ABB MEASUREMENT & ANALYTICS DATA SHEET. TB82 2-wire conductivity transmitters

Similar documents
FICHA TÉCNICA DE PRODUTO

Features and Applications

C1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications

Head mounted Temperature Transmitter TF02/TF02-Ex

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

2-Wire Toroidal Conductivity Transmitters Series APT2000 Specifications

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

MEAS CAL ALARM CONF APT2000 TC

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

General Specifications

Model 264IB. ABB 2600T Series Engineered solutions for all applications

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

TB404 Conductivity sensors. Perfect for use in standard to highly corrosive solutions

Conductivity Analyzer

AT200 External Mount Magnetostrictive Level Transmitter

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

LST400 Ultrasonic level / open channel flow transmitter

Loop Powered Indicator

TWO-WIRE TRANSMITTERS FOR ph, ORP, CONDUCTIVITY, OXYGEN, OZONE, AND CHLORINE

DOC. NO. : C3200-E04A APPROVED. Smart PressureTransmitter for Gauge and Absolute Pressure Measurement MODEL APT3200

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

LST100 Ultrasonic level transmitter for upstream oil and gas

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Level Measurement Continuous level measurement Radar transmitters

TwO-wIRE TRANSmITTERS FOR ph, ORP, CONDUCTIvITy, OxygEN, OzONE, AND CHLORINE

Model 3244MV MultiVariable Temperature Transmitter with Profibus-PA

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Specification DataFile

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Process display RIA 261

Magnetostrictive Level Transmitter

itemp PA TMT184 Technical information

Analyze IT Single and Dual Input Analyzers for ph/redox (ORP)

PAD - Heavy Duty Differential Pressure Trasmitter

APT3200L SMART PRESSURE TRANSMITTER. Application Areas: WITH DIAPHRAGM SEAL

Humidity Sensor/Transmitter Assembly

Field indicator for current loops with HART communication Models DIH50, DIH52

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Smart Pressure Transmitter

Model 870ITPH Intelligent Electrochemical Transmitter for ph, ORP, or Ion Selective Electrode Measurement

ABB MEASUREMENT & ANALYTICS DATA SHEET. AX410, AX411, AX416, AX450 and AX455 Single and dual input analyzers for low level conductivity

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

Digital conductivity transmitter

Model 870ITEC Intelligent Electrochemical Transmitter for Electrodeless Conductivity Measurements

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

Alphaline Temperature Transmitters

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

ABB MEASUREMENT & ANALYTICS DATA SHEET. AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)

SMART TEMPERATURE TRANSMITTERS. smar

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Rail mounted Temperature Transmitter TH102/TH102-Ex

SITRANS T measuring instruments for temperature

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Inductive conductivity measurement mypro CLM 431 / CLD 431 inductive

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

General Specifications

FIELD DEVICES - ANALYTICAL

815PT Smart Pressure Transmitter

Model 3244MV. MultiVariable Temperature Transmitter with Profibus PA. Product Data Sheet

Temperature transmitter itemp PCP DIN rail TMT 121

Positioner with HART Communication Type 3780

Wireless Base Radio. Wireless Transmitters

Model 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet

High-precision process calibrator Model CED7000

Temperature Measurement

itemp HART DIN rail TMT112

0 2 1 â Ó. itemp HART TMT182. Technical Information

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Rosemount 3101, 3102, and 3105

Multi-electrode Conductivity Analyzers

Submersible pressure sensor For water and wastewater Model LW-1

PROGRAMMABLE FIELD TEMPERATURE TRANSMITTER

Wireless Temperature Transmitters Series XYR 5000, Model WT5xx/WT5xxR/WT5xxT Specifications - Americas

Indumax CLS50/CLS50D. Technical Information

Electro-Magnetic Flowmeters COPA-XE

Temperature transmitter with local display RIT 261

General Specifications

The Rosemount 848T Wireless Temperature Transmitter

1066 Liquid Analytical Transmitter

Rosemount 148 Temperature Transmitter

Signet 2751 DryLoc ph/orp Smart Sensor Electronics

TFZ Programmable FOUNDATION Fieldbus Temperature Transmitter

AX460, AX466 and AX416 Single and dual input analyzers for ph/redox (ORP)

Power supply. Calibration. Surface finishing. Seal. Process connection

APT3100 MODEL. Smart Pressure Transmitter. for Differential / Gauge / Absolute Pressure Measurement. Doc. No. : C3100-E05A

