Capacitor overvoltage protection function

Similar documents
Residual instantaneous overcurrent protection function block description

Three-phase instantaneous overcurrent protection function block description

Directional three-phase overcurrent protection function block description

Document ID: PRELIMINARY VERSION

Overexcitation protection function block description

Centralized busbar differential and breaker failure protection function

Automatic reclosing function for high voltage networks

High speed bus transfer function block description Operation Manual

Restricted earth-fault protection function block description

Teleprotection function

INSTRUCTION MANUAL. AQ F3x0 Feeder protection IED

Distributed busbar differential protection function and breaker failure protection

UV3 _ Three-Phase Undervoltage Protection Low-Set Stage (UV3Low) High-Set Stage (UV3High)

POWER CORPORATION. Power Quality. Specifications and Guidelines for Customers. Phone: Fax:

PQVO3Sd Short duration voltage variations

Symmetrical Components in Analysis of Switching Event and Fault Condition for Overcurrent Protection in Electrical Machines

SixPac Series of SCR AC Controller and DC Converters

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters

HVR. Lead Wire Length (H, mm)

MotStart Three-phase Start-Up Supervision for Motors

PRODUCT / TEST MANUAL 2V162K4 VOLTAGE REGULATOR RELAY

GS1 Parameter Summary Detailed Parameter Listings...4 9

PRODUCT/TEST MANUAL 2V162K12 VOLTAGE REGULATOR RELAY

Inrush3 Three-Phase Transformer Inrush and Motor Start-Up Current Detector

POWER QUALITY SPECIFICATIONS AND GUIDELINES FOR CUSTOMERS ENGINEERING STANDARDS CITY OF LETHBRIDGE ELECTRIC

Power Quality Basics. Presented by. Scott Peele PE

EN50160 Individual Report Summary

Power Quality and Digital Protection Relays

Technical Reference Notes AIT00ZPFC-01NL. AIT00ZPFC 150W AC-DC Converter Module

PROFINET USER S GUIDE ACSI Servo

ALPTEC POWER FACTOR CONTROLLER

www. ElectricalPartManuals. com Transformer Differential Relay MD32T Transformer Differential Relay

ENHANCE SWITCHING POWER SUPPLY SPECIFICATION 250 WATT MODEL NO:V525

Overcurrent Protection / 7SJ45

PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2)

Single Switch Forward Converter

Power supply circuit Through an external power supply unit V ac / 12 V dc. Operating temperature ºC. Humidity of operation

PQVO3H Voltage Waveform Distortion Measurement

Analog Servo Drive. Peak Current 16 A (11.3 A RMS )

HVDC CAPACITOR COMMUTATED CONVERTERS IN WEAK NETWORKS GUNNAR PERSSON, VICTOR F LESCALE, ALF PERSSON ABB AB, HVDC SWEDEN

STEF12. Electronic fuse for 12 V line. Description. Features. Applications

Roadmap For Power Quality Standards Development

1 INTRODUCTION 1.1 PRODUCT DESCRIPTION

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

6.9 Jump frequency - Avoiding frequency resonance

Model ipm Intelligent Power Monitor

Technical Brief: Flow Direction of Harmonics and High- order Harmonics

Southern Company Power Quality Policy

LM2240 Programmable Timer Counter

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

Product Specification

Matrix Power Company MH xxx-va series Specification Document

PM 6669 High-Precision Frequency Counter Specifications

D I G I T A L V O L T A G E R E G U L A T O R

Capacitor protection relay

Product Specification

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Model Number Structure

IEEE sion/1547revision_index.html

Harmonic control devices. ECE 528 Understanding Power Quality

LM2935 Low Dropout Dual Regulator

ESB National Grid Transmission Planning Criteria

Scope of functions 32R

IR2175(S) & (PbF) LINEAR CURRENT SENSING IC

LC35/2-DA-iC. 35 W Dimmable two channel intelligent Colour LED driver. 35 W V 0 / Hz. Functional Description. Mains Characteristics

