Heterodyne swept-source optical coherence tomography for complete complex conjugate ambiguity removal

Similar documents
Simultaneous acquisition of the real and imaginary components in Fourier domain optical coherence tomography using harmonic detection

Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting

some aspects of Optical Coherence Tomography

Swept Wavelength Testing:

7 CHAPTER 7: REFRACTIVE INDEX MEASUREMENTS WITH COMMON PATH PHASE SENSITIVE FDOCT SETUP

Periodic Error Correction in Heterodyne Interferometry

Dynamic Phase-Shifting Electronic Speckle Pattern Interferometer

High-speed spectral-domain optical coherence tomography at 1.3 µm wavelength

Axsun OCT Swept Laser and System

60 MHz A-line rate ultra-high speed Fourier-domain optical coherence tomography

Talbot bands in the theory and practice of optical coherence tomography

University of Huddersfield Repository

Lab Report 3: Speckle Interferometry LIN PEI-YING, BAIG JOVERIA

Characterization of a fibre optic swept laser source at 1!m for optical coherence tomography imaging systems

Optical coherence tomography

Isolator-Free 840-nm Broadband SLEDs for High-Resolution OCT

S.R.Taplin, A. Gh.Podoleanu, D.J.Webb, D.A.Jackson AB STRACT. Keywords: fibre optic sensors, white light, channeled spectra, ccd, signal processing.

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

Receiver Performance and Comparison of Incoherent (bolometer) and Coherent (receiver) detection

Photonic time-stretching of 102 GHz millimeter waves using 1.55 µm nonlinear optic polymer EO modulators

OPSENS WHITE-LIGHT POLARIZATION INTERFEROMETRY TECHNOLOGY

Pulsed-source spectral-domain optical coherence tomography with reduced motion artifacts

Demonstration of Range & Doppler Compensated Holographic Ladar

Submillimeter (continued)

Simultaneous Measurements for Tunable Laser Source Linewidth with Homodyne Detection

Development of a Low Cost 3x3 Coupler. Mach-Zehnder Interferometric Optical Fibre Vibration. Sensor

High-speed imaging of human retina in vivo with swept-source optical coherence tomography

Single camera spectral domain polarizationsensitive optical coherence tomography using offset B-scan modulation

Citation for published version (APA): Nguyen, D. V. (2013). Integrated-optics-based optical coherence tomography

Recent Developments in Fiber Optic Spectral White-Light Interferometry

OPSENS WHITE-LIGHT POLARIZATION INTERFEROMETRY TECHNOLOGY

SENSOR+TEST Conference SENSOR 2009 Proceedings II

High Sensitivity Interferometric Detection of Partial Discharges for High Power Transformer Applications

CHAPTER 5 FINE-TUNING OF AN ECDL WITH AN INTRACAVITY LIQUID CRYSTAL ELEMENT

Residual Phase Noise Measurement Extracts DUT Noise from External Noise Sources By David Brandon and John Cavey

Off-axis full-field swept-source optical coherence tomography using holographic refocusing

Fringe Parameter Estimation and Fringe Tracking. Mark Colavita 7/8/2003

Lecture 7 Fiber Optical Communication Lecture 7, Slide 1

Comparison of FMCW-LiDAR system with optical- and electricaldomain swept light sources toward self-driving mobility application

Module 5: Experimental Modal Analysis for SHM Lecture 36: Laser doppler vibrometry. The Lecture Contains: Laser Doppler Vibrometry

Performance Analysis Of Hybrid Optical OFDM System With High Order Dispersion Compensation

SIMULTANEOUS INTERROGATION OF MULTIPLE FIBER BRAGG GRATING SENSORS FOR DYNAMIC STRAIN MEASUREMENTS

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Supplementary Materials

University of Lübeck, Medical Laser Center Lübeck GmbH Optical Coherence Tomography

Phase Modulator for Higher Order Dispersion Compensation in Optical OFDM System

Application Note. Photonic Doppler Velocimetry

Polarization Sagnac interferometer with a common-path local oscillator for heterodyne detection

