4RU Rack Mountable. Solid State Power Amplifiers

Similar documents
Compact Outdoor Solid State Power Amplifiers in S-, C-, X-, and Ku-Bands

500W X-Band, 1:2 Redundant System in the 4RU chassis, with N+1 redundant power supplies

7RU SSPA Chassis. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

500W X-Band, 1:2 Redundant System in the 4RU chassis, with N+1 redundant power supplies

300W C-Band Second Generation 3RU SSPA Chassis with 1RU N+1 Power Supply

Indoor Rack Mount. GaN Solid State Power Amplifiers 3RU Rack Height

125W Ku-Band Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

328 Innovation Blvd. 1 Wheaton Road, Witham

800W C-Band Second Generation 3RU SSPA Chassis with 1RU N+1 Power Supply. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

Mini Compact Outdoor GaN SSPAs in C-, X-, and Ku-Bands

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

328 Innovation Blvd. 1 Wheaton Road, Witham

40W Ka-Band Compact Outdoor SSPA with AC Input Option B

150W Ku-Band Compact Outdoor 1:1 Redundant System. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

Phase Combined Systems

High Power Outdoor. GaAs Solid State Power Amplifiers

High Power Outdoor. GaN Solid State Power Amplifiers

High Power Outdoor. GaN Solid State Power Amplifiers

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

The New Standard in Outdoor High Power Redundant Microwave Amplifier Systems Has Arrived. Removable fan trays System is 100% field maintainable

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

The New Standard in High Power Redundant Microwave Amplifier Systems Has Arrived

The New Standard in Outdoor High Power Redundant Microwave Amplifier Systems Has Arrived. dundancy System Monitor and Control.

Ku-Band VSAT Block Up Converters

C-Band VSAT Block Up Converters

VSAT Redundant System Solutions

C-Band Redundant LNA Systems

X-Band Redundant LNA Systems

MT3200A TRAVELING WAVE TUBE MEDIUM POWER AMPLIFIER

FEATURES: Reduced Depth. Output RF Power Hold. Easily Accessible Diagnostic Port. Programmable Alarms. Event And Maintenance Logs. Ethernet Interface

Ku-Band. Reliable Designed and built to survive in extremely adverse environmental conditions. Operates in ambient temperatures up to 60 C.

Universal/Standard Ku-band 8W BUC MODEL No. NJT8318 series

328 Innovation Blvd. 2&3 The Matchyns, London Road, Rivenhall End

Universal/Standard Ku-band 8W BUC MODEL No. NJT8318 series

INTRODUCTION STANDARD FEATURES. Option: High ambient temperature operation (up to 60 C) APPLICATION KU-BAND BOOSTER AMPLIFIER

1:1 AND 1:2 REDUNDANT LOW-NOISE AMPLIFIER SYSTEMS

Universal/Standard Ku-band GaN 40W BUC MODEL No. NJT8371 series

Standard C-band 10W BUC MODEL No. NJT5762 series

KU-BAND OUTDOOR BLOCK CONVERTERS

Redundant LNA Systems

Block Upconverters for Integration in High Power Amplifiers

Universal/Standard Ku-band 16W BUC MODEL No. NJT8319 series

STA3318 Series StellarMini TM 180 W, Ku-Band Antenna Mount TWTA

Solid State Broadband High Power Amplifier

PowerMAX Redundant SSPA Systems. Soft-fail Redundancy Modular, Hot-swap Assemblies Indoor and Outdoor Packages

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

Converter VSAT Dual Band BDC ITAR Free Airborne Compact Block Down Converter MFC146

IQgig-RF TM Model B Technical Specifications

Optiva OTS-2 40 GHz Amplified Microwave Band Fiber Optic Links

Amplifier HF MHz

Solid State General Communication Power Amplifier

屋内用 SSPA パッケージ. 余裕ある高出力 : 1.1kW S-Band 1.1kW C-Band 1.0kW X-Band 500W Ku-Band ユニバーサル電圧電源力率補正型

Optiva OTS-2 18 GHz Amplified Microwave Band Fiber Optic Links

Features 100A400AM20. 4kHz 400MHz Class A Portable Full VSWR tolerant CE & RoHS compliant High Efficiency

Data Sheet SC5317 & SC5318A. 6 GHz to 26.5 GHz RF Downconverter SignalCore, Inc. All Rights Reserved

150W1000B. Features. 150 watts CW 80MHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

100U1000. Features. 100 watts CW 100kHz 1000MHz Class A Portable Full VSWR tolerant CE & RoHS Compliant High Efficiency

SC5307A/SC5308A 100 khz to 6 GHz RF Downconverter. Datasheet SignalCore, Inc.

