LEAD Fiber Optics PRODUCT CATALOGUE

Similar documents
LEAD Fiber Optics PRODUCT CATALOGUE

LEAD Fiber Optics PRODUCT CATALOGUE

LEAD Fiber Optics PRODUCT CATALOGUE

50/100 GHz, 100/200 GHz Passive Interleavers. IBC Series

M-FP ISOLATOR PIGTAILS

GT Channel Ultra Compact CWDM Mux & DeMux

WaveSmart Wave Division Multiplexing (WDM)

Data Center & Cloud Computing DATASHEET. 100 GHz DWDM Passive Optical Add/Drop Multiplexers Data Center & Cloud Computing Infrastruture Solutions

WaveReady 40- and 44-Channel Multiplexer/ Demultiplexer with Test Channel. MDX-40MD101CB and MDX-44MD101CB

Polarization Beam Combiner / Splitter

Odd. Even. Insertion Loss (db)

Table of Contents INTERCONNECTS / CABLE ASSEMBLIES / PATCH PANELS

OPCOM100-DMU40 40-Channel DWDM. Mux/Demux. Typical Application. Figure.1 Point to Point Topology. Datasheet. Raisecom Technology Co., Ltd.

Prisma DWDM Passives. Features. Optical Passive Components

XM40-QD20LD-J 40-ch Multiplexer/Demultiplexer

Wave Division Multiplexing. Passive Mux/Demux Modules & Cables. Datasheet. Features. Overview. Typical 2-Channel Passive Mux/Demux Application

DWDM Mux/Demux product range

Couplers, WDMs Fiber optic couplers

DWDM Dual Fiber series

Optical Passives (ISP)

The COH24-X and COH28-X also feature a phase tunability option in order to perfectly adjust the 90 of the hybrid depending on the wavelength used.

Prisma and Laser Link DWDM Passives for LGX-Compatible Systems

On the subsequent pages, you will find the full, parameter-for-parameter comparison. If you have any questions, please contact Fiberdyne Labs.

MEMS Variable Optical Attenuator (VOA)

WaveReady 8-Channel DWDM OSP Optical Add/Drop Multiplexer for Splice Enclosures. MDF-08MD1N0xB and MDF-08MD1Z0xB

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 16 Channels C27-C42 Dual Fiber DWDM Mux Demux 1U Rack Mount, LC/UPC

MEMS Tunable Filter Products

FMU-MC09-A/B, Pair Packaged DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

WaveReady Single-Channel DWDM Add/Drop for OSP Splice Enclosure. MDF-01AD10xx0

WaveReady CWDM Add/Drop for OSP Splice Enclosure

OPC1600 MUX WDM OADM SPLITTER

Overview. Highlights. General Specification. Datasheet

CWDM Cisco CWDM wavelengths (nm)

DATASHEET FMU-MD08E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Betz & Limbach Projektkabel GmbH, Ringstraße 43, Bretzfeld, Tel / , Fax -58

CISCO ONS /100-GHZ INTERLEAVER/DE-INTERLEAVER FOR THE CISCO ONS MULTISERVICE TRANSPORT PLATFORM

WDM -Transmission V-1.

CWDM Single Fiber series

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

OPCOM100-DAD4D 4-Channel Bidirectional DWDM ADM. Typical Application. Figure.1 Chain Topology. Datasheet. Raisecom Technology Co., Ltd.

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

XSD Single Fiber series DWDM passive optical components

Cisco Prisma Optical Passive Components

Optical Passives and Accessories

WL Photonics Inc. Leading Provider of Fiber Optic Wavelength Tuning and Conditioning Solutions

WaveReady Multi-Degree Reconfigurable Optical Add/Drop Multiplexer WRS-05AD1C00B

Tel:

WL Photonics Inc. Leading Provider of Fiber Optic Wavelength Tuning and Conditioning Solutions

4,8,9 and 10-Channel Tap Photo Detector Array

About KOC Group. Please visit us website for more informations :

User Manual. Portable C-band 26dB-gain EDFA Instrument in compact benchtop. (EDFA-C-26G-S, version 1.0b. January 28, 2015) Fiberprime, Inc.

