Autofluor. Autoradiographic Image Intensifier. Documented... Autofluor is Superior! C 3 PPO-DMSO. Autofluor

Similar documents
Amersham Amplify Fluorographic Reagent

MINIMUM REQUIREMENTS FOR A DARKROOM.

Guide to Manual Processing of NDT Films

5 Using KODAK EKTACOLOR RA Chemicals with Tray, Drum, and Rotary-Tube Processors

imaging guide metalphoto 400 PROCESSING

KODAK MIN-R S Film / 4906

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

CARESTREAM INDUSTREX Digital Imaging Plates

How to Print: Making an Enlargement from a Negative in the Darkroom

10 ROTARY-TUBE PROCESSORS

Film and processing quality assurance

Capillary Film Troubleshooting. Pinholes. Stencil underexposed

ILFORDINFO HOW TO PROCESS YOUR FIRST BLACK AND WHITE FILM

KODAK Simulation Film / 7157

KODAK T-MAX 100 Direct Positive Film Developing Outfit

FORMULARY P.O. Box 950 Condon MT FAX

Anatomix Plus X-Ray System

Wimberley Developer #2, Version D+ 1 liter kit (Dry) CATALOG NO TO MAKE 50 LITERS OF WORKING SOLUTION

KODAK INDUSTREX AA400 Film Versatility is the key.

50 Tips for Manual Processing

Anatomix RP X-Ray System

RD-90 Developer-Replenisher F-Fix Fixer-Replenisher

KODAK Medical X-ray Film / General Purpose / Blue / 3528 / MXB

ILFORD FACT SHEET ILFORD NUCLEAR EMULSIONS. HARMAN technology Limited TECHNICAL INFORMATION FOR PARTICLE PHYSICS APPLICATIONS

ihcdirect Slide Manager

Processing and. Photography. Printing

KODAK EKTACHROME RADIANCE III Paper

KODAK PROFESSIONAL AZO Paper

CARESTREAM INDUSTREX Digital Imaging Plates

KODAK X-OMAT BT Film / 4530 / XBT

KODAK PROFESSIONAL TRI-X 320 and 400 Films

KODAK PROFESSIONAL T-MAX Developers

Processing Film. How do I develop and fix the latent image on my film so I can make prints? By Marcine Linder

E3 UV-30 Resist Film Instructions

TECHNICAL INFORMATION

ARS-IMAGO CHEMICALS DATA SHEETS

MULTIGRADE FB WARMTONE 1

Troubleshooting. Agfa Dentus Intraoral radiography Troubleshooting Guide. Giving a hand to oral health.

Sketchpaint. Ideal for turning any smooth surface into a whiteboard. Ready to use in 5 days

Ink-Use Guidance for GP-1810D

Using KODAK Negative Film Processing Chemicals, Type L

Using the KODAK Negative Film Processing Cartridges FC1 and FC2

KODAK PROFESSIONAL T-MAX P3200 Black & White Negative Film

Fig. 1. A. Adjustable section of film holder. B. Notched portion. C. Projection guides. D. Back stop

KODAK PROFESSIONAL T-MAX P3200 Black & White Negative Film

DNA extraction Protocol for Agencourt Genfind v2 Blood and Serum Genomic DNA Isolation Kit

Photo graph ic Sens itizer for Cloth and Pape r

AGENCOURT GENFIND Blood & Serum Genomic DNA Isolation Kit

Application of 3M Pressure Sensitive Films to 3M Panagraphics Substrates

PERCEPTOL, ID-11 AND MICROPHEN FILM DEVELOPERS

Ink-Use Guidance for GP-1810

KODAK PROFESSIONAL KODABROME II RC Paper

NOTE: This product can be used externally if UV Guard is added (BY REQUEST ONLY).

