Advanced Design System Feburary 2011 X-Parameter Generator

Similar documents
Advanced Design System Feburary 2011 Large-Signal S-Parameter Simulation

Advanced Design System 2011 September 2011 RF Power Amplifier Test Benches

Advanced Design System Feburary 2011 Harmonic Balance Simulation

Advanced Design System 2011 September 2011 Load Pull DesignGuide

Advanced Design System Feburary 2011 S-Parameter Simulation

Gain Compression Simulation

Large-Signal S-Parameter Simulation

Large-Signal S-Parameter Simulation

Advanced Design System 2011 September 2011 TD-SCDMA DesignGuide

Advanced Design System 2011 September 2011 S-Parameter Simulation

Advanced Design System Feburary 2011 Linearization DesignGuide

Advanced Design System 2011 September 2011 Circuit Envelope Simulation

Advanced Design System 2011 September 2011 Measurement Expressions

Advanced Design System 2011 September 2011 Vendor Component Libraries - RF Passive SMT Library

Advanced Design System Feburary 2011 Passive Circuit DesignGuide

Advanced Design System Feburary 2011 WLAN DesignGuide

Harmonic Balance Simulation

EMPro EMPro Examples. EMPro 2010 May 2010 EMPro Examples

Advanced Design System 2011 September 2011 TD-SCDMA Design Library

Advanced Design System 2011 September 2011 Mixer DesignGuide

Advanced Design System Feburary 2011 WLAN 11n Design Library

Advanced Design System 2011 September 2011 WLAN Design Library

Agilent N7509A Waveform Generation Toolbox Application Program

User manual Automatic Material Alignment Beta 2

LD2342 USWM V1.6. LD2342 V1.4 Page 1 of 18

Advanced Design System Feburary 2011 Mixer DesignGuide

Sheet Metal Design Guidelines

Projects Connector User Guide

Pin Tool. Assembly Guide. For Research Use Only. Not for use in diagnostic procedures. Original Instructions

Ultra-Wideband DesignGuide

UM DALI getting started guide. Document information

Oracle Real-Time Scheduler

RFDE Broadband SPICE Model Generator

Sheet Metal Design Guidelines

Advanced Design System 2011 September 2011 System Models

Advanced Design System - Fundamentals. Mao Wenjie

The BioBrick Public Agreement. DRAFT Version 1a. January For public distribution and comment

Virtex-5 FPGA RocketIO GTX Transceiver IBIS-AMI Signal Integrity Simulation Kit User Guide

Virtex-5 FPGA RocketIO GTP Transceiver IBIS-AMI Signal Integrity Simulation Kit User Guide

Machining Design Guidelines

UM DALI getting started guide. Document information

Administration Guide. BBM Enterprise. Version 1.3

IMD Measurement Wizard for the E5072A ENA Series Network Analyzer Operation Manual. Agilent Technologies June 2012

AA103-72/-72LF: 10 MHz GHz GaAs One-Bit Digital Attenuator (10 db LSB)

TD-SCDMA DesignGuide May 2007

GamePro Android Edition User Guide for Android Devices

Sheet Metal Design Guidelines

AA104-73/-73LF: 300 khz-2.5 GHz One-Bit Digital Attenuator

DEMO MANUAL DC2349A LTC5586 6GHz High Linearity I/Q Demodulator with Wideband IF Amplifier DESCRIPTION BOARD PHOTO

InfiniiMax Spice Models for the N5381A and N5382A Probe Heads

AN Maximum RF Input Power BGU6101. Document information. Keywords Abstract

Keysight 2-Port and 4-Port PNA-X Network Analyzer

ADS Tutorial: A Beginners Tutorial

TD-SCDMA DesignGuide May 2003

Agilent ParBERT Measurement Software. Fast Eye Mask Measurement User Guide

AUTOTUNE USER GUIDE. R8000 Series Communications System Analyzer. Motorola MOTOTRBO Portable Motorola MOTOTRBO Mobile

AN Replacing HMC625 by NXP BGA7204. Document information

Advanced Test Equipment Rentals ATEC (2832)

Keysight Technologies Vector Network Analyzer Receiver Dynamic Accuracy

PADS Layout for an Integrated Project. Student Workbook

Diode Models. IC-CAP January 2012 Diode Models

TED-Kit 2, Release Notes

Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Analyzer: CXA Signal Analyzer N9000A

AUTOTUNE USER GUIDE. R8000 Series Communications Systems Analyzer

SKY LF: 10 MHz GHz Six-Bit Digital Attenuator with Driver (0.5 db LSB, 31.5 db Range)

AN Ohm FM LNA for embedded Antenna in Portable applications with BGU7003W. Document information. Keywords Abstract

SRT Marine Technology. LD2342 V1.4 Page 1 of 22

AUTOTUNE USER GUIDE. R8000 Series Communications Systems Analyzer. Motorola ASTRO XTL Series Motorola ASTRO XTS Series

SKY LF: GHz Two-Way, 0 Degrees Power Divider

UM10950 Start-up Guide for FRDM-KW41Z Evaluation Board Bluetooth Paring example with NTAG I²C plus Rev February

Spartan-6 FPGA GTP Transceiver Signal Integrity Simulation Kit User Guide For Mentor Graphics HyperLynx. UG396 (v1.

