Comparison of Various RF Calibration Techniques in Production: Which is Right for You? Daniel Bock, Ph.D.

Similar documents
Wafer-Level Calibration & Verification up to 750 GHz. Choon Beng Sia, Ph.D. Mobile:

WinCal XE. Leonard Hayden Cascade Microtech, Inc.

Introduction to On-Wafer Characterization at Microwave Frequencies

Managing Complex Impedance, Isolation & Calibration for KGD RF Test Abstract

Verification of LRRM Calibrations with Load Inductance Compensation for CPW Measurements on GaAs Substrates

Measurements with the LeCroy SPARQ and Cascade Microtech Probes Using WinCal XE Calibrations

ON-WAFER CALIBRATION USING SPACE-CONSERVATIVE (SOLT) STANDARDS. M. Imparato, T. Weller and L. Dunleavy

Measurements with Scattering Parameter By Joseph L. Cahak Copyright 2013 Sunshine Design Engineering Services

Measuring the Invasiveness of High-Impedance Probes

Challenges and Solutions for Removing Fixture Effects in Multi-port Measurements

Configuration of PNA-X, NVNA and X parameters

There is a twenty db improvement in the reflection measurements when the port match errors are removed.

Gain Lab. Image interference during downconversion. Images in Downconversion. Course ECE 684: Microwave Metrology. Lecture Gain and TRL labs

MPI Probe Selection Guide

Agilent AN Applying Error Correction to Network Analyzer Measurements

FABRICATING AND USING A PCB-BASED TRL PATTERN WITH A CMT VNA

Extraction of Broadband Error Boxes for Microprobes and Recessed Probe Launches for Measurement of Printed Circuit Board Structures

AC-2 Calibration Substrate

Application Note 5525

RF Characterization Report

Millimeter Signal Measurements: Techniques, Solutions and Best Practices

CALIBRATION TYPES & CONSIDERATIONS

Waveguide Calibration with Copper Mountain Technologies VNA

product note Using Power Leveling to Control Test Port Output Power Product Note 8510XF XF Network Analyzer

March 4-7, 2018 Hilton Phoenix / Mesa Hotel Mesa, Arizona Archive

Infinity Probe Mechanical Layout Rules

Calibration and Accuracy in Millimeter Systems. Keith Anderson

Technologies Vector Reflectometers

FieldFox Handheld Education Series Part 3: Calibration Techniques for Precise Field Measurements

Vector Network Analyzer

GAIN COMPARISON MEASUREMENTS IN SPHERICAL NEAR-FIELD SCANNING

Schematic-Level Transmission Line Models for the Pyramid Probe

Network Analysis Basics

Limitations And Accuracies Of Time And Frequency Domain Analysis Of Physical Layer Devices

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand

Characterizing Non-Standard Impedance Channels with 50 Ohm Instruments

5 ESSENTIAL HINTS TO IMPROVE Millimeter-wave Network Analysis

MEMS process on RF Probe Cards. Yock Hsu, James Wang, Alex Wei, Fred Chou, Adolph Cheng

(a) The insertion loss is the average value of the transmission coefficient, S12 (db), in the passband (Figure 1 Label A)

Agilent Accurate Measurement of Packaged RF Devices. White Paper

Calibration and De-Embedding Techniques in the Frequency Domain

NATIONAL UNIVERSITY of SINGAPORE

Abstract: Stringent system specifications impose tough performance requirements on the RF and microwave cables used in aerospace and defense

Operation of Microwave Precision Fixed Attenuator Dice up to 40 GHz

S-Parameter Measurements with the Bode 100

Microwave Metrology -ECE 684 Spring Lab Exercise T: TRL Calibration and Probe-Based Measurement

A Comparison of Harmonic Tuning Methods for Load Pull Systems

THz Vector Network Analyzer Development & Measurements

Compact Series: S5065 & S5085 Vector Network Analyzers KEY FEATURES

High Speed Characterization Report

A PROBE TECHNOLOGY FOR 110+ GHZ INTEGRATED CIRCUITS WITH ALUMINUM PADS

New Ultra-Fast Noise Parameter System... Opening A New Realm of Possibilities in Noise Characterization

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B / USB-TG44A. Application Note 1: The Smith Chart. Rev. 0

Determination of Uncertainty for Dielectric Properties Determination of Printed Circuit Board Material

Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

Probe. Selection Guide

A Simplified QFN Package Characterization Technique

Vector Network Analyzer Application note

Application Note: Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

Measuring PCB, Cable and Interconnect Impedance, Dielectric Constants, Velocity Factor, and Lengths

On-Wafer Noise Parameter Measurements using Cold-Noise Source and Automatic Receiver Calibration

SWR/Return Loss Measurements Using System IIA

Data Sheet. VMMK GHz Directional Detector in SMT Package. Features. Description. Specifications (35 GHz, Vb = 1.5 V, Zin = Zout = 50 Ω)

