MiniFlex MF HF MF HF FLEXIBLE AC CURRENT SENSOR. User Manual. High Frequency Response for Oscilloscopes

Similar documents
MiniFlex MF MF FLEXIBLE AC CURRENT SENSOR. User Manual

FlexProbe FLEXIBLE AC CURRENT PROBE. User Manual. FlexProbe ON OL 1000V CAT III 300A 3000A OFF

AC/DC Current Oscilloscope Probe Model SL261

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

AC/DC Current Probes Model MR411 Model MR521

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

MR461 MR561 AC/DC OSCILLOSCOPE CURRENT PROBES. User Manual. AC/DC CURRENT PROBE Model MR 561. AC/DC CURRENT PROBE Model MR V CAT III - 600A

MEGOHMMETER. User Manual

QUICK TESTER FOR TRANSFORMERS AND CAPACITORS

CLAMP-ON METER 670. User Manual

GROUND FAULT/LEAKAGE DETECTOR

FLEXIBLE CURRENT PROBES

DIGITAL MULTIMETER with Non-Contact Detection

DIGITAL MULTIMETER with Non-Contact Detection

Flexible AC current probes

DIGITAL ANALOG MEGOHMMETERS

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

AC Digital Signal Generator Model DSG-8 User Manual

Clamp-On Ground Resistance Tester Model 3705

with the Artifical Neutral AN-1

1210N 1250N MEGOHMMETER. User Manual 15 V 500V kV. MEGOHMMETER Model 1250N 600V CAT II / 1000V CAT I! 30. x 10.

80i-110s AC/DC CURRENT PROBE

Digital Multimeter Models 5212, 5215 & 5217

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

K1 K2. User's manual AC/DC CURRENT PROBE C H A U V IN A R N O U X AC/DC CURRENT PROBE. 1 mv/ma OFF 300V CAT II

MODEL 3620 GROUND RESISTANCE TESTER. User Manual. Shop for AEMC products online at: Press To Measure C1 P2 C2

Agilent 1146A AC/DC Oscilloscope Current Probe

Operator s Manual. PP016 Passive Probe

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

Cable Locator Transmitter/Receiver Model 6681

BENNING. CM7 Electrical Tester. Service Information

Clamp-On Ground Resistance Tester Models 3711 and 3731 USER MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

PHV RO High Voltage Passive Probe. Instruction Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Operator s Manual. PP022 Passive Probe

400 MHz Passive High-Voltage Probe R&S RT-ZH

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

HZ 115. Differential probe for oscilloscopes. C E IEC 1010 Cat III

TA MHz oscilloscope probe TA MHz oscilloscope probe

80i-110s. AC/DC Current Probe Instructions. Introduction

User s Manual Current Probe. IM E 2nd Edition IM E

AC FLEXIBLE CURRENT PROBE CA 3000

Multi range AC current clamps (1000A / 100A / 5A / 0.5A) A 1281 Instruction manual Version 2.0, Code no

PKT 512A-RO High Impedance Passive Cable Divider

Operator s Manual. PP017 and PP018 Passive Probes

Mini Clamp Meter Model:

RIGOL. User s Guide. RP1000D Series High Voltage Differential Probe. Feb RIGOL Technologies, Inc

INSTRUCTION MANUAL UTL260

Digital Ground Resistance Tester. Model 4610 & 4610 Kits

User s Guide. Model MA A AC Mini Clamp-on Meter

200Amp AC Clamp Meter + NCV Model MA250

Preface First of all, thank you for purchasing our products, this instruction manual is the description about the function, usage, operation attention

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

User s Manual Current Probe IM E. 8th Edition

MODEL 3810/2 Line Impedance Stabilization Network

User s Manual Current Probe IM E. 6th Edition

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

USER MANUAL. DC 13kHz High Voltage Amplifier WMA V to +175V output. Stable with all capacitive loads, generates no overshoot

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

DC/AC Current clamp 2000A A 1636 Instruction manual Version 1.2, Code no

374 FC/375 FC/376 FC Clamp Meter

INSTRUCTION MANUAL CLAMP ON PROBE

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

DM-46 Instruction Manual

SERIE E N. The E N series clamps use Hall-effect technology for the measurement of AC and DC currents from several milliamps to over 100 A.