Online Game Scheduling User Guide

SystemVue - ZigBee Baseband Verification Library. SystemVue ZigBee Baseband Verification Library

View Terms and Conditions: Effective 12/5/2015 Effective 6/17/2017

PN7120 NFC Controller SBC Kit User Manual

SKY LF: GHz SP3T Switch, 50 Ω Terminated

Experiment 12 - Measuring X-Parameters Using Nonlinear Vector Netowrk Analyzer

SKY65120: WCDMA PA Bias Method For Lower Junction Temperature

OM29110 NFC's SBC Interface Boards User Manual. Rev May

AN SDARS active antenna 1st stage LNA with BFU730F, 2.33 GHz. Document information

Keysight Spectrum Analyzer Option (090/S93090xA) for PNA/PNA-L/PNA-X/N5290A/N5291A

Keysight 86205B RF Bridge

Digital Filter Designer

Keysight U9397A/C FET Solid State Switch (SPDT)

Using the S5U13781R01C100 Shield Graphics Library with Atmel Studio

SysInfoTools PDF Image Extractor v2.0

SKY LF: 300 khz 3 GHz Medium Power GaAs SPDT Switch

AN BFU725F/N1 2.4 GHz LNA evaluation board. Document information. Keywords. LNA, 2.4GHz, BFU725F/N1 Abstract

Why VPEAK is the Most Critical Aperture Tuner Parameter

Ansys Designer RF Training Lecture 3: Nexxim Circuit Analysis for RF

SKY LF: GHz Five-Bit Digital Attenuator with Serial-to-Parallel Driver (0.5 db LSB)

SKY : MHz Variable Gain Amplifier

Agilent W2100 Antenna Modeling Design System

The EDR Aerial Photo Decade Package

SKY LF: GaAs SP2T Switch for Ultra Wideband (UWB) 3 8 GHz

MN E. Waveform Viewer: Power Xpert Software 2.2

X3D Graphics for Web Authors. X3D-Edit Update. Web3D Consortium Korea Chapter Seoul, 7-8 December Don Brutzman

AS183-92/AS183-92LF: 300 khz-2.5 GHz phemt GaAs SPDT Switch

Applications. Product Description. Features. Ordering Information. Functional Block Diagram

LAB EXERCISE 3 FET Amplifier Design and Linear Analysis

Transcription:

Advanced Design System 201101 - X-Parameter Generator Advanced Design System 201101 Feburary 2011 X-Parameter Generator 1

Advanced Design System 201101 - X-Parameter Generator Agilent Technologies, Inc 2000-2011 5301 Stevens Creek Blvd, Santa Clara, CA 95052 USA No part of this documentation may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent Technologies, Inc as governed by United States and international copyright laws Acknowledgments Mentor Graphics is a trademark of Mentor Graphics Corporation in the US and other countries Mentor products and processes are registered trademarks of Mentor Graphics Corporation * Calibre is a trademark of Mentor Graphics Corporation in the US and other countries "Microsoft, Windows, MS Windows, Windows NT, Windows 2000 and Windows Internet Explorer are US registered trademarks of Microsoft Corporation Pentium is a US registered trademark of Intel Corporation PostScript and Acrobat are trademarks of Adobe Systems Incorporated UNIX is a registered trademark of the Open Group Oracle and Java and registered trademarks of Oracle and/or its affiliates Other names may be trademarks of their respective owners SystemC is a registered trademark of Open SystemC Initiative, Inc in the United States and other countries and is used with permission MATLAB is a US registered trademark of The Math Works, Inc HiSIM2 source code, and all copyrights, trade secrets or other intellectual property rights in and to the source code in its entirety, is owned by Hiroshima University and STARC FLEXlm is a trademark of Globetrotter Software, Incorporated Layout Boolean Engine by Klaas Holwerda, v17 http://wwwxs4allnl/~kholwerd/boolhtml FreeType Project, Copyright (c) 1996-1999 by David Turner, Robert Wilhelm, and Werner Lemberg QuestAgent search engine (c) 2000-2002, JObjects Motif is a trademark of the Open Software Foundation Netscape is a trademark of Netscape Communications Corporation Netscape Portable Runtime (NSPR), Copyright (c) 1998-2003 The Mozilla Organization A copy of the Mozilla Public License is at http://wwwmozillaorg/mpl/ FFTW, The Fastest Fourier Transform in the West, Copyright (c) 1997-1999 Massachusetts Institute of Technology All rights reserved The following third-party libraries are used by the NlogN Momentum solver: "This program includes Metis 40, Copyright 1998, Regents of the University of Minnesota", http://wwwcsumnedu/~metis, METIS was written by George Karypis (karypis@csumnedu) Intel@ Math Kernel Library, http://wwwintelcom/software/products/mkl SuperLU_MT version 20 - Copyright 2003, The Regents of the University of California, through Lawrence Berkeley National Laboratory (subject to receipt of any required approvals from US Dept of Energy) All rights reserved SuperLU Disclaimer: THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL THE COPYRIGHT OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF 2

