For Immediate Delivery call KMParts.com at (866)

Similar documents
CP-T range Product group picture

Switching power supplies CP range, Linear power supplies CP-L range. Content

CP-T range Benefits and advantages

Type CP-S, CP-C & CP-A Switch mode

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

CP-E range Benefits and advantages

Power supply CP-E 24/0.75

Power supply CP-D 24/4.2 Primary switch mode power supply

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Power supply CP-E 24/2.5

Power supply CP-D 24/1.3

QUINT-PS-24DC/24DC/10

Power supply CP-T 24/20.0 Primary switch mode power supply

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

MINI-PS AC/24DC/1.3

Power supply CP-D 12/2.1

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

Primary switch mode power supplies Product group picture

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Transformers, Power Supply Units and Socket Outlets

QUINT-PS AC/24DC/40

Power supply CP-T 48/5.0 Primary switch mode power supply

QUINT-PS/ 3AC/24DC/10

Output Voltage* (nom.)(adjustable)

Electronic timer CT-TGD.22

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDD.22

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

MINI-PS AC/2X15DC/1

Electronic timer CT-SDS.22

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

General technical data. Pollution degree 2. EMC / shock / vibration Noise emission acc. to EN Electrical safety (applied standards)

QUINT-PS/ 3AC/24DC/40

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Three-phase monitoring relays CM-PFE and CM-PFE.2

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

Three-phase monitoring relays

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

QUINT-PS/ 1AC/24DC/20

02/11/2015

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

02/11/2015

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

X Series Data Sheet 375, 500 Watt AC-DC and DC-DC DIN-Rail Converters

TRIO-PS-2G/1AC/24DC/5

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

Three-phase monitoring relay CM-PFS

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Thermistor motor protection relays

CB Scheme UL508 UL ATEX II3G

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Installation / Monitoring Technique

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Subject to changes 11/2003 Page 1/7

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

wenlok.com.mx Switched-mode and uninterruptible power supplies, and electronic fuses Let s connect. Power supply Catalogue 2015/2016

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Three-phase monitoring relay

IBS IP CDIO/R 24-8 IBS IP CDIO/R 24-8/SF

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Datasheet. PRO-M Series Power Supplies

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

Electronic timer CT-MFS.21

Overcurrent Protection / 7SJ45

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

Output Voltage nom. (adjustable)

Thermistor motor protection relays

Transcription:

Contents 9/1 Page Description SN4 switched-mode power supply units 9/2 GW4 power supply units 9/3 GD4 power supply units 9/4 Basic Units, Accessories 9/5 Technical data 9/6 Dimensions 9/12

9/2 Description SN4 switched-mode power supply units 115 V N L1 Fault Power + 24 V U 0 V 0 V Type overview SN4-025-BI7 Rated output current: 2.5 A Application SN4-050-BI7 Rated output current: 5 A Switched-mode power supply units can be used in most mains supplies in use around the world. Key features of these devices are: variable input voltage and frequency, regulated output voltage, high efficiency, low weight, short-circuit and overload-proof DC output. Features Single-phase Variable primary voltage and frequency of 115/230 V AC, 50/60 Hz Stabilized output voltage of 24 V DC Output power 60 W or 120 W Two, suitable for parallel connection to increase power output or for redundant operation Safe isolation between primary and secondary sides as per IEC/EN 60950 Interference suppression complies with EN 50081-1 Class B EMC requirements for public and industrial electricity networks PFC (Power Factor Correction) in accordance with IEC/EN 61000-3-2, to prevent harmonics being fed back into the supply network as interference Short-circuit- and overload-proof DC output Automatic restart on short-circuit and overload UL and CSA approvals

Description GW4 power supply units 9/3 L1 N + 24 V 0 0 V H Type overview GW4-030-BA3 GW4-050-BA3 GW4-080-BA3 GW4-100-BA3 Rated output current: 3 A Rated output current: 5 A Rated output current: 8 A Rated output current: 10 A Application The GW4 AC power supply units are used mainly with fixed frequency, constant voltage mains supplies. Safe isolation and a high level of insensitivity to electrical disturbances are the distinguishing features of these units. Features AC power supply units, single-phase Primary voltage 230 V AC, 50/60 Hz Non-stabilized output voltage 24 V DC Output power 72 to 240 W (depending on type) Safe isolation between primary and secondary sides as per IEC/EN 60742 Interference suppression complies with EN 50081-1 Class B EMC requirements for public and industrial electricity networks

