Catalog Number: Approvals: ASW - 32 - - NW - - - - EBB - Series # of LEDs Overall Dimensions Driver LED Color Distribution Voltage Mounting Options Finish Accessories Emergency battery Backup (EBB) Details Date: Page 1 of 9 ASW-32G1 with EBB Option Dimensions (Large housing) Top View Emergency Battery Backup 120-277V only. Emergency LED Array 15.6 15.6 39.6 cm 39.6 cm 15.0 15.0 38.1 cm 38.1 cm 15.6 39.6 cm 15.0 38.1 cm 3.5 8.9 cm Side View End View 16.5 16.5 41.8 cm 4.0 41.8 cm 4.0 10.1 cm 10.1 cm 5.7 5.7 14.6 5.7 cm 14.6 cm 14.6 cm 3.5 8.9 cm 16.5 41.8 cm 4.0 10.1 cm 5.7 14.6 cm Red Charging Indicator Weight: 16.8 lbs 7.6 kgs Test Button Specifications Rated System Life (LED life per ) Driver and LED life are rated up to 80,000 hrs @ 35 C (95 F). Construction Die-cast aluminum housing with corrosion resistant hardware. Optic chamber and separate driver housing constructed to IP66. Die-cast aluminum heatsink allows for long life of LEDs up to 35 C ambient. Thermal Management IP66 rated thermal management system creates a vortex of airflow with passthrough convective cooling system and heat extraction. LED and Board Array Small housing: 32 Rebel ES LEDs. Color temperature: Neutral White 4000 K +/- 250 K. CRI 60.Metal core printed circuit board. RoHS compliant. Driver High efficiency multi-volt driver (50 or 60 Hz), maintains constant current flow to LEDs to accommodate LED variations. High power factor (>90% standard). Constant current: 350, 530 or 700 ma. Voltage: 120-277. Temperature range: 0 C (32 F) to to 35 C (95 F). Open/short circuit protection. RoHS compliant. Surge protector standard. The surge protector is in accordance with IEEE / ANSI C62.41.2 guidelines, with a surge current rating of 10,000 amps. LED Optical System LED Pod optical assemblies. Type II, III, IV or Wall Throw distribution. Fully gasketed Dust-Tite construction. Employs Philips LEDGINE technology and Rebel ES LEDs. Mounting Surface mount standard. Contractor friendly integral bubble mount for ease of installation. Contractor responsible for sealing housing to mounting surface. Emergency Battery backup The emergency LED backup system provides coderequired 1 footcandle minimum path-of-egress illumination, from the building up to 10 feet toward the common way. AeroScape s emergency backup system EBB option will operate for 90 minutes and extinguish itself once power is fully recovered. 120-277V only. EBB option is suitable for use in ambients from 0 to 35 C. No heating element is required. Finish Standard textured finish options available. TSA = textured satin aluminium, TDB = textured dark bronze, TBK = textured black, TWHT = textured white, TGR = textured gray, TPG = textured Philips gray, TGN = textured green, and RAL(*) = custom color (* = specify RAL #). Listings ETL/cETL listed to the UL 1598 standard, suitable for Wet Locations. Suitable for use in ambients from 0 to 35 C (32 to 95 F). EBB option is listed to UL924 standard and is suitable for use in ambients from 0 to 35 C (32 to 95 F). The quality systems of this facility have been registered by UL to the ISO 9001 series standards. Warranty Philips Gardco luminaires feature a 5 year limited warranty. Philips Gardco LED luminaires with LED arrays feature a 5 year limited warranty covering the LED arrays and LED drivers. Motion sensors are covered by warranty for 5 years by the motion sensor manufacturer.