Keysight Technologies N9320B RF Spectrum Analyzer

Agilent N9320B RF Spectrum Analyzer

Ka Band Radar Transceiver

8101 SPECIFICATION SHEET

Technical Datasheet GT-1000B Microwave Power Amplifier. 100 MHz to 20 GHz. Broadband High-Power Instrumentation Amplifier Rev.

Amplifier Systems. Ultra Low Noise LNAs. Back to. C-band LNAs X-band LNAs Ku-band LNAs

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

No. 1. BROADBAND RF-POWER-AMPLIFIERS 10 khz - 6 GHz. For immunity tests according to IEC, EN, ISO, SAE, MIL

LNS ultra low phase noise Synthesizer 8 MHz to 18 GHz

TELEDYNE MICROWAVE SOLUTIONS. Summary. NF v1. the carrier (10MHz

2 GHz to 6 GHz, 500 W Power Amplifier HMC8113

SC5407A/SC5408A 100 khz to 6 GHz RF Upconverter. Datasheet. Rev SignalCore, Inc.

Appendix A: BLC-10/20/25 DC Models Packing

IQgig-IF TM Technical Specifications

INSTALLATION AND OPERATING MANUAL

Ka-Band SSPA TSA GHz Airborne Applications

Engineering the high quality cost effective solutions. Short form selection catalogue

General. Environmental. EMC & Safety

PARADISE DATACOM APPLICATION NOTE. Satellite Terminal System Planning using L Band Modems. AN_032 Issue 2

APPH6040B / APPH20G-B Specification V2.0

ModuMAX High Power Amplifier Advancements

SIR-4011 MICROWAVE WIDEBAND DSP RECEIVER. WIDE FREQUENCY RANGE: GHz

C-band PLL LNB - Internal Reference (L.O. Stability: ±3 ppm) - MODEL No. NJS8486S/87S/88S series

120W UHF Transmitter/Repeater

SC5306B 1 MHz to 3.9 GHz RF Downconverter Core Module. Datasheet SignalCore, Inc.

GT-1000A Microwave Power Amplifier 2 GHz to 20 GHz. Broadband High-Power Instrumentation Amplifier. Preliminary Technical Datasheet

J kw AM Transmitter

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

INSTALLATION and OPERATION INSTRUCTIONS. FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV

12B01A-D30 L- & S-Band Solid State Power Amplifier w/ 1 Watt Input Drive Level

Broadcasting MSE M A G N E T I C S O U N D E N H A C E R. Passion

Isolated, Linearized Thermocouple Input 7B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated, Thermocouple Input 7B37 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Instruction Manual for Universal Ku-band 8W BUC [NJT5218 series]

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Isolated High Level Voltage Output 7B22 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

N5194A and N5192A. UXG Agile Vector Adapter 50 MHz to 20 GHz DATA SHEET

MG3740A Analog Signal Generator. 100 khz to 2.7 GHz 100 khz to 4.0 GHz 100 khz to 6.0 GHz

The DR-2000 is a high-performance receiver designed to enable highly sophisticated data and signal processing over a wide frequency spectrum.

Model 845-M Low Noise Synthesizer

RF-LAMBDA LEADER OF RF BROADBAND SOLUTIONS

Transcription:

FEATURES 600W C-Band SSPA Chassis Teledyne Paradise Datacom s Indoor, Rack Mount (R) series SSPAs represent the latest in High Power Microwave Amplifier Technology. The 4RU SSPA chassis achieves the highest power density in the industry along with enhanced maintainability. Local, front panel, control is available with a user friendly interface. Five fault condition LEDs on left side of the front panel reflect some of the SSPA major faults states, plus a summary fault indicator. The SSPA online LED turns green when the amplifier is in Online mode (1:1 Mode) or serves as an AC power indicator in standalone mode. Local/Remote and Mute/ Unmute LEDs show the current control mode and mute state of the amplifier. A full compliment of serial and parallel (contact closure) control is also available from the rear panel. Teledyne Paradise Datacom s Windows TM -based Universal M&C software allows monitor and control of the SSPA from a remote computer. A state of the art thermal platform provides efficient cooling for the amplifier module and power supplies. This ensures the highest possible MTBFs for microwave power amplifiers. Along with high reliability comes the ultimate in amplifier maintainability. Amplifier modules and power supplies are easily accessed making this one of the easiest amplifier assemblies to maintain in the field. Etremely High Power Density: S Band to 600W ; C Band to 600W; X Band to 500W ; Ku Band to 250W Removable Fan Trays Removable M&C Card RF Output Sample Port (-40 ) RF Gain Adjustment 55-75 Ethernet Port Universal, Power Factor Corrected Power Supply Built-in 1:1 Redundancy Control OPTIONS N+1 Redundant Power Supply Etended Frequency Bands L-Band Input operation ZBUC TM converter Reflected Power Monitor Phase Combined Systems Input Sample Port Ehaust Duct Adapters Redundant and Phase Combined System Solutions SPECIFICATIONS Chassis: 19.0 X 7.0 X 28.0 in 483 X 178 X 711 mm 75 lbs. / 34 kg; 100 lbs. / 45 kg for units > 250W Gray powder coat finish Operating temperature: 0 to +50 C

S-Band SSPA Power Levels Frequency Range Band A Band B 2.020 to 2.120 2.200 to 2.300 GHz GHz Output Power @: Saturation/P 1 Band A P sat /P 1 (Typical/Guaranteed minimum) HPAS2050ARXXXXX (2.020-2.090 GHz) 47.5 / 47.0 (56/50) m (W) HPAS2100ARXXXXX (2.095-2.120 GHz) 50.5 / 50.0 (112/100) m (W) HPAS2200ARXXXXX (2.020-2.090 GHz) 53.5 / 53.0 (223/200) m (W) HPAS2200ARXXXXX (2.095-2.120 GHz) 53.0 / 52.5 (200/178) m (W) HPAS2300ARXXXXX (2.020-2.090 GHz) 55.0 / 54.5 (316/280) m (W) HPAS2300ARXXXXX (2.095-2.120 GHz) 54.4 / 54.0 (280/250) m (W) HPAS2400ARXXXXX (2.020-2.090 GHz) 56.5 / 56.0 (447/400) m (W) HPAS2400ARXXXXX (2.095-2.120 GHz) 56.0 / 55.5 (400/355) m (W) HPAS2500ARXXXXX (2.020-2.090 GHz) 57.2 / 57.0 (525/500) m (W) HPAS2500ARXXXXX (2.095-2.120 GHz) 56.7 / 56.5 (468/447) m (W) HPAS2600ARXXXXX (2.020-2.090 GHz) 58.0 / 57.5 (631/560) m (W) HPAS2600ARXXXXX (2.095-2.120 GHz) 57.5 / 57.0 (560/500) m (W) Band B HPAS2050BRXXXXX (2.200-2.300 GHz) 47.5 / 47.0 (56/50) m (W) HPAS2100BRXXXXX (2.200-2.300 GHz) 50.5 / 50.0 (112/100) m (W) HPAS2200BRXXXXX (2.200-2.300 GHz) 53.5 / 53.0 (223/200) m (W) HPAS2300BRXXXXX (2.200-2.300 GHz) 55.0 / 54.5 (316/280) m (W) HPAS2400BRXXXXX (2.200-2.300 GHz) 56.5 / 56.0 (447/400) m (W) HPAS2500BRXXXXX (2.200-2.300 GHz) 57.2 / 57.0 (525/500) m (W) HPAS2600BRXXXXX (2.200-2.300 GHz) 58.0 / 57.5 (631/560) m (W) Power Requirements Line Voltage power factor corrected 47 to 63 Hz Line Frequency HPAS2050A/BRXXXXX (90 to 265 VAC) 250 W Line Power HPAS2100A/BRXXXXX (90 to 265 VAC) 500 W HPAS2200A/BRXXXXX (180 to 265 VAC) 1000 W HPAS2300A/BRXXXXX (180 to 265 VAC) 1600 W HPAS2400A/BRXXXXX (180 to 265 VAC) 1800 W HPAS2500A/BRXXXXX (180 to 265 VAC) 3500 W HPAS2600A/BRXXXXX (180 to 265 VAC) 3800 W Receive Band Reject Filter Filter integrated into SSPA chassis through 400W Output; 500W and 600W SSPAs require an eternal filter. Receive Band Noise Power Density Receive Band Noise and Filter Option Insertion Loss (Sub-Bands A & B) R Reject @ 2.200 GHz (Sub-Band A) R Reject @ 2.025-2.120 GHz (Sub-Band B) Without optional filter With optional filter - 0.5-60 - 60-95 -155 c c w/4 KHz w/4 KHz 2 OF 11 201355 REV AE ECO 16990