Advanced Design System 201101 - X-Parameter Generator SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE 7-zip - 7-Zip Copyright: Copyright (C) 1999-2009 Igor Pavlov Licenses for files are: 7zdll: GNU LGPL + unrar restriction, All other files: GNU LGPL 7-zip License: This library is free software; you can redistribute it and/or modify it under the terms of the GNU Lesser General Public License as published by the Free Software Foundation; either version 21 of the License, or (at your option) any later version This library is distributed in the hope that it will be useful,but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE See the GNU Lesser General Public License for more details You should have received a copy of the GNU Lesser General Public License along with this library; if not, write to the Free Software Foundation, Inc, 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA unrar copyright: The decompression engine for RAR archives was developed using source code of unrar programall copyrights to original unrar code are owned by Alexander Roshal unrar License: The unrar sources cannot be used to re-create the RAR compression algorithm, which is proprietary Distribution of modified unrar sources in separate form or as a part of other software is permitted, provided that it is clearly stated in the documentation and source comments that the code may not be used to develop a RAR (WinRAR) compatible archiver 7-zip Availability: http://www7-ziporg/ AMD Version 22 - AMD Notice: The AMD code was modified Used by permission AMD copyright: AMD Version 22, Copyright 2007 by Timothy A Davis, Patrick R Amestoy, and Iain S Duff All Rights Reserved AMD License: Your use or distribution of AMD or any modified version of AMD implies that you agree to this License This library is free software; you can redistribute it and/or modify it under the terms of the GNU Lesser General Public License as published by the Free Software Foundation; either version 21 of the License, or (at your option) any later version This library is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE See the GNU Lesser General Public License for more details You should have received a copy of the GNU Lesser General Public License along with this library; if not, write to the Free Software Foundation, Inc, 51 Franklin St, Fifth Floor, Boston, MA 02110-1301 USA Permission is hereby granted to use or copy this program under the terms of the GNU LGPL, provided that the Copyright, this License, and the Availability of the original version is retained on all copiesuser documentation of any code that uses this code or any modified version of this code must cite the Copyright, this License, the Availability note, and "Used by permission" Permission to modify the code and to distribute modified code is granted, provided the Copyright, this License, and the Availability note are retained, and a notice that the code was modified is included AMD Availability: http://wwwciseufledu/research/sparse/amd UMFPACK 502 - UMFPACK Notice: The UMFPACK code was modified Used by permission UMFPACK Copyright: UMFPACK Copyright 1995-2006 by Timothy A Davis All Rights Reserved UMFPACK License: Your use or distribution of UMFPACK or any modified version of UMFPACK implies that you agree to this License This library is free software; you can redistribute it and/or modify it under the terms of the GNU Lesser General Public License 3

