Eltek TU GenII GD900A Energy monitor (multidrop NDRail350) transmitter user instructions

Similar documents
Eltek TU User Instructions for RP250GD and RP250GDS repeater

GENII RADIO DATA LOGGING SYSTEMS

Energy Management Energy Meter Type EM21 72R Retro-Fit

Installation and Operating Instructions. Power IT Power Factor Controller RVC

Energy Meters for DIN Rail Mounting Electric energy meter WS0101, WS0102,WS1102 WS0301, WS0302,WS1302

Table Of Contents Overview of the operating buttons... 4 The functions of the datalogger... 5 How to start logging from the default settings...

HAWK5000 Operators Manual

User s Manual. F2 Calculator. A metering component for thermal energy applications

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

The wireless alternative to expensive cabling...

Energy Management Energy Meter Type EM340

The wireless alternative to expensive cabling...

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

Modular Radio Telemetry System

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

Modular Radio Telemetry System

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Connecting Mains Electrical Power

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

The wireless alternative to expensive cabling...

DPF-MAC Auto power factor controller

Wireless Room Temperature and Humidity Transmitter (Units without Temperature Setpoint or Override) Installation and Operating Instructions

The wireless alternative to expensive cabling...

RSMFX-2R MULTIFUNCTIONAL

200, 201 Series Radio Telemetry Transmitters

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

+GF+ SIGNET Temperature Transmitter Instructions

Hub and Cluster. ogramming Manual. Pro MAN3090

METERSUK. SmartLink D Y N A M i T E. EM415 MOD Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION. Single Phase Metering

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

Programming Manual (V3 Software)

Energy Management Energy Meter GM3T E GM3T-RS485 E

Operating Guide October 2006

Energy Management Energy Meter Type EM111

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

Energy Management Energy Meter Type EM112

SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual

Printing Humidity/Temperature Meter

USERS MANUAL TR-710.

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATION GUIDE

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

SonoMeter 31 Energy Meters

MID. Energy Management Energy Meter Type EM23 DIN. Product Description. Type Selection. How to order EM23 DIN AV9 3 X O1 PF A EM23 DIN

Blue Point Engineering

FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15108 (No Case version)

WIRELESS Energy Monitor - Smart Meter

Introduction Pag. 1. Function and location of the controls Pag. 2. Installation Pag. 3. Power supply Pag. 3. Installing an antenna Pag.

Midland 248XL I NSTRUCTION GUI DE

3-phase meter with direct connection and pulse or Modbus RS485 output

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Langton House, 19 Village Street, Harvington, Worcestershire. WR11 8NQ Tel: Fax: RTB5211 UHF FULL DUPLEX BASE STATION

Sound Engineering Solutions

Remote Radio Control. WAVE Push button radio control systems

SUPPLY NETWORK ANALYZER CVM-96 SERIES

METERSUK. SmartLink D Y N A M i T E. EM735 S Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15101, FMT15102, FMT15104, FMT15108 (No Case version)

Energy Management Energy Meter Type EM110

Energy Management Three-phase energy meter with output modules Type EM4-DIN

MID. Energy Management Energy Analyzer Type EM11 DIN. Product Description. How to order EM11 DIN AV8 1 X O1 PF. Type Selection EM11 DIN

Energy Management Energy Analyzer Type EM111

WARRANTY. Long Range Systems, LLC, 20 Canal St, Suite 4N, Franklin, NH 03235

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

EIB/KNX Switch Actuators. User manual

Energy Management Energy Analyzer Type EM112

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information

Energy Management Energy Meter Type EM110

WiMo Antennen und Elektronik GmbH Am Gäxwald 14, D Herxheim Tel. (07276) FAX 6978

NSD Safety Mat Controller Modules Both Modules are compliant to OSHA & ANSI Standards - EN ISO EN EN 81-1 EN NSD VDC

PRO Professional Radio Control Series Applications

IMPORTANT: THIS DEVICE MUST BE PROFESSIONALLY INSTALLED READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

PM-311x Quick Start Ver PM-311x introduction 1.1. Caution & Warning 1.2. Product Warranty & Customer Support