Agilent Technologies Gli analizzatori di reti della serie-x

Agilent PNA Microwave Network Analyzers

Platform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies

Data Sheet. VMMK GHz Positive Gain Slope Low Noise Amplifier in SMT Package. Features. Description

Keysight Technologies Applying Error Correction to Vector Network Analyzer Measurements. Application Note

Microwave Measurements for signal integrity applications

T est POST OFFICE BOX 1927 CUPERTINO, CA TEL E P H ONE (408) FAX (408) ARIES ELECTRONICS

3680 Series. Universal Test Fixtures. A Complete Measurement Solution. DC to 60 GHz DC to 20 GHz 3680K DC to 40 GHz 3680V DC to 60 GHz

High Speed Characterization Report

A Measurement of Non-Coaxial RF Devices with Improved TRL Calibration Algorithm

Aries Kapton CSP socket

Archive 2017 BiTS Workshop- Image: Easyturn/iStock

for RF testing up to 110GHz

PLANAR S5048 and TR5048

Agilent On-wafer Balanced Component Measurement using the ENA RF Network Analyzer with the Cascade Microtech Probing System. Product Note E5070/71-3

Optoelectronic Components Testing with a VNA(Vector Network Analyzer) VNA Roadshow Budapest 17/05/2016

Compact Series: S5048 & TR5048 Vector Network Analyzers KEY FEATURES

High Performance Microwave Probes for RF probing

54100A Series. Network Analyzers. Precision Return Loss Measurements. Application Note

March 4-7, 2018 Hilton Phoenix / Mesa Hotel Mesa, Arizona Archive

Data Sheet. ACMD-7402 Miniature PCS Band Duplexer. Description. Features. Specifications. Applications. Functional Block Diagram

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Validation & Analysis of Complex Serial Bus Link Models

ECE 4265/6265 Laboratory Project 7 Network Analyzer Calibration

Simplifying the Art of Terahertz Measurements

PLANAR 814/1. Vector Network Analyzer

Data Sheet. VMMK GHz Directional Detector in SMT Package. Features. Description. Specifications (4 GHz, Vb = 1.5 V, Zin = Zout = 50 Ω)

Data Sheet. ACMD-7409 Miniature PCS Band Duplexer. Features. Description. Specifications. Applications. Functional Block Diagram

Data Sheet. VMMK GHz UWB Low Noise Amplifier in SMT Package. Features. Description

E/O and O/E Measurements with the 37300C Series VNA

UNDERSTANDING NOISE PARAMETER MEASUREMENTS (AN )

Keysight Technologies PNA Microwave Network Analyzers

Electronic Calibration (ECal) Modules for Vector Network Analyzers

Probe. Selection Guide

Preliminary Users Manual for the Self Contained Return Loss and Cable Fault Test Set with Amplified Wideband Noise Source Copyright 2001 Bryan K.

Overcome mmwave Component Test Challenges. Senior Project Manager / Keysight Technologies

A New Noise Parameter Measurement Method Results in More than 100x Speed Improvement and Enhanced Measurement Accuracy

Transcription:

Comparison of Various RF Calibration Techniques in Production: Which is Right for You? Daniel Bock, Ph.D.

Overview Introduction How does Calibration Work Types of Calibrations Comparison of Calibration Types Summary 2

Why do you need Calibration? You want a guarantee that you are measuring your DUT and NOT you test equipment The Probes and cabling introduces errors However, Calibration is able to remove those errors 3

How does Calibration Work In characterizes the RF performance parameters of your test hardware Then mathematically remove the parameters 4

A Little Math. 5

How to get to the measurement system error terms One characterizes the RF parameters of your system by measuring some known RF structures Open Short Load Thru Calibration can be various combinations of these standards based on your needs 6

Calibration Substrates The choice of the calibration substrate is important based on what you want to do: Edge of pad End of transmission line Type of Calibration Frequency Range Tip Pitch 7

More about the Reference Plane The reference plane can be placed ALMOST anywhere in the RF signal path Can located at the: Edge of the Pad End of a transmission line to the DUT 8

Calibration to edge of Pads Place standards connected to pads Allows for removal of the full contact area For high frequency, requires accurate Probe-To-Pad- Alignment to be successful Highest accuracy by using standards on wafer, but good accuracy for can be achieved using ISS standards, especially in KGD applications 9

Calibration to end of Xline This will generally require the use of on wafer standards Make a transmission line like that connected to the DUT, and then place your calibration standards 10

Cal Coefficients Cal Coefficients are values that characterize the RF performance of the standards They are never ideal Opens, Short, Loads, and the Thru has a characteristic length These are input into the previous equations as the known terms using the reflection coefficient 11

But Do you need Cal Coeff? In some situations, you can actually ignore the Cal Coeff. Depends upon Max Frequency and value of Cal Coeff. Evaluated for 150 µm GSG for the model C_open = 3.5 ff L_load=-1.7 ph L_short = 4.8 ph 12