Using the KODAK Negative Film Processing Cartridges FC1 and FC2

ISO 400/27 o BLACK AND WHITE PROFESSIONAL FILM FOR HIGH PRINT QUALITY AND FLEXIBILITY IN USE

Contains chemicals to make approximately 24 8 x 10 prints

Photomultiplier Tube

KMPR 1010 Process for Glass Wafers

How to use a Touch Up Bottle & Brush

The Silver Gelatin Photographic Print

380 Swimming Pool Paint

GLASS SCREENPRINTING - ARCHITECTURE

LUXAPOOL EPOXY POOL COATING APPLICATION GUIDE. New Cement Pools

mi-mag mrna Isolation Kit

A simple improvement for MBDCG

Alternative Photo Processes

Magnetpaint & Sketchpaint

Item # : TL200C Description : Talia Cocktail Table Product Size : W 47" x D 24" x H 19"

Technical Newsletter

EASTMAN TRI-X Reversal Film 7278

PAPER No. 3; FINGERPRINTS AND OTHER IMPRESSIONS Module No. 19; Silver Nitrate Method

A POWDER FILM DEVELOPER AND REPLENISHER FOR THE HIGH VOLUME BLACK AND WHITE FILM PROCESSING IN DEEP TANKS AND DIP & DUNK (HANGER) PROCESSORS

KODAK TRI-X Pan and KODAK TRI-X Pan Professional Films

BLACK AND WHITE, ORTHOCHROMATIC COPY FILM

INTRODUCTION TO THE FPC PROCESS CONTROL

DULUX UNIVERSAL UNDERCOAT

Chemistry Safety Worksheet

SPRINGFIELD TECHNICAL COMMUNITY COLLEGE ACADEMIC AFFAIRS

Printing. Registering the print Printing!

Practical Information: ORALITE V98 Conformable Graphic Sheeting

KODAK AEROCHROME III MS Film 2427

ELITE Chrome 400 Film

TECHNICAL INFORMATION

The Ophthalmic Darkroom: Processing and Printing Fluorescein Angiograms 179

Care and Use of the VP 407AM-N 96 Pin Magnetic Bead Extractor

400 PROFESSIONAL FACT SHEET ISO 400/27º, FINE GRAIN, BLACK AND WHITE PROFESSIONAL FILM FOR SUPERB PRINT QUALITY. September 2002

Polymer Plate Development Procedures. (800) or (802) (800)

TECHNICAL DATA / COLOR PAPER July 2003 E-19

Big Sky Product Information Sheet. Epoxy Prime Primer/Sealer PS3042 (Lt. Gray) PS3044 (Dk. Gray) PS3045 (Black) PS3047 (Yellow Oxide)

KODAK PROFESSIONAL POLYCONTRAST III RC Paper

PrintED Press Operations Sample Exam Questions

COMPOSITES LAB MANUAL

PINHOLES and TRIANGLES

ELITE Chrome 100 Film

8-746 High Production Non-Sanding Primer Grey GS907

Radiology. Radiograph: Is the image of an object made with use of X- ray instead of light.

Prototype PCBs implementatio n session

KODAK EKTACHROME 64 Professional Film

Preparation and Properties of Soap Experiment #7

PAPER AND CARD PACKAGING DESIGN TIPS FOR RECYCLING

Transcription:

Autofluor TM Autoradiographic Image Intensifier 3 H 14 C 3 H 14 C Documented... Autofluor is Superior! -- Perng (1988), Analytical Biochemistry, 173, 387-392 PPO-DMSO Autofluor Toll Free (800) 526-3867 Atlanta (404) 699-2121 UK (44) 01482-646022

TABLE OF CONTENTS Directions Gels... 1 Paper Chromotography and TLC Plates... 3 Problem Solving Guide... 5 Image Quality... 6 Blackening or Cloudiness on Image... 9 Sharply Defined Images... 12

Autofluor TM DIRECTIONS FOR USE A. GELS 1. After staining, fix the gel with 5% glacial acetic acid, 5% isopropyl alcohol, and 90% water. Fix for 15 to 20 minutes. Pour off fixing solution and discard according to radioactive disposal procedures. 2. Rinse the gel in a continuous flow of tap water for 15 minutes to assure the complete removal of acetic acid residue. [To prevent crystal formation, it is important that the gel be thoroughly rinsed after fixing. Should the gel develop white crystals on contact with Autofluor, dissolve the precipitate by soaking the gel in a solution of 1g sodium carbonate/100ml water or 1X TRIS Buffer. Soak the gel in Autofluor until the white precipitate dissolves. Repeat from the beginning of step two.] - 1 -