Advanced Design System 201101 - X-Parameter Generator as published by the Free Software Foundation; either version 21 of the License, or (at your option) any later version This library is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE See the GNU Lesser General Public License for more details You should have received a copy of the GNU Lesser General Public License along with this library; if not, write to the Free Software Foundation, Inc, 51 Franklin St, Fifth Floor, Boston, MA 02110-1301 USA Permission is hereby granted to use or copy this program under the terms of the GNU LGPL, provided that the Copyright, this License, and the Availability of the original version is retained on all copies User documentation of any code that uses this code or any modified version of this code must cite the Copyright, this License, the Availability note, and "Used by permission" Permission to modify the code and to distribute modified code is granted, provided the Copyright, this License, and the Availability note are retained, and a notice that the code was modified is included UMFPACK Availability: http://wwwciseufledu/research/sparse/umfpack UMFPACK (including versions 221 and earlier, in FORTRAN) is available at http://wwwciseufledu/research/sparse MA38 is available in the Harwell Subroutine Library This version of UMFPACK includes a modified form of COLAMD Version 20, originally released on Jan 31, 2000, also available at http://wwwciseufledu/research/sparse COLAMD V20 is also incorporated as a built-in function in MATLAB version 61, by The MathWorks, Inc http://wwwmathworkscom COLAMD V10 appears as a column-preordering in SuperLU (SuperLU is available at http://wwwnetliborg ) UMFPACK v40 is a built-in routine in MATLAB 65 UMFPACK v43 is a built-in routine in MATLAB 71 Qt Version 463 - Qt Notice: The Qt code was modified Used by permission Qt copyright: Qt Version 463, Copyright (c) 2010 by Nokia Corporation All Rights Reserved Qt License: Your use or distribution of Qt or any modified version of Qt implies that you agree to this License This library is free software; you can redistribute it and/or modify it under the terms of the GNU Lesser General Public License as published by the Free Software Foundation; either version 21 of the License, or (at your option) any later version This library is distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE See the GNU Lesser General Public License for more details You should have received a copy of the GNU Lesser General Public License along with this library; if not, write to the Free Software Foundation, Inc, 51 Franklin St, Fifth Floor, Boston, MA 02110-1301 USA Permission is hereby granted to use or copy this program under the terms of the GNU LGPL, provided that the Copyright, this License, and the Availability of the original version is retained on all copiesuser documentation of any code that uses this code or any modified version of this code must cite the Copyright, this License, the Availability note, and "Used by permission" Permission to modify the code and to distribute modified code is granted, provided the Copyright, this License, and the Availability note are retained, and a notice that the code was modified is included Qt Availability: http://wwwqtsoftwarecom/downloads Patches Applied to Qt can be found in the installation at: $HPEESOF_DIR/prod/licenses/thirdparty/qt/patches You may also contact Brian Buchanan at Agilent Inc at brian_buchanan@agilentcom for more information The HiSIM_HV source code, and all copyrights, trade secrets or other intellectual property rights in and to the source code, is owned by Hiroshima University and/or STARC 4

Advanced Design System 201101 - X-Parameter Generator Errata The ADS product may contain references to "HP" or "HPEESOF" such as in file names and directory names The business entity formerly known as "HP EEsof" is now part of Agilent Technologies and is known as "Agilent EEsof" To avoid broken functionality and to maintain backward compatibility for our customers, we did not change all the names and labels that contain "HP" or "HPEESOF" references Warranty The material contained in this document is provided "as is", and is subject to being changed, without notice, in future editions Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this documentation and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or performance of this document or of any information contained herein Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the separate agreement shall control Technology Licenses The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Portions of this product include the SystemC software licensed under Open Source terms, which are available for download at http://systemcorg/ This software is redistributed by Agilent The Contributors of the SystemC software provide this software "as is" and offer no warranty of any kind, express or implied, including without limitation warranties or conditions or title and non-infringement, and implied warranties or conditions merchantability and fitness for a particular purpose Contributors shall not be liable for any damages of any kind including without limitation direct, indirect, special, incidental and consequential damages, such as lost profits Any provisions that differ from this disclaimer are offered by Agilent only Restricted Rights Legend US Government Restricted Rights Software and technical data rights granted to the federal government include only those rights customarily provided to end user customers Agilent provides this customary commercial license in Software and technical data pursuant to FAR 12211 (Technical Data) and 12212 (Computer Software) and, for the Department of Defense, DFARS 252227-7015 (Technical Data - Commercial Items) and DFARS 2277202-3 (Rights in Commercial Computer Software or Computer Software Documentation) 5

Advanced Design System 201101 - X-Parameter Generator 6 X-Parameter Generator Basics 7 Overview 7 Using X-Parameter Generator 7 Limitations 8 Troubleshooting a Simulation 8 X-Parameter Generator Parameters 9 Setting Fundamental Frequencies 9 Reference Signal 10 Setting Up Fundamental Sweeps 11 Setting Up Other Sweeps 11 Setting Up the Initial Guess 12 Selecting a Solver Technique 12 Harmonics, Maximum Mixing Order and X-parameter Maximum Mixing Order 12 Example of X-Parameter Generator 13 NVNA_2port (1 Tone 2 port X-Parameter Generator) 15 NVNA_LoadPull (1 Tone 2 port X-Parameter Generator) 18

