CALEFFI. Electronic thermal control system for radiators. 210 series 01263/15 GB. RADIO WAVE system

Similar documents
LK Wireless Room Control Cq

Wireless temperature controller E N RFTC-50/G

Mx-RPW Room Control Module (Built-In Occupancy Sensor)

PRODUCT CATALOGUE TEMPERATURE CONTROL Grässlin products for individual control of temperature

INSTAT 868 Radio Frequency Single-Room Controls

Wireless Room Thermostat Installation and Operation Y6630D1007

Radio controllers. Innovation combined with skill and tradition. Intelligent solutions. for all living spaces. Radio-controlled regulation

User Instructions For TopTronic RS-10

NRT 105: Electronic fan-coil controller, equiflex

Radiocontrol F. Floor Heating Controller Radio control system for floor heating

Control solutions Biofloor

VIESMANN. Installation and service instructions VITOTROL 300 RF. for contractors. Vitotrol 300 RF

WIRELESS CONTROL UNIT FOR CONTROL OF ELECTRIC HEATING DEVICES (WITHIN ONE ROOM)

LP20RF & DIGISTAT+RF. Installation & User Guide PRINT. Radio frequency controlled room thermostat with dual channel programmer. Part number RF562DR

* _Ver.1* GP8 Radio CPL Radio DRIVER Energy manager

MECHANICAL RF STAT INSTRUCTION MANUAL MECHANICAL RF STAT TRANSMITTER & RECEIVER FITTING & OPERATING INSTRUCTIONS

Thank you for purchasing this product. If installing for someone else, please ensure that the instructions are handed to the householder.

Control module 2 circuits AD290. Installation and Service Manual

AHC-XP. Dewpoint-guided Power Controller for Glass and Handrail Heaters. Front view. Characteristics

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

Use of the application program. Contents. 1. Functional description General. GAMMA instabus Application program description.

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

Thermostat P. Thermostats Electronic room thermostat with clock for thermal actuators

S-Series Digital Thermostat

Digital Electronic Thermostat With RF

Ambient Weather WS-0270 Wireless Indoor / Outdoor Thermometer with Indoor Humidity User Manual

INSTRUCTION MANUAL DT10RF OPTIMISING PROGRAMMER UK/IE OPERATING AND INSTALLATION

Mx-D15 Intelligent Valve Actuator

RADIO DRIVER. * _Rev.1* Installation guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones

Overview of types. Technical data

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

The CM Range. Clearly different

alfariss ayros forteco PLUS 24V actuator for domestic sliding gates weighing up to 300 kg

Series 10-ZSE80/10-ISE80

Quick Start: Radiator Control

CM927 WIRELESS PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

RX-100. Drahtloser Programmierbarber Thermostat Betriebs-, Reinigungsund Wartungsanleitung für den INSTALLATEUR und den BENUTZER

IntesisBox ME-AC-ENO-1 / 1C v.1.0.9

SECO-LARM. SECO-LARM U.S.A., INC Millikan Avenue Irvine, CA FILE:MTSP35E35EV.pmd\08/12/2005

Room Temperature Controllers. for heating and cooling systems

Self-learning Room Temperature Controller Receiver

Ultrasonic level transmitter, non-contact

B 520 ELECTRONIC AMBIENT TEMPERATURE CONTROLLERS. RTB C2 Eng. COSTER BUS. B RTB C2 Eng MC REV 01

Digimax 210. Programmable Thermostat. User Guide

Wireless sensor system

IMMS-SI. Communications Site Interface. Installation Instructions. IMMS Site Interface. To Controller From CCC. From Sensors. To First CI REM SEN SEN

Room Temperature Controllers. for heating and cooling systems

Wireless multizone receiver RDE-MZ6

Room Temperature Controllers. for heating and cooling systems

Radio Controlled timekeeping. Receives 60KHz WWVB signal transmitted by NIST in Fort Collins, Colorado

Installation Guide. ECL Comfort 310, application A Table of Contents

Room Temperature Controllers. for heating and cooling systems

Room Sensors. for relative humidity and temperature

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

RUND Decorative Column

16-Channel Yearly Time Switch TR 648 S DCF

LMLR-710 (Plug-in type door chime receiver) LMLT-711 (push unit door chime transmitter)

