EMC TEST REPORT. NORTE SIRIUS ENTERPRISE CO., LTD , Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan

Similar documents
EMC TEST REPORT. Report No.: TS EME Model No.: 33XR-A Issued Date: Jan. 08, 2009

TEST REPORT... 1 CONTENT...

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 25. Page 2 of 25

EMC Testing Report. Dual-120CS. Yuan Hsun Electric Co., Ltd.

TEST SUMMARY. Prüfbericht - Nr.: Test Report No.: Seite 2 von 27. Page 2 of 27

EMC VERIFICATION SUMMARY Report No.: SZHH

ELECTRONICS TESTING CENTER(ETC), TAIWAN

Certificate of Test AND KEEPS ALL REQUIREMENTS ACCORDING THE FOLLOWING REGULATIONS IEC :2001 IEC :2007

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

EMC REPORT. ShenZhen KY Technology Co.,Ltd. No.369, BaoTian 1st RD, TieGang Industrial Park, Xixiang Town, Baoan District, ShenZhen, PRC.

BUREAU VERITAS. itaste svd

EMC Test Report. Report Number: M030826

EMC TEST REPORT. Report No. : EM/2004/10096 Page : 1 of 19

Harmonic Current emission EN :2014 Class A Pass. Voltage Fluctuation and Flicker EN :2013 Clause 5 Pass

EMC Test Report FATEK AUTOMATION CORP. FATEK. FBs-TBOX N/A

EN :2007+A1:2011 Electromagnetic compatibility Emission standard for residential, commercial and light-industrial environments

EMC REPORT DONGGUAN FIT-WATCH CO., LTD. 18#,Hedong No.1 road,jinsha village,changan town, Dongguan City, Guangdong Province.

Test Report. Guangdong East Power Co., Ltd. Fully Automatic AC Voltage Regulator. Brand Name:

Discontinuous Disturbance (Click) EN :2006+A1:2009+A2:2011 Clause N/A** Radiated Emission, 30MHz to 1000MHz

Test Report. Ningbo Goldmore Industrial Co.,Ltd.

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

Shenzhen Toby Technology Co., Ltd. EMC Test Report. Report No.: TB-EMC Page: 1 of 20

TEST REPORT. Report No. : EM/2008/80003 Page : 1 of 54

Prepared for Address. : KST DIGITAL TECHNOLOGY LIMITED : No.226, Pangu Street, Meixian, Meizhou, Guangdong. Prepared by

EMC TEST REPORT. For. Boardcon Technology Limited. MINI9G45 Computer on Module. Model No. : MINI9G45

EMC test report AU01+E04

EMC standards. Presented by: Karim Loukil & Kaïs Siala

EMC TEST REPORT. according to

ITUNER NETWORKS CORPORATION EMC REPORT Fremont Blvd. Fremont, CA

C E R T I F I C A T I O N

EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass. EN 55015: 2013 Clause Pass

EMC Test Report. Product. Model Number. Prepared for : Shenzhen top technology co., LTD Address : No 2.First Rd Of Lucky,Longgang Ping Shenzhen China

TEST REPORT. Power Spout PLT V. tested to the specification

EMC TEST REPORT. for. Coliy Technology Co.,Ltd. Fluxgate Gaussmeter

EN61326 EMC COMPLIANCE REPORT on the LP Series Ultrasonic Transmitter Remote Amplifier and Transducer for Hawk Measurement Systems Pty Ltd

TEST REPORT. draft draft draft. TRF Originator...: Shenzhen CTL Testing Technology Co., Ltd. Master TRF...: Dated

Page: 1 of 20 EMC TEST REPORT EN55024:1998+A2:2003

Declaration of Conformity.

EMC TEST REPORT For. Shenzhen Ruideou Keji Youxian Gongsi. Shenzhen Ruideou Keji Youxian Gongsi

CE EMC Test Certification

EN 55022: 2010+AC:2011 Clause 6.1 Pass. Harmonic Current EN :2006+A1:2009+A2:2009 Class A N/A

By order of ZHONGSHAN LIANGYI LIGHTING CO., LTD. at Zhongshan, China

EMC TEST REPORT. ADDRESS : #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.