Advanced Design System 201101 - X-Parameter Generator X-Parameter Generator Basics This is a description of X-Parameter Generator, including when to use it, how to set it up, the data it generates, and troubleshooting Overview Using the X-Parameter Generator from the Simulation-X_Param palette enables you to obtain the X-parameters of a component, circuit, or subnetwork The extracted X- parameter data can be used as a behavioral model in simulation by using the XnP component For more information, refer to XnP Components (X1P - X10P) (ccsim) Refer to following topics for details on X-Parameter Generator: Using X-Parameter Generator describes the minimum setup requirements for an X- parameter simulation Example of X-Parameter Generator (xparam) gives detailed setups for running a basic X-parameter generation for an amplifier X-Parameter Generator Parameters (xparam) provides details about the parameters available in the X-Parameters controller in ADS Using X-Parameter Generator This section describes how to set up X-Parameter Generator License Requirements The X-Parameter Generator uses the W2305 X-Parameter Generator license You must have this license to run the X-Parameter Generator You can work with examples described here and installed with the software without the license, but you will not be able to simulate them How to Use X-Parameter Generator For a successful analysis: Apply XP_Bias (ccsrc) to DC ports, XP_Source (ccsrc) to large signal input ports, and XP_Load (ccsrc) to outputs Those components are collectively called XP term components and can be found in the Simulation-X_Param palette Check the Num field for each XP term component The X-parameter port numbers are derived from these fields Power sweep at a port has to be specified on the Power source tab of the XP_Source component connected to the port Do not use ParamSweep to sweep source power Load sweep at a port has to be specified on the Load tab of the XP_Load component connected to the port Do not use ParamSweep to sweep load DC bias sweep at a port has to be specified on the DC tab of the XP_Bias component connected to the port Do not use ParamSweep to sweep DC bias Add the X-Parameters controller to the schematic and double-click to edit it For a 7

Advanced Design System 201101 - X-Parameter Generator basic simulation, fill in the fields under the Freq tab: Enter at least one fundamental frequency and the number (order) of harmonics to be considered in the simulation Make sure that frequency definitions are established for all of the fundamentals of interest in a design For example, mixers should include definitions for RF and LO frequencies If more than one fundamental is entered, set the maximum mixing order This limits the number of mixing products to be considered in the simulation For more information on this parameter, refer to Harmonics and Maximum Mixing Order (cktsimhb) If you want to sweep a fundamental, add VarEqn and SweepPlan for the fundamental, then specify the sweep under X-Parameters controller Sweep tab Do not use ParamSweep to sweep fundamentals The setup for parameters Initial Guess tab, Oversample tab and Solver tab is the same as those in Harmonic Balance Simulation (cktsimhb) X-parameter data is written to a dataset file To output X-parameter data to GMDIF file, check the "Output GMDIF file" checkbox GMDIF files are ASCII files and are suitable for cross-platform exchanges Dataset files facilitate Data Display plotting Limitations X-Parameter Generator runs a series of Harmonic Balance simulations So, all limitations to Harmonic Balance also apply to X-Parameter Generator For Harmonic Balance limitation, see Harmonics balance limitations (cktsimhb) Sweeps of the fundamental frequencies have to be defined in the X-Parameters controller under the Sweep tab Do not use ParamSweep to sweep fundamental frequencies Sweeps of other user defined variables like temperature have to be defined in the X- Parameters controller under the Sweep tab Do not use ParamSweep Note Simulation of XnP Components (X1P - X10P) (ccsim) does not support user defined variables Troubleshooting a Simulation For information on troubleshooting, refer to Troubleshooting a simulation in Harmonic Balance (cktsimhb) 8

Advanced Design System 201101 - X-Parameter Generator X-Parameter Generator Parameters ADS provides access to X-Parameter Generator parameters enabling you to define aspects of the simulation listed in the following table: Tab Name Description For details, see Freq Frequencies of fundamentals Setting Fundamental Frequencies Sweep Sweep fundamentals and associated SweepPlans Setting Up Fundamental Sweeps Initial Guess Set parameters related to initial guess Oversample Sets the FFT oversampling ratio Solver Parameters enabling you to choose between a Direct or Krylov solver or an automatic selection The automatic selection is the default and recommended choice, since it allows the simulator to choose the most effective solver for each particular circuit Additional parameters manage memory usage Setting Up the Initial Guess Defining Oversample (cktsimhb) Selecting a Solver Technique Display Control the visibility of simulation parameters on the Schematic Displaying Simulation Parameters on the Schematic (cktsim) Setting Fundamental Frequencies On the Freq tab, you can specify the frequency portion of the simulation The following table describes the parameter details Names listed in the Parameter Name column are used in netlists and on schematics X-Parameter Generator Frequency Parameters Setup Dialog Name Parameter Name Description Fundamental Frequencies Edit Frequency Freq[n] The frequency of the fundamental(s) Change by typing over the entry in the field Select the units (None, Hz, khz, MHz, GHz) from the drop-down list Order Order[n] The maximum order (harmonic number) of the fundamental(s) that will be considered Change by typing over the entry in the field Order[n] is raised to the value of Maxorder if Order[n] for any n is smaller than MaxOrder and there are more than one fundamental frequency The number of harmonics needs to be sufficiently large to represent nonlinear signals (sharp transitions, square waves) An increase in the Order slows down the simulation considerably or results in excessive memory usage Use the Krylov solver if the problem is too big for the Direct solver The lower the Order, the greater the Harmonic Balance truncation error as a 9