Optical Coherent Receiver Analysis

High-speed optical frequency-domain imaging

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Optical Coherence Tomography Systems and signal processing in SD-OCT

The secondary MZM used to modulate the quadrature phase carrier produces a phase shifted version:

Modified Spectrum Auto-Interferometric Correlation. (MOSAIC) for Single Shot Pulse Characterization

Basics of INTERFEROMETRY

Stabilizing an Interferometric Delay with PI Control

Theory and Applications of Frequency Domain Laser Ultrasonics

R. J. Jones College of Optical Sciences OPTI 511L Fall 2017

History of Velocimetry Technology

la. Smith and C.P. Burger Department of Mechanical Engineering Texas A&M University College Station Tx

visibility values: 1) V1=0.5 2) V2=0.9 3) V3=0.99 b) In the three cases considered, what are the values of FSR (Free Spectral Range) and

Parallel Digital Holography Three-Dimensional Image Measurement Technique for Moving Cells

200-GHz 8-µs LFM Optical Waveform Generation for High- Resolution Coherent Imaging

SENSITIVITY OF AN EMBEDDED FIBER OPTIC ULTRASOUND SENSOR

레이저의주파수안정화방법및그응용 박상언 ( 한국표준과학연구원, 길이시간센터 )

A novel tunable diode laser using volume holographic gratings

Supplementary Figures

Customized Lasers for Specific Swept Source OCT Applications. Bill Ahern Axsun Technologies, Inc. June 20, 2013

Spectral domain optical coherence tomography with balanced detection using single line-scan camera and optical delay line

Development of innovative fringe locking strategies for vibration-resistant white light vertical scanning interferometry (VSI)

Swept Source Optical Coherence Tomography for Small Animals: System Control and Data Acquisition

Simple interferometric fringe stabilization by CCD-based feedback control

Stabilized Interrogation and Multiplexing. Techniques for Fiber Bragg Grating Vibration Sensors

High-Coherence Wavelength Swept Light Source

High stability multiplexed fibre interferometer and its application on absolute displacement measurement and on-line surface metrology

Figure1. To construct a light pulse, the electric component of the plane wave should be multiplied with a bell shaped function.

Optical generation of frequency stable mm-wave radiation using diode laser pumped Nd:YAG lasers

R. J. Jones Optical Sciences OPTI 511L Fall 2017

Pulsed-source and swept-source spectral-domain optical coherence tomography with reduced motion artifacts

Chapter 1. Overview. 1.1 Introduction

Real-time optical spectrum analysis of a light source using a polarimeter

Phase-resolved optical frequency domain imaging

Chapter 3 Experimental study and optimization of OPLLs

ULTRASONIC TRANSDUCER PEAK-TO-PEAK OPTICAL MEASUREMENT

Full Field Swept Source Optical Coherence Tomography

Lecture 25 Optical Coherence Tomography

White-light interferometry, Hilbert transform, and noise

Receiver Signal to Noise Ratios for IPDA Lidars Using Sine-wave and Pulsed Laser Modulation and Direct Detections

PHASE DETECTION WITH SUB-NANOMETER SEN- SITIVITY USING POLARIZATION QUADRATURE EN- CODING METHOD IN OPTICAL COHERENCE TOMOG- RAPHY

A laser speckle reduction system

High-performance, multi-channel, fiber-based absolute distance measuring interferometer system

Choosing an Oscilloscope for Coherent Optical Modulation Analysis

Performance Limitations of WDM Optical Transmission System Due to Cross-Phase Modulation in Presence of Chromatic Dispersion

Absolute distance interferometer in LaserTracer geometry

Stability of a Fiber-Fed Heterodyne Interferometer

Coherent Receivers Principles Downconversion

Fiber Pigtailed Variable Frequency Shifters Acousto-optic products

Fourier Domain (Spectral) OCT OCT: HISTORY. Could OCT be a Game Maker OCT in Optometric Practice: A THE TECHNOLOGY BEHIND OCT

Department of Mechanical Engineering and Automation, Harbin Institute of Technology Shenzhen Graduate School, Shenzhen, , China

Linewidth Measurements of Brillouin Fiber Lasers

Transcription:

Heterodyne swept-source optical coherence tomography for complete complex conjugate ambiguity removal Anjul Maheshwari, Michael A. Choma, Joseph A. Izatt Department of Biomedical Engineering, Duke University, Durham, NC USA 2778 ABSTRACT Fourier domain techniques have increasingly gained attention in the optical coherence tomography field. This is mainly due to demonstrated sensitivities of two to three orders of magnitude greater than conventional time domain techniques. FDOCT images are plagued with two sources of ambiguity and artifact. First, complex conjugate ambiguity arises from the Fourier transform of the real-valued interferometric signal. This ambiguity causes a superposition of reflectors at positive and negative pathlength differences between the sample and reference reflectors. Secondly, the source spectral shape and sample autocorrelation terms appear at DC, there by obscuring reflectors at zero pathlength difference. In this paper, we show that heterodyne detection in swept-source OCT (SSOCT) allows for the resolution of complex conjugate ambiguity and the remo val of spectral and autocorrelation artifacts. We show that frequency shifting of the reference arm optical field, by use of acousto-optic modulators, upshifts the cross-interferometric signal to a user-tunable electronic frequency that corresponds to a adjustable electronic pathlength mismatch between the interferometer arms. This electronic pathlength mismatching recenters the A-scan at an offset that can be far from DC, which effectively resolves the complex conjugate ambiguity problem. Additionally, spectral and autocorrelation terms still reside near DC, which allows them to be removed by high-pass filtering. We also show that complex conjugate ambiguity resolution via frequency shifting is immune to falloff induced by finite source linewidth in SSOCT. Keywords: optical coherence tomography, Fourier-domain, heterodyne, complex conjugate ambiguity removal. INTRODUCTION Fourier domain optical coherence tomography (FDOCT) techniques have reshaped the OCT landscape due to demonstrated sensitivities that are two to three orders of magnitude greater than their time domain counterparts. This sensitivity advantage has been confirmed both theoretically and experimentally. -3 The primary features of FDOCT systems are that they feature line rates in the tens of kilohertz regime with sensitivities comparable to previous state-ofthe-art time domain systems. The shift to FDOCT, however, is not without costs. FDOCT images contain two important sources of ambiguity and artifact. First, since the Fourier transform of a real-valued fourier domain interferometric signal is Hermetian symmetric, sample reflectors at a positive displacement, + x, with respect to the reference reflector, are superimposed on those at a negative displacement, - x. Second, the source spectral shape and sample autocorrelation terms transform to x =, thereby obscuring reflectors positioned at zero pathlength difference. These artifacts can be removed by retrieval of the complex interferometric signal. Previous techniques for collecting the complex Fourier domain interferometric signal have relied on collecting the inphase and π/2-shifted (quadrature) components generated by phase stepping interferometry 4 or by 3x3 interferometry. 5,6 These techniques are constrained to homodyne insofar as both the reference and sample arm optical fields have the same phase velocity. Homodyne detection is required for spectral-domain OCT (SDOCT) systems that employ spectrometers coupled to charge accumulation detectors such as charge-coupled devices (CCDs) and photodiode arrays. In sweptsource OCT, however, a current-generating photodiode is employed, which allows the spectral interferometric signal to be encoded with a characteristic heterodyne beat frequency. In this paper we show that heterodyne detection in swept-source OCT (SSOCT) allows for the resolution of complex conjugate ambiguity and the removal of spectral and autocorrelation artifact. We show that frequency shifting the reference arm optical field upshifts the cross-interferometric signal to a user-tunable frequency that corresponds to an electronic pathlength mismatch between the interferometer arms. This electronic pathlength mismatching recenters the A-scan at an offset that can be far from DC, which effectively resolves the complex conjugate ambiguity problem.