Power Quality Improvement using Hysteresis Voltage Control of DVR

Exercises. 6 Exercises

POWER-GATE Non-Programmable OR ING (Generation 4.0) Application Sheet

MIC29150/29300/29500/29750 Series

Electronic Circuit Protector ESX10-T

CHAPTER 6 DIGITAL INSTRUMENTS

PAM & SAM System User s Manual

function block description to the differential protection and restricted earth-fault protection functions for autotransformers

13. Before making a service call Trip information and remedies

Energy Metering IC with On-Chip Fault Detection AD7751*

POWER QUALITY REPORT

Low voltage products in high altitudes

User Manual 3X300 DIMMER MODULE DM03B02KNX

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

Power Analysis Summary

DESCRIPTION NOTE. Power Supply MODEL 2200A PM

PARAMETER LIST PARAMETER LIST

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

Protection and control. Sepam range Sepam 2000 Metering and protection functions

Analog Servo Drive. Continuous Current. Features

Replacement solution

0MPV 8016 S00 / 0MPV 5016 S00 Prototype Manual

VOLTAGE REGULATOR R 449. Installation and maintenance. This manual must be sent to the end user R 449 X2 Z1 X1 Z2 E+ E- (12V - 10A)

Requirements for Offshore Grid Connections. in the. Grid of TenneT TSO GmbH

Semiconductor (AC) fuses

AS ma Low Drop Out Voltage Regulator

POWER QUALITY A N D Y O U R B U S I N E S S THE CENTRE FOR ENERGY ADVANCEMENT THROUGH TECHNOLOGICAL I NNOVATION


LIMITS FOR TEMPORARY OVERVOLTAGES IN ENGLAND AND WALES NETWORK

Programmable Voltage Clamp

Application Guide High Impedance Differential Protection Using SIEMENS 7SJ602

Transcription:

Budapest, May 2018.

User s manual version information Version Date Modification Compiled by 1.0 2012-10-10 First edition Gyula Poka Kornel Petri 1.1 2018-05-30 Minor corrections Erdős VERSION 1.1 2/5

Capacitor overvoltage protection function The power frequency voltage of a network can be high due to voltage fluctuation and regulation or due to the voltage rise at light load. The shunt capacitors connected to the network need protection against high steady state voltage, because the voltage over the rated level accelerates the aging of the material inside the capacitor. A moderated overvoltage can be tolerated for a relatively long time; the high overvoltages however need fast disconnection. The characteristic of this overvoltage protection function is a certain kind of inverse type characteristics, defined in international standards (IEC 60871-1 Shunt capacitors for a.c. power systems having a rated voltage above 1000 V - Part 1: General, or ANSI/IEEE C37.99 Capacitor Banks, Guide for Protection of Shunt). The function has additionally a definite time warning stage, the setting of which is independent of that of the inverse type tripping stage. The capacitors on a network in most cases have no dedicated voltage measurement, the voltage transformers on the busbar measure voltage even in disconnected state of the capacitors. To avoid these kinds of problems, this protection function measures the currents in the phases of the capacitor, and calculates the voltages in the phases independently. The warning and trip decision is based on the calculated voltage values. The phase voltages as a function of the time can be calculated by integration of the current time function of the phases: This integral, which is evaluated using a simple numerical method, considers also the higher harmonic contents of the current up to the 10 th harmonic. All harmonics with higher ordinal number are filtered out. The function does not consider the transient values caused by switching procedures, these values are filtered out. The decision is based on the steady state values, since the time delay can be several minutes, and only the symmetrical peak values are considered. The calculated and found peak values are related to the rated power frequency peak voltage. If the voltage is above the setting value then the time is weighted according to the inverse type characteristic, and based on the time multiplier setting (K). These values are added (accumulated). If this accumulated time exceeds the limit, the function generates the trip command. The international standards (IEC 60871-1 or ANSI/IEEE C37.99, see above) define the operate time, as the maximum duration for some values of the power frequency voltage. Based on these standards the characteristic is defined on the following discrete values (these admissible voltage level in service shown in Table below): Voltage factor * UN V R.M.S. Maximum duration defined in the standards 1 Continuous 1.15 30 min in every 24 h 1800 s 1.2 5 min 300 s 1.3 1 min 60 s 1.4 15 s 15 s 1.7 1 s 1 s 2.0 0.3 s 0.3 s 2.2 0.12 s 0.12 s Maximum duration in seconds Additionally the characteristic can be modified by the time multiplier setting (K). VERSION 1.1 3/5