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 8 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

DATASHEET FMU-MC04E-A/B, w/expansion Port. Data Center & Cloud Computing Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 4 Channels nm Dual Fiber CWDM Mux Demux FMU Plug-in Module, LC/UPC

1751A 1550 nm DWDM DFB Laser Module

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions

Standard/Compact Tap Photo Detector

Data Center & Cloud Computing DATASHEET. Dual & Single Fiber DWDM OADM. Data Center & Cloud Computing. Infrastruture Solutions

1751A 1550 nm DWDM DFB Laser Module

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

FUSED COUPLER C OR L BAND

1

16 Channels C21-C36 Dual Fiber DWDM Mux Demux, w/expansion Port 1U Rack Mount, LC/UPC

OptiSheath Advantage Sealed Terminal Solution for WDM Applications, UCA4-XX An Evolant Solutions Product

DATASHEET FMU-MC04E-A/B, Pair Packaged, w/expansion Port

Datasheet. FMU-MC04-A/B, Pair Packaged 4 Channels Single Fiber CWDM Mux Demux, Plug-in Module, LC/UPC. Overview. Highlights

Headend Optics Platform (CH3000)

WL Photonics Inc. Leading Provider of Fiber Optic Wavelength Tuning and Conditioning Solutions

1751A 1550 nm DWDM DFB Laser Module

Xeston Technologies. XESTON 1550nm DWDM CW DFB Laser With PM Fiber. XQF935 Series Specification Datasheet (Preliminary)

TURNKEY, ULTRA STABLE, OEM LASER DIODE SOURCE OZ-1000 & OZ-2000 SERIES

/ On the web: / Telephone: IS-FIBER (800)

Attenuators are available as - in-line types - plug types

PV Series 850 nm VCSELs

DEP 001. Operation Manual

Fixed Attenuators. Features and Benefits. Standards

ModBox Pulse C-Band 30 ps

Model 6944 and 6940 Node bdr Digital Reverse 4:1 Multiplexing System designed for Prisma II Platform

OMxxDyy-100zz-ab:cd-(M5)-XXYY

100GHz WAVELENGTH DIVISION MULTIPLEXER/ DEMULTIPLEXER (APMUX1100 / APDMX1100)

FX180 OCA. Platform Highlights. Key Features

Dense Wavelength Division Multiplexer (DWDM) 200 GHz Spacing, Multi-Channel, 2ch, 4ch, 8ch, 16ch, 20ch in PEACOC Flexible Tray

Supercontinuum Sources

Chapter 10 WDM concepts and components

Pass Cisco Exam

Passive WDM Networking

NOW WITH BROADER TUNING RANGE

Variable Optical Delay Line

DIGITAL VARIABLE ATTENUATOR

Datasheet. 40ch DWDM Mux Demux + Monitor Port 1U Rack Mount, LC/UPC. Overview. Highlights

Delay Line Interferometers

GS7000 and GainMaker Reverse Segmentable Node bdr Digital Reverse 2:1 Multiplexing System

Product Bulletin. 2 mw WDM Laser for Direct Modulation in Links up to 100 km CQF915/108 Series

1754C C-Band DWDM DFB Laser Module

MADE FOR THE TRADE! XL fibertools Series

Transcription:

LEAD Fiber Optics PRODUCT CATALOGUE DWDM Module TEL:+886-2-8672-2371 FAX:+886-2-8672-3275 Web:http://www.twfiberoptic.com