Plot of Variation of Open and Short The varition is dominated by the Short At less than 20 GHz, it is less than 0.1 db off from ideal -20 Reflection Coeff for Load (-1.7 ph) 0-0.05 Reflection Coeff for Open and Short (3.5 ff and 4.8 ph) Short Open -22-24 -0.1-26 -28 S11 (db) -0.15-0.2 S11 (db) -30-32 -0.25-34 -0.3-36 -0.35 0 10 20 30 40 50 60 70 Frequency (GHz) -38-40 0 10 20 30 40 50 60 70 Frequency (GHz) 13

Calibration Options There are several options available on the test floor to calibrate your probe card The selection depends upon several factors Accuracy needed Type of Probe Card 14

TRL NIST traceable standard Calibration technique Mulit-line TRL (Thru-Reflect-Line) Uses multiple transmission lines as the standards Measurements referenced to the line impedance Limited frequency range 3 lines for 2-18 GHz Requires multiple probe spacing Not suitable for fixed spacing probes 15

Thru-Reflect-Reflect- Match (LRRM) Compares favorably to TRL In Cascade s Wincal Does not need well defined standards other than the thru Known length and impedance 16

Short-Open-Load-Thru SOLT Needs well defined standards L-short, C-open, L-load, and Thru length Uses off wafer standards Sensitive to the probe placement 17

SOLR is similar to SOLT SOLR Needs well defined Load, Short, and Open The thru does not need to be well defined, just approximate length Convenient for use with probe cards Fixed probe spacing and are usually not inline with eachother 18

2nd Tier Calibration with SOL What is 2nd Tier? 1. Calibrate to the end of the cable using standards 2. Measure SOL to generate 2 port parameters Requires reciprocal probe card (which is true for Pyramid Probes) 3. The 2-port parameters are then combined with the first calibration Does not require a thru for calibration Can be compared favorably to SOLR calibration in terms of accuracy WinCal and most VNAs have this programmed into them 19

SO Only needs Short-Open Can be done with: Probe card in air for open Probe card in contact with a metal wafer Assumes that ALL losses are due insertion losses, IE, no RL Works well down to probe cards with -12 db RL or better 20

SO Scalar Analysis Loss of DUT Loss of Probe Card by Subtraction of DUT performance Measured Probe Card and DUT 0 20 40 60 80 100 Frequency (GHz) 21

SO Can be done a few ways: Using S-parameters provided, use the loss factors as a correction term at specific frequencies Measure golden die that have been characterized using a different method (such as Infinity) that is calibrated to the tips Comparing the two measurements, the loss of the probe card is known Measurements show that the loss is repeatable and does not change much when a new core is placed in the PCB However, this is the least accurate No phase correction Is done at only a few frequencies Easiest to implement of the calibration options 22

Comparison of Methods using Thrus - Magnitude SOLT, SOLR, and LRRM are all very good Within 0.05 db of each other using the same calibration files up to 67 GHz 23

SOL Compared to LRRM SOL is reasonable for KGD testing, being within +/- 0.5 db out to 50 GHz when compared to LRRM 24

SO Comparison to SOL Short-Open works well as long as the RL is better than -12 db Because of the assumption that ALL losses are due to insertion loss 0-2 -4 Comparison of SOL and SO 0 20 40 60 80 100 120 Magnitude ( db) -6-8 -10-12 -14 SO S21 SOL Combined S11 SOL -16-18 -20 Frequency (GHz) 25

Difference in SO and SOL with RL Comparing SO and SOL, as long as RL is less than -12 db, then SO is within 1 db of SOL 8.0 7.0 Difference in SO and SOL with Return Loss 0.0-5.0 6.0-10.0 Difference Magnitude ( db) 5.0 4.0 3.0 2.0 1.0-15.0-20.0-25.0-30.0-35.0 SOL Return Loss (db) SO difference from SOL S11 from SOL 0.0-1.0-40.0 0 20 40 60 80 100 120-45.0 Frequency (GHz) 26

Comparsion of Calibration Options Calibration Method Absolute Accuracy Probe Card Support SOLT Fair Fair -due to usually not having straight thrus TRL Best Poor -due to inability to have variable length thrus LRM/LRRM Good Fair -due to usually not having straight thrus SOLR Good Best -works best with bends in thrus SOL Fair Fair Works well of KGD test SO Low Fair to Poor (Depending upon RL) Ease of use due to not needing precise alignment 27

How to Verify your Calibration? Trust me.. This depends upon the type of calibration, and how accurate For more accurate measurements SOLT, SOLR, SOL, SO Use thru Do not use short, open, or load user defined LRRM, TRL Use open or short Do not use thru user defined 28

Now Really Trust Me. For lower accuracy applications, you can consider Remeasure your standards (even if using SOLT, SOLR, and SOL) If some measurement was wrong (bad alignment;bad contact), it will appear immediately as excessive loss or gain Compare to previous measurement for system drift 29

Summary Calibration has a lot of different considerations The best option depends upon your needs and ease of setup 30

Questions? 31