Select Maximum mixing order Levels MaxOrder Advanced Design System 201101 - X-Parameter Generator result of the Fourier truncation in the solution representation As a rule of thumb, anything below 5-7 harmonics is unacceptable Using the Manual Convergence Mode (ConvMode=1) and StatusLevel=4 or 5 will give an estimate of this error The computational complexity of the Krylov solver is determined by the size of FFT (ie by the number of samples) With Krylov Harmonic Balance,set Order to 7, 15, 31, etc Keep in mind that according to the Nyquist theorem at least 2 x Order + 1 samples are needed to represent the highest harmonic The Oversample parameter increases the number of samples beyond the minimum by this factor, and, due to the nature of FFT, the number of samples is rounded up to the nearest power of 2 Contains the list of fundamental frequencies Add enables you to add an item Cut enables you to delete an item Paste enables you to take an item that has been cut and place it in a different order The maximum order of the intermodulation terms in the simulation The combined order is the sum of the individual frequency orders that are added or subtracted to make up the frequency list For example, assume there are two fundamentals and Order (see below) is 3 If Maximum mixing order is 0 or 1, no mixing products are simulated The frequency list consists of the fundamental and the first, second, and third harmonics of each source If Maximum mixing order is 2, the sum and difference frequencies are added to the list If Maximum mixing order is 3, the second harmonic of one source can mix with the fundamental of the others, and so on Enables you to set the level of detail in the simulation status report Status level StatusLevel Prints information about the simulation in the Status/Summary part of the Message Window <\BR>-0 reports little or no information, depending on the simulation engine -1 and 2 yield more detail - Use 3 and 4 sparingly since they increase process size and simulation times considerably The type of information printed may include the sum of the current errors at each circuit node, whether convergence is achieved, resource usage, and where the dataset is saved The amount and type of information depends on the status level value and the type of simulation Reference Signal The Large Signal Operating Point (LSOP) for X-parameters is always defined with one reference signal per fundamental frequency In order to enforce time invariance and avoid duplicate measurements, the phase of this reference signal is defined to be zero and is never swept A message is displayed on the status window indicating which signal was chosen as the reference signal To understand why a reference signal is needed, consider a simple LSOP consisting of one large tone at a single frequency A large signal AM/AP with magnitude M and phase P is simply a time-delayed version of a large signal AN with magnitude M and phase 0 Time invariance principle states that the response to AM/AP should be exactly the same as the time-delayed response to AN, so there is no need to store X-parameters for both sets of 10

Advanced Design System 201101 - X-Parameter Generator stimulus Instead the X-parameters are always measured at phase 0, and the simulation of XnP Components (X1P - X10P) (ccsim) uses time invariance to predict the response to phase-shifted (or time-delayed) signals Selection of the reference signal(s) during X-parameter generation and while using X- parameter files with such reference data are both handled internally by the ADS simulator and requires no input from you Setting Up Fundamental Sweeps On the Sweep tab, setting up the sweep portion of the simulation consists of two basic parts: Selecting the sweep type and setting the associated characteristics Optionally, specifying a sweep plan To shorten simulation time in any parameter sweep, select a start point as close as possible to the convergence point and vary the parameter gradually This yields better estimates for the next simulation, and achieves convergence more rapidly than if the parameter were changed abruptly The following table describes the parameter details Names listed in the Parameter Name column are used in netlists and on schematics X-Parameter Generator Sweep Parameters Setup Dialog Name Parameter to sweep Parameter Name FreqSweep Description The name of the fundamental variable to be swept The fundamental variable needs to be defined in VarEqn Sweep plan FreqSweep The name of an existing sweep plan which is used for the fundamental variable to be swept Enter the name of the plan or select it from the dropdown list Select Contains the list of fundamental sweeps Double-click in the Edit field to add fundamental sweeps to this window Add enables you to add an item Cut enables you to delete an item Paste enables you to take an item that has been cut and place it in a different order Setting Up Other Sweeps Power, DC bias and Load sweeps desired in X-parameter generation have to be set in XP_Source (ccsrc), XP_Bias (ccsrc) and XP_Load (ccsrc) components Do not use ParamSweep components for those sweeps All the sweeps are defined as nested sweeps Therefore, the total number of sweep points established in all of the XP_Source (ccsrc), XP_Bias (ccsrc) and XP_Load (ccsrc) components is the product of the number of points in the individual sweeps Furthermore, the Power and Load sweeps may require setting up two sweeps, as they are complex variables For example, sweeping the magnitude of a power source with 11 points, DC bias voltage with 5 points, and a Load impedance with 6 11