9/4 Description GD4 power supply units + 5% + 5% + 5% L1 L2 L3-5% - 5% - 5% + 24 V 0 0 V H Type overview GD4-050-BA3 GD4-100-BA3 GD4-150-BA3 GD4-200-BA3 GD4-300-BA3 Rated output current: 5 A Rated output current: 10 A Rated output current: 15 A Rated output current: 20 A Rated output current: 30 A Application The GW4 three-phase power supply units are used mainly with fixed frequency, constant voltage mains supplies. Safe isolation and a high level of insensitivity to electrical disturbances are the distinguishing features of these units. Features Three-phase power supply units Primary voltage 3 x 400 V AC 50/60 Hz Non-stabilized output voltage 24 V DC Output power: 120 to 720 W (depending on type) Safe isolation between primary and secondary sides as per IEC/EN 60742 Interference suppression complies with EN 50081-1 Class B EMC requirements for public and industrial electricity networks 2 x +24 V, 3 x 0 V terminals on types GD4-150-BD3, GD4-200-BD3 and GD4-300-BD3

Basic Units, Accessories 9/5 Rated input voltage 50/60 Hz Rated output voltage (residual ripple) V AC V DC A Rated output current Type Article no. GW4 and GD4 power supply units 1-phase, unregulated, smoothed (GW4) 230 24 (g 5%) 3 GW4-030-BA3 200016 230 24 (g 5%) 5 GW4-050-BA3 200017 230 24 (g 5%) 8 GW4-080-BA3 200018 230 24 (g 5%) 10 GW4-100-BA3 200019 Price See Price List Std. pack 1 off 3-phase, unregulated, smoothed (GD4) 400 (g 5%) 24 (g 3%) 5 GD4-050-BD3 200007 1 off 400 (g 5%) 24 (g 3%) 10 GD4-100-BD3 200009 400 (g 5%) 24 (g 3%) 15 GD4-150-BD3 200011 400 (g 5%) 24 (g 3%) 20 GD4-200-BD3 200012 400 (g 5%) 24 (g 3%) 30 GD4-300-BD3 200014 SN4 switched-mode power supply units Primary-switched mode, stabilized 2 units can be wired in parallel to increase power, or to provide redundant operation at rated power 115/230 24 (g 3%) 2.5 SN4-025-BI7 200033 1 off 115/230 24 (g 3%) 5 SN4-050-BI7 200034 1 off Accessories SN4 Mounting feet ZB4-101-GF1 061360 9 off Twin-level terminal block ZB4-122-KL1 052101 Mounting bracket for 90 installation ZB4-220-MW1 214624 2 off 1 off

9/6 Technical Data Technical data 9/7 GD4 power supply units with transformer GW4 power supply units with transformer GD4-050-BD3 GD4-100-BD3 GD4-150-BD3 GD4-200-BD3 GD4-300-BD3 GW4-030-BA3 GW4-050-BA3 GW4-080-BA3 GW4-100-BA3 General Protection class 1 1 Potential isolation Yes, VDE 0551, IEC/EN 60742, SELV Yes, VDE 0551, IEC/EN 60742, SELV Supply frequency Nominal value Hz 50/60 50/60 Range Hz 50 60 Electromagnetic compatibility (EMC) Emitted interference Class B (EN 55011, 22) Class B (EN 55011, 22) ESD 6 kv contact (Level 3), 8 kv air (Level 3), IEC/EN 61000-4-2 6 kv contact (Level 3), 8 kv air (Level 3), IEC/EN 61000-4-2 RFI 10 V/m, modulated, IEC/EN 61000 4-2 10 V/m, modulated, IEC/EN 61000 4-2 Burst 2 kv (Level 3) IEC/EN 61000-4-4 2 kv (Level 3) IEC/EN 61000-4-4 Surge 2 kv (Inst. Class 3), IEC/EN 61000-4-5 2 kv (Inst. Class 3), IEC/EN 61000-4-5 Surge voltage 4.9 kv, IEC EN 60947 4.9 kv, IEC EN 60947 Environmental data Ambient temperature C -25/55-25/55 Ambient temperature for storage C -25/85-25/85 Pollution degree 2, EN 50178 2, EN 50178 Vibration 0.075 mm (10-57 Hz), 10 cycles, IEC 60 068-2-6 0.075 mm (10-57 Hz), 10 cycles, IEC 60 068-2-6 Shock resistance, shock duration 11 ms g 15, IEC 60 068-2-27 (3 shocks) 15, IEC 60 068-2-27 (3 shocks) Altitude m Max. 2000 m a.m.s.l., observe derating above this Max. 2000 m a.m.s.l., observe derating above this Degree of protection IP20 IP20 Fixing Screw fixing Screw fixing Mounting position As required As required Input voltage Nominal value V AC 400 400 400 400 400 230 230 230 230 Range V AC Taps g 5% 380, 400, 420 230 230 230 230 Nominal input current per phase A 0.24 0.46 0.65 0.9 1.8 0.45 0.8 1.2 1.4 Off-load losses W 5 14.2 13.9 25.5 38.2 7.6 9 12.8 10.2 Short-circuit losses W 19.6 28.6 44.2 59 55.5 15.5 29.7 32.7 35 Output voltage Nominal value V DC 24 24 24 24 24 24 24 24 24 Tolerance Tolerance Residual ripple % F 3 F 3 F 3 F 3 F 3 F 5 F 5 F 5 F 5 Output current (nominal) 1) A 5 10 15 20 30 3 5 8 10 Output current range at 55 C A 0 5 0 10 0 15 0 20 0 30 0 3 0 5 0 8 0 10 Terminal capacity Solid mm 2 0.5 4 0.5 4 0.5 4 0.5 4 0.5 4 0.5 4 0.5 4 0.5 4 0.5 4 Flexible with ferrule mm 2 0.5 2.5 0.5 2.5 0.5 2.5 0.5 2.5 0.5 2.5 0.5 2.5 0.5 2.5 0.5 2.5 0.5 2.5 Connections Screw connection Screw connection Screw connection Screw connection Screw connection Screw connection Screw connection Screw connection Screw connection Dimensions Width mm 125 155 155 190 190 85 85 106 121 Height mm 73 82 97 105 115 90 98 100 105 Depth mm 140 170 170 225 240 122 135 151 169 Weight kg 2.4 4.4 5.8 7.6 11.2 2 2.5 3.65 4.45 Notes 1) Derating From +44 to +55 C: linear derating of power from 100 % to 93 %

9/8 Technical Data Technical data 9/9 GD4 power supply units with transformer GW4 power supply units with transformer GD4-050-BD3 GD4-100-BD3 GD4-150-BD3 GD4-200-BD3 GD4-300-BD3 GW4-030-BA3 GW4-050-BA3 GW4-080-BA3 GW4-100-BA3 Protective element Input voltage U 1 V 3 x 400 3 x 400 3 x 400 3 x 400 3 x 400 230 230 230 230 Input current I A 0.24 0.46 0.65 0.9 1.8 0.45 0.8 1.2 1.4 Circuit-breaker PKZ PKZM0-0,25 PKZM0-0,63 PKZM0-1 PKZM0-1 PKZM0-2,5 PKZM0-0,63 PKZM0-1 PKZM0-1,6 PKZM0-1,6 Current setting A 0.24 0.46 0.65 0.9 1.8 0.45 0.8 1.2 1.4 Miniature circuit-breaker FAZ FAZ-S1/1 FAZ-S1/1 FAZ-S1/1 FAZ-S1/1 FAZ-S2/1 FAZ-S1/1 FAZ-S1/1 FAZ-S2/1 FAZ-S2/1 Short-circuit protection only K K K Current/voltage 1) e 29 28 27 26 25 24 23 22 21 20 0 1 e 28 27 26 25 24 23 22 21 20 0 1 Notes 1) At 230 V or 3 x 400 V AC (primary side) and a load current of I = 0 A up to the rated current 1 x I e

9/10 Technical Data Switched-mode power supply units SN4-025-BI7 (115 V/230 V) SN4-050-BI7 (115 V/230 V) General Mains failure bridging ms > 10 at 50 Hz, 187 V > 8.33 at 60 Hz, 92 V > 10 at 50 Hz, 187 V > 8.33 at 60 Hz, 92 V Protection Class U out against U in Class I, IEC 60 536 Class I, IEC 60 536 Potential isolation Yes, SELV as per IEC/EN 60950 Yes, SELV as per IEC/EN 60950 Efficiency At 115 V 0.84 0.86 At 230 V 0.86 0.87 Power consumption At 115 V W 71 136 At 230 V W 69 134 Power loss At 115 V W 12 19 At 230 V W 10 17 Short-circuit recognition A Approx. 7 at 80 ms Approx. 14 at 80 ms Overload detection A Approx. 3.5 Approx. 7 Special application 2 units can be wired in parallel to increase power, or to provide redundant operation at rated power 2 units can be wired in parallel to increase power, or to provide redundant operation at rated power Input voltage Nominal value V AC 115, 230 115, 230 Range V AC 92 to 132 187 to 264 92 to 132 187 to 264 Cooling-off time s Input side 120, current limiting on primary side Input side 120, current limiting on primary side Supply frequency Nominal value Hz 50/60 50/60 Range Hz 47 63 47 63 Output voltage Nominal value V DC 24 24 Tolerance % g 3 g 3 Residual ripple mv ss < 150 < 150 Switching peaks mv SS < 240 < 240 Short-circuit protection Yes Yes Proof against sustained short circuit Yes Yes Response to short-circuit Automatic restart attempt every 2 seconds Automatic restart attempt every 2 seconds Off-load test Yes Yes Electromagnetic compatibility (EMC) Emitted interference Class B, EN 50081-2 Class B, EN 50081-2 ESD 6 kv contact (Level 3), IEC/EN 61000-4-2, 8 kv air (Level 3), IEC/EN 61 000-4-2 6 kv contact (Level 3), IEC/EN 61000-4-2, 8 kv air (Level 3), IEC/EN 61000-4-2 RFI 10 V/m, modulated, IEC/EN 61000-4-3 10 V/m, modulated, IEC/EN 61000-4-3 Burst 2 kv (Level 3), IEC/EN 61000-4-4 2 kv (Level 3), IEC/EN 61000-4-4 Surge 2 kv (Inst. Class 3), IEC/EN 61000-4-5 2 kv (Inst. Class 3), IEC/EN 61000-4-5 Surge voltage 4.9 kv, IEC/EN 60947 4.9 kv, IEC/EN 60947 Conducted RFI (IEC 61 000-4-6) V 10 V/m, ENV 50 141 10 V/m, ENV 50 141 Supply harmonic currents power factor correction (PFC) Yes, IEC/EN 61000-3-2 Yes, IEC/EN 61000-3-2 Displays Display 24 V DC (power) (LED) Yellow Yellow Display overload/short-circuit (FAULT) (LED) Red Red Environmental data Ambient temperature C 0 55 0 55 Storage C 25 85 25 85 Pollution degree 2, EN 50178 2, EN 50178 Vibration 0.15 mm, 20 cycles, 10 150 Hz, IEC 60 068-2-6 0.15 mm, 20 cycles, 10 150 Hz, IEC 60 068-2-6 Shock resistance, shock duration 11 ms g 15, IEC 60 068-2-27 (3 shocks) 15, IEC 60 068-2-27 (3 shocks) Altitude m Max. 2000 m a.m.s.l., observe derating above this Max. 2000 m a.m.s.l., observe derating above this Degree of protection IP20 IP20 Fixing DIN rail (EN 50022), DIN rail (EN 50022), screwed on with ZB4-101-GF1 screwed on with ZB4-101-GF1

Technical Data 9/11 Switched-mode power supply units SN4-025-BI7 (115 V/230 V) SN4-050-BI7 (115 V/230 V) Mounting position DIN rail Horizontal, vertical (observe derating) Horizontal, vertical (observe derating) Mounting feet Any (observe derating) Any (observe derating) Input current Input current At 115 V A 1.1 2.1 At 230 V A 0.5 0.9 Switch-on current (25 C) At 115 V A 5 10 At 230 V A 15 30 Fuse in primary side, minimum requirements At 115 V FAZ-C2/1 FAZ-B6/1 FAZ-C3/1 At 230 V FAZ-C3/1 FAZ-C4/1 FAZ-C4/1 Output current Output current, nominal value A 2.5 horizontal, vertical (derating), from +40 C to +55 C linear power derating from 100 % to 80 % 5 horizontal, vertical (derating), from +40 C to +55 C linear power derating from 100 % to 80 % Range 0 to +55 C A 0 to 2.5 horizontal; vertical (derating) 0 to 5 horizontal; vertical (derating) Terminal capacity Solid mm 2 0.75 4 0.75 4 Flexible with ferrule mm 2 0.5 2.5 0.5 2.5 Connections Screw connection Screw connection Dimensions Width mm 135 215 Height mm 85 85 Depth mm 85 85 Weight kg 0.8 1.2

9/12 Dimensions GW4 GD4 c + 5 1) g e a c + 5 1) b 1 b ± 5 1) f b 1 b1 b ± 5 1) 1) Maximum space requirements Type a b b1 c e f g GW4-030-BA3 050-BA3 080-BA3 100-BA3 GD4-050-BD3 100-BD3 150-BD3 200-BD3 300-BD3 85 85 106 121 125 155 155 190 190 85 93 95 100 68 77 92 100 110 74 83 87 86 61 77 92 83 103 130 130 146 164 135 165 165 220 235 64 64 80.5 90 100 130 130 170 170 60.5 69 69.5 70 45 57 72 58 78 4.8 4.8 5.8 5.8 5 8 8 8 8 Accessories Two-level terminal block ZB4-122-KL1 22 70 38.6 Mounting bracket ZB4-220-MW1 110 70 139 50 10 220 81