3. Cover gel with Autofluor until the depth of Autofluor is twice the thickness of the gel. Gently agitate in Autofluor for 30 min/mm of gel thickness. Pour off remaining Autofluor and retain for future use. Label reserved material as radioactive. Autofluor may be reused several times before a diminishing response is observed. 4. DO NOT WASH GEL. Place directly on filter paper and dry on gel dryer under heat (80 o C) and vacuum. 5. The gel will have a white to light tan sparkling appearance similar to freshly fallen snow. 6. Place on film and expose at -76 o C. Due to the higher light output of the Autofluor phosphor, less exposure time is needed for gels treated with Autofluor than for gels treated with PPO/DMSO. Sufficient exposure time for a 5000 dpm/band is 24 hours. Overexposure of the film will cause the bands to become fuzzy and resolution to be lost. 7. Develop film according to manufacturer s instructions. - 2 -

B. PAPER CHROMATOGRAPHY AND TLC PLATES: 1. Spray twice or dip plates in Autofluor and allow to dry. 2. Place on film and expose at -76 o C. TO MAXIMIZE AUTOFLUOR EFFICIENCY: If gels crack or stick during drying, add 0.5% (5ml/liter) of glycerol directly to the Autofluor before using. Since Autofluor is inducted into the gel by crystallization in situ as opposed to precipitated, it is advantageous to form the smallest crystals possible. This is accomplished by drying as quickly as possible under the strongest vacuum possible. A vacuum pump with a good seal on the dryer is preferred over a house vacuum. After the gel appears dry, turn off heat and continue vacuum for another 1/2 hour. - 3 -

APPROXIMATE FILM EXPOSURE TIME: ISOTOPE dpm/band Beq./band EXPOSURE(hr) 3 H 500 8.3 48-72 3 H 5000 83 24 14 C/ 35 S 300 5.0 24 14 C/ 35 S 1000 17 8-12 32 P 500 8.3 12 NOTE: 300dpm=5dps(Beq.)=0.14nCi STORAGE: Store at room temperature, out of direct sunlight. Keep from freezing. At temperatures less than 20 o C precipitation of the water soluble phosphor may occur. Warming to approximately 30 o C will redissolve these phosphors. PACKAGING: One liter amber glass bottle. SHIPPING WEIGHT: 4 lbs./liter Autofluor is not considered a hazardous waste as per EPA regulation CFR 40 Part 261 Appendix 7 Sub-Section D. - 4 -

PROBLEM-SOLVING GUIDE This guide is organized to address the three main categories of problems that can occur in autoradiography. To use this guide, carefully examine the final film to determine the general category of the problem you are experiencing. Once the problem has been diagnosed, scan the possible sources for the most likely cause and solution. The major types of autoradiography artifacts are: I. Poor Image Quality (see Table 1) A. Faint Image B. Poor Resolution C. Patchy Image II. Blackening or Cloudiness of Image (see Table 2) A. Fogging All Over B. Fogging that Follows Gel Outline C. Fogging not on Gel III. Sharply-Defined Images (see Table 3) A. Ragged/Lightening-Like Images B. Black Spots, Splash Marks C. Localized, Small Black Spots D. Geometrical Shading E. Crescent-Shaped Marks - 5 -

TABLE 1: POOR IMAGE QUALITY PROBLEM: FAINT IMAGE SOURCE Incorrect Exposure Temperature Incorrect Film Exposure Time too Short for Levels of Activity Used Overused Developer No Pre-flash Isotope Activity Levels too Low Quenching of Light Due to Presence of Stain in Gel SOLUTION Expose film at -76 o C. Consult film directions. Increase exposure time. Use fresh processing chemicals. Pre-flash film for autoradiography. Check calculations. Elute dye with ethanol. - 6 -