Advanced Design System 201101 - X-Parameter Generator magnitude values and 36 phase values will result in 11,880 of total sweep points If the total number of sweep points is very large, you can expect long simulation time needed for the X-parameter generation The progress of the generation process is shown at the bottom of the status window as the percentage of already handled sweep points Setting Up the Initial Guess On the Initial Guess tab, you can set up the initial guess for X-Parameter Generator The settings on the Initial Guess tab are similar to those of a Harmonic Balance controller Initial Guess tab See Setting Up the Initial Guess in Harmonic Balance (cktsimhb) Selecting a Solver Technique The Solver tab enables you to select a Direct or Krylov solver, or to allow the simulator to assign one automatically The settings on the Solver tab are identical as those of a Harmonic Balance controller See Selecting a Harmonic Balance Solver Technique (cktsimhb) Harmonics, Maximum Mixing Order and X-parameter Maximum Mixing Order With multiple sources in a circuit, mixing products will occur For more information, refer to Harmonics and Maximum Mixing Order in Harmonic Balance (cktsimhb) The maximum harmonic indices sent to the X-parameter file are governed by a different parameter, as shown in the following table This behavior is somewhat different from the harmonic balance simulation, particularly in the single-tone setup The parameters "Order" and "MaxOrder" take effect for the HB simulation invoked for the X-parameter generation, but they are ignored for the data output The highest harmonic indices, including mixing terms to be sent to the X-parameter file are exclusively controlled by the parameter "XParamMaxOrder" listed in the following table, and available for editing on screen X-Parameter Generator MaxOrder Parameters Setup Dialog Name Parameter Name Description XParamMaxOrder The maximum order of the X-parameters to be sent to the X-parameter data file For a single tone X-parameter generation, XParamMaxOrder must not exceed the Order of the fundamental For multi-tone generation, the value must not exceed MaxOrder specified under Freq tab To set the parameter value, enable the parameter display under Display tab Edit the parameter value on the schematic The default value is 4 12

Advanced Design System 201101 - X-Parameter Generator Example of X-Parameter Generator This section gives detailed setups to perform an X-parameter generation with a fundamental frequency sweep This example workspace can be found in the ADS Examples directory under Tutorial/X_parameters_Generation_wrk The following figure illustrates the setup for X-parameter generation 1 From Simulation-X_Param palette, select an XP_Source component and connect its "+" node to the input port of the circuit Connect GROUND to the "-" node Edit the component to set these values: 1 Port Number = 1 2 Port Name = "Input" 3 Reference impedance as default 50+j*0 Ohm 4 Select DC tab, then select Bias type as None 5 Select Power source tab and set the following parameters: 1 Set Frequency harmonic indices to 1 2 Select Sweep type as Use sweep 3 Set Mag as Start = -20 dbm Stop = 5 dbm Num of pts = 26 6 Click Ok to close the component dialog 13

2 3 4 5 6 7 8 Advanced Design System 201101 - X-Parameter Generator From Simulation-X_Param palette, select an XP_Load component and connect its "+" node to the output port of the circuit Connect GROUND to the "-" node Edit the component to set these values: 1 Port Number = 2 2 Port Name = "Output" 3 Reference impedance as default 50+j*0 Ohm 4 Ensure DC tab is selected, then select Bias type as None 5 Select Load tab and set the following parameters: 1 Select Load type as Impedance 2 Set Frequency harmonic indices to 1 3 Select Format as Mag/Phase 4 Select Sweep type as Single point 5 Set Mag = 50 Ohm 6 Click Ok to close the component dialog From Simulation-X_Param palette, select an XP_Bias component and connect its "+" node to the DC port of the circuit Connect GROUND to the "-" node Edit the component to set these values: 1 Port Number = 3 2 Port Name = "VDC bias" Place a VarEqn on the schematic, add a Var fund_1 = 10e9 From Simulation-X_Param palette, select and place a SweepPlan component SwpPlan1 on the schematic Edit the component to set these values: 1 Start = 10e9 2 Stop = 14e9 3 Step = 01e9 From Simulation-X_Param palette, select and place an X-Parameters controller on the schematic Edit the controller as: 1 Enable the Output GMDIF file checkbox, specify the output GMDIF file name as "xparam_testxnp" 2 Select Freq tab and set Frequency = 1, Order = 15 3 Select Sweep tab and set Parameter to sweep = fundfreq, select SwpPlan1 from the SweepPlan dropdown list, click Add button 4 Click OK button to close the component edit dialog Save the design as xparam_test Simulate When the simulation is finished, X-parameter data is written to xparam_test and xparam_testxnp in the data subdirectory 14

Advanced Design System 201101 - X-Parameter Generator NVNA_2port (1 Tone 2 port X- Parameter Generator) Symbol Parameters 15