DWDM Module The DWDM Modules combine or split particular wavelengths into a single fiber and are idea for telecommunication and networking. DWDM technology use ITU standard 0.8nm/1.6nm spacing between the wavelengths, from 1529.55nm to 1560.61nm. DWDM Module utilize thin-film coating and micro optics package technology, They are available in two main configurations: DWDM Multiplexer/Demultiplexer (Mux/Demux) modules and DWDM Add/Drop Multiplexer (OADM) modules. DWDM Mux/Demux Modules are available in 4, 6, 8 and 16 channel configurations. These modules passively multiplex the optical signal outputs from 4 or more electronic devices, send them over a single optical fiber and then de-multiplex the signals into separate, distinct signals for input into electronic devices at the other end of the fiber optic link. DWDM Add/Drop multiplexer modules provide the ability to add or drop a single wavelength or multi-wavelengths from a fully multiplexed optical signal. These module allow intermediate locations between remote sites to access the common, point-to-point fiber segment linking them. Wavelengths not dropped, pass-through the OADM and continue on in the direction of the remote site. Additional selected wavelengths can be added or dropped by successive OADMS as needed. DWDM Add/Drop Multiplexer unit allows a single channel (DWDM Wavelength) to be inserted/extracted from the composite DWDM trunk. There are two versions of the OADM, one does Add/Drop in both directions, the second does Add/Drop in a single direction. We provide both 100 GHZ DWDM Module and 200 GHX DWDM Module with various kinds of Fiber Connectors and Fiber Cable length and optional stainless tube package or standard box package and to meet your requirement. We offer 1x2, 1x4, 1x8 DWDM Module...up to 1x16 DWDM Module. Our DWDM modules are configured by number of channels for any customer-specify channel plan, and can be integrated with taps and detectors for a complete DWDM solution.

LFO DWDM Module Series 100 GHz DWDM Module (100 GHZ Mux/Demux DWDM Module) The DWDM modules with 100GHz channel spacing can be used to combine or separate wavelength channels at standard ITU grid. The minimum channel spacing between neighbor channels is 100GHz. Our 100 GHz DWDM module features narrow channel bandwidth (0.2nm) in ITU channel allocation. Their isolation is greater than 30dB for adjacent channels, and greater than 40dB for non-adjacent channels. They have also high thermal stability. 200 GHz DWDM module (200 GHZ Mux/Demux DWDM Module) The DWDM modules with 200GHz channel spacing can be used to combine or separate wavelength channels at standard ITU grid. The minimum channel spacing between neighbor channels is 200GHz. Our 200 GHz DWDM module features Narrow channel bandwidth (0.5nm) in ITU channel allocation. Their isolation is greater than 30dB for adjacent channels, and greater than 40dB for non-adjacent channels. They have also high thermal stability. 100 GHz DWDM Add/Drop Module The 100 GHz DWDM Add/Drop Unit is designed to add and drop an individual channel flexibly at an optical node of a 100 GHz DWDM network system. Our 100 GHz DWDM Add/Drop Module Features narrow channel bandwidth (0.2nm) in ITU channel allocation. They have low insertion Loss (IL), low IL Uniformity and high Isolation. The central wavelength of each channel can be specified to one of the ITU-T grid wavelengths. 200 GHz DWDM Add/Drop Module The 200 GHz DWDM Add/Drop Unit is designed to add and drop an individual channel flexibly at an optical node of a 200 GHz DWDM network system. Our 200 GHz DWDM Add/Drop Module Features narrow channel bandwidth (0.5nm) in ITU channel allocation. They have low insertion Loss (IL), low IL Uniformity and high Isolation. The central wavelength of each channel can be specified to one of the ITU-T grid wavelengths. 100 GHz DWDM Add/Drop Unit The DWDM Add/Drop Unit with 200GHz is designed to add or drop one single DWDM wavelength at any node location of the network. The central wavelength and channel spacing of this component are at ITU grid. This component is the basic building block of multiple-channel DWDM mux/demux modules. Customers can specify the central wavelength of the add/drop channel of this component. 200 GHz DWDM Add/Drop Unit The DWDM Add/Drop Unit with 200GHz is designed to add or drop one single DWDM wavelength at any node location of the network. The central wavelength and channel spacing of this component are at ITU grid. This component is the basic building block of multiple- channel DWDM mux/demux modules. Customers can specify the central wavelength of the add/drop channel of this component.