C-Band SSPA Power Levels Frequency Range (see options for etended band) 5.850 to 6.425 GHz Output Power @: Saturation/P 1 P sat / P 1 (Typical/Guaranteed minimum) HPAC2050ARXXXXX 47.0/46.8 (50/48) m (W) HPAC2075ARXXXXX 48.8/48.5 (76/70) m (W) HPAC2100ARXXXXX 50.0/49.5 (100/89) m (W) HPAC2140ARXXXXX 51.5/51.0 (141/126) m (W) HPAC2200ARXXXXX 53.0/52.3 (200/170) m (W) HPAC2250ARXXXXX 53.9/53.0 (250/200) m (W) HPAC2300ARXXXXX 54.7/54.0 (300/251) m (W) HPAC2400ARXXXXX 56.0/55.0 (400/316) m (W) HPAC2500ARXXXXX 57.0/56.0 (500/400) m (W) HPAC2600ARXXXXX 57.8/57.0 (600/500) m (W) Power Requirements Line Voltage power factor corrected AC input Line Frequency 47 to 63 Hz Line Power HPAC2050ARXXXXX (90 to 265 VAC) 400 W HPAC2075ARXXXXX (90 to 265 VAC) 450 W HPAC2100ARXXXXX (90 to 265 VAC) 650 W HPAC2140ARXXXXX (90 to 265 VAC) 850 W HPAC2200ARXXXXX (180 to 265 VAC) 1000 W HPAC2250ARXXXXX (180 to 265 VAC) 1300 W HPAC2300ARXXXXX (180 to 265 VAC) 1700 W HPAC2400ARXXXXX (180 to 265 VAC) 2400 W HPAC2500ARXXXXX (180 to 265 VAC) 2800 W HPAC2600ARXXXXX (180 to 265 VAC) 3700 W Frequency Options Etended Frequency Bands 5.850 to 6.725 GHz De-rate output power by 1.0 linearly from 6.425 to 6.725 GHz 5.75 to 6.67 GHz De-rate output power by 1.0 linearly from 6.425 to 6.67 GHz and by 0.5 from 5.85 to 5.75 GHz 3 OF 11 201355 REV AE ECO 16990

X-Band SSPA Power Levels Frequency Range (see options for etended band) 7.90 to 8.40 GHz Output Power @: Saturation/P 1 P sat / P 1 (Typical/Guaranteed minimum) HPAX2060ARXXXXX 47.5/47.3 (60/54) m (W) HPAX2075ARXXXXX 48.8/48.3 (76/68) m (W) HPAX2100ARXXXXX 50.0/49.5 (100/89) m (W) HPAX2140ARXXXXX 51.4/50.8 (140/120) m (W) HPAX2200ARXXXXX 53.0/51.8 (200/170) m (W) HPAX2250ARXXXXX 54.0/53.3 (250/214) m (W) HPAX2350ARXXXXX 55.5/54.5 (354/282) m (W) HPAX2500ARXXXXX 57.0/56.0 (500/400) m (W) Power Requirements Line Voltage power factor corrected AC input Line Frequency 47 to 63 Hz Line Power HPAX2060ARXXXXX (90 to 265 VAC) 650 W HPAX2075ARXXXXX (90 to 265 VAC) 700 W HPAX2100ARXXXXX (90 to 265 VAC) 750 W HPAX2140ARXXXXX (180 to 265 VAC) 1225 W HPAX2200ARXXXXX (180 to 265 VAC) 1370 W HPAX2250ARXXXXX (180 to 265 VAC) 2450 W HPAX2350ARXXXXX (180 to 265 VAC) 3000 W HPAX2500ARXXXXX (180 to 265 VAC) 3500 W Frequency Options Etended Frequency Band 7.70 to 8.40 GHz De-rate output power by 1.0 linearly from 7.90 to 7.70 GHz 7.50 to 8.50 GHz 4 OF 11 201355 REV AE ECO 16990