TYPE - K.J.E.T. PRINTING THERMOMETER. Model INSTRUCTION MANUAL

Ocean Controls KT-5221 Modbus IO Module

Energy Management Modular Power Analyzers Type WM2-96

Z-10-D-IN. RS485 Modbus Module 10 Digital Inputs

AMIK 200 / 201 Technical Data Sheet

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

PM 305 Operating Guide

Modular Metering System ModbusTCP Communications Manual

INTEGRATED VOICE EVACUATION SYSTEM VM-3000 Series

RF Remote Control Unit SEAV

Meriam Model M ma Loop Calibrator Operating Instructions

POWER ANALYZER OPERATION MANUAL. Model : DW-6090A

7006 Loop Mate 1 Loop / Voltage / Current Simulator

Energy Management Energy Meter with plug-in Output Modules Type EM4-DIN

PRELIMINARY DATA SHEET RI-D140. Three Phase Multifunction DIN Rail Energy Meter (MID Certified) MID

Remote Radio Control. M880 WAVE2 C Transmitter Range. M880 for Low Integrity Stop Circuit Applications

ST600 TRANSMITTER OPERATING INSTRUCTIONS

Earth Leakage Monitoring System IsoBase IsoHub IsoOut

DMTME-96 2CSG133030R4022 M DMTME-I Operation and assembly instructions 2CSG163030R4022 M CSG445001D0202

PROCESS & TEMPERATURE CONTROLLERS

Astra-R Kit Wireless Alarm System Operation Manual

( F L O W I Z F A M I L Y )

RM24100D. Introduction. 1 Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

BLuAC5 Brushless Universal Servo Amplifier

REIMESCH KOMMUNIKATIONSSYSTEME GMBH ALPIN HF / 50MHz Linear Amplifier - USER MANUAL. v1.1

Sound Engineering Solutions

Transcription:

Eltek TU1043 - GenII GD900A Energy monitor (multidrop NDRail350) transmitter user instructions System configuration diagram GD900A NDRail350 AC supply 240V nominal RS485 AC AC AC For 1 x three phase load Maximum of 6 x ND350V can be used with 1 x GD900A Page 1 of 12

Introduction The GD900A is part of the Eltek GenII family of transmitters. The GD900A can be used with up to six parallel connected NDRail350 energy monitors and appropriate current transformers, providing comprehensive monitoring and patterns of use of multiple three phase supplies. The system is ideal for retro fit energy monitoring. The GD900A can be used alongside all other GenII transmitter types. (See Eltek brochure Telemetry Energy Monitoring on the Eltek website: www.eltekdataloggers.co.uk/literature.shtml) The system comprises: " GD900A transmitter, " Up to 6 NDRail350 monitors (1 x three phase load meter), " NDMeter CTs (up to 18 CTs can be used per GD900A) " DSP10-12 DIN rail mounting power supply to power the GD900A. All components can be supplied by Eltek. The GD900A has an input for 6 x NDRail350 energy monitors (Modbus RS485) Each NDRail350 has an input for 1 x three phase load: " 3 x CT (AC333mV) " 3 x AC230V nominal " 1 x AC230 nominal to power the unit Parameters measured per NDRail350 are 3 x voltage, 3 x current, 3 x power factor (cosø), kwh and kvarh. Page 2 of 12

GD900A channel assignment " Channels can be presented at the RX250AL together with those from any other GenII transmitter and can be reordered during TX Setup or when configuring the RX250AL. " Channels can only be renamed when configuring the RX250AL with Darca software. " The GD900A assumes the identity of up to 6 virtual transmitters, each of which represents a connected NDRail350. Each virtual transmitter has its own serial number. " The channels of a virtual transmitter are labelled A through L. " RX250AL channels are numbered 1 through 247. " A fully loaded GD900A with 6 x NDRail350s connected can occupy 72 channels of the RX250AL. Transmitter channels for an individual NDRail350 / virtual transmitter: Tx Channel Phase/Range Resolution Function in Darca A V1 0-500VAC 0.1 Voltage B V2 0-500VAC 0.1 Voltage C V3 0-500VAC 0.1 Voltage D I1 0-1000A 0.1 Current E I2 0-1000A 0.1 Current F I3 0-1000A 0.1 Current G P1 0-1 0.01 Power factor (PF) H P2 0-1 0.01 Power factor (PF) I P3 0-1 0.01 Power Factor (PF) J 65000 Pulse count kwh K 65000 Pulse count kvarh L Ext power to GD900A 1 State Page 3 of 12