Additionally, spectral and autocorrelation terms still reside near DC, which allows them to be removed by high-pass filtering. While it is also possible, in principle, to upshift the cross-interferometric signal by placing the sample focus at a large pathlength mismatch, this physical pathlength mismatching leads to significant signal attenuation due to amplitude falloff secondary to finite source linewidths. 4,5 We also show that complex conjugate ambiguity resolution via frequency shifting is immune to this falloff phenomenon. 2. Imaging Depth 2. THEORETICAL ANALYSIS The imaging depth achieved using FDOCT systems is described in two ways; the maximum imaging depth and falloff. The maximum imaging depth in FDOCT systems is related to 2 : z = max δ k () 4 s where z max is the maximum imaging depth where aliasing causes signals from deeper reflectors to fold onto itself. δ s k is defined as the spectral sampling interval of the FDOCT system. In SDOCT systems, the spectral sampling interval is limited by the pixel spacing of the CCD. For SSOCT systems, the spectral sampling interval is only limited by the sampling rate of the analog-digital acquisition board. The second parameter that determines the imaging depth of FDOCT systems is falloff. Falloff is caused by fringe washout and it describes the SNR degradation as a function of imaging depth. The -3dB falloff point which was derived from falloff analysis reported by Yun, et., al. 7 is given by: 2ln2 z 3dB = (2) δ k where z -3dB is the imaging depth at which the SNR is reduced by half. δ r k is the spectral resolution of the FDOCT system. In SDOCT, the spectral resolution is limited by the spectrometer optics and/or the pixel width of the CCD. For SSOCT systems, the spectral resolution is defined by the instantaneous linewidth of the swept laser source. Swept laser sources with linewidths smaller than the resolution of SDOCT spectrometers are readily available and therefore give SSOCT an over two-fold imaging depth advantage over SDOCT techniques. Imaging depth capabilities over 4mm can be valuable for applications such as endoscopy, small animal imaging, and human anterior segment imaging. 2.2 Heterodyne SSOCT In FDOCT, the photocurrent signal generated by n reflectors is related to i( k) S( k) RR + Rn + 2 RR Rn cos( 2k[ zr zn] ) + 2 RR n m cos( 2k[ zn zm] ) (3) n n n m n Here, i(k) is the detector photocurrent as a function of optical wavenumber k; S(k) is the source power spectral density; R R and R n are the reflectivities of the reference and n th sample reflector, respectively; and z R and z n are the positions of the reference and n th sample reflector, respectively. The first two terms in the brackets on the right-hand side represents non-interferometric spectral artifact. The third term represents the cross-interferometric terms, and the fourth term represents the autocorrelation artifact. Wavenumber is parameterized by time t by the relationship k=k o +t(dk/dt), where k o is the starting wavenumber and dk/dt is the sweep velocity. This sweeping leads to the conversion of pathlength differences in the auto- and cross-terms to an electronic beat frequency in i(t), the time -varying photocurrent. The cross frequencies have instantaneous values of ω n =(dk/dt)[z R - z n ], while the auto frequencies have instantaneous values of ω nm =(dk/dt)[z n z m ]. If the reference arm optical field is shifted by some frequency ω D, then the time-varying photocurrent becomes: i( t ) S ( t) RR + Rn + 2 RR Rn cos( [ ωn + ωd ] t + φn ) + 2 RnRm cos( ωnmt + φnm ) (4) n n n m n where φ n =k o [z n -z m ] and φ nm =k o [z n -z m ]. After frequency shifting, the autocorrelation and source spectral terms remain centered at baseband, while the cross-interference terms are recentered around ω D. While the Fourier transform of i(t) remains Hermitian symmetric, the transform of fringes generated by pathlength differences of equal magnitude but opposite sign no longer overlap. This resolves complex conjugate ambiguity because positive displacements are above r