EMC TEST REPORT for SHENZHEN MUST ENERGY TECHNOLOGY CO., LTD

EMC TEST REPORT for : DONGGUAN EVER DEVELOPMENT ELECTRONIC CO., Electronic calculator Model No.: KF15758

SUZHOU MAILI ELECTRICAL APPLIANCE CO., LTD NO.666,JIANLIN RD, XUGUAN SUBAREA, SUZHOU HIGH-TECH ZONE

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

C E R T I F I C A T I O N

Overview of EMC Regulations and Testing. Prof. Tzong-Lin Wu Department of Electrical Engineering National Taiwan University

1 SUMMARY OF STANDARDS AND RESULTS

Report for Excelsys EMC Measurements for 4Xgen Purchase Order: Project Number EMT07J026 Rev. B

EMC TEST REPORT For ShenZhen ZhangQing Electronic LTD poe tester Model No.: WS POE Tester/Detector Additional Model No: Please Refer to Page 8

EMC TEST REPORT For DONGHUA ELECTRIC STOCK CO., LTD. OF ZHEJIANG

EMC COMPLIANCE TEST REPORT

CE TEST CERTIFICATION

EMC Test report for LED Panel Light Models , , , , ,

By order of American Power Conversion Holdings Inc. at New Taipei City, Taiwan

Report for Excelsys EMC Measurements for 6Xgen Purchase Order: by Project Number EMT08J027

Report No.: 11A080304E-E Page 1 of 35. CE Test Report. (Declaration of Conformity) for. Electromagnetic Compatibility.

EMC Test Report For Changzhou Airwheel Technology Co.,Ltd. Airwheel Model: A6S,A6,A6P,A6PS,A6T,A6TS

APPLICATION FOR EMC DIRECTIVE. On Behalf of. Shenzhen Qinhan Lighting Co., Ltd. led flood light. Trade Name:

Discontinuous Disturbance (Click) EN : 2011 Clause Pass Radiated Emission, 30MHz to 1000MHz

Guangdong East Power Co., Ltd. Uninterruptible Power Systems

TEST REPORT. Report Number: DAL-001 Project Number: G Report Issue Date: February 6, 2013

Report on the EMC Testing. For. Exception EMS Ltd. RBK-ILS Processor. Report No. TRA A. 29 th April 2016

Test Report GUANGDONG EAST POWER CO., LTD

APPENDIX A. GENERAL DESCRIPTION OF EQUIPMENT UNDER TEST

Report No.: 9A042401C2 Page 1 of 36. Test Report EN : Prepared for

EMC TEST REPORT. For. Switching Mode Power Adaptor. Model No.: 9W/14.4V/EU(18V/1.0A), 19W/14.4V/EU(12V/1.5A)

CE TEST CERTIFICATION

CONFORMANCE TEST REPORT FOR EN /-6

EMC Testing Report. StarCam Genie N/A MICRO-STAR INT L CO., LTD.

EMC TEST REPORT For TEA-Energy China Limited T8 LED Tube Model No.: T8-25W-150-ND-W-T00 Additional Model No: Please Refer To Page 58

2620 Modular Measurement and Control System

CE/EMC TEST REPORT. For HK QNOVATOR TECHNOLOGY CO.,LIMITED GS02-M X1, BL02, GS01, GS01-M, GS02, GS03, GS04, GS05, GS06, GS07, GS08, GS09, GS10

EMC TEST REPORT For. Shenzhen Smar TEC Technology Company. Smart Charger For Li-Ion&Lifepo4 Battery Pack. Model No.:SPS-F12S02-021(42.

CE EMC Test Certification

9. Electrostatic Discharge Immunity Test (ESD)

TEST SUMMARY Seite 2 von 27. Prüfbericht - Nr.: Test Report No HARMONICS ON AC MAINS RESULT: Passed

CTS (NINGBO) TESTING SERVICE TECHNOLOGY INTERNATIONAL OPERATE ACCORDING TO ISO/IEC EMC TEST REPORT

PT. SARANA KARYA SOLUSINDO.

ETSI EN V2.2.0 ( ) ETSI EN V2.1.1 ( ) TEST REPORT. United GULF GATE Co.