100 GHZ DWDM Module Features Environmentally stable Easy installation Custom-defined specifications Low return Loss Low Loss, Low cross Talk ITU standard Applications Telecommunication Local area network DWDM & FTTH Specifications ITEM VALUES Type Mux Demux Channel 4/8/16 Central Wavelength, nm Ch 21~60 or ITU Standard (Customer specify) Channel Space, nm 0.8 Channel Space, GHz 100 Pass band@ 0.5dB,nm ITU±0.1nm Insert Loss, db for 4 channel 2.8 Insert Loss, db for 8 channel 4.0 Insert Loss, db for 16 channel 5.0 Adjacent Channel isolation, db N/A 25 Non-adjacent Channel isolation, db N/A 35 Uniformity, db Minimize Pair Loss or 1.5 Directivity, db 40 Optical Input Return Loss, db 45 Polarization Dependent Loss, db 0.15 Polarization Mode Dispersion (PMD), ps 0.1 Thermal Stability Drift, pm / 1 Max. Optical Power, mw 300 Max. Tensile Load, N 5 Storage Temperature, -40 ~ 85 Operating Temperature, 0 ~ 65 Package size,mm 3 M4(1 4, 1 8 standard);m5(1 16 standard, Mux+Demux 1 8 standard), A2,A3

100 GHz DWDM Module Ordering information WD-D1 XX/XX XX XX X X XX XXX(cm) Connector type 11-ST 21-FC/PC 22-FC/APC 31-SC/PC 32-SC/APC 41-LC/PC 51-MU/PC 00-None Pigtail length 050-50cm 100-100cm 150-150cm 200-200cm 000- Modulized X Central wavelength 11- ch 21/22/23/24 12- ch 25/26/27/28 13- ch 29/30/31/32 14- ch 33/34/35/36 15- ch 21/22/23/24/25/26/27/28/29/30/31/32/33/34/35/36 16- ch 43/44/45/46/47/48/49/50/51/52/53/54/55/56/57/58 No.of channels 04-4 channel, ITU Standard 06-6 channel, ITU Standard 08-8 channel, ITU Standard 16-16 channel, ITU Standard Package option(for both ends) C1-Coated fiber(250um) L1-Loose tube cable (900um) Type M-Mux D-Demux U-Mux/Demux X-Others Channel spacing 1-100 GHz 2-200 GHz X- Others LEAD Fiber Optics Co.,Ltd. TEL:886-2-8672-2371 FAX:886-2-8672-3275 www.twfiberoptic.com sales@fiberoptic.com.tw 3F., No.135, Dasyue Rd., Sansia Township, Taipei County 23741, Taiwan (R.O.C.)

200 GHZ DWDM Module Features Environmentally stable Easy installation Custom-defined specifications Low return Loss Low Loss, Low cross Talk ITU standard Applications Telecommunication Local area network DWDM & FTTH Specifications ITEM VALUES Type Mux Demux Channel 4/8/16 Central Wavelength,nm (4 channel) (21)Ch 21/23/25/27 (22)Ch 29/31/33/35 (23)Ch 43/45/47/49 (24)Ch 51/53/55/57 or ITU Standard (Customer specify) Central Wavelength,nm (8 channel) (25)ch 21/23/25/27/29/31/33/35 (26)ch 43/45/47/49/51/53/55/57 Central Wavelength,nm (16 channel) (27)ch 21/23/25/27/29/31/33/35/43/45/47/49/51/53/55/57 Channel Space, nm 1.6 Channel Space, GHz 200 Pass band@ 0.5dB,nm ITU±0.25nm Insert Loss, db for 4 channel 2.8 Insert Loss, db for 8 channel 4.0 Insert Loss, db for 16 channel 5.0 Adjacent Channel isolation, db N/A 30 Non-adjacent Channel isolation, db N/A 40 Uniformity, db Minimize Pair Loss or 1.5 Optical Input Return Loss, db 45 Polarization Dependent Loss, db 0.15 Polarization Mode Dispersion (PMD), ps 0.15 Thermal Stability Drift, pm / Max. Optical Power, mw 300 Max. Tensile Load, N 5 Storage Temperature, -40 ~ 85 Operating Temperature, 0 ~ 65 Package size,mm 3 M4(1 4, 1 8 standard);m5(1 16 standard,mux+demux 1 8 standard), A2,A3 2