Air Quality Sensor KNX AQS

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

Wireless Control Systems

Digital inductive conductivity transmitter

EBERLE THERMOSTAT & RECEIVER

Wireless CO 2. + TRH Sensor. Installation Guide. Version 1

Contents. Page English 1. French. Spanish. Reset of MIN/MAX records 915 MHz Reception Mounting Care and Maintenance Warranty Information

Battery-Free Wireless Pushbutton Useful Tips for Reliable Range Planning

Installation Guide. ECL Comfort 310, application A Table of Contents

ENGLISH PORTUGUÊS NEDERLANDS DAB200

Light Management Systems for Indoor Use MULTISENSORS

User Manual OFF ON IN OUT ALARM RESET AURATON RTH software ver. F0F

GUIDE SPECIFICATIONS CONTROLS SPECIFICATIONS AND CONTROL POINT DATA MAP GENERAL DESCRIPTION

Communicative heating controller

Technical Application Guide

Radio technology for home automation

Technical data lumina MS4/RC

JUMO Wtrans Receiver with Wireless Data Transmission

Wireless Network Manager (NM) and Wireless Transceiver (TRV)

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

P2P 2 YEAR PL-VDIO-05. Smartphone Connect IP VIDEO DOOR PHONE QUICK START GUIDE 7 VIDEO DOOR PHONE SYSTEM WITH SMARTPHONE CONNECT

Taxonomies, Classifications, and Categories Residential dimmers, motion sensors, controls, & photo cells Wireless occupancy/vacancy sensor

WIRELESS Energy Monitor - Smart Meter

Instruction manual ADN-W AM. Antenna Module

CM900. Our innovative Line of Text (LoT ) display makes the thermostat extremely easy to use. The unique design means that your CM900 is: Easy to read

Meade Instruments Corp Personal Weather Station With Atomic Clock (RCW33W)

Digital Wireless Weather System

EU Series Consumer Mobile Signal Booster Single Band (GSM/DCS/WCDMA/LTE800/LTE1800/LTE2600) Dual Band (ED/EW/DW/L800/L2600)

Technical Guide for Radio-Controlled Advanced Wireless Lighting

TAC 2112 Manual (GB),

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

RAMSES 784 HF Set 1. Bedienungsanleitung Uhrenthermostat 1. Operating Instructions Clockthermostat 14. Mode d emploi Thermostat à horloge 26

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

The transducer component converts the measured signal and displays the actual value.

DIN Rail Time & Twilight Switches

Technical data. Parameterisable damper actuator in the

HEAT COST ALLOCATORS HYDROCLIMA OPTO HYDROCLIMA RFM. Remote reading heat cost allocators. Optical reading heat cost allocators

LCC1653, LCC1656, LRI1653 Datasheet ActiLume DALI System

2025 RTH 2025 P 2025 OFF ON IN OUT ALARM RESET

Room Temperature Controller

multiscan Radio fingerprint scanner NB870N with master radio keys Installation and operation instructions

Rolyan Splint Pan OPERATION MANUAL. Item # Small Item # Large

Wireless Ceiling Mount Sensor

Transcription:

Electronic thermal control system for radiators 210 series LEFFI 0126/15 G REDITED ISO 9001 FM 21654 RDIO WVE system Function The radio wave thermal control system is composed of: - multi-zone thermal controller code 210100 - electronic control head for radiator valve code 210510 - ambient temperature sensor (optional) code 210001 The thermal controller manages the temperature in the various rooms by controlling the electronic actuators installed on the valves of the individual heating bodies. The actual temperature is measured by the sensors positioned in the room and/or integrated in the control heads. Depending on the set temperature parameters and the comfort or set back cycles, the controller sends a modulating opening or closing signal to the actuators and turns the boiler on and off. The actuators are controlled by means of radio wave transmission. Quick-coupling installation with adaptor. Product range 210100 Radio wave multi-zone thermal controller, with power supply unit. 210510 Radio wave electronic control head. For thermostatic and convertible radiator valves. 210001 Radio wave ambient temperature sensor. For temperature control of the individual zone or room. 210004 Power supply unit for thermal controller. 210005 Tamper-proof kit. 210011 Wireless radio signal repeater with plug for power outlet. 210010 Wireless radio signal repeater for wall recess or false ceiling. 210006 lick switch. STND LONE system Function The stand alone chrono-thermostatic control head allows control of ambient temperature on the basis of a series of programmed settings, both by time band and by temperature level. It can be installed both on thermostatic and convertible radiator valves. Operation is assured by touch buttons and an integrated temperature sensor. Programmable directly, with display of temperatures and comfort-set back cycles. The unit is battery operated. Quick-coupling installation with adaptor. Product range 210500 Stand alone chrono-thermostatic control head, with backlit display. For thermostatic and convertible radiator valves.