According to the standards, the amplitudes of the overvoltages that may be tolerated without significant deterioration of the capacitor depend on: their total duration, their total number and the capacitor temperature. The total duration of the overvoltage is covered by the accumulation. The number of the overvoltages is considered in this protection function as follows: If the voltage peak is above 1.1 * UNpeak then additionally to the accumulation, a reset time measurement is started. Then If the accumulated value reaches the trip value then the trip command is generated. If the voltage peak drops below 1 * UNpeak then both the integral and the reset time measurement reset to zero. If the voltage peak drops below 1.1 * UNpeak but above 1 * UNpeak then the integral is frozen, and the reset time keeps on counting. In this state o If the voltage peak is above 1.1 * UNpeak again then the accumulation is going on starting with the frozen value. o If the reset time measurement gets above the reset time setting without trip generation then both the integral and the reset time measurement reset to zero. Concerning the effect of the ambient temperature, this simple protection function does not include direct ambient temperature measurement. It is the task of the user to set the appropriate time multiplier value (K), to accelerate the trip command for the worst case expected temperature (or delay the trip command if the ambient temperature is continuously below the rated temperature of the capacitor type test). This protection function has additionally a definite time warning stage, the setting of which is independent of that of the inverse type tripping stage. VERSION 1.1 4/5

Technical data Function Value Accuracy Pick-up starting accuracy < 1% Operate time accuracy at In=100 % < 5% Parameters Enumerated parameters Parameter name Title Selection range Default Enabling or disabling the capacitor overvoltage protection function CapOV_Oper_EPar Operation Off, On On Integer parameter Parameter name Title Unit Min Max Step Default Capacitor nominal current, related to the rated current of the current transformer. The integral of this current defines the nominal basic harmonic voltage, the peak value of which is the reference for overvoltage detection. CapOV_NomCurr_IPar_ Rated current % 15 120 1 100 Value of the overvoltage, related to the rated voltage of the capacitor, to start the warning stage of the function CapOV_I2Start_IPar_ Warning Start % 80 120 1 100 Reset time setting for Stage 1 CapOV_Reset_IPar_ Reset Time sec 1 60000 1 3600 Definite time delay for Stage 2 CapOV_Delay2_IPar_ Warning Delay sec 1 3600 1 60 Floating point parameter Parameter name Title Dim. Min Max Step Default Time multiplier for the inverse type characteristic CapOV_K_FPar_ Time Multiplier - 0.20 2.00 0.01 1.00 Binary output status signals Binary output status signals Signal title Explanation CapOV_Str1L1_GrI_ Start1 L1 Start of Stage 1 in phase L1 CapOV_Str1L2_GrI_ Start1 L2 Start of Stage 1 in phase L2 CapOV_Str1L3_GrI_ Start1 L3 Start of Stage 1 in phase L3 CapOV_Str2L1_GrI_ Start2 L1 Start of Stage 2 in phase L1 CapOV_Str2L2_GrI_ Start2 L2 Start of Stage 2 in phase L2 CapOV_Str2L3_GrI_ Start2 L3 Start of Stage 2 in phase L3 CapOV_Trip1_GrI_ Trip1 Trip command of Stage 1 CapOV_Trip2_GrI_ Trip2 Trip command of Stage 2 (usually assigned as Warning) Binary input status signals The conditions of the binary input signal are defined by the user, applying the graphic logic editor. Binary input status signal Title Explanation CapOV_Blk_GrO_ Block Output status of a graphic equation defined by the user to disable the capacitor overvoltage protection function. VERSION 1.1 5/5