EMC TEST REPORT. Report No.: CE10-LIE040101E

EMC TEST REPORT For. Shenzhen Micsig Instruments Co., Ltd. Handheld Multifunctional Oscilloscope. Model No.: MS520S

TEST REPORT. : The submitted samples complied with the above EMC standards. TRF No.: AS NZS (2012)-b

Shenzhen CTL Electromagnetic Technology Co., Ltd. Tel: Fax: TEST REPORT

EMC TEST REPORT. According to

EMC TEST REPORT For. Global Tech China Limited. 120/200 Watt Mightylite. Model No.: Additional Model No: Please Refer To Page 57

Report No.: 9A042401C1 Page 1 of 51. Test Report. EN 50155: 2007 (EMC, Characteristic, Environmental Test) Prepared for

ELECTRONICS TESTING CENTER, TAIWAN

EMC Test Report. Shenzhen JT Detection Technology Co., Ltd. Product : Car LED headlight bulbs Brand Name :WEIYAO AUTO LED.

EMC TEST REPORT CE TEST REPORT. for Audio / Video receivers and associated equipment

EMC TEST REPORT. : 4F, No. 50-1, Section 1, Hsin-Sheng S. Rd. Taipei, Taiwan. Taiwan

BS EN TESTS ON THE IT TOXIC GAS DETECTOR MODULE

Dongguan Nore Testing Center Co., Ltd. Report No.: NTC F TABLE OF CONTENTS

TABLE OF CONTENTS Page 1 of VERIFICATION OF CONFORMITY SYSTEM DESCRIPTION PRODUCT INFORMATION SUPPORT EQUIPMENT

Test Report Report No.: G150424B02-03EN Date: May. 07, 2015 Page 1 of 49

CE EMC CERTIFICATION

EN v3.1.1 TEST REPORT FOR. Bluetooth Serial Port Module MODEL NUMBER: LMX9838 REPORT NUMBER: 14U17620-E1V3 ISSUE DATE: AUGUST 31, 2017

Test Verification of Conformity

Transcription:

Page 1 of 32 EMC TEST REPORT Report No.: TS11020117-EME Model No.: NS-PSE, NS-POINTED, NS-PSQUARE, NS-PF-S, NS-PT, NS-PR, NS-PU, NS-PF-H, NS-BALIBA, NS-FLEXMA Issued Date: Mar. 01, 2011 Applicant: NORTE SIRIUS ENTERPRISE CO., LTD. 195-1, Shin-Sheng St., Chung-Ho Dist, New Taipei City, Taiwan Test Method/ Standard: EN 61000-6-3: 2007 IEC 61000-3-2: 2005+A2: 2009 IEC 61000-3-3: 2008 EN 61000-6-1: 2007 Test By: Intertek Testing Services Taiwan Ltd., Hsinchu Laboratory No. 11, Lane 275, Ko-Nan 1 Street, Chia-Tung Li, Shiang-Shan District, Hsinchu City, Taiwan Note: Supersede Report No.: EME-040494 dated (Mar. 15, 2004). It may be duplicated completely for legal use with the allowance of the applicant. It shall not be reproduced except in full, without the written approval of Intertek Laboratory. The test result(s) in this report only applies to the tested sample(s). The test report was prepared by: Sign on File Julie Wang/ Assistant These measurements were taken by: Sign on File Fred Yu/ Engineer The test report was reviewed by: Name Lion Chiu Title Engineer

Page 2 of 32 Table of Contents 1. General Information... 4 1.1 Identification of the EUT... 4 1.2 Additional information about the EUT... 4 2. Test Summary... 5 3. Test Specifications... 6 3.1 Standards... 6 3.2 Performance criteria... 7 3.3 Performance verification... 7 3.4 Mode of operation during the test... 7 4. Conducted Emission Test... 8 5. Radiated Emission Test...9 5.1.1 Test Procedure from 30 MHz to 1000 MHz... 9 5.1.2 Test Equipment... 10 5.1.3 Radiated Emission Limit... 10 5.1.4 Uncertainty of Radiated Emission... 10 5.1.5 Radiated Emission Test Data from 30 MHz to 1000 MHz... 11 6. Harmonics Test... 13 7. Voltage Fluctuations-Flicker Test... 14 8. Electrostatic Discharge Immunity Test... 15 8.1 Purpose... 15 8.2 Test Set-Up... 15 8.3 Test Specification... 15 8.4 Test Equipment... 15 8.5 Test Result... 16 9. Radiated, Radio-Frequency, Electromagnetic Field Immunity Test... 17 10. Electrical Fast Transient/Burst Immunity Test... 18 11. Surge Immunity Test... 19 12. Immunity to Conducted Disturbances, Inducted by Radio-Frequency Fields... 20 13. Power Frequency Magnetic Field Immunity Test... 21 14. Voltage Dips, Short Interruptions and Voltage Variations Immunity Test... 22 Appendix A1: External photo of EUT (Model No: NS-PSE)... 23 Appendix A2: External photo of Series Model (Model No: NS-POINTED)... 24 Appendix A3: External photo of Series Model (Model No: NS-PSQUARE)... 25 Appendix A4: External photo of Series Model (Model No: NS-PF-H)... 26 Appendix A5: External photo of Series Model (Model No: NS-PF-S)... 27 Appendix A6: External photo of Series Model (Model No: NS-PU)... 28