L N Technical specifications Radio wave multi-zone thermal controller code 210100 to manage electronic control heads code 210510 (with power supply unit) Radio communication: RF 868 MHz - EnOcean Standard Transmission range: up to 0 m indoors Display: olour graphic TFT Operativity: touch buttons Thermal control possibilities: up to 8 zones / 2 radiators Weekly programming: uto - Holiday - Eco omfort functions Electric supply: 24 V (dc) uxiliary contact (NO) maximum contact rating for heating demand: 5 Protection class: IP 0 Power consumption: 0,6 W (0,1 W in stand-by) mbient temperature: 0 50 Storage temperature: -20 70 Relative humidity: 10 90% lock data storage without electric supply: 2 hours Power supply Electric supply: 20 V (ac) Output voltage: 24 V (dc) Output current: 180 m Output power: 4,2 W Dimensions: 42,5 x 40 x 22 mm Radio wave electronic control head code 210510 Performance an be coupled to multi-zone thermal controller code 210100 Radio communication: RF 868 MHz - EnOcean Standard Electric supply: 2 / LR6 / 1,5 V alkaline/lithium batteries verage battery life: 2 years Temperature sensor: integrated Operation: touch buttons Radiator valve connection threading: M0 x 1,5 ctuator stroke: up to 4 mm Max. differential pressure with control head installed on valve: 1 bar Protection class: IP 0 olour: white RL 9010 mbient conditions (valve + control head) Medium working temperature range: 5 75 Working temperature: 0 50 Storage temperature: -20 70 Relative humidity: 10 90% non condensing. Radio wave ambient temperature sensor code 210001 for temperature control of the individual zone or room an be connected to multi-zone thermal controller code 210100 Mounting: with double-sided adhesive or flat-head screw mbient temperature: 0 40 Storage temperature: -20 60 Relative humidity: 10 100% Transmission range: up to 0 m indoors Radio communication: RF 868 MHz - EnOcean Standard Electric supply: photovoltaic cell and backup battery attery life: approx 7 years in absence of light Protection class: IP 0 Stand alone chrono-thermostatic control head code 210500 Performance Electric supply: 2 / LR6 / 1,5 V alkaline/lithium batteries verage battery life: 2 years Temperature sensor: integrated Operation: touch buttons, integrated temperature sensor Radiator valve connection threading: M0 x 1,5 ctuator stroke: up to 4 mm Max. differential pressure with control head installed on valve: 1 bar nti-frost function: always active with non user-editable 8 fixed value utomatic window opening detection Protection class: IP 0 olour: white RL 9010 mbient conditions (valve + control head) Medium working temperature range: 5 75 Working temperature: 0 50 Storage temperature: -20 70 Relative humidity: 10 90% non condensing Dimensions N L OUT 210100 142 100 27 210004 40 42,5 22 210500 0 p.1,5 80 55 210510 0 p.1,5 80 55 210010 100 50 25 210006 6 81 16,5 210001 2 80 18