Use of the GD900 with the RC250 The GD900 functions as up to 6 transmitters with consecutive serial numbers. The RC250 can only communicate with the first transmitter in the sequence. The first serial number can be altered using the TxSetup program. Thus, the RC250 can be configured to receive data from the 6 consecutive virtual transmitters by changing the first serial number using TxSetup and configuring the RC250 one transmitter at a time. For example, if the GD900 serial number is 22001, it also has T-22002, 22003, 22004, 22005 and 22006 internally. To configure the RC250 using the RXConfig software: " 1. First configure the RC250 with the GD900 set to serial number 22001 to program this serial number " 2. Change the GD900 to serial number 22002 using TxSetup " 3. Configure the RC250 using this serial number to program it " 4. Repeat steps 2 and 3 for serial numbers 22003, 22004, 22005 and 22006 " 5. Change the GD900 serial number back to 22001 CTs that can be used with the NDRail350 (all AC330mV output at range) Type Range Size mm Cable dia CT open CT closed SCL8-5 SCL16-50 SCL16-100 0-5A 0-50A 0-100A 43 x 37 x 32 51 x 45 x 27 51 x 45 x 27 8mm 16mm 16mm SCT19-150 0-150A 51 x 53 x17 19mm SCT32-400 0-400A 82.5 x 85 x 27 32mm SCT51-800 0-800A 121 x 127 x 32 51mm Other SCT19 models available: 5, 10, 15, 20, 30, 50, 70 and 100A - refer Eltek Other SCT32 models available: 70, 100, 150, 200, 250, 300, 400 and 600A - refer Eltek Other SCT51 models available: 600, 1000A - refer Eltek SCL can be operated at range x 1.21 continuously SCT can be operated at range x 1.31 continuously Important note: CTs have a moulded arrow impressed on the case, the CT must be mounted on the power cable so that the arrow points to the load! CT wiring : Black is positive, White is negative. Page 4 of 12

GD900A Links The transmitter contains a rechargeable battery to maintain the GD900A operational should the AC supply fail. For despatch the battery is disconnected (to prevent total discharge). To connect the battery when received, remove the two bottom cover retaining screws to reveal: Battery Battery Shipping; The red link is installed as shown.. To commission: Remove the red link and install as above Battery charging, recovery and endurance The PCB mounted 150mAh 6V NiMh battery is charged at approximately 4mA. A fully discharged battery requires 36 hours charge to reach 80% capacity. The TX is fully functional if the battery is discharged when external power is applied. A charged battery can provide 24 hours standby should the AC supply fail. Settings are not lost if the battery is fully discharged. The battery is PCB mounted. Should replacement be necessary, the transmitter must be returned to Eltek or our approved distributor. External power required is 12VDC regulated. The preferred power supply is the type DSP10-12. This DIN rail mounting power supply is provided with screw down connections for ease of installation. The max demand current from the external power supply is 50mA. Page 5 of 12