Page 2 of 9 AeroScape Wall Mount ASW-32G1 with EBB Series # of LEDs Driver LED Color Distribution Voltage Mounting Options Finish ü ü ü ASW 32G1 350 NW 2L Type II 120 SM F1 2 Single Fusing (120, 277V) Neutral Surface 530 White 3L Type III 208 Mount (standard) 700 4L Type IV 240 F2 2 Double Fusing WT Wall Throw 277 (208, 240V) UNV 1 PCB 2 Photocontrol Button TSA TDB TBK Textured Satin Aluminum Textured Dark Bronze Textured Black TWHT Textured White SG Stone Guard TGR Textured Gray Notes: 1) UNV universal voltage, 120-277V. 2) Specify voltage. Fusing and photocontrols not available with UNV voltage option. 3) Luminaire efficiency will decrease from 0 to 10% depending on the spread of the optics. 4) 0-10V leads exiting luminaire supplied for connection to external secondary controls (by others). DL 3 Diffuse Lens TGN Textured Green ü EBB DD 4 Emergency Battery Backup (standard) Dimming Driver TPG Textured Philips Gray RAL(*) Custom Color (*specify RAL #) Accessories (must be ordered separately) Distribution Patterns Egress Distribuiton F1-KIT 2 F2-KIT 2 Single Fusing Field Installed Kit (120, 277V) Double Fusing Field Installed Kit (208, 240V) Type II (2L) Type III (3L) Illustration demonstrates fixture at egress lighting mode. Type IV (4L) Wall Throw (WT)
Page 3 of 9 Option Details F1 Single Fusing (120, 277V) F2 Double Fusing (208, 240V) DL Diffuse Lens Reduces glare from direct view of optics. Luminaire efficiency will decrease from 0 to 10% depending on the spread of the optics. PCB Factory Installed Photocell Button Not available with 480 V. EBB Emergency Battery Backup (standard) 120-277V only. See EBB details on page 4. Note: Voltage must be specified with fusing and photocell options. SG Stone Guard (included, field installed) DD Dimming Driver (0-10V) Continuous dimming down to 10% power. 0-10V leads exiting luminaire supplied for connection to external controls (by others). Accessory Details F1-KIT Single Fusing Field Installed Kit (120, 277, 347V) F2-KIT Double Fusing Field Installed Kit (208, 240, 480V) Standard Wall Mount Details Wall Mount Drill Template 3.375 Bubble Level 4.39 11.15 cm 5.7 14.6 cm 3.375 Ø2.750 Ø 3.50 15.6 39.6 cm 5.13 13.03 cm 3.375
Page 4 of 9 Technical Data - ASW-32G1 @ 350 ma Total System Watts 35 Initial Lumens @ 25 C Ambient 2,923 Lumens per Watt @ 25 C Ambient 85 Initial Lumens @ 35 C Ambient 2,848 Lumens per Watt @ 35 C Ambient 81 ASW-32G1 LED (350 ma Driver) Type III ( 3L ), 4000 K +/- 250 K CCT Measured Junction Temperatures (Tj) ASW-32G1 LED Unit (350 ma) 70 60 Tj - 51 C Tj - 60 C (25 C ambient) (35 C ambient) Maximum Tj Limit 127 C LIFETIME (1000 HRS) 50 40 30 20 10 60% Below Thermal Limit 53% Below Thermal Limit Rebel ES lifetime curve 40 50 60 70 80 90 100 110 120 130 140 150 160 JUNCTION TEMPERATURE ( C) Green shaded portion represents junction temperatures below LED manufacturer s recommended limit to ensure a minimum of 60,000 hours of rated life. Life Expectancy Table Above the minimum 60,000 Rated LED Life at Multiple Ambient