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

AT100S Magnetostrictive Level Transmitter. Sanitary magnetostrictive level transmitter K-TEK Products

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Temperature Input Module for Zone 1 Series 9482/32

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

Submersible pressure sensor For oils and fuels Model LF-1

Conductivity Transmitter

0 2 1 â Ó. itemp HART TMT182. Technical Information

FIELD DEVICES - ANALYTICAL

Transcription:

ABB MEASUREMENT & ANALYTICS DATA SHEET TB8 -wire conductivity transmitters

TB 8 -W I R E CON DUCT I VI T Y TR ANSMIT TE RS DS/ TB8 -E N RE V. H Measurement made easy Loop-powered transmitters that reduce installation costs in hazardous areas Intuitive user interface easy-to-use menus guide the operator through set-up, calibration and maintenance Full range of conductivity sensors make measurements in ultra-pure or high conductivity applications Advanced digital communications available with PROFIBUS PA, FOUNDATION Fieldbus or HART communications Hazardous area transmitters withstand the harshest environments NEMA 4X / IP65 housings Large, easy-to-read display shows primary measurement together with user-selectable secondary display (temperature, output current or sensor input) Programmable security codes prevents unauthorized modifications to transmitter configuration and calibration Intrinsically safe, non-incendive design enables use in hazardous areas

TB8 -WIRE CONDUCTIVITY TRANSMITTERS DS/TB8-EN REV. H 3 General description The ABB TB8 -wire conductivity transmitters are available in three base configurations to use ABB s -electrode, 4-electrode or toroidal (electrodeless) sensors, allowing for installations ranging from ultra-pure water to the most difficult chemical applications. The TB8 is available with traditional programmable outputs or with advanced digital communications using FOUNDATION Fieldbus (FF), PROFIBUS PA (PA) or HART. Setup, maintenance and operation in the field is simple. Easyto-follow instructions appear above each smart key. The userfriendly interface provides for straightforward transmitter configuration and calibration. A unique secondary display clearly defines each menu option when programming the transmitters. During normal operation, the secondary display may be configured to show process temperature, current output, concentration type, raw conductivity or software revision depending upon configuration. The TB8 transmitters meet current CE, NEMA 4X, IP65, CSA, FM, ATEX and FISCO requirements. Sensor compatibility and ranges Sensor compatibility is determined by the TB8 model number. The TB8 is available in three base configurations. The TB8TE connects to ABB -electrode sensors, TB8EC to ABB 4-electrode sensors, and TB8TC to ABB toroidal sensors. A menu choice during programming makes changing from one cell constant or sensor group simple; no jumpers or manual adjustments required. Temperature compensation The TB8 is compatible with a variety of automatic temperature compensation elements. See Specification section. Programmable security code The transmitter has a 3-digit security code to prevent unauthorized modifications to any combination of the following menus: Calibration, Output / Hold, Security and Configure. Basic or advanced programming modes Note. FOUNDATION Fieldbus, PROFIBUS PA models and HART are available only in advanced mode. Available with either basic or advanced programming modes at time of purchase, the advanced mode offers an expanded feature set for more complex operations, for example: Nonlinear and concentration analyzer modes Available mode TB8TE TB8EC TB8TC 0 to 5 % NaOH 0 to 0 % NaCl 0 to 8 % HCl 0 to 0 % HSO4 User-defined Advanced temperature compensation modes Available mode TB8TE TB8EC TB8TC 0 to 5 % NaOH 0 to 0 % NaCl 0 to 8 % HCl 0 to 0 % HSO4 User-defined Pure water neutral salt Pure water trace base Pure water trace acid Analog pulse diagnostic output Impresses a user-defined 0.6 to 6 ma pulse on the 4 to 0 ma output to alert the operator of a fault condition (not available on transmitters with digital communication).