Page 3 of 32 Appendix A7: External photo of Series Model (Model No: NS-PT)... 29 Appendix A8: External photo of Series Model (Model No: NS-PR)... 30 Appendix A9: External photo of Series Model (Model No: NS-BALIBA)... 31 Appendix A10: External photo of Series Model (Model No: NS-FLEXMA)... 32

Page 4 of 32 1. General Information 1.1 Identification of the EUT Product: Massage Pillow Series With Vibrator Units Model No.: NS-PSE Rated Power: DC 3 V Power Cord: N/A Sample receiving date: Feb. 23, 2011 Sample condition: Workable Testing date: Feb. 24, 2011 Note 1: This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Note 2: The test report only allows to be revised within three years from its original issued date unless further standard or the requirement was noticed. Note 3: When determining the test conclusion, the Measurement Uncertainty of test has been considered. 1.2 Additional information about the EUT The customer confirmed the models NS-POINTED NS-PSQUARE NS-PF-S NS-PT NS-PR NS-PU NS-PF-H NS-BALIBA and NS-FLEXMA are series models to NS-PSE (EUT), for these models are identical in hardware aspect. MOTOR: MABUCHI brand motor RC-260RA-21785A. The vibrator unit information please see listed as below. Vibrator Unit Model No NS-POINTED NS-PSQUARE NS-PF-S NS-VS NS-PF-H NS-VSL NS-PT NS-PR NS-PU NS-PSE NS-VD NS-PSE For more detail features, please refer to user's Manual.

Page 5 of 32 2. Test Summary Emission (EN 61000-6-3: 2007) Standard Test Type Result Remarks Conducted Test N/A N/A CISPR 16-2-3: 2006 Radiated Test PASS Meet the requirements IEC 61000-3-2: Harmonic current emissions N/A N/A 2005+A2: 2009 IEC 61000-3-3: 2008 Voltage fluctuation & flicker N/A N/A Immunity (EN 61000-6-1: 2007) Standard Test Type Performance Criteria Result Test Judgment IEC 61000-4-2: 2008 ESD test Criterion B PASS Meets the requirements of Performance Criterion A IEC 61000-4-3: 2010 RS test Criterion A N/A N/A IEC 61000-4-4: 2004 EFT test Criterion B N/A N/A IEC 61000-4-5: 2005 Surge test Criterion B N/A N/A IEC 61000-4-6: 2008 CS test Criterion A N/A N/A IEC 61000-4-8: 2009 Magnetic Field test Criterion A N/A N/A IEC 61000-4-11: 2004 Dip test 1. 100% reduction- Performance Criterion B 2. 100% reduction- Performance Criterion B 3. 30% reduction- Performance Criterion C 4. 100% reduction- Performance Criterion C N/A N/A

Page 6 of 32 3. Test Specifications 3.1 Standards EN 61000-6-3: 2007 Electromagnetic Compatibility Generic emission standard - For Residential, commercial and light industry environments. CISPR 16-2-3: 2006 Specification for radio disturbance and immunity measuring apparatus and methods-part 2-3: Methods of measurement of disturbances and immunity-radiated disturbance measurements. IEC 61000-3-2: 2005+A2: 2009 Electromagnetic compatibility Part 3. Limits Section 2. Limits for harmonic current emissions (equipment input current 16 A per phase) IEC 61000-3-3: 2008 Electromagnetic compatibility Part 3. Limits Section 3. Limitation of voltage fluctuations and flicker in low-voltage supply systems for equipment with rated current 16 A EN 61000-6-1: 2007 Electromagnetic compatibility - Generic immunity standard - For Residential, commercial and light industry environments.