Temperatures ASW-32G1 Unit (350 ma, ) Note: LED rated life per the curve above is 60,000 hrs. The tables below showing predicted LED life expectency are based on ASW s superior thermal management, actual junction temperature (Tj) and projected curves. The projected life in years may be extended even further if used with dimming options. Average Outdoor Ambient Temp Junction Temp (Tj) ASW-32G1 (350 ma) (Hrs) Efficacy (Lumens / Watt) @ 10 Hrs/Day (Yrs) 0 C / 32 F 26 198,100 88 54 10 C / 50 F 36 182,500 87 50 25 C / 77 F 51 165,779 85 45 30 C / 86 F 56 159,589 83 44 35 C / 95 F 60 152,300 81 42
Page 5 of 9 Technical Data - ASW-32G1 @ 530 ma ASW-32G1 LED (530 ma Driver) Type III ( 3L ), 4000 K +/- 250 K CCT Total System Watts 51 Initial Lumens @ 25 C Ambient 4,068 Lumens per Watt @ 25 C Ambient 81 Initial Lumens @ 35 C Ambient 3,962 Lumens per Watt @ 35 C Ambient 78 Measured Junction Temperatures (Tj) ASW-32G1 LED Unit (530 ma) 70 60 Tj - 63 C Tj - 73 C (25 C ambient) (35 C ambient) Maximum Tj Limit 127 C LIFETIME (1000 HRS) 50 40 30 20 10 50% Below Thermal Limit 43% Below Thermal Limit Rebel ES lifetime curve 40 50 60 70 80 90 100 110 120 130 140 150 160 JUNCTION TEMPERATURE ( C) Green shaded portion represents junction temperatures below LED manufacturer s recommended limit to ensure a minimum of 60,000 hours of rated life. Life Expectancy Table Above the minimum 60,000 Rated LED Life at Multiple Ambient Temperatures ASW-32G1 Unit (530 ma, ) Note: LED rated life per the curve above is 60,000 hrs. The tables below showing predicted LED life expectency are based on ASW s superior thermal management, actual junction temperature (Tj) and projected curves. The projected life in years may be extended even further if used with dimming options. Average Outdoor Ambient Temp Junction Temp (Tj) ASW-32G1 (530 ma) (Hrs) Efficacy (Lumens / Watt) @ 10 Hrs/Day (Yrs) 0 C / 32 F 38 172,339 84 47 10 C / 50 F 48 160,346 82 44 25 C / 77 F 63 144,200 81 40 30 C / 86 F 68 136,500 79 37 35 C / 95 F 73 131,845 78 36
Page 6 of 9 Technical Data - ASW-32G1 @ 700 ma ASW-32G1 LED (700 ma Driver) Type III ( 3L ), 4000 K +/- 250 K CCT Total System Watts 72 Initial Lumens @ 25 C Ambient 5,113 Lumens per Watt @ 25 C Ambient 71 Initial Lumens @ 35 C Ambient 4,940 Lumens per Watt @ 35 C Ambient 69 Measured Junction Temperatures (Tj) ASW-32G1 LED Unit (700 ma) 70 60 Tj - 77 C Tj - 87 C (25 C ambient) (35 C ambient) Maximum Tj Limit 127 C LIFETIME (1000 HRS) 50 40 30 20 10 39% Below Thermal Limit 31% Below Thermal Limit Rebel ES lifetime curve 40 50 60 70 80 90 100 110 120 130 140 150 160 JUNCTION TEMPERATURE ( C) Green shaded portion represents junction temperatures below LED manufacturer s recommended limit to ensure a minimum of 60,000 hours of rated life. Life Expectancy Table Above the minimum 60,000 Rated LED Life at Multiple Ambient Temperatures ASW-32G1 Unit (700 ma, ) Note: LED rated life per the curve above is 60,000 hrs. The tables below showing predicted LED life expectency are based on ASW s superior thermal management, actual junction temperature (Tj) and projected curves. The projected life in years may be extended even further if used with dimming options. Average Outdoor Ambient Temp Junction Temp (Tj) ASW-32G1 (700 ma) (Hrs) Efficacy (Lumens / Watt) @ 10 Hrs/Day (Yrs) 0 C / 32 F 52 146,417 74 40 10 C / 50 F 62 135,637 72 37 25 C / 77 F 77 120,048 71 33 30 C / 86 F 82 115,007 70 32 35 C / 95 F 87 110,044 69 30