4 TB8 -WIRE CONDUCTIVITY TRANSMITTERS DS/TB8-EN REV. H Diagnostics The transmitter constantly monitors both itself and the sensor to ensure reliability and accuracy. Upon detection of a diagnostic condition, the transmitter provides diagnostic notification by flashing FAULT on the display and supplying a pulse on the analog output (if activated on non-hart devices). Transmitters equipped with Foundation Fieldbus or PROFIBUS PA send a complete diagnostic description over the network to the controller. This enables easy, immediate troubleshooting. Pressing FAULT info on the transmitter provides a short description and fault codes on the secondary display. The FAULT icon remains active until the problem has been resolved. Adjustable damping Damping is helpful in process environments where noise is present. It is a capacitive type lag where reaction to any signal change is slowed according to the entered time constant. For example, the response to a step input change reaches approximately 63 % of its final value in 5 seconds for 5 seconds of damping. Communications FOUNDATION Fieldbus (FF) addresses modern instrument users' needs for flexibility and cost savings, while providing a whole host of additional features. Measurement variable quality and diagnostic conditions transmitted during each scheduled data transfer Easily configured remotely or locally Transmission of multiple process variables using two analog input blocks (AI) Transmitter characteristics such as device name, manufacturer and serial number via a standard resource block Configuration and calibration capability via custom enhanced transducer block Provides calibration methods on supported host tools and systems PROFIBUS PA (PA) is a standardized, open, digital communications system for process automation. Configuration, calibration and trending available via a Device Type Manager (DTM) when used on compatible host tools and systems Measurement variable quality and diagnostic conditions transmitted during each scheduled data transfer Remote and local configuration capability Choice of standard analyzer profile or manufacturer specific profile conforms to PROFIBUS PA Profile requirements v. 3.0 GSD files available on all product variations Utilizes one physical, one transducer, and two analog input blocks HART communications protocol provide remote programming via any HART-compatible primary or secondary communications device. Digital communications through a low-level modulation superimposed on the standard 4 to 0 ma current loop Accommodates universal, common practice and devicespecific command sets for functionality within HART networks and for use with HART hand-held terminals Driver files for various host systems and tools available Calibration The TB8 features a simple and straightforward one-point or two-point calibration of the primary process variable and temperature. Calibration data may be manually edited.

TB8 -WIRE CONDUCTIVITY TRANSMITTERS DS/TB8-EN REV. H 5 Specification Type -wire conductivity transmitter: -electrode model TB8TE 4-electrode model TB8EC Toroidal model TB8TC Input sensor types TB8TE: ABB -electrode sensors TB8EC: ABB 4-electrode sensors TB8TC: ABB toroidal sensors Input temperature compensation types Temperature element TB8TE TB8EC TB8TC Pt 00 Pt 000 3 kω RTD 4.75 kω RTD Temperature display range 0 to 300 C ( 4 to 57 F) Advanced temperature compensation modes Mode TB8TE TB8EC TB8TC 0 to 5 % NaOH 0 to 0 % NaCl 0 to 8 % HCl 0 to 0 % HSO4 User-defined Pure water neutral salt Pure water trace base Pure water trace acid Measurement ranges TB8TE -electrode conductivity Cell constant Measurement range Display resolution Auto-range 0.0 0 to 99.9 μs/cm 0.00 μs/cm 0 to.999 μs/cm 0 to 9.99 μs/cm 0 to 99.9 μs/cm 0.0 0 to 999 μs/cm 0.0 μs/cm 0 to 9.99 μs/cm 0 to 99.9 μs/cm 0 to,999 μs/cm.00 0 to 9.99 ms/cm 0. μs/cm 0 to 99.9 μs/cm 0 to,999 μs/cm 0 to 9.99 ms/cm TB8EC 4-electrode conductivity Sensor group Measurement range Display resolution Auto-range A 0 to,999 ms/cm 0. μs/cm 0 to 99.9 μs/cm 0 to,999 μs/cm 0 to 9.99 ms/cm 0 to 99.9 ms/cm 0 to,999 ms/cm B 0 to 999 μs/cm 0.0 μs/cm 0 to 9.9 μs/cm 0 to 99.9 μs/cm 0 to,999 μs/cm TB8TC torodial conductivity Sensor group Measurement range Display resolution Auto-range Torodial 0 to,999 ms/cm 0. μs/cm 0 to 99.9 μs/cm 0 to,999 μs/cm 0 to 9.99 ms/cm 0 to 99.9 ms/cm 0 to,999 ms/cm Accuracy Display ±0.5 % of measurement range per decade (TB8EC and TC) ±.0 % of measurement range per decade (TB8TE) Output ±0.0 ma Temperature C or F Repeatability Display ±0.5 % of measurement range per decade (TB8EC and TC) ±.0 % of measurement range per decade (TB8TE) Output ±0.0 ma Temperature C to F Stability Display ± LSD typical, ±5 LSD max Output ±0.0 ma Temperature C or F Output Isolated 4 to 0 ma, linear and non-linear (non-fieldbus models) Output minimum span Sensor TB8TE TB8EC TB8TC Cell constant 0.0 µs/cm Cell constant 0.0 0 µs/cm Cell constant.00 00 µs/cm Group A 00 µs/cm Group B 0 µs/cm Toroidal 00 µs/cm Concentration: 5 % of maximum configured concentration Output maximim span (full scale settings) Sensor TB8TE TB8EC TB8TC Cell constant 0.0 99.9 µs/cm Cell constant 0.0,999 µs/cm Cell constant.00 9.99 ms/cm Group A,999 ms/cm Group B,999 µs/cm Toroidal,999 ms/cm Concentration: 999 digits Damping Adjustable between 0.0 and 99.9 seconds