TABLE 1: POOR IMAGE QUALITY (CONT.) PROBLEM: POOR RESOLUTION SOURCE Urea in Gel Poor Initial Separation Poor Contact between Gel and Film Ice Crystals Develop in Wet Gels. Diffusion of Bands SOLUTION To remove urea, soak gel in 6% acetic acid. Rinse thoroughly. Repeat separation stage. Make sure cassette is properly assembled. Dry the gel thoroughly before exposure. Reduce exposure time to film. - 7 -

TABLE 1: POOR IMAGE QUALITY (CONT.) PROBLEM: POOR RESOLUTION (CONT.) SOURCE Loss of Resolution Due to the Use of an Intensifying Screen. SOLUTION Eliminate the screen and expose longer if necessary. PROBLEM: PATCHY IMAGE Poor Contact Between Film and Object Dust on Intensifying Screen Uneven Gel Drying Using a good quality cassette will provide even pressure. Keep screens clean. Check for clogging in dryer vents. - 8 -

TABLE 2: BLACKENING OR CLOUDINESS ON IMAGE PROBLEM: FOGGING ALL OVER SOURCE Pre-flash too Bright Processing Chemicals too Old Light Getting into the Darkroom Use of Old Film High Radiation Close to Film Stocks Wrong Safelight/ Safelight too Close to Film SOLUTION Determine proper degree of flash required. Use Kodak Wratten filters No. 21 and 22 and vary the flash distance from the film. Use new processing chemicals. Be sure to completely seal off the dark room from light. Be sure that the film has not expired. Move the film stocks away from radiation. Check the wattage and filters. Move the film if it is too close to light. - 9 -

TABLE 2: BLACKENING OR CLOUDINESS ON IMAGE PROBLEM: FOGGING THAT FOLLOWS GEL OUTLINE SOURCE Light Emission from Fluor in Substrate Radioactive Material Contaminating Gel Components, or Fluorographic Reagent SOLUTION Make sure to dark adapt the gel for about 35 minutes before exposing it to film. Count all samples and do not use any that are contaminated. PROBLEM: FOGGING NOT ON GEL Film Contaminated with Processing Chemicals Radioactive/ Chemical Contamination Pressure Marks from Rollers on Processing Equipment Keep the dark room clean. Watch for spills. Always clean the cassette before use. Film should be at room temperature before use. - 10 -

TABLE 2: BLACKENING OR CLOUDINESS ON IMAGE (CONT.) PROBLEM: FOGGING THAT FOLLOWS GEL OUTLINE SOURCE Chemography or Chemical Fogging SOLUTION This is caused by insufficient drying. Dry gels thoroughly before exposure. Also quick rinse the gels before drying. Run all control gels without activity. - 11 -

TABLE 3: SHARPLY DEFINED IMAGES PROBLEM: RAGGED/LIGHTNING-LIKE IMAGES SOURCE Electric Charge Build-Up from Use of Plastic Wrap on Film or Gel SOLUTION Discharge the static before handling. Avoid using adhesive tape on film. PROBLEM: BLACK SPOTS OR SPLASH MARKS Dripping Fixer on Underdeveloped Film Clean up spills immediately. PROBLEM: LOCALIZED, SMALL BLACK SPOTS Storage of Film Near Radiation Move the film away from all sources of x-rays and gamma rays. - 12 -

TABLE 3: SHARPLY DEFINED IMAGES (CONT.) PROBLEM: GEOMETRICAL SHADING SOURCE Exposure of Film to Light Film Developing Unevenly SOLUTION Seal off the dark room. Check the wattage of the bulb in the safelight. Keep the films separated and agitate films during development. PROBLEM: CRESCENT SHAPED MARKS ALL OVER Bending of Film before or after Exposure Bending the film before exposure causes white crescents. Bending the film after exposure causes black crescents. - 13 -

For Orders or Questions Call Phone: 404-699-2121 Toll-Free 800-526-3867 Fax: 404-699-2077 England: 44-01482-646022 44-01482-646020 Fax: 44-01482-646013 National Diagnostics U.K. Unit 4, Fleet Business Park Itlings Road Hessle, Hull HU13 9LX, England National Diagnostics 305 Patton Drive Atlanta, GA 30336