ω D, while negative displacements are below ω D as long as ω D is larger than the maximum ω n. If the wavenumber sweep is linear over a bandwidth sweep k that takes t seconds to complete, then ω D corresponds to a pathlength shift of z D =ω D t/(2 k). This shift does not lead to signal falloff. Falloff in SSOCT occurs because the interferometric signal is integrated over the source linewidth at the photodiode. If the source linewidth is on the order of 2π/(z R - z n ), then the linewidth spans an appreciable portion of the interferometric fringe. This decreases the fringe visibility, which decreases the peak height in the Fourier transform of i(t). Frequency shifting creates a time-varying beat frequency that is independent of sweep speed or source linewidth and, as such, it is not susceptible to falloff. The cross-interferometric signal can be recovered by band pass filtering around ω D with a noise equivalent bandwidth of NEB=2z max k/ t. If demodulation is performed, the band-passed signal is mixed with orthogonal local oscillators with frequency ω D, then the real and imaginary parts of the complex interferometric signal can be recovered: ( ) = 2 ( ) cos( ω + φ ) i t S t R R t re R n n n ( ) = 2 ( ) sin ( ω + φ ) i t S t R R t im R n n n. (5) Additionally, demodulation enables wavenumber triggering 8,9 of the above interferometric signals, thereby eliminating the need to resample the data in software. Finally, it should be noted that an analogous technique for complex conjugate ambiguity removal could be implemented in SDOCT by use of spatial heterodyning and demodulation techniques. 3. EXPERIMENTAL SETUP We constructed the heterodyne SSOCT setup shown in Fig. using a fiber-based swept laser source (Micron Optics, Inc. λ o =3nm, λ=nm, 25Hz sweep rate), acousto-optic modulators (IntraAction, Corp.), and a New Focus balanced photodetector. The acousto-optic modulators (AOs) had a common center frequency of MHz, one having a useradjustable offset from that frequency. The diffraction efficiency of the AOs was measured to be 6%, and using the simple optical setup depicted in the figure, the maximum diffracted optical bandwidth recoupled was 64nm. Spectral interferogram samples evenly spaced in wavenumber were clocked into the data acquisition system by using a fiber Fabry-Perot interferometer. The heterodyne interferometric signal is high-pass filtered to remove the spectral and autocorrelation artifacts then demodulated by mixing with a local oscillator (LO) of frequency ω d. The inphase and quadrature components are lowpass filtered and digitized. The output power of the swept-laser source was 5µW. There was approximately -6dB source power attenuation in the system prior to the sample, resulting in 5µW illumination on the sample (cornea). The SNR of the system, near zero pathlength difference, with a -6dB reflector, was measured to be 99dB. The predicted SNR was 2dB. Note, the power on the eye is significantly lower than allowable, therefore the SNR of the system could be greatly increased by use of a higher power laser source. Figure. Heterodyne swept-source OCT system utilizing acousto-optic modulators. The swept-laser source has a center wavelength λ o =3nm and bandwidth λ=nm. A balanced detector is used for DC artifact suppression. FFPI: fiber Fabry-Perot interferometer; PC: polarization controllers; AO: acousto-optic modulator; C: circulator; CASS: anterior segment scanner.

.5.5 a + 5um Displacement - 5um Displacement khz Frequency Shift.5.5 b -.5 -.5 Amplitude (a.u.) - - -.5 -.5.5.33.5.33.5 c 2kHz Frequency Shift.5 d.5.5 -.5 -.5 - - -.5.5.33 -.5.5.33.5.33 Wavenumber Offset (/cm) Figure 2. Interferograms taken using heterodyne SSOCT. (a) and (b) are taken from a reflector at +5µm and -5µm pathlength difference, respectively with a khz frequency shift. (c) and (d) are collected at the same pathlength difference, but with a 2kHz frequency shift. By using heterodyne detection, reflectors at positive positions produce higher fringe frequencies than those at negative positions and therefore are unambiguously resolved. 4. RESULTS To illustrate the behavior of the cross-interferometric term in Eq. 3 with the reference arm frequency shifted with respect to the sample arm, we show in Fig. 2 the fringe patterns of typical interferograms at two pathlength differences, centered around zero, with no frequency shift (Fig 2(a) and 2(b)), and with 2kHz frequency shift (Fig 2(c) and 2(d)). The fringe frequency for the cross-correlation term, when ω D =, is identical for positive and negative equal displacements, and is thus ambiguous. However, when ω D = 2kHz, the fringe frequency for the positive displacement is higher than for a negative displacement, as expected from Eq. 4. Figure 3 illustrates that the signal falloff remains centered at zero pathlength difference, even as the electronic frequency is shifted. Figure 3(a) shows falloff centered at zero pathlength and zero frequency for homodyne SSOCT. By shifting the zero pathlength difference frequency to MHz (Fig. 3(b)), the image contents are moved away from DC and therefore removal of DC and auto-correlation artifacts is achieved. In Fig. 4, removal of complex conjugate ambiguity and DC artifacts is demonstrated using heterodyne SSOCT. Using a 5dB sample reflector placed at 2.mm pathlength difference, the complex conjugate ambiguity is clearly shown in the A-scan acquired using homodyne SSOCT (Fig 4(a)). Residual DC artifact is also present in the A-scan. By upshifting the frequency of the reference arm by 4kHz, the complex conjugate ambiguity is completely resolved down to the noise floor of the system (Fig. 4(b)). In Fig. 4(b), the reflections located near zero pathlength difference originates from a neutral density filter. In vivo images acquired using homodyne and heterodyne SSOCT techniques are shown in Fig. 5(a) and 5(b), respectively. Figure 3. Falloff measurements for (a) homodyne and (b) heterodyne SSOCT. Heterodyne SSOCT enables frequency shifting of zero pathlength difference away from DC and auto-correlation artifacts, while falloff stays centered around zero pathlength difference. 5 db reflector used in sample arm.