MODEL W Power Amplifier

3B SCIENTIFIC PHYSICS

T5-600/T Electrical Tester

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

Model 4007DDS. 7 MHz Sweep Function Generator

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, this instruction manual is the description about t

TT-SI MHz Active Differential Probe

Wide-band Models from DC to 100 MHz

Preface Shenzhen Zhiyong Electronics Co., Ltd. First of all, thank you for purchasing our products, the product specification is about the function, u

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

User s Guide. 400A AC/DC Clamp Meter. Model MA220

RIGOL. User s Guide. RP1003C/RP1004C/RP1005C Current Probe. Mar RIGOL Technologies, Inc

AC/DC CLAMP METER USER S MANUAL

Measure voltage without test leads. Product Highlights

Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga

DDM350 Pen-Type Digital Multimeter User s Manual

Dawson DDM190. Digital Multimeter User s Manual

PT-2000series AC/DCcurrentprobe PT-2710 PT-2720 PT-2740 PT-2770 MANUAL INSTRUCTION

Current clamps for AC current

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Agilent N2780A, N2781A, N2782A, and N2783A Current Probes

10.00 (1/2) PAC series

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

HHMA2 DC / TRUE RMS AC NON-CONTACT MILLIAMMETER

E2621A and E2622A Probe Adapters for Infiniium Oscilloscopes. User s Guide. Publication number E September 2002

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

Transcription:

FLEXIBLE AC CURRENT SENSOR High Frequency Response for Oscilloscopes MiniFlex MF 300-6-2-10-HF MF 300-10-2-10-HF E N G L I S H User Manual

Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards. We guarantee that at the time of shipping your instrument has met its published specifications. An NIST traceable certificate may be requested at the time of purchase, or obtained by returning the instrument to our repair and calibration facility, for a nominal charge. The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer. For recalibration, please use our calibration services. Refer to our repair and calibration section at www.aemc.com. Serial #: Catalog #: 2126.83 / 2126.84 Model #: MF 300-6-2-10 HF/ MF 300-10-2-10-HF Please fill in the appropriate date as indicated: Date Received: Date Calibration Due: Chauvin Arnoux, Inc. d.b.a AEMC Instruments www.aemc.com

Table of Contents 1. INTRODUCTION... 2 1.1 International Electrical Symbols...3 1.2 Definition of Measurement Categories...3 1.3 Receiving Your Shipment...4 1.4 Ordering Information...4 1.4.1 Accessories and Replacement Parts...4 2. PRODUCT FEATURES... 5 2.1 Description...5 2.2 Features...6 2.3 Control Features...7 3. SPECIFICATIONS... 8 3.1 Typical Response Curves...10 3.1.1 Frequency Error...10 3.1.2 Amplitude Error...11 4. OPERATION... 12 4.1 Compatibility...12 4.2 Tips for Making Precise Measurements...12 4.3 Making Measurements...13 5. MAINTENANCE... 14 5.1 Maintenance...14 5.1.1 Battery Replacement...14 5.1.2 Cleaning...14 Repair and Calibration...15 Technical and Sales Assistance...15 Limited Warranty...16 Warranty Repairs...16 MiniFlex Flexible AC Current Probe 1

CHAPTER 1 INTRODUCTION WARNING These safety warnings are provided to ensure the safety of personnel and proper operation of the instrument. Read this instruction manual completely and follow all the safety information before attempting to use or service this instrument. Safety is the responsibility of the operator. The MiniFlex must be used only by qualified personnel using applicable safety precautions. Wear protective clothing and gloves as required. Use caution on any circuit: potentially high voltages and currents may be present and may pose a shock hazard. Read the safety specifications section prior to using the current probe. Never exceed the maximum voltage ratings given. ALWAYS de-energize the circuit before wrapping the MiniFlex around bare conductors, bus bars, or near live parts. Do not wrap on live conductors. ALWAYS connect the electronic module to the display device before wrapping the MiniFlex around the sample being tested. ALWAYS inspect the module, sensor, sensor cable, and output terminals prior to use. Replace any defective parts immediately. Use only factory parts. NEVER use the MiniFlex on electrical conductors rated above 1000V CAT III; 600V CAT IV. 2 MiniFlex Flexible AC Current Probe