Advanced Design System 201101 - X-Parameter Generator Name Description Units Default Port number (or Num) Order Fund_Start Port number 1 and 2 are used internally None 1 and 2 The maximum order (harmonic number) of the fundamental that will be considered Fundamental frequency sweep start (also used for single value), numerical value only None 5 Hz 1 GHz Fund_Stop Fundamental frequency sweep stop, numerical value only Hz 1 GHz Fund_NumPts number of points for fundamental frequency sweep, numerical value only XParamMaxorder The maximum order of the X-parameters to be sent to the X- parameter file None 1 None 3 GmdifEnabled Enable writing the GMDIF file None No GmdifFile Name of the GMDIF file (extension xnp) None FileNamexnp LS_SwpType Sweep type for large signal power at port 1: Single point, Use sweep None Single point LS_Start LS_Stop Start power level at port 1, in dbm, for power sweep (also used for single value), numerical value only Stop power level at port 1, in dbm, for power sweep, numerical value only dbm -20 dbm -10 LS_NumPts Number of points for power sweep at port 1, numerical value only None 2 DC_Mode_1 DC bias mode at port 1: None, Voltage, Current None "None" DC_SwpType_1 Sweep type for DC bias at port 1: Single point, Use sweep None Single point DC_Start_1 DC_Stop_1 Start bias level, in V or A depending on DC_mode_1, for DC sweep at port 1 (also used for single value), numerical value only Stop bias level, in V or A depending on DC_mode_1, for DC sweep at port 1, numerical value only DC_NumPts_1 Number of points for DC sweep at port 1, numerical value only None 2 DC_Mode_2 DC bias mode at port 1: None, Voltage, Current None "None" DC_SwpType Sweep type for DC bias at port 2: Single point, Use sweep None Single point DC_Start_2 DC_Stop_2 Start bias level, in V or A depending on DC_mode_2, for DC sweep at port 2 (also used for single value), numerical value only Stop bias level, in V or A depending on DC_mode_2, for DC sweep at port 2, numerical value only DC_NumPts_2 Number of points for DC sweep at port 2, numerical value only None 2 Notes/Equations V or A V or A V or A V or A 3 4 3 4 1 2 3 4 5 This component is designed for one-tone two-port X-Parameter Generator to establish frequency, power and DC sweeps for the large signal operating conditions For more information, refer to X-Parameter Generator Basics (xparam) There can be only one NVNA component (NVNA_2port or NVNA_LoadPull) instance per design Port Number 1 and 2 are used internally by the component Num 1 and 2 cannot be used by any other XTerm (XP_Source, XP_Load or XP_Bias ) component placed on the schematic The reference impedance for both port 1 and port 2 is 50 Ohm Port 1 is input port and port 2 is output port Both Port 1 and Port 2 are terminated with 50 Ohm When Fund_Start, Fund_Stop and Fund_NumPts are all specified, frequency sweep is performed When any of Fund_Stop and Fund_NumPts is not specified, Fund_Start is 16

6 7 8 Advanced Design System 201101 - X-Parameter Generator used for extraction at a single frequency point When *_SwpType is Single point, *_Start is used as single value This component must not interact with external sweeps For that reason all the values (start, stop, num of pts) must not be defined via external variables In order to provide a good coverage at all power levels, power sweep is performed in both logarithmic and linear scales So the total number points for power sweep is 2*LS_NumPts-2 17

Advanced Design System 201101 - X-Parameter Generator NVNA_LoadPull (1 Tone 2 port X- Parameter Generator) Parameters Name Description Units Default Port number (or Num) Order Fund_Start Port number 1 and 2 are used internally None 1 The maximum order (harmonic number) of the fundamental that will be considered Fundamental frequency sweep start (also used for single value), numerical value only 18 None 5 Hz 1 GHz Fund_Stop Fundamental frequency sweep stop, numerical value only Hz 1 GHz Fund_NumPts number of points for fundamental frequency sweep, numerical value only XParamMaxorder The maximum order of the X-parameters to be sent to the X- parameter None 1 None 3 GmdifEnabled Enable writing the GMDIF file None No GmdifFile Name of the GMDIF file (extension xnp) None FileNamexnp LS_SwpType LS_Start LS_Stop LS_NumPts Sweep type for large signal power at port 1: Single point, Use sweep Start power level at port 1, in dbm, for power sweep (also used for single value), numerical value only Stop power level at port 1, in dbm, for power sweep, numerical value only Number of points for power sweep at port 1, numerical value only None dbm -20 dbm -10 None 2 Single point DC_Mode_1 DC bias mode at port 1: None, Voltage, Current None "None" DC_SwpType_1 Sweep type for DC bias