200 GHz DWDM Module Ordering information WD-D2 XX/XX XX XX X X XX XXX(cm) Connector #1 #2 11-ST 21-FC/PC 22-FC/APC 31-SC/PC 32-SC/APC 41-LC/PC 51-MU/PC 00-None Pigtail length 050-50cm 100-100cm 150-150cm 200-200cm 000- Modulized X Central wavelength 21- ch 21//23/25/27 22- ch 29/31/33/35 23- ch 43/45/47/49 24- ch 51/53/55/57 25- ch 21/23/25/27/29/31/33/35 26- ch 43/45/47/49/51/53/55/57 27- ch 21/23/25/27/29/31/33/35/43/45/47/49/51/53/55/57 No.of channels 04-4 channel, ITU Standard 06-6 channel, ITU Standard 08-8 channel, ITU Standard 16-16 channel, ITU Standard Package option(for both ends) C1-Coated fiber(250um) L1-Loose tube cable (900um) Type M-Mux D-Demux U-Mux/Demux X-Others Channel spacing 1-100 GHz 2-200 GHz X-Others LEAD Fiber Optics Co.,Ltd. TEL:886-2-8672-2371 FAX:886-2-8672-3275 www.twfiberoptic.com sales@fiberoptic.com.tw 3F., No.135, Dasyue Rd., Sansia Township, Taipei County 23741, Taiwan (R.O.C.)

100 GHz DWDM Add/Drop Module Features Environmentally stable Easy installation Custom-defined specifications Low return Loss Low Loss, Low cross Talk ITU standard Applications Telecommunication Local area network DWDM & FTTH Specifications ITEM VALUES Channel No. 1/2/4/8 or Customer Specify Starting Wavelength, nm Channel Space, nm Pass band@ 0.5dB, nm Channel 21 to 60 or Customer specify 0.8(100GHz) ITU±0.1nm Operation Wavelength, nm 1500-1610 Insertion Loss (Com In N Drop Ch.) Insertion Loss(M Add Ch. Com Out) Insertion Loss(In Out) 0.4 (N-1)+1.5 0.4 (M-1)+1.5 0.4 (N+M) Adjacent Channel isolation, db 25 Non-adjacent Channel isolation, db 35 Thermal Stability, Wavelength Drift, pm / 1 Thermal Stability, Insertion Loss Variation 0.5(over operating temperature) Directivity, db 40 Return Loss, db 45 Uniformity, db 1.5 or Customer Specify Polarization Mode Dispersion (PMD), ps 0.15 Polarization Dependent Loss, db 0.1 Max. Optical Power, mw 300 Max. Tensile Load, N 5 Storage Temperature, -40 ~ 85 Operating Temperature, 0 ~ 65 Package size,mm 3 M4(1/2/4,channel standard);m5(8 channel standard), A2,A3

100 GHz DWDM Add/Drop Module Ordering information WD-DM XX/XX/XX XX XX XX XX XXX(cm) Connector (in/common/out) 11-ST 21-FC/PC 22-FC/APC 31-SC/PC 32-SC/APC 41-LC/PC 51-MU/PC 00-None Pigtail length 050-50cm 100-100cm 150-150cm 200-200cm 000- Modulized X Starting wavelength 21- ITU standard channel 21 30- ITU standard channel 30 22- ITU standard channel 22 31- ITU standard channel 31 23- ITU standard channel 23 32- ITU standard channel 32 24- ITU standard channel 24 33- ITU standard channel 33 25- ITU standard channel 25 34- ITU standard channel 34 26- ITU standard channel 26 27- ITU standard channel 27 28- ITU standard channel 28 29- ITU standard channel 29 Sets of wavelengths 01-1 set of wavelengths 02-2 set of wavelengths 04-4 set of wavelengths Channel spacing 1S- 0.8 nm, single directional (100 GHz) 1D- 0.8 nm, dual directional (100 GHz) 2S- 1.6 nm, single directional (200 GHz) 2D- 1.6 nm, dual directional (200 GHz) Cable type (for both ends) S1-Singlemode bare fiber L1-Loose tube cable (900um) LEAD Fiber Optics Co.,Ltd. TEL:886-2-8672-2371 FAX:886-2-8672-3275 www.twfiberoptic.com sales@fiberoptic.com.tw 3F., No.135, Dasyue Rd., Sansia Township, Taipei County 23741, Taiwan (R.O.C.)