6 TB8 -WIRE CONDUCTIVITY TRANSMITTERS DS/TB8-EN REV. H Specification Environmental (temperature) Operating 0 to 60 C ( 4 to 40 F) LCD 0 to 60 C ( 4 to 40 F) Storage 40 to 70 C ( 40 to 58 F) Humidity up to 95 % RH Enclosure NEMA 4X and IP65, anodized aluminum alloy with polyester powder coating Size (/ DIN), H x W x D 44.0 x 44.0 x 7.0 mm (5.67 x 5.67 x 6.73 in) Min. panel depth 44.8 mm (5.70 in) Max. panel thickness 9.5 mm (0.38 in) Panel cutout 35.4 [+.3, -0.8] by 35.4 [+.3, -0.8] mm (5.33 [+0.05, -0.03] by 5.33 [+0.05, -0.03] in) Weight.9 kg (4. lb) 3.4 kg (7.5 lb) with pipe mounting hardware Conduit connections Two each:. mm (0.875 in) holes in enclosure that accept / in hubs Agency certifications ATEX 00A ATEX Category II G; EEX ia, Zone ; Group IIC, T4 when used with appropriate barriers Canadian Standards Association (CSA) Intrinsic safety: Class I, II, III; Division ; applicable Groups A, B, C, D, E, F and G; when used with appropriate barriers. T3C Non-incendive: Class I, Division, Groups A, B, C, and D. Class II, Division, Groups E, F and G. Class III, Division Factory Mutual (FM) Intrinsic safety: Class I, II, III; Division ; applicable Groups A, B, C, D, E, F and G; when used with appropriate barriers. T3C (max. ambient temperature: 60 C [40 F]) Non-incendive: Class I, Division, Groups A, B, C, and D. Class II, Division, Groups F and G. Class III, Division. T5 Fieldbus Intrinsically Safe Concept (FISCO) Fieldbus products (FF and PA) meets the requirements for the FISCO model EMC requirements CE Certified complies with all applicable European Community product requirements, specifically those required to display the CE markings on the product nameplate. Lightning suppressor Installed integral to the transmitter to suppress lightning induced transients. Tested to suppress 0 successive 8 by 0 μsec pulses with a peak value of 0 ka (reference IEEE C6.4) Power requirements Standard 4.0 to 53 V DC (4.0 to 4 V DC for certified applications) HART 4 to 53 V DC (4 to 4 V DC for certified applications). For HART communication, a 50 Ω resistor is required; 9 V DC minimum voltage required. 4 V DC required for liftoff Foundation Fieldbus & PROFIBUS PA bus powered 9 to 3 V DC (non-i.s. model) 9 to 4 V DC (I.S. model) 5 ma quiescent current consumption

TB8 -WIRE CONDUCTIVITY TRANSMITTERS DS/TB8-EN REV. H 7 Dimensions Dimensions in mm (in) Transmitter 43.8 (5.66) 6.7 (.05) 0. (0.40) 43.5 (5.65) 4.0 (4.49) 43.8 (5.66) 50.8 (.00) 4.9 (.65) 4.0 (0.55) (4 typical) 3.8 (.9) (4 typical). (0.88) dia. ( typical) Front Side Bottom Pipe-mount option Pipe-mount bracket 3/8 in lock washer (4) (0.47) 3/8 in flat washer (4) 03 (8.0) Pipe (0.47) 5/6 in U-bolt () 3/8 x 5/8 in bolt (4) 5/6 in flat washer (4) 5/6 in nut (4) 5/6 in lock washer (4) Panel-mount option 9.5 (0.38) max. panel thickness 35.4 +.3 0.8 +0.05 (5.33 ) 0.03 Panel mounting bracket (4) Panel mounting screw (4).9 (0.47) Panel cutout 35.4 +.3 0.8 +0.05 (5.33 ) 0.03 Rear cover removed 3/8 in lockwasher (4).9 (0.47) Minimum panel depth = 44.8 (5.7) Panel gasket Panel External earth (ground) screw Rear view 3/8 x / in hex screw (4)