Page 7 of 9 Photometric Data - ASW-32G1 Cat No. Optic (distribution) System Wattage Lumens Efficacy B (backlight) U (uplight) G (glare) CCT IES File # ASW-32G1-350 Type II (2L)* 39 2,772 72 1 0 1 4000 K +/- 250 K ASW-32G1-350-2L.IES Type III (3L) 35 2,923 85 1 0 1 4000 K +/- 250 K ASW-32G1-350-3L.IES Type IV (4L) 35 2,790 81 1 0 1 4000 K +/- 250 K ASW-32G1-350-4L.IES Wide Throw (WT) (Type II) 35 3,073 89 2 0 0 4000 K +/- 250 K ASW-32G1-350-WT.IES ASW-32G1-530 Type II (2L) 51 3,769 75 1 0 1 4000 K +/- 250 K ASW-32G1-530-2L.IES Type III (3L) 51 4,068 81 1 0 1 4000 K +/- 250 K ASW-32G1-530-3L.IES Type IV (4L) 51 3,883 77 1 0 1 4000 K +/- 250 K ASW-32G1-530-4L.IES Wide Throw (WT) (Type II) 51 4,276 85 2 0 0 4000 K +/- 250 K ASW-32G1-530-WT.IES ASW-32G1-700 Type II (2L)* 79 4,797 60 1 0 1 4000 K +/- 250 K ASW-32G1-700-2L.IES Type III (3L) 71 5,113 72 2 0 1 4000 K +/- 250 K ASW-32G1-700-3L.IES Type IV (4L) 71 4,881 69 1 0 1 4000 K +/- 250 K ASW-32G1-700-4L.IES Wide Throw (WT) (Type II) 71 5,375 76 2 0 1 4000 K +/- 250 K ASW-32G1-700-WT.IES * LM-79 test report data was generated by a 3rd party independent lab - Luminaire Testing Laboratory (LTL). Backlight Uplight Glare - refers to light directed opposite the target area, which may create light tresspass. Backlight is commonly behind the luminaire. - is illumination directed above the horizontal plane of the luminaire (90 ) which causes artificial sky glow. - is the amount of light from the luminaire emitted in directions or at angles that cause glare, which can be annoying or visually disabling.
Page 8 of 9 LED Lumen Maintenance Data - ASW-32G1 ASW-32G1 @ 350 ma ASW-32G1 @ 530 ma ASW-32G1 @ 700 ma Outdoor Ambient Temp ( C) 1 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40 Junction Temperature 2 30.8 35.8 40.8 45.8 50.8 55.8 60.8-42.8 47.8 52.8 57.8 62.8 67.8 72.8-57.2 62.2 67.2 72.2 77.2 82.2 87.2 - Thermal Factor 3 1.04 1.03 1.02 1.01 1.00 0.99 0.98-1.04 1.03 1.02 1.01 1.00 0.99 0.98-1.04 1.03 1.02 1.01 1.00 0.99 0.98-0 1.04 1.03 1.02 1.01 1.00 0.99 0.98-1.04 1.03 1.02 1.01 1.00 0.99 0.98-1.04 1.03 1.02 1.01 1.00 0.99 0.98-8,000 / 2.2 1.04 1.03 1.02 1.01 1.00 0.99 0.97-1.04 1.02 1.01 1.00 0.99 0.98 0.97-1.03 1.02 1.01 1.00 0.99 0.98 0.97-16,000 / 4.4 1.03 1.02 1.01 1.00 0.99 0.98 0.97-1.03 1.02 1.01 0.99 0.98 0.97 0.96-1.02 1.01 1.00 0.99 0.98 0.96 0.95-24,000 / 6.6 1.02 1.01 1.00 0.99 0.98 0.97 0.96-1.02 1.01 1.00 0.98 0.97 0.96 0.95-1.01 1.00 0.99 0.97 0.96 0.95 0.93-32,000 / 8.8 1.02 1.00 0.99 0.98 0.97 0.96 0.95-1.01 1.00 0.99 0.97 0.96 0.95 0.94-1.00 0.99 0.97 0.96 0.95 0.93 0.91-40,000 / 11.0 