimensions and mass of rollers are changed (See 5.3.3.1; 4.3.1 and 4.3.3 of 1998 Edition); -- the requirements for test stand are changed (See 5.3.4.1; 4.1 of 1998 Edition); -- the standard test conditions of the laboratory are changed (See 5.4.1; 6.1 of 1998 Edition); -- the standard dimensions of test pieces are changed (See 5.4.2; Chapter 5 of 1998 Edition); -- the cleaning method for steel panel is changed (See 5.5.2; 7.1 of 1998 Edition); -- the number of times of rolling and applying is changed (See 5.5.3.1; 7.2 of 1998 Edition); -- the preparation time of samples and the dwell time before testing are changed (See 5.5.3.1; 7.4 of 1998 Edition); -- the handling of test results is changed (See 5.6; Chapter 8 of 1998); -- the measurement of shear adhesion of filament reinforced tape applied to a horizontal standard steel panel is added (See Chapter 8); -- the measurement of measurement of shear adhesion of filament reinforced tape applied to a horizontal panel covered with NIST SRM 1810A standard fibreboard www.chinesestandard.net Page 3 of 23

Measurement of Static Shear Adhesion for Adhesive Tapes 1 Scope This Standard specifies a series of test methods for the determination of the ability of an adhesive tape to remain adhered under a constant load applied parallel to the surfaces of the tape and substrate. This Standard applies to the measurement of static shear adhesion for adhesive tapes. 2 Normative References The following documents are essential to the application of this Standard. For dated references, only the dated editions apply to this Standard. For undated references, the latest edition (including all amendments) applies to this Standard. GB/T 2523-2008 Measuring Method of Surface Roughness and Peak Count for Cold-Rolled Metal Sheet (Strip) GB/T 3280-2007 Cold Rolled Stainless Steel Plate Sheet and Strip GB/T 22396 Terminology Relating to Pressure Sensitive Adhesive Products 3 Terms and Definitions For the purpose of this Standard, the following terms and definitions and those defined by GB/T 22396 apply to this Standard. 3.1 Static shear adhesion It is the resistance of the pressure sensitive adhesive against shear when forces are exerted parallel to the bonding surface. 3.2 Roughness average It is the arithmetic average deviations of surface roughness profile, i.e. the arithmetic average of surface roughness profile offset absolute values within the sampled length. 3.3 Test assembly It is the assembly formed after the adhesive tape to be tested is applied to the test www.chinesestandard.net Page 5 of 23

-- diacetone alcohol (4-Hydroxy-4-methyl-2-pentanone), non residual grade; -- methanol; -- methyl ethyl ketone; -- acetone; -- n-heptane; -- isopropyl alcohol; -- a mixture of n-heptane and a fluorinated hydrocarbon such as refrigerant (suitable when toxicity or flammability restrictions apply). Solvents shall be of general purpose chemical grade and held in a suitable dispensing system. 5.3 Apparatus 5.3.1 Test piece cutter A test piece cutter shall hold two single edge razor blades in parallel planes a precise distance apart, to form a cutter of exact test piece width; two cutters, 12 mm and 24 mm cutting width, shall be available or appropriate alternatives which will not cause edge damage. The precision of the razor blade separation shall be the nominal width ± 0.1 mm. 5.3.2 Stainless steel panels These shall be perfectly flat, at least 125 mm long and 50 mm wide and at least 1,1 mm thick, stainless steel (hereinafter referred to as steel panel) type in accordance with the 06Cr19Ni10 quality defined in GB/T 3280-2007, having a bright annealed finish with a surface roughness (GB/T 2523-2008) of 50 nm ± 25 nm. Panels showing stains, discoloration or many scratches are not acceptable. New panels shall be cleaned prior to use as described in 5.5.2. Between uses the panel test surface shall be protected from scratches and contamination and the panels shall be stored in the conditions described in 5.4.1. 5.3.3 Roller mechanically or hand operated 5.3.3.1 A cylindrical steel roller (hereinafter referred to as roller) 85 mm ± 2.5 mm in diameter and 45 mm ± 1.5 mm in width, covered with rubber approximately 6 mm in thickness, having a Shore A durometer hardness of 80 ± 5. The surface shall be a true cylinder, void of any convex or concave deviations. The mass of the roller shall be 2 kg ± 0.1 kg. 5.3.3.2 No part of the apparatus shall increase the mass of the roller during use. The www.chinesestandard.net Page 8 of 23