8 TB8 -WIRE CONDUCTIVITY TRANSMITTERS DS/TB8-EN REV. H Dimensions Dimensions in mm (in) Wall (side) mounting option Pipe-mount bracket 3/8 in flat washer (4) Fasteners for wall (supplied by others) 7 (8.94) Wall Wall 3/8 x 5/8 in bolt (4) 3/8 in lock washer (4) Wall / Hinge (rear) mounting option Fasteners for wall (supplied by others) 3/8 x 3/4 in bolt (8) Stainless steel hinge 3/8 in flat washer (4) Wall pipe-mount bracket 'L' bracket 3/8 in nut (8) 3/8 in flat washer (8) 3/8 in lock washer (8) 3/8 x 5/8 in bolt 3/8 in lock washer (4) Top view Front view

FOR 8EC ONLY FOR 8EC ONLY TB8 -WIRE CONDUCTIVITY TRANSMITTERS DS/TB8-EN REV. H 9 Electrical connections SENSOR CONNECTIONS TB GREEN RED WHITE BLACK BLUE YELLOW HVY GRN DRIVE SENSE SENSE DRIVE RTD RTD SHIELD POWER/OUTPUT CONNECTIONS + SIGNAL AMMETER +3 TERMINALS 4 TB POWER TEST SENSOR CONNECTIONS TB BLACK BLUE WHITE RED GREEN YELLOW HVY GRN 3 4 5 6 7 8 DRIVE DRIVE SENSE SENSE RTD RTD SHIELD POWER/OUTPUT CONNECTIONS + SIGNAL AMMETER +3 TERMINALS 4 TB POWER TEST TB8EC and TB8TE -electrode and 4-electrode TB8TC Toroidal (electrodeless)

0 TB8 -WIRE CONDUCTIVITY TRANSMITTERS DS/TB8-EN REV. H Ordering information -wire conductivity transmitter base model TB8 XX X X X 0 X X X Input type -electrode 4-electrode Toroidal (electrodeless) Programming option Basic Advanced Digital communications option None (analog only) HART FOUNDATION Fieldbus PROFIBUS PA Lightning suppressor Included Housing type Powder-coated aluminum 0 Mounting options None Pipe Wall / Hinge (rear mount) Panel Wall (side mount) Agency approvals None FM (Factory Mutual) CSA (Canadian Standards Association) ATEX 00A Tag None Stainless steel Mylar TE EC TC 0 3 0 3 4 0 3 0 Advanced programming option must be selected for HART, FOUNDATION Fieldbus or PROFIBUS PA digital communication option Accessories Panel-mount kit: Pipe-mount kit: Hinge-mount kit: Wall-mount kit: 4TB955-03 4TB955-04 4TB955-05 4TB955-056 Product instruction manual One copy is supplied with the instrument at no charge Acknowledgements Mylar is a registered trademark of Dupont Teijin Films. HART is a registered trademark of the HART Communication Foundation. PROFIBUS is a registered trademark of PROFIBUS and PROFINET International (PI). FOUNDATION is a registered trademark of the Fieldbus Foundation

TB8 -WIRE CONDUCTIVITY TRANSMITTERS DS/TB8-EN REV. H TB8EC 4-electrode transmitter TB8TC toroidal transmitter TB8TE -electrode transmitter Sales Service

ABB Limited Measurement & Analytics Oldends Lane, Stonehouse Gloucestershire, GL0 3TA UK Tel: +44 (0)453 86 66 Fax: +44 (0)453 89 67 Email: instrumentation@gb.abb.com ABB Inc. Measurement & Analytics 5 E. County Line Road Warminster, PA 8974 USA Tel: + 5 674 6000 Fax: + 5 674 783 abb.com/measurement We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 08 ABB. All rights reserved. 3KXA804R00 DS/TB8-EN Rev. H 04.08