1.01 1.00 0.99 0.97 0.96 0.95 0.94-1.00 0.99 0.98 0.96 0.95 0.94 0.92-0.99 0.98 0.96 0.95 0.93 0.91 0.90 - Life Hours of operation / Years based on 10 hrs/day burn cycle 48,000 / 13.2 1.00 0.99 0.98 0.97 0.95 0.94 0.93-0.99 0.98 0.97 0.95 0.94 0.93 0.91-0.98 0.96 0.95 0.93 0.92 0.90 0.88-56,000 / 15.3 1.00 0.98 0.97 0.96 0.95 0.93 0.92-0.98 0.97 0.96 0.94 0.93 0.92 0.90-0.97 0.95 0.94 0.92 0.90 0.88 0.85-64,000 / 17.5 0.99 0.98 0.96 0.95 0.94 0.92 0.91-0.98 0.96 0.95 0.93 0.92 0.90 0.89-0.96 0.94 0.92 0.90 0.88 0.86 0.83-72,000 / 19.7 0.98 0.97 0.96 0.94 0.93 0.92 0.90-0.97 0.95 0.94 0.92 0.91 0.89 0.87-0.94 0.93 0.91 0.88 0.86 0.83 0.81-80,000 / 21.9 0.97 0.96 0.95 0.93 0.92 0.91 0.89-0.96 0.94 0.94 0.91 0.90 0.87 0.85-0.93 0.91 0.88 0.86 0.83 0.81 0.78-88,000 / 24.1 0.97 0.95 0.94 0.93 0.91 0.90 0.88-0.95 0.94 0.92 0.90 0.88 0.85 0.83-0.91 0.89 0.86 0.84 0.81 0.79 0.76-96,000 / 26.3 0.96 0.95 0.93 0.92 0.90 0.89 0.86-0.94 0.93 0.90 0.88 0.86 0.83 0.81-0.89 0.86 0.84 0.81 0.79 0.76 0.74-104,000 / 28.5 0.95 0.94 0.93 0.91 0.89 0.87 0.85-0.93 0.91 0.89 0.86 0.84 0.81 0.79-0.87 0.84 0.82 0.79 0.76 0.73 0.71-112,000 / 30.7 0.95 0.93 0.92 0.90 0.87 0.85 0.83-0.91 0.89 0.87 0.84 0.82 0.79 0.76-0.84 0.82 0.78 0.75 0.73 0.71 0.69-120,000 / 32.9 0.94 0.92 0.90 0.88 0.86 0.83 0.81-0.89 0.87 0.85 0.82 0.80 0.76 0.74-0.81 0.78 0.75 0.72 0.70 0.68 - - 128,000 / 35.1 0.93 0.91 0.89 0.86 0.84 0.82 0.79-0.87 0.85 0.83 0.80 0.76 0.73 0.71-0.77 0.74 0.71 0.69 - - - - 136,000 / 37.3 0.91 0.89 0.87 0.85 0.82 0.80 0.77-0.86 0.83 0.80 0.76 0.73 0.70 0.68-0.73 0.70 0.68 - - - - - 144,000 / 39.5 0.90 0.87 0.85 0.83 0.81 0.77 0.74-0.84 0.80 0.76 0.72 0.70 - - - 0.68 - - - - - - - 152,000 / 41.6 0.88 0.86 0.84 0.82 0.77 0.74 0.70-0.79 0.74 0.71 0.68 - - - - - - - - - - - - 160,000 / 43.8 0.86 0.84 0.82 0.77 0.73 0.70 - - 0.73 0.69 0.67 - - - - - - - - - - - - - 168,000 / 46.0 0.85 0.82 0.77 0.72 0.69 - - - 0.67 - - - - - - - - - - - - - - - 176,000 / 48.2 0.83 0.75 0.71 0.67 - - - - - - - - - - - - - - - - - - - - 184,000 / 50.4 0.73 0.68 0.65 - - - - - - - - - - - - - - - - - - - - - 192,000 / 52.6 0.63 - - - - - - - - - - - - - - - - - - - - - - - Notes: 1. Outdoor ambient temperature is based on annual average operating air temperature as seen by the fixture within its environmental conditions. 2. Junction temperature is calculated from in-situ, solder point measurement per LED manufacturers recommendation, and will vary based on drive current and nominal forward voltage of the LED. 3. Thermal factor is a prorate or derate value based on the in-situ solder point measurement and the relative luminous flux provided by the LED manufacturer. 4. LED Lumen Maintenance Data chart is actual lumen adjustment per the operating ambient. No additional prorate or derate required.
Page 9 of 9 Notes: Pb lead-free RoHS 2002/95/EC Philips Lighting Company 200 Franklin Square Drive Somerset, NJ 08873 Phone: 855-486-2216 Philips Lighting Company 281 Hillmount Road Markham ON, Canada L6C 2S3 Phone: 800-668-9008