Ku-Band SSPA Power Levels Frequency Range (see options for etended band) 14.00 to 14.50 GHz Output Power @ Saturation/P 1 P sat / P 1 (Typical/Guaranteed minimum) HPAK2025ARXXXXX 44.0/43.0 (25/20) m (W) HPAK2035ARXXXXX 45.5/44.5 (35/28) m (W) HPAK2040ARXXXXX 46.0/45.0 (40/31) m (W) HPAK2050ARXXXXX 47.0/46.0 (50/40) m (W) HPAK2070ARXXXXX 48.5/47.5 (70/56) m (W) HPAK2100ARXXXXX 50.0/49.0 (100/80) m (W) HPAK2125ARXXXXX 51.0/50.0 (125/100) m (W) HPAK2200ARXXXXX 53.0/52.0 (200/158) m (W) HPAK2250ARXXXXX 54.0/53.0 (250/200) m (W) Power Requirements Line Voltage power factor corrected AC input VAC Line Frequency 47 to 63 Hz Hz Line Power HPAK2025ARXXXXX (90 to 265 VAC) 320 W HPAK2035ARXXXXX (90 to 265 VAC) 350 W HPAK2040ARXXXXX (90 to 265 VAC) 500 W HPAK2050ARXXXXX (90 to 265 VAC) 500 W HPAK2070ARXXXXX (90 to 265 VAC) 550 W HPAK2100ARXXXXX (180 to 265 VAC) 1100 W HPAK2125ARXXXXX (180 to 265 VAC) 1200 W HPAK2200ARXXXXX (180 to 265 VAC) 2500 W HPAK2250ARXXXXX (180 to 265 VAC) 2800 W Frequency Options Etended Frequency Band 13.75 to 14.50 GHz De-rate output power by 1.0 linearly from 14.00 to 13.75 GHz 5 OF 11 201355 REV AE ECO 16990

Common Electrical Specifications Gain Gain Flatness Gain Slope Gain Variation vs. Temperature Gain Adjustment minimum full band Etended C-Band units per 40 MHz (C, X, Ku) Per 10 MHz (S-band) 0 C to +50 C 0.1 resolution 75 ±1.0 ±1.5 ±0.3 ±0.2 ±1.0 20 /40 MHz /10 MHz Intermodulation Distortion 3 back off relative to P 1-25 c AM/PM Conversion (@ rated P 1 ) (@P 1-3) Spurious Harmonics Input/Output VSWR (@ rated P 1 ) (@ rated P 1-3) (C-,X-,Ku-bands) (@ rated P 1-3) (S-Band) All units ecept Etended C-Band Etended C-Band units 3.5 1.0-70 -50-40 1.30:1 1.50:1 Noise Figure at maimum gain 12 Group Delay Linear Parabolic Ripple 0.01 0.003 1.0 ns/mhz ns/mhz 2 ns p-p Noise Output Residual AM Noise Residual Phase Noise Connectors TX Band (S, C-, X- or Ku-Band) RX Band (C- or Ku-Band) RX Band (X-Band) RX Band (S-Band; see page 2) 0-10 KHz 10 KHz - 500 KHz 500 KHz - 1 MHz Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz RF Input, Input & Output Sample RF Output: HPAS2XXXRXXXXX RF Output: HPAC2XXXRXXXXX RF Output: HPAX2XXXRXXXXX RF Output: HPAK2XXXRXXXXX Line Power -75-150 -100-45 -20 (1.25 + log F) -80-90 -100-110 -120-125 -130 Type N Type N WR137 Waveguide WR112 Waveguide WR75 Waveguide (90-265) IEC 6100-3300 (180-265) IEC 4798-9000 Mechanical Size width X height X depth 19.0 X 7.0 X 28.0 483 X 178 X 711 o / o / c c c W/4 KHz W/4 KHz W/4 KHz c c c Female Female CPR137G Flange (PDR-70) CPR112G Flange (PDR-84) Grooved Flange (PBR-120) Plug Plug inches mm Weight 250W Chassis 75 (34) lbs.(kg) > 250W Chassis 100 (45) lbs.(kg) Finish powder coat Gray Environmental Specifications Operating Temperature Ambient 0 to +50 C Relative Humidity non-condensing 95 % Cooling System Integrated Forced air Specifications are subject to change. 6 OF 11 201355 REV AE ECO 16990