Page 7 of 32 3.2 Performance criteria The performance criterias listed below are based on those regulated in the standard, specified by the manufacturer or derived from the product specification. Criteria A: The apparatus shall continue to operate as intended during and after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended. Criteria B: The apparatus shall continue to operate as intended after the test. No degradation of performance or loss of function is allowed below a performance level specified by the manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is however allowed. No change of actual operating state or stored data is allowed. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, either of these may be derived from the product description and documentation and what the user may reasonably expect from the apparatus if used as intended. Criteria C: Temporary loss of function is allowed, provided the function is self-recoverable or can be restored by the operation of the controls. 3.3 Performance verification The EUT has been monitored based on manufacturer s specification; the performance fulfilled the requirements of standard. 3.4 Mode of operation during the test The EUT was supplied with DC 3 V from battery and was tested in normal operating mode during all the tests.

Page 8 of 32 4. Conducted Emission Test Since the EUT is not connected to AC source, therefore, the test can be waived.

Page 9 of 32 5. Radiated Emission Test 5.1.1 Test Procedure from 30 MHz to 1000 MHz The figure below shows the test setup, which is utilized to make these measurements. 1.0~4.0 meters Antenna Tower 10 meters Receiver Antenna EUT 0.8m Ground Plane RF Test Receiver Radiated testing was performed at a 10 meters open area test site. The equipment under test were placed on a turntable top 0.8 meter above ground. The table was 360 degrees to determine the position of the highest radiation. EUT is set 10 meters from the EMI receiving antenna, which is mounted on a variable height mast. The antenna height is varied between one meter and four meters above ground to find the maximum value of the field strength. Both horizontal polarization and vertical polarization of the antenna was set to conduct the measurement. The bandwidth was set on the EMI meter 120 khz. The levels are quasi peak value readings. The frequency spectrum from 30 MHz to 1000 MHz was investigated.

Page 10 of 32 5.1.2 Test Equipment Equipment Brand Model No. EMI Receiver Rohde & Schwarz ESCS 30 Bilog Antenna Schaffner CBL6112B Note: The above equipments are within the valid calibration period. 5.1.3 Radiated Emission Limit Frequency (MHz) Distance(m) QP(dBμV) 30~230 10 30 230~1000 10 37 Note: 1. The tighter limit shall apply at the edge between two frequency bands. 2. Distance refers to the distance in meters between the measuring instrument Antenna and the closest point of EUT. 5.1.4 Uncertainty of Radiated Emission Expanded uncertainty (k=2) of radiated emission measurement is ± 4.96 db.

Page 11 of 32 5.1.5 Radiated Emission Test Data from 30 MHz to 1000 MHz Polarity: Vertical Temperature: 25 Model No.: NS-PSE Relative Humidity: 58 % Operating mode: Refer to section 3.4 Atmospheric Pressure: 1008 hpa Remark: N/A Freq. (MHz) Ant. Factor (db/m) Cable Loss (db) Reading (dbμv) Calculated (dbμv/m) Limit (dbμv/m) Margin (db) 156.09000 8.82 3.03 6.55 18.40 30-11.60 165.00000 9.41 3.03 4.66 17.10 30-12.90 197.40000 10.19 3.13 6.08 19.40 30-10.60 470.00000 16.97 4.75 3.28 25.00 37-12.00 521.20000 18.39 5.48 2.63 26.50 37-10.50 816.60000 21.50 6.30 0.10 27.90 37-9.10 Remark: 1. Calculated level (dbμv/m)= Correction Factor (db/m)+ Meter Reading (dbμv) 2. Correction Factor = Ant. Factor (db/m) + cable loss (db) 3. Margin Value = Calculated level- Limit Value 4. * Undetectable

Page 12 of 32 Polarity: Horizontal Temperature: 25 Model No.: NS-PSE Relative Humidity: 58 % Operating mode: Refer to section 3.4 Atmospheric Pressure: 1008 hpa Remark: N/A Freq. (MHz) Ant. Factor (db/m) Cable Loss (db) Reading (dbμv) Calculated (dbμv/m) Limit (dbμv/m) Margin (db) 162.84000 8.78 3.03 6.39 18.20 30-11.80 171.21000 8.84 3.03 5.23 17.10 30-12.90 252.75000 11.42 3.50 9.38 24.30 37-12.70 379.10000 15.78 4.33 6.79 26.90 37-10.10 496.70000 17.88 4.75 1.57 24.20 37-12.80 551.30000 17.69 5.48 0.03 23.20 37-13.80 Remark: 1. Calculated level (dbμv/m)= Correction Factor (db/m)+ Meter Reading (dbμv) 2. Correction Factor = Ant. Factor (db/m) + cable loss (db) 3. Margin Value = Calculated level- Limit Value 4. * Undetectable

Page 13 of 32 6. Harmonics Test Since the EUT is not connected to AC source, therefore, the test can be waived.