RDIO WVE system Operating principle of the radio wave thermal control system The controller manages the temperature in different rooms by controlling the electronic actuators installed on the valves on each radiator. The temperature sensor inside the electronic control head communicates the temperature reading of the zone to the controller so that it can regulate the opening of the radiator valves of the zone. The temperature measured is an average of all temperature readings of all electronic control heads in the zone. The controller is equipped with its own temperature sensor, which is used in the absence of other sensors or in the event of a fault. The maximum indoor transmission range without significant obstacles (such as thick concrete walls, doors or metallic shields, etc.) is approximately 0 m. In the presence of transmission difficulties, install one or more signal repeaters code 210010 or code 210011. The controller can manage up to 8 zones which are in turn able to control up to a maximum of 4 actuators (hence up to 2 actuators can be managed in total). The electric supply is 24 V (dc). The power supply must be connected in accordance with the diagram in instruction sheet code 2828. void signal transmission problems by positioning the controller in accordance with the instructions given in the installation and commissioning manual. FRONT LED Electronic control heads code 210510 mounted to the valve of each radiator are indispensable to manage heating system zones. Modulating the flow rate of the thermal medium the control heads regulate the ambient temperature in accordance with the selected comfort level. The controller and electronic control head communicate every 10 minutes (20 minutes in summer mode) to maximise battery life. The operation for binding control heads to the controller is easy thanks to the display indications to guide the user through the procedure. The actuator is equipped with touch buttons that are used during the binding procedure and also during normal operation. You can perform several operations such as manual opening or closing of the valve, checking the radio communication level, control head factory reset, etc. The LED on the front of the device lights in accordance with the various operating states of the electronic control head. TOUH UTTONS Electric supply is provided by two 1,5 V batteries with lifetime of up to 2 years depending on use. The ambient temperature sensor code 210001 (optional) can be used if a more accurate ambient temperature reading is required or if the electronic control heads are located in a place in which it is impossible to read the temperature correctly. The optimal position is well clear of doors, windows, radiators and indirect sources of heat, ideally at a height of between 1,2 and 1,5 m. The sensor does not require an external electric supply because it is equipped with a photovoltaic cell with backup battery that ensure continuous operation also in the absence of light for a minimum of approximately 7 years.

LEFFI LEFFI Thermal controller display K UTTON ONFIRMTION UTTON UIN MODO 20.0 20.5 STO 14/09/1 18:14 MENU INFO SROLL UP UTTON SROLL DOWN UTTON The controller is equipped with four buttons and an LD illuminated display providing access to the various menus to consult the status of the system and its regulation. The menu contains all the information associated with the status of the zone selected as main. OMFORT TTIVO FINO LLE 14:00 DEL LRM ZONES LIST ZONE OPERTING MODE SELETION TEMPERTURE SETTING (SET POINT) UIN MODO 20.0 MIN MENU 20.5 STO 14/09/1 18:14 MENU INFO OMFORT TTIVO FINO LLE 14:00 DEL TEMPERTURE RED IN THE ZONE DY - DTE - TIME HET DEMND TIVTED OPTIONS MENU ESS With the MODE function you can change the operating status of the various zones (UTO-EO-HOLIDY- OFF) instantly. You can temporarily change the temperature of each individual zone using the SET POINT function. The INFO menu allows you to view the status of the entire system continuously with the temperature readings and open/closed status of the radiator valves. ny faults are shown in the alarm field. For operating details refer to the installation and commissioning manual. STTUS INFORMTION INFO MENU TO DISPLY SYSTEM STTUS Installation notes for radio wave electronic control heads The electronic control heads must be installed in a horizontal position to allow a correct temperature reading to the internal sensor. If this proves impossible (e.g. a control head installed in a horizontal position would obstruct opening of a door) it becomes mandatory to use the ambient temperature sensor to replace the internal sensor in the control head. In this case the control head can be installed in a vertical position if necessary. It is good practice to install an ambient temperature sensor in each zone if radiators are installed in recesses, in cabinets, behind curtains, under deep shelves, or exposed to direct sunlight thus creating conditions that could affect the accuracy of temperature readings.

Temperature regulation of zones with boiler control in independent systems The controller receives the signal from the temperature sensor to establish the presence of heating demand in the zone in question on the basis of the programming. The valves located in the zone in question are adjusted accordingly. The boiler is started by means of the specific relay output in the presence of a heating demand from at least one of the zones. OPTIONL The temperature sensor is optional in that the electronic control head is already equipped with a built-in temperature sensor. Use of the sensor is recommended in the case of installation in conditions that could impair correct temperature readings. E.g., under deep shelves, as shown in the figure. Room temperature regulation in centralised systems The controller receives the signal from the temperature sensor to establish the presence of heating demand in the zone in question on the basis of the programming. The valves located in the zone in question are adjusted accordingly. OPTIONL The temperature sensor is optional in that the electronic control head is already equipped with a built-in temperature sensor. Use of the sensor is recommended in the case of installation in conditions that could impair correct temperature readings. E.g., under deep shelves, as shown in the figure.