L-Band Operation Teledyne Paradise Datacom offers C-, X-, and Ku-Band amplifiers with an integrated L-Band Block Up Converter. The L-Band units utilize Teledyne Paradise Datacom s proprietary ZBUC TM technology. The addition of a ZBUC converter to a 4RU Rack Mountable SSPA typically increases the gain by 2-4. The advantages of ZBUC TM technology include: ZBUC converters can detect and switch to an etenally supplied reference. Optional internal high stability (10MHz) reference. ZBUC converters can lock to an eternally supplied reference of 5, 10, 20, 25, or 50 MHz without modification. ZBUC converters can accept a wide range of eternal reference power (-10 to +5 m) ZBUC converters can accept FSK monitor and control signal via the IFL for complete amplifer remote control. Available Frequency Plans Band Frequency Band IF Input LO Frequency RF Output Gain Change C Standard C-Band 950-1525 MHz 4.900 GHz 5.850-6.425 GHz 0-4 C Etended C-Band 950-1825 MHz 4.900 GHz 5.850-6.725 GHz 0-4 C Palapa Band 950-1250 MHz 5.475 GHz 6.425-6.725 GHz 0-4 C Insat Band 950-1250 MHz 5.775 GHz 6.725-7.025 GHz 0-4 C Etended C-Band 2 950-1675 MHz 4.800 GHz 5.750-6.475 GHz 0-4 X Standard X-Band 950-1450 MHz 6.950 GHz 7.900-8.400 GHz 0-2 Ku Standard Ku-Band 950-1450 MHz 13.050 GHz 14.00-14.50 GHz 0-2 Ku Etended Ku-Band 950-1700 MHz 12.800 GHz 13.75-14.50 GHz 0-2 Electrical Specifications for 4RU RM SSPA with ZBUC converter Gain Nominal setting 75 Gain Flatness full band (C-,X-,Ku-bands) r2.0 Gain Slope per 40 MHz (C-,X-,Ku-bands) r0.5 /40 MHz Gain Adjusted Range 20 Typical C-Band Adj. Range Typical Ku-Band Adj. Range 60-80 57-77 Gain Stability 0 to +50 C r1.5 Phase Noise Offset frequency from carrier 10 Hz 100 Hz 1 KHz 10 KHz 100 KHz 1 MHz Absolute ma. -30-60 -70-80 -90-90 C-band (typ.) -60-80 -80-85 -120-125 X-band (typ.) -60-75 -75-100 -110-122 Ku-band (typ.) -50-65 -72-90 -110-120 Spurious In-Band Signal Related (C-/Ku-Band) -50 c (Etended C-Band) -40 c Close to Carrier Spurious ( 20 MHz) -50 c Local Oscillator -30 m Noise Figure At 75 gain setting 20 Input VSWR L-Band 1.5 : 1 Internal Reference Option Reference accuracy @ 25 C Reference Stability over Temperature (-40 to +90 C) ±1 10-7 ±1 10-8 7 OF 11 201355 REV AE ECO 16990

HPAC-2600 600W C-BAND POWER RF INPUT SAMPLE RF OUTPUT SAMPLE RF OUT J2 AC IN J10 MODEL: XXXXXXXXXXXX S/N: XXXX P/N: LXXXXXX-X J12 PS M&C J1 4RU Rack Mountable DATACOM PARADISE Outline Drawing, 4RU SSPA with Integral Power Supply 8 OF 11 201355 REV AE ECO 16990