200 GHz DWDM Add/Drop Module Features Environmentally stable Easy installation Custom-defined specifications Low return Loss Low Loss, Low cross Talk ITU standard Applications Telecommunication Local area network DWDM & FTTH Specifications ITEM Channel No. Starting Wavelength, nm Channel Space, nm Pass band@ 0.5dB, nm VALUES 1/2/4/8 or Customer Specify Channel 21 to 60 or Customer Specify 1.6(200GHz) ITU±0.25nm Operation Wavelength, nm 1500~1610 Insertion Loss (Com In N Drop Ch.) Insertion Loss(M Add Ch. Com Out) Insertion Loss(In Out) 0.4 (N-1)+1.2 0.4 (M-1)+1.2 0.4 (N+M) Adjacent Channel isolation, db 30 Non-adjacent Channel isolation, db 40 Thermal Stability, Wavelength Drift, pm / 2 Thermal Stability, Insertion Loss Variation 0.5(over operating temperature) Directivity, db 40 Return Loss, db 45 Uniformity, db 1.5 or Customer Specify Polarization Mode Dispersion (PMD), ps 0.15 Polarization Dependent Loss, db 0.1 Max. Optical Power, mw 300 Max. Tensile Load, N 5 Storage Temperature, -40 ~ 85 Operating Temperature, 0 ~ 65 Package size,mm 3 M4(1/2/4,channel standard);m5(8 channel standard), A2,A3

200 GHz DWDM Add/Drop Module Ordering information WD-DM XX/XX/XX XX XX XX XX XXX(cm) Connector (in/common/out) 11-ST 21-FC/PC 22-FC/APC 31-SC/PC 32-SC/APC 41-LC/PC 51-MU/PC 00-None Pigtail length 050-50cm 100-100cm 150-150cm 200-200cm 000- Modulized X Starting wavelength 21- ITU standard channel 21 30- ITU standard channel 30 22- ITU standard channel 22 31- ITU standard channel 31 23- ITU standard channel 23 32- ITU standard channel 32 24- ITU standard channel 24 33- ITU standard channel 33 25- ITU standard channel 25 34- ITU standard channel 34 26- ITU standard channel 26 27- ITU standard channel 27 28- ITU standard channel 28 29- ITU standard channel 29 Sets of wavelengths 01-1 set of wavelengths 02-2 set of wavelengths 04-4 set of wavelengths Channel spacing 1S- 0.8 nm, single directional (100 GHz) 1D- 0.8 nm, dual directional (100 GHz) 2S- 1.6 nm, single directional (200 GHz) 2D- 1.6 nm, dual directional (200 GHz) Cable type (for both ends) S1-Singlemode bare fiber L1-Loose tube cable (900um) LEAD Fiber Optics Co.,Ltd. TEL:886-2-8672-2371 FAX:886-2-8672-3275 www.twfiberoptic.com sales@fiberoptic.com.tw 3F., No.135, Dasyue Rd., Sansia Township, Taipei County 23741, Taiwan (R.O.C.)