5.4.6 Apply the test pieces within 5 minutes after unwinding. 5.5 Procedure 5.5.1 Standard test conditions Standard test conditions shall be the same as 5.4.1 for test pieces and test samples conditioning. 5.5.2 Preparation of the panel 5.5.2.1 Dispense one of the solvents listed in 5.2.2 on to the panel, wiping it to dryness with fresh absorbent cleaning material. Repeat for a total of three washes with this solvent. Final wipe shall be with methyl ethyl ketone or acetone. The panel should be allowed to dry for at least 10 min. Panels not used within 10 h should be recleaned. In order to obtain consistent results a new panel shall be wiped at least ten times with final solvent before use. NOTE: Discard plates showing stains, discoloration, or many scratches. Avoid contacting panel surface with fingers. During storage panel should, be protected from damage or contamination. 5.5.3 Shear adhesion 5.5.3.1 Test piece preparation Centre the test piece at one end of the test panel and apply without added pressure to cover an area of 12 mm ± 0.5 mm by 12 mm ± 0.5 mm, unless other dimensions are specified. The exposed adhesive of the free area of the test piece may be masked. To prevent damaging the test piece by the end of the panel during roll down, place another panel of the same or slightly lesser thickness under the free masked end of the test piece, and in contact with the end of the panel prior to roll down. Roll down the applied test area twice, once in each lengthwise direction. Prepare at least 3 test pieces. Individually prepare each test piece and begin test within 1 min. For tapes other than packaging tapes, other dwell times may be used but shall be reported. NOTE: The tester should know that by prolonged handling, heat is transmitted to the stainless steel test panel. Therefore, during and after application of the adhesive tape to the test panel, the panel should be handled as little as possible. 5.5.3.2 Shear adhesion test The following action shall be completed within one minute of rolling the sample in www.chinesestandard.net Page 10 of 23

As 5.4.1. 6.5.2 Preparation of the panel Apply a piece of double sided tape centrally to the clean panel. Superimpose a piece of the fibreboard wider and longer than the sample to be tested, ensuring that it is correctly applied with the proper side up and the grain of the paper perpendicular to the long axis of the test panel and roll firmly. 6.5.3 Shear adhesion 6.5.3.1 Test piece preparation Follow 5.5.3.1 applying the test piece onto the fibreboard. 6.5.3.2 Shear adhesion test As 5.5.3.2. 6.6 Expression of results As 5.6. 6.7 Test report As 5.7. 7 Method C: Measurement of Shear Adhesion to a Vertical Panel Covered with a Fibreboard Agreed upon by the Buyer and Seller 7.1 Principle Method C of this standard measures the shear adhesion of a self adhesive tape to a fibreboard surface agreed upon by the buyer and seller by its time to failure at 23 C and 50 % RH under constant load. Shear Adhesion to fibreboard A strip of tape is applied to a suitable panel covered with a fibreboard designated under controlled roll down. The panel is mounted vertically, a standard mass is attached to the free end of the tape and the time to failure is determined. 7.2 Procedure This method is identical to method B (6.5.1 to 6.5.3.2) except for the choice of fibreboard used. www.chinesestandard.net Page 13 of 23

The following action shall be completed within one minute of rolling the sample in 8.5.3.1. Place the clamp or hook on the free end of the test piece, ensuring that it extends completely across the width of the test piece, and is aligned to distribute the load uniformly. Place the test assembly in the test stand so that the panel is horizontal, tape side up, and the free end of the test piece is vertical. Apply the 4.5 kg mass to the clamp or hook gently so as to cause no shear impact force on the test piece. After 48 h under load, examine the test piece for evidence of slippage. Measure any slippage that has occurred to the nearest 1 mm. 8.6 Expression of results Determine the arithmetic average of the slippage recorded for each test piece. NOTE: The slippage recorded in mm will be reported. 8.7 Test report The test report shall include the following information: a) a reference to this Standard; b) statement that this test method was used and indicating any deviations from the method was written; c) identification of each roll of tape tested; d) dwell time; e) width of test piece if other than 12 mm; f) slippage in mm; g) conditions of test. 9 Method E: Measurement of Shear Adhesion of Filament Reinforced Tape Applied to a Horizontal Panel Covered with NIST SRM 1810A Standard Fibreboard 9.1 Principle Method E of this standard measures the shear adhesion of a filament reinforced tape www.chinesestandard.net Page 16 of 23

11 Method G: Measurement of Shear Adhesion to a Vertical Standard Steel Panel at an Elevated Temperature after 10 min Dwell Time 11.1 Principle Method G of this standard measures the shear adhesion of a self adhesive tape to a standard steel panel at an elevated temperature after a 10 min dwell time by its time to failure under constant load. Shear adhesion to standard steel panel A strip of tape is applied to a standard steel panel under controlled roll down. The panel is mounted vertically, in an oven at the test temperature, a standard mass is attached to the free end of the tape and the time to failure is determined. 11.2 Procedure This method is the same as method A (5.5.1 to 5.5.3.2) except that the test stand shall be installed in an oven capable of maintaining the desired elevated temperature ± 1 C. The test piece shall be conditioned in the oven for 10 min before attaching the mass. The temperature used for the test shall be reported with the results. www.chinesestandard.net Page 18 of 23

consistent with the similar method standards in structure, which reflects the uniformity of standards. Table 1 of Chapter 4 Add Table 1 Instructions for the test methods Define use objects, for the for the Measurement of Static Shear Adhesion convenience of implementation of this for Adhesive Tapes Standard 5.2.2 Add the cleaning agent isopropyl alcohol According to the actual conditions of China, isopropyl alcohol is the one of the best choices of cleaning agents in terms of both environmental protection and costs. 5.4.1 Add: condition the samples in standard environmental conditions for 24 h Increase maneuverability, for the convenience of implementation of this Standard END www.chinesestandard.net Page 23 of 23