Page 14 of 32 7. Voltage Fluctuations-Flicker Test Since the EUT is not connected to AC source, therefore, the test can be waived.

Page 15 of 32 8. Electrostatic Discharge Immunity Test 8.1 Purpose The object of the test is to evaluate the ESD immunity performance of EUT. 8.2 Test Set-Up A horizontal coupling plane (HCP) was placed on a non-metallic table 0.8 meter above a reference ground plane (RGP) and connected to it with a cable with two 470 kω resistors. The EUT was placed on an insulation sheet on the HCP and was operated according to the specified operating mode. A vertical coupling plane (VCP) was connected to the RGP with a cable with two 470 kω resistors. 8.3 Test Specification Test level: Air discharge ------- +/- 8 kv Contact discharge ------- +/- 4 kv Single discharge at 1 second interval positive discharge and negative discharge The selected test points are listed in this table, the numbers refer to the figures attached. 8.4 Test Equipment Equipment Manufacturer Model No. Electrostatic Discharge System NoiseKen ESS-2002 Note: The above equipments are within the valid calibration period.

Page 16 of 32 8.5 Test Result Temperature: 25 Model No.: NS-PSE Relative Humidity: 50 % Operating mode: Refer to section 3.4 Atmospheric Pressure: 1008 hpa Remark: N/A Point of Discharge Contact Test Point Air Test Point Applied Voltage (kv) Total No. of Discharge (Each Point) Result Remark ±2 20 PASS Criterion A ±4 20 PASS Criterion A ±2 20 PASS Criterion A ±4 20 PASS Criterion A ±6 20 PASS Criterion A ±8 20 PASS Criterion A VCP ±2 20 PASS Criterion A (4 sides) ±4 20 PASS Criterion A HCP ±2 20 PASS Criterion A (4 sides) ±4 20 PASS Criterion A Description of Discharge Point Contact Discharge 1 Test points Metallic Screws Metallic Case Metallic Connect ports Metallic Junctions Others: Air Discharge Plastic Screws Plastic Case (gap) Plastic Connect ports Plastic Junctions LED indicator Panel Board Others: Enclosure

Page 17 of 32 9. Radiated, Radio-Frequency, Electromagnetic Field Immunity Test After engineer judgment,no tests were considered necessary.

Page 18 of 32 10. Electrical Fast Transient/Burst Immunity Test Since the EUT is not connected to AC source, therefore, the test can be waived.

Page 19 of 32 11. Surge Immunity Test Since the EUT is not connected to AC source, therefore, the test can be waived.

Page 20 of 32 12. Immunity to Conducted Disturbances, Inducted by Radio-Frequency Fields Since the EUT is not connected to AC source, therefore, the test can be waived.

Page 21 of 32 13. Power Frequency Magnetic Field Immunity Test The equipment does not contain components susceptible to magnetic fields; therefore, the test can be waived

Page 22 of 32 14. Voltage Dips, Short Interruptions and Voltage Variations Immunity Test Since the EUT is not connected to AC source, therefore, the test can be waived.

Appendix A1: External photo of EUT (Model No: NS-PSE) Report No.: TS11020117-EME Page 23 of 32

Appendix A2: External photo of Series Model (Model No: NS-POINTED) Report No.: TS11020117-EME Page 24 of 32

Appendix A3: External photo of Series Model (Model No: NS-PSQUARE) Report No.: TS11020117-EME Page 25 of 32

Appendix A4: External photo of Series Model (Model No: NS-PF-H) Report No.: TS11020117-EME Page 26 of 32

Appendix A5: External photo of Series Model (Model No: NS-PF-S) Report No.: TS11020117-EME Page 27 of 32

Appendix A6: External photo of Series Model (Model No: NS-PU) Report No.: TS11020117-EME Page 28 of 32

Appendix A7: External photo of Series Model (Model No: NS-PT) Report No.: TS11020117-EME Page 29 of 32

Appendix A8: External photo of Series Model (Model No: NS-PR) Report No.: TS11020117-EME Page 30 of 32

Appendix A9: External photo of Series Model (Model No: NS-BALIBA) Report No.: TS11020117-EME Page 31 of 32

Page 32 of 32 Appendix A10: External photo of Series Model (Model No: NS-FLEXMA)