Redundant Power Supply Option The combination of a separate +12 VDC output, fully redundant power supply is an ecellent means of obtaining the ultimate system reliability. The power supply is an N+1 redundant configuration meaning that there is one more power supply module available than is required to operate the SSPA. A failure of one power supply module will not take the amplifier off-the-air. In addition the power supply modules are removable from the front panel while in operation. There is never a need to remove the power supply chassis from the equipment rack. Weighing only 9 lbs. (4 kg) and occupying only 1 rack unit of cabinet space, the redundant power supply chassis is an ecellent companion to the SSPA chassis. The power supply has a single phase, universal AC input ranging from 90-265 VAC, 47-63 Hz. It is power factor corrected to 0.99. Depending on the power requirements of the SSPA, the power supply is configured with two, three or four 1200W hot-swappable modules, each of which weighs 5 lbs. (2.3 kg). 9 OF 11 201355 REV AE ECO 16990

PARADISE DATACOM HPAK-2250 250W Ku-BAND POWER SAMPLE RF INPUT SAMPLE RF OUTPUT -12VDC IN RF OUT J2 +12VDC IN MODEL: XXXXXXXXXXXX S/N: XXXX P/N: LXXXXXX-X J12 PS M&C J1 4RU Rack Mountable Outline Drawing, 4RU SSPA with N+1 Redundant Power Supply 10 OF 11 201355 REV AE ECO 16990

Part Number Configuration HPA 2 R X Band S - S-Band C - C-Band X - X-Band K - Ku-Band Power Level (in Watts) S-Band 050, 100, 200, 300, 400, 500 or 600 C-Band 050, 075, 100, 140, 200, 250, 300, 400, 500 or 600 X-Band 060, 075, 100, 140, 200, 250, 350 or 500 Ku-Band 025, 035, 040, 050, 070, 100, 125, 200 or 250 Frequency Sub Band S-Band A - 2.02 to 2.12 GHz B - 2.20 to 2.30 GHz C-Band A 1 5.850 to 6.425 GHz B 1 5.850 to 6.725 GHz C 5.750 to 6.670 GHz E 1 6.425 to 6.725 GHz (Palapa) F 1 6.725 to 7.025 GHz (Insat) G 1 5.750 to 6.475 GHz V 1, 2 5.850 to 6.725 GHz X-Band A 1-7.90 to 8.40 GHz B - 7.50 to 8.50 GHz C - 9.50 to 10.50 GHz D - 7.70 to 8.40 GHz Ku-Band A 1 14.00 to 14.50 GHz B 1 13.75 to 14.50 GHz 1 Available with optional BUC 2 With VSWR of 1.3:1 Configuration Modifier XXX = Standard CXX 1 = Input Sample & 110/220 VAC Operation KXX 1 = 110/220 VAC Operation SXX = Input Sample XVX = Reflected Power Monitor XXD = 48V Input XXE = Rear Panel Ehaust Adapters XXH 2 = 48V Input & Receive Band Reject Filter XXJ = 48V Input & Rear Panel Ehaust Adapters XXK 2 = Rear Panel Ehaust Adapters & Receive Band Reject Filter XXL = Eternal 1RU N+1 Power Supply & Rear Panel Ehaust Adapters XXM 2 = Eternal 1RU N+1 Power Supply & Receive Band Reject Filter XXP = Eternal 1RU N+1 Power Supply XXR 2 = Receive Band Reject Filter 1 100-125W Ku- & 200-300W C-Band only; Consult factory for S- & X-Bands. 2 S-Band only System Configuration X = Standalone See the following datasheets for system options: Indoor Rack Mount Redundant SSPA Systems (203583) Indoor Rack Mount Phase Combined SSPA Systems (203584) Block Up Converter B = BUC (Custom) M = Internal Reference ZBUC P = Eternal Reference ZBUC X = N/A Package R = Rack Mount (Standalone) Eample - A standalone 100W Etended Ku-Band Rack Mount SSPA with an optional 48 VDC input and no block up converter is part number: HPAK2100BRXXXXD. Specifications listed in this document are subject to change without notice. X-Band products may be subject to ITAR restrictions and should not be eported from the U.S. without obtaining proper licensing from the appropriate government agencies. 11 OF 11 201355 REV AE ECO 16990