Indicators and concealed push switch The push switch is located behind a small access hole located at the rear of the transmitter. To activate the switch a small screwdriver or unfurled paper clip can be used. Red LED cadence due to activation of the concealed push switch: Function Activate switch for LED cadence LCD Tx disable 5 seconds 5 x fast flashes After 5 seconds displays OFF Tx enable (when configured) 5 seconds 1 continuous 5 sec flash After 5 seconds displays sensor information Test transmissions approximately every 5 sec for 2 minutes. 2 second Short flash at time of transmission No change Red LED due to GD900A being configured or not configured: GD900A condition LED Note LCD GD900A not configured Blink every 8 seconds Battery gauge displayed only GD900A configured Short flash at time of a transmission A transmission occurs at a random time within the set TX interval See Display below LCD The LCD includes a battery condition gauge active at all times: (Battery gauge will flash if battery discharge imminent). Only configured channels are displayed. The LCD scrolls through the configured channel values. If channels A-K are configured but the NDRail350 is not connected or communications have failed, the display will read OPEN. If channel L is configured, this display will read 0 if no external supply is connected or 1 if external 12VDC is connected. Note: If the GD900A is to be stored or will not be connected to a charging source for more than 48 hours, the GB90A should be disabled (put into hibernate mode, i.e. TX disable mode) to prevent total battery drain and possible loss of settings. Press the concealed push switch for 5 seconds. The LCD will now read OFF. Page 6 of 12

Connecting the GD900A, NDRail350, CTs and (TDK) DSP 10-12 power supply: 1M Red Black V- V+ Twist 10mm The GD900A is supplied with a 1M tail for connection to NDRail350 and (TDK) DSP10-12 power supply. E N L Preferred power supply is the DIN rail mount (TDK) DSP10-12 +12V GND T+ T- GND R+ R- GND 100 / 240VAC Orange Black Green NDRail350 Addr. #1 15 16 17 A B 0V NDRail350 Addr. #2 15 16 17 A B 0V etc. GD900A Top panel 1M DIN Rail mounting (width 105mm) Isolated serial comms AC For single & three phase operation, refer to NDRail350 operating manual/refer next page. 1 L 2 N 3 Vn 4 V1 5 V2 6 V3 CT1 CT2 CT3 7 I1+ 8 I1-9 I2+ 10 I2-11 I3+ 12 I3- Current inputs Note: Wire CT black to I1+ and white to I1- etc. Connect only CTs with the same range value! Page 7 of 12

NDRail350 connections Ensure fuses are wired in as shown! A suitable Din rail mounting fuse holder is type CSFL4U (for fuse 1A 5 x 20mm fuse, not included) and end plate type CSFLEPU. Refer to Eltek. 3-Phase 3 or 4 wire (*Optional Neutral) 3-Phase 3 wire (2 x CTs) Single Phase Where applicable V1(4), V2 (5), V3 (6) can be linked to L(1). A fuse must be used (see note above) from L supply to L(1) Page 8 of 12

Configuring the ND Rail 350 communications settings for use with the GD900A Each NDRail350 meter connected to the GD900A must be configured with the correct baud rate and meter address for the system to function correctly. The baud rate of each meter should be set to 19200 and the addresses of the connected meters should be set sequentially starting at 1. You can program the meters using the buttons on the front panel. To enter programming mode: Press and hold I and V together until the display shows Ct To change a setting value: P Press or until the required value is set. To move to the next setting: E Press I until the next page in the list is displayed. Parameters are set in the following order: Ct Un PLr PLt Pto Hr br Addr true Auto Storing current voltage pulse output rate pulse on time pulse test hours run baud rate meter address voltage input mode CT auto rotation mode store setup 5 50 100 150 400 800 The CT range can be selected from this list. All ranges are recorded with one decimal place resolution in the GD900A. set to 19200. set first meter s address to 1, second meter s address to 2, etc. To close programming, scroll to Storing and wait until the word Storing disappears. The display will revert back to the previous parameter. Page 9 of 12

GD900A configuration using Darca software Refer to the Quick start guide (ref TU1008) supplied with the RX250Al or download from http://www.eltekdataloggers.co.uk/literature.shtml. Connect the LCTX3 to the Comms socket: To access the Comms connector, remove the two screws securing the case bottom to reveal the Comms connector. (Note GD900A cannot be configured by the logger only). Comms connector As a precaution disconnect the external 12VDC power supply before inserting the LCTX3 jack into the comms socket. The external 12VDC can now be connected. When configuration is completed disconnect the external 12VDC power supply before removing the LCTX3 jack. If the unit is not intended for immediate use, park the battery link so as to disconnect the internal battery. (See GD900A links page 4) Launch Darca and open the Squirrel Channel to Transmitter Channel Assignments window. Before setting the Tx channels set the TX Interval: Page 10 of 12