LEFFI LEFFI STND LONE system Operating principle of the thermal regulation system with stand alone chrono-thermostatic control head Stand alone chrono-thermostatic control heads code 210500, installed on the valve of each radiator, regulate the room temperature depending on the selected comfort level and the set time bands. This function guarantees a significant increase in the benefits available with conventional thermostatic valves because it means heat can be used only where and when it is needed. For this purpose, simply set the required temperatures in the different time bands for the whole week in each room. With conventional thermostatic valves the only option is to maintain constant temperatures in each room. However, with programmable electronic thermostatic valves the room temperatures can be varied on the basis of the time and day of the week. Display of the stand alone chrono-thermostatic control head 24 24 21 21 1 2 4 5 6 7 1 2 4 5 6 7 18 6 18 6 UP 15 12 9 15 12 9 MNUL UTOMTI K 21 24 21 24 1 2 4 5 6 7 1 2 4 5 6 7 18 6 18 6 OK DOWN 15 12 9 15 12 9 HOLIDY Operating mode selection The control has four operating modes: MNUL ( ), UTOMTI ( ), HOLIDY ( ), OFF. You can change the operating mode at any time. MNUL mode ( ) UTOMTI mode ( ) HOLIDY mode ( ) OFF mode (Off) The control head modulates in such a way as to maintain the ambient temperature constantly at the set value. The control head modulates in such a way as to control the temperature in accordance with the hourly programming and the two corresponding temperature levels (comfort / set back). The ( ) icon appears on the display together with the comfort icon ( ) or set back icon ( ). The set value is shown in the centre of the display: the programmed time bands are shown on the dial. The comfort ( ) and set back ( ) temperature values can be adjusted using the SetS function in the configuration menu. The factory settings are: - comfort temperature: 20 - set back temperature: 17 different hourly program can be selected or freely modified using the PrOG function in the configuration menu. The temperature is kept constant at the set value until a specified date. fter this date the system returns to the previous mode. The icon is shown on the display. The set value is shown in the centre of the display. The control head assumes the valve fully closed position. The OFF icon is shown on the display. The anti-frost function remains active. OFF Installation notes for stand alone chrono-thermostatic control heads We recommend installing the chrono-thermostatic control heads in a horizontal position. Vertical positioning impairs correct temperature reading with consequent loss of accuracy in ambient temperature regulation. Use of the control head in a position where it is directly exposed to sunlight for prolonged periods or inside radiator cabinets is strongly discouraged. In this latter case the temperature read by the sensor would be very close to the radiator temperature. orrection with temperature offset The stand alone control head is equipped with a temperature reading and management system that allows optimal temperature regulation in accordance with the various parameters. However, in certain cases, such as the use of a control head located behind thick curtains or shelves that are very exposed or very close to the control head, or if the control head is located very close to the floor or close to the ceiling, it is useful to apply a correction factor also called temperature offset, available in the configuration menu. This parameter is used to compensate for the difference between the actual ambient temperature and the temperature measured by the sensor. The chrono-thermostatic control head reads the temperature in the vicinity of the radiator so the value may be different from temperature readings in other parts of the room.

TLE SHOWING OMINTIONS WITH RDITOR VLVES Electronic and chrono-thermostatic control heads can be combined with the following valve series: 8 9 401 402 425 426 421 422 220 221 222 22 224 225 226 227 4001 400 4004 455 F49671 vailable on request specific adapter for thermostatic and convertible radiator valves not manufactured by LEFFI. ccessories Wireless 1st and 2nd level signal repeater with plug for power output code 210011 Electric supply: 20 V (ac). EE 7/4 M/F Schuko plug. Transmission range: up to 0 m indoors. Stand-by power consumption: 0,9 W. 1st and 2nd level wireless signal repeater with antenna code 210010 Recessed or false ceiling version. Electric supply: 20 V (ac). Transmission range: up to 0 m indoors. Stand-by power consumption: 0,6 W. Dimensions: 100 x 50 x 25 mm. lick switch - attery-free wireless interrupter remote control code 210006 The three buttons allow the system to be set to utomatic/eco/off mode without having to adjust the controller directly. Electric supply: without batteries. Radio wave ambient temperature sensor code 210001 For controlling the temperature in each zone or room. Installation: with double-sided adhesive tape or flat-head screw. Transmission range: 0 m indoors. an be connected to the 210 series multi-zone thermal controller. Electric supply: photovoltaic cell and backup battery. attery life: approx. 7 years. Protection class: IP 0. Radio signals checking and validation tester code 210007 mbient temperature: 0 45. Storage temperature: -15 65. Relative humidity: IP 54. Power supply: 2 /LR06 batteries. Mass: 85 g. Dimensions: 110 x 70 x 25 mm. Tamper-proof kit for control head code 210005