1.1 International Electrical Symbols This symbol signifies that the instrument is protected by double or reinforced insulation. This symbol on the instrument indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument. In this manual, the symbol preceding instructions indicates that if the instructions are not followed, bodily injury, installation/sample and product damage may result. Risk of electric shock. The voltage at the parts marked with this symbol may be dangerous. This symbol refers to a type B current sensor. Do not apply around or remove from HAZARDOUS LIVE conductors without additional protective means (deenergizing the circuit or wearing protective clothing suitable for high voltage work). Battery Compliance with the Low Voltage & Electromagnetic Compatibility European directives (73/23/CEE & 89/336/CEE) In the European Union, this product is subject to a separate collection system for recycling electrical and electronic components In accordance with directive WEEE 2002/96/EC 1.2 Definition of Measurement Categories CAT II: For measurements performed on circuits directly connected to the electrical distribution system. Examples are measurements on household appliances or portable tools. CAT III: For measurements performed in the building installation at the distribution level such as on hardwired equipment in fixed installation and circuit breakers. CAT IV: For measurements performed at the primary electrical supply (<1000V) such as on primary overcurrent protection devices, ripple control units, or meters. MiniFlex Flexible AC Current Probe 3

1.3 Receiving Your Shipment Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, giving a detailed description of any damage. Save the damaged packing container to substantiate your claim. 1.4 Ordering Information MiniFlex 30/300A, 6", 100mV/10mV/A High Frequency (for use with any BNC Oscilloscope)...Cat. #2126.83 MiniFlex 30/300A, 10", 100mV/10mV/A High Frequency (for use with any BNC Oscilloscope)...Cat. #2126.84 Both models include a 9V battery and a user manual. 1.4.1 Accessories and Replacement Parts Adapter - BNC (female) / 4mm Banana (male)... Cat. #2119.94 Order Accessories and Replacement Parts Directly Online Check our Storefront at www.aemc.com/store for availability 4 MiniFlex Flexible AC Current Probe

CHAPTER 2 PRODUCT FEATURES 2.1 Description The MiniFlex HF is a compact flexible AC current transformer composed of a flexible sensor and an electronic module. It is designed to measure from 5Hz to 1MHz. The flexible sensor permits measurements on conductors where standard clamp-on probes could not be used. In particular, it can be installed in confined spaces, places where access is difficult, or even wrapped around irregular shapes. The MiniFlex HF is lightweight. It does not use magnetic cores like standard transformers. The transformation principle is based on an air core. It presents virtually no load to the system under test, has a low phase shift and excellent frequency response from 5Hz to 1MHz at -3db, and cannot be damaged by overloads. The sensor assembly is insulated for 1000V CAT III; 600V CAT IV. The MiniFlex HF meets EN 61010 and is CE marked. The MiniFlex HF has an mv output proportional to the current measured for direct readings on oscilloscopes, DMMs, data loggers and power or harmonic meters. TRMS measurements are taken when connected to a TRMS meter. The MiniFlex HF is insensitive to DC currents and only the AC component of the measured signal is measured. The flexible sensor is available in lengths of 6" and 10". MiniFlex Flexible AC Current Probe 5

2.2 Features Measures from 0.5Arms to 300Arms Accuracy 1% of Reading ± 0.3A TRMS measurements when connected to a TRMS instrument No core saturation or damage if overloaded 9V battery for typical 140 hour continuous operation 1MHz frequency response Low phase shift for power measurements Insensitive to DC, measures only AC component on DC + AC signals Excellent linearity Lightweight Sensor is resistant to oils and aliphatic hydrocarbons EN 61010; 1000V CAT III; 600V CAT IV; CE Mark 6 MiniFlex Flexible AC Current Probe

2.3 Control Features 1 4 2 5 6 7 3 Figure 1 1. Flexible sensor 5mm Ø 2. Sensor opening device 3. Shielded cord 4. BNC output connector 5. Green ON/OFF indicator 6. Range selection switch: - Model MF 300-6-2-10-HF (30 / 300A) - Model MF 300-10-2-10-HF (300 / 300A) 7. Optional BNC (female) / Banana (male) connector MiniFlex Flexible AC Current Probe 7