-4. -3. Homodyne SSOCT C Heterodyne SSOCT. Depth (mm) -2. -.. S 2. 3. 4. 5. Depth (mm) 2. 3. I 6. 7. Figure 4. A-scans of a 5dB reflector at 2.mm pathlength difference. (a) A-scan showing unresolved complex conjugate ambiguity (CCA) acquired using homodyne SSOCT. The CCA prevents distinguishing reflectors at +2.mm from those at 2.mm depth. Using heterodyne SSOCT (b), the CCA is resolved down to the noise floor of the system. The echo is a double-pass reflection from the ND filter, and shifts with the main reflector peak. 4. 8.. 2. 3. 4. 5. 6.. 2. 3. 4. 5. 6. Lateral Position (mm) Lateral Position (mm) Figure 5. In vivo images of human anterior segment using (a) homodyne and (b) heterodyne SSOCT techniques. Complete complex conjugate ambiguity removal and doubling of the imaging depth is shown to be necessary in order to visualize the entire anterior segment of the eye. C: cornea; S: sclera; I: iris. These images are of the anterior segment of a human eye and were acquired at a rate of 25 Hz. In the homodyne SSOCT image the iris, cornea, and sclera are hidden by the mirror image that arises from the complex conjugate artifact. Using heterodyne SSOCT, however, the artifact is completely removed and the cornea, iris, and sclera are no longer obscured. It is also clear that at least 6mm imaging depth is necessary to visualize the entire anterior segment. 5. CONCLUSIONS In summary, we have demonstrated heterodyne SSOCT using acousto-optic modulators for complex conjugate ambiguity and DC artifact removal. This technique allows for zero pathlength difference C to be shifted away from electronic DC with no penalty due to finite laser linewidth falloff. Combined with coherent demodulation, this technique provides access to the entire complex interferometric signal as well as enables wavenumber triggering, S thereby eliminating the need for resampling the data in software. We have shown that this technique is essential for human anterior segment imaging applications where more than 6mm imaging depth is necessary. ACKNOWLEDGEMENTS I We gratefully acknowledge support for this work through a grant from the National Institute of Health, R2 EB243. REFERENCES. Leitgeb, et. al., Opt. Exp. (8), 889-894 (23). 2. Choma, et. al., Opt. Exp. (8), 283-289 (23). 3. de Boer, et. al., Opt. Lett. 28(2), 267-269 (23). 4. Wojtkowski, et. al., Opt. Lett. 27(6), 45-47 (22). 5. Choma, et. al., Opt. Lett. 28(22), 262-264 (23). 6. Sarunic, et. al., Proceedings of SPIE, San Jose, CA (24). 7. Yun, et. al., Opt. Exp., (26), 3598-364 (23). 8. Choma, et. al., Proceedings of SPIE, San Jose, CA (24). 9. Choma, et. al., J. Biomed. Opt., in press.