SPEIFITION SUMMRY 210100 Radio wave multi-zone thermal controller for managing electronic control heads code 210510. Radio communication RF 868 MHz - EnOcean Standard. Transmission range up to 0 m indoors. olour TFT graphic display. Touch button operation. Possibility to control heat settings for up to 8 different zones/ 2 radiators. Weekly programmable clock. uto - Holiday - Eco - omfort Functions. Maximum contact rating of auxiliary contact (NO) for heating demand 5. lock data retention without electric supply: 2 hours. Protection class IP 0. Power consumption 0,6 W (0,1 W in stand by). Electric supply 24 V (dc) by means of power supply (included), electric supply 20 V (ac), output voltage 24 V (dc), output current 180 m, output power 4,2 W, dimensions 42,5 x 40 x 22 mm. mbient temperature 0 50. Storage temperature -20 70. Relative humidity 10 90%. 210510 Radio wave electronic control head for thermostatic or convertible radiator valves. an be connected to multi-zone thermal controller code 210100. Radio communication RF 868 MHz - EnOcean Standard. White RL 9010. Touch button operation, integrated temperature sensor. Electric supply by two /LR6/1,5 V alkaline/lithium batteries; average battery life 2 years. Radiator valve connection with M0 x 1,5 threading, actuator stroke up to 4 mm. Protection class IP 0, ambient conditions (valve + control head), thermal medium working temperature range 5 75, working temperature 0 50, storage temperature -20 70. Relative humidity 10 90%, non condensing. 210500 Stand alone chrono-thermostatic control head with backlit display. White RL 9010. Touch button operation, integrated temperature sensor. Electric supply by two /LR6/1,5 V alkaline/lithium batteries; average battery life 2 years. Radiator valve connection with M0 x 1,5 threading, actuator stroke up to 4 mm, constantly enabled anti-freeze function with non user-editable 8 fixed value, anti-seizing function, automatic window opening detection. Protection class IP 0, ambient conditions (valve + control head), thermal medium working temperature range 5 75, working temperature 0 50, storage temperature -20 70. Relative humidity 10 90%, non condensing. 210001 Radio wave ambient temperature sensor to control the temperature of each zone or room. an be connected to multi-zone thermal controller code 210100. Transmission range up to 0 m indoors. Radio communication RF 868 MHz - EnOcean Standard. Installation with double-sided adhesive or flat-head screw. mbient temperature 0 40. Storage temperature -20 60. Relative humidity 10 100%. Electric supply by photovoltaic cell and backup battery, approximately 7 years battery life. Protection class IP 0. 210004 Power supply unit for thermal controller code 210100. Electric supply 20 V (ac). Output voltage 24 V (dc). Output current 180 m. Output power 4,2 W. Dimensions 42,5 x 40 x 22 mm. 210011 Wireless 1st and 2nd level signal repeater with plug for power outlet. Electric supply: 20 V (ac). Radio communication RF 868 MHz - EnOcean Standard. Transmission range up to 0 m indoors. Stand-by power consumption 0,9 W. 210010 Wireless 1st and 2nd level signal repeater with antenna. Recessed or flase ceiling version. Electric supply 20V (ac). Radio communication RF 868 MHz - EnOcean Standard. Transmission range up to 0 m indoors. Power consumption in stand-by 0,6 W. Dimensions 100 x 50 x 25 mm. 210006 lick switch - attery-free wireless interrupter remote control. Operation in utomatic/eco/off mode. Radio communication RF 868 MHz - EnOcean Standard. 210007 Radio signals checking and validation tester. Radio communication RF 868 MHz - EnOcean Standard. Electric supply by two /LR6/1,5 V batteries. Protection class IP 54. Mass 85 g. Dimensions 110 x 70 x 25 mm. We reserve the right to make changes and improvements to the products and related data in this publication, at any time and without prior notice. aleffi S.p.. S.R. 229 n. 25 28010 Fontaneto d gogna (NO) Italy Tel. +9 022 8491 Fax +9 022 8672 info@caleffi.com www.caleffi.com opyright 2015 aleffi