CHAPTER 3 SPECIFICATIONS REFERENCE CONDITIONS Quantity of influence Temperature Relative humidity Frequency of the signal measured Type of signal External electric field External DC magnetic field (earth field) External AC magnetic field Position of the conductor Shape of the measurement coil Input impedance of the display device connected to housing Reference values 23 ± 5 C 20 to 75% RH 40 to 400Hz Sinusoidal < 1V/m < 40A/m None Centered in the measurement coil Nearly circular 1MW MODEL MF 300-6-2-10-HF MF 300-10-2-10-HF ELECTRICAL Range 30/300A Signal Output 100mV/10mV/A Frequency Range 5Hz to 1MHz @ -3db Frequency Limitation none Influence Of Conductor Positioning 1.5% typical, 3% max Influence Of Conductor Positioning In Sensor Against Handle 4% typical, 6% max External Conductor Influence 35dB to 40dB on contact Accuracy ± 1% +0.3A Common Mode Rejection 100dB typical, 80dB min Max peak factor (1) at I nominal 1.5 Residual noise at I = 0 (Arms) (2) 0.3A Max phase shift at 1kHz ( ) 1 Max offset voltage (mvdc) 50 5 Max output voltage (Vpeak) ± 4.5 Output impedance (kw) 1 Power Source 9V alkaline battery (6LF22) Battery Life 140 hrs continuous operation or 10,000 one minute measurements Battery Indicator When Green LED starts blinking, remaining life is approx 8 hours; When LED is OFF, the battery needs to be replaced (1): Peak factor PF = Vpeak/Vrms (2): The residual noise affects the measurement uncertainty according to the formula: (I measured x 0.01) 2 + (residual noise) 2 global uncertainty = (I measured 0) I measured If the current measured is zero, the uncertainty is equal to the residual noise. 8 MiniFlex Flexible AC Current Probe

MODEL MF 300-6-2-10-HF / MF 300-10-2-10-HF MECHANICAL Module Output Coaxial cable terminated by an insulated female BNC connector Module Dimensions 4.0 x 2.5 x 1.1" (103 x 64 x 28mm) Module Weight 7 oz (200g) Sensor Diameter 5mm Ø Sensor Length 6" (152mm) 10" (250mm) Max Conductor Size 1.77" (45mm) 2.95" (70mm) Connection Cable Length 6.5 ft (2m) Flammability Rating Sensor: UL94V0 Housing: UL94V2 Drop Test Per IEC 68-2-32 Vibration Per IEC 68-2-6 Mechanical Shock Per IEC 68-2-27 Weatherproofing IP 50 ENVIRONMENTAL Operating Temperature Range 14 to 131 F (-10 to +55 C) Storage Temperature Range -40 to 158 F (-40 to +70 C) Influence of Temperature Sensor: -10 to 100 C: < 0.5% of Reading per 10 C Module: -10 to 55 C: < 0.5% of Reading per 10 C Relative Humidity 10 to 90% RH: 0.1% typical, 0.3% max Altitude Operating: 0 to 2000m, working voltage derating above; Non-operating: 0 to 12,000m SAFETY Double Insulation Yes, per IEC 1010-2-32 CE Rated Yes Safety Rating EN 61010, 1000V CAT III; 600V CAT IV Pollution Level 2 Immunity and Emission Industrial environment Electromagnetic Compatibility Satisfies the EMC and LVD directives required for CE marking and product standard IEC 61326-1 (Ed. 97) + A1 (Ed. 98) Specifications are subject to change without notice MiniFlex Flexible AC Current Probe 9

3.1 Typical Response Curves 3.1.1 Frequency Error: Model MF 300-6-2-10-HF Diameter 45mm Model MF 300-10-2-10-HF Diameter 70mm 30A Range: 30 % 20 % 10 % 0 % -10 % 1 Hz 10 Hz 100 Hz 1000 Hz 10000 Hz 100000 Hz 300A Range: 30 % 20 % 10 % 0 % -10 % 1Hz 10 Hz 100 Hz 1000Hz 10000Hz 100000 Hz 10 MiniFlex Flexible AC Current Probe

3.1.2 Amplitude Error - Diameter 45mm MiniFlex Flexible AC Current Probe 11

CHAPTER 4 OPERATION 4.1 Compatibility The MiniFlex is compatible with any Oscilloscope, AC voltmeter, or other voltage measuring instrument with an input impedance greater than 1MΩ. To achieve the best overall accuracy, use the MiniFlex with an Oscilloscope set to AC mode with an accuracy of 0.75% or better 4.2 Tips for Making Precise Measurements When using the MiniFlex with an Oscilloscope, it is important to select the range that provides the best resolution. Failure to do this may result in measurement errors. For best results, select the highest MiniFlex output signal possible and the most sensitive meter range for this output. Make sure the Oscilloscope or measuring instrument can accurately measure mvac. For best accuracy, center the MiniFlex around the conductor to be measured. The overall measurement accuracy is the sum of the MiniFlex accuracy and the displaying instrument accuracy. 12 MiniFlex Flexible AC Current Probe