100 GHz DWDM Add/Drop Unit Features Environmentally stable Easy installation Custom-defined specifications Low return Loss Low Loss, Low cross Talk ITU standard Applications Telecommunication Local area network DWDM & FTTH Specifications ITEM VALUES Pass band@ 0.5dB,nm ITU±0.1nm Channel Space, GHz 100 Add/Drop Channel Insertion Loss(C-P 1 ), db 1.2 Express Channel Insertion Loss(C-P 2 ), db 0.5 Add/Drop Channel Ripple, db 0.3 Isolation(C-P 1 ), db 25 Isolation(C-P 2 ), db 10 Directivity, db 40 Optical Input Return Loss, db 45 Polarization Dependent Loss, db 0.1 Polarization Mode Dispersion (PMD), ps 0.1 Thermal Stability, db / 0.005 Thermal Stability Drift, pm / 1 Max. Optical Power, mw 300 Max. Tensile Load, N 5 Storage Temperature, -40 ~ 85 Operating Temperature, 0 ~ 65 Package size,mm ψ5.5 34mm for coated fiber(250μm) ψ5.5 39mm for Loose tube cable(900μm)

100 GHz DWDM Add/Drop Unit Ordering information WD-A1 XX/XX XX XX X XXX(cm) Connector(common/output P1+P2) 11-ST 21-FC/PC 22-FC/APC 31-SC/PC 32-SC/APC 41-LC/PC 51-MU/PC 00-None Pigtail length 050-50cm 100-100cm 150-150cm 200-200cm 000- Modulized X Center wavelength 21- ITU Standard channel C21 (1560.61 nm) 35- ITU Standard channel C35 (1549.32 nm) Channel spacing 1-100 GHz 2-200 GHz X-Others Package option(for both ends) C1-Coated fiber(250um) C2-Coated fiber(250um) w / boot L1-Loose tube cable (900um) L2-Loose tube cable (900um) w / boot LEAD Fiber Optics Co.,Ltd. TEL:886-2-8672-2371 FAX:886-2-8672-3275 www.twfiberoptic.com sales@fiberoptic.com.tw 3F., No.135, Dasyue Rd., Sansia Township, Taipei County 23741, Taiwan (R.O.C.)

200 GHz DWDM Add/Drop Unit Features Environmentally stable Easy installation Custom-defined specifications Low return Loss Low Loss, Low cross Talk ITU standard Applications Telecommunication Local area network DWDM & FTTH Specifications ITEM VALUES Pass band@ 0.5dB, nm ITU±0.25nm Channel Space, GHz 200 Add/Drop Channel Insertion Loss(C-P 1 ), db 1.2 Express Channel Insertion Loss(C-P 2 ), db 0.4 Add/Drop Channel Ripple, db 0.3 Isolation(C-P 1 ), db 30 Isolation(C-P 2 ), db 10 Directivity, db 40 Optical Input Return Loss, db 45 Polarization Dependent Loss, db 0.1 Polarization Mode Dispersion (PMD), ps 0.15 Thermal Stability, db / 0.005 Thermal Stability Drift, pm / 2 Max. Optical Power, mw 300 Max. Tensile Load, N 5 Storage Temperature, -40 ~ 85 Operating Temperature, 0 ~ 65 Package size, mm ψ5.5 34mm for coated fiber(250μm) ψ5.5 39mm for Loose tube cable(900μm)

200 GHz DWDM Add/Drop Unit Ordering information WD-A2 XX/XX XX XX X XXX(cm) Connector(common/output P1+P2) 11-ST 21-FC/PC 22-FC/APC 31-SC/PC 32-SC/APC 41-LC/PC 51-MU/PC 00-None Pigtail length 050-50cm 100-100cm 150-150cm 200-200cm 000- Modulized X Center wavelength 21- ITU Standard channel C21 (1560.61 nm) 35- ITU Standard channel C35 (1549.32 nm) Channel spacing 1-100 GHz 2-200 GHz X-Others Package option(for both ends) C1-Coated fiber(250um) C2-Coated fiber(250um) w / boot L1-Loose tube cable (900um) L2-Loose tube cable (900um) w / boot LEAD Fiber Optics Co.,Ltd. TEL:886-2-8672-2371 FAX:886-2-8672-3275 www.twfiberoptic.com sales@fiberoptic.com.tw 3F., No.135, Dasyue Rd., Sansia Township, Taipei County 23741, Taiwan (R.O.C.)