GD900A method of operation Sampling the meters The GD900A reads and stores the values from the NDRail350 meter(s) every 10 seconds. It waits 1 second between reading each connected meter. 17 sets of values per meter are stored and a rolling average is kept. To check the system is operating correctly, you can verify that this is happening by watching the Cmd light on the front of the NDRail350 meters. Transmitting the data At each transmission the GD900A transmits the average of the 17 values for voltage, current and power factor. The actual transmission time of the virtual transmitters begins at a random point of time within the transmission interval. The virtual transmitters 1 through 6 (or as many are configured) will transmit in order, each transmission 1 second apart after the transmission time of the first virtual transmitter. The default TX interval is preset to 5 minutes but can be altered as required. A note about Virtual Transmitters For ease of use, The multiple ND Rail 350 meters connected to a GD900A transmitter will appear as a series of virtual transmitters in Darca (and are treated as such by the receiver/logger). Each virtual transmitter will have its own serial number. These virtual transmitter serial numbers run sequentially starting with the GD900A s serial number. For example: GD900A serial number: 20001 ND350 address 1: virtual transmitter serial number: 20001 ND350 address 2: virtual transmitter serial number: 20002 ND350 address 3: virtual transmitter serial number: 20003 ND350 address 4: virtual transmitter serial number: 20004...etc. After configuring the transmitter channels for the first NDRail350 in Darca s Squirrel Channel to Transmitter Channel Assignments window, you can move to the next connected meter in the list by clicking Next V Tx (Next virtual transmitter). The next meter can then be configured in the same way. To move back to the previous meter in the list, use << Prev V Tx (previous virtual transmitter). Configuring a virtual transmitter " For Tx channels A to L: select only the channel range from the drop down as shown in the screen shot and click on Set Channel. DO NOT ATTEMPT to use the Edit EU Range box. " Channels D, E and F are fixed 0-1000A; ensure the range type setting on the NDRail350 matches the range of the connected CT. See operating manual. " Channel L monitors connection of the external power supply: 0 = not connected and 1 = 12V connected. Darca Plus can use these values to set an alarm should the AC supply fail. Channel L is configurable per virtual transmitter. To avoid transmitting unnecessary data configure Channel L for the first virtual transmitter only. " Device Type should always be set to A20. Page 11 of 12

GD900A specification Frequency: Default is 434.225Mhz (other frequencies are available) Tx compliance: To EN300 220-1 Tx output power: 10mW ERP Useable Tx interval: typically 10 seconds to 15 minutes On air duration: approximately 400mS Environment: Indoor only, rated IP40 Temperature Range: -10 to +55ºC compliant to EN300 220-1, operational -30 to +60ºC Humidity: 95% non condensing Size: 85mm x 78mm x 42mm (excluding 75mm antenna) Weight: 250g Connection strip: 8 x miniature pitch rising cage connector (included) Antenna: Supplied compressed spring, L=75mm, Gain -3db Antenna connector: SMA Fixing: WBG wall fixing bracket (optional) Battery type: PCB mounted (6V) 0.17Ah Ni-mH Battery endurance: typically >24 hours if battery fully charged Charging time: typically 36 hours from discharged to 80% capacity Max lead length to ND Rail350V (screened twisted pair): <20M NDRail350 support information Brochure: http://www.ndmeter.co.uk/files/nd_350v_retro-fit_meter_brochure.pdf User manual: http://www.ndmeter.co.uk/files/nd_powerrail350_manual.pdf Installation manual: packed with product SCL CT brochure: http://www.ndmeter.co.uk/files/scl_retro-fit_current_sensors.pdf SCT CT brochure: http://www.ndmeter.co.uk/files/sct_retro-fit_current_sensors.pdf TU1043 03/11/15 Specialist Data Loggers Eltek Ltd, 35 Barton Road, Haslingfield Cambridge, CB23 1LL, England Tel: +44 (0) 1223 872111 Fax: +44 (0) 1223 872521 email: sales@eltekdataloggers.co.uk http://www.eltekdataloggers.co.uk Page 12 of 12