4.3 Making Measurements Connect the electronic module to the AC Volt range of a Oscilloscope input or measuring instrument. Select the highest range on the Mini- Flex. Press the sensor s yellow opening device to open the flexible coil. Wrap the coil around the conductor to be tested. If possible, within range, select the lowest range to obtain the best resolution. Do not exceed specified current range for the output. Read the displayed value on the Oscilloscope and divide it by the range selected (i.e. if reading = 2.59V with the 10mV/A output range, the current flowing through the probe is 2590mV 10 = 259A). For best accuracy, carefully center the conductor inside the flexible core, and if possible, avoid being in the proximity of other conductors which may create noise and interference (particularly near the latch). MiniFlex Flexible AC Current Probe 13

CHAPTER 5 MAINTENANCE 5.1 Maintenance Warning For maintenance use only specified replacement parts. To avoid electrical shock, do not attempt to perform any servicing unless you are qualified to do so. To avoid electrical shock and/or damage to the instrument, do not get water or other foreign agents into the case. Turn the instrument OFF and disconnect the unit from all the circuits before opening the case. 5.1.1 Battery Replacement The battery must be replaced when the green indicator flashes or remains off when the instrument is switched on. Disconnect everything connected to the instrument and set the switch to OFF. Use a screwdriver to unscrew the two screws on the housing. Replace the old battery with a new one (9V alkaline or lithium battery of type 6LF22). Close the housing, making sure that it is completely and correctly closed, then screw both screws back in. 5.1.2 Cleaning It is important to keep the sensor latch mating surfaces clean to prevent foreign matter from entering the closing. The sensor may be gently cleaned with a soft cloth, soap and water. Dry immediately after cleaning. Avoid water penetration into the electronic module. Make sure the sensor, electronic module, and all leads are completely dry before any further use. 14 MiniFlex Flexible AC Current Probe

Repair and Calibration To ensure that your instrument meets factory specifications, we recommend that it be scheduled back to our factory Service Center at one-year intervals for recalibration, or as required by other standards or internal procedures. For instrument repair and calibration: You must contact our Service Center for a Customer Service Authorization Number (CSA#). This will ensure that when your instrument arrives, it will be tracked and processed promptly. Please write the CSA# on the outside of the shipping container. If the instrument is returned for calibration, we need to know if you want a standard calibration, or a calibration traceable to N.I.S.T. (Includes calibration certificate plus recorded calibration data). Ship To: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA Phone: (800) 945-2362 (Ext. 360) (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 E-mail: repair@aemc.com (Or contact your authorized distributor) Costs for repair, standard calibration, and calibration traceable to N.I.S.T. are available. NOTE: You must obtain a CSA# before returning any instrument. Technical and Sales Assistance If you are experiencing any technical problems, or require any assistance with the proper operation or application of your instrument, please call, mail, fax or e-mail our technical support team: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 200 Foxborough Boulevard Foxborough, MA 02035 USA Phone: (800) 343-1391 (508) 698-2115 Fax: (508) 698-2118 E-mail: techsupport@aemc.com www.aemc.com NOTE: Do not ship Instruments to our Foxborough, MA address. MiniFlex Flexible AC Current Probe 15

Limited Warranty The MiniFlex is warranted to the owner for a period of two years from the date of original purchase against defects in manufacture. This limited warranty is given by AEMC Instruments, not by the distributor from whom it was purchased. This warranty is void if the unit has been tampered with, abused or if the defect is related to service not performed by AEMC Instruments. Full warranty coverage and product registration is available on our website at www.aemc.com/warranty.html. Please print the online Warranty Coverage Information for your records. What AEMC Instruments will do: If a malfunction occurs within the warranty period, you may return the instrument to us for repair, provided we have your warranty registration information on file or a proof of purchase. AEMC Instruments will, at its option, repair or replace the faulty material. REGISTER ONLINE AT: www.aemc.com Warranty Repairs What you must do to return an Instrument for Warranty Repair: First, request a Customer Service Authorization Number (CSA#) by phone or by fax from our Service Department (see address below), then return the instrument along with the signed CSA Form. Please write the CSA# on the outside of the shipping container. Return the instrument, postage or shipment pre-paid to: Ship To: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA Phone: (800) 945-2362 (Ext. 360) (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 or (603) 749-6309 E-mail: repair@aemc.com Caution: To protect yourself against in-transit loss, we recommend you insure your returned material. NOTE: You must obtain a CSA# before returning any instrument.

05/17 99-MAN 100349 v8 Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA Phone: (603) 749-6434 Fax: (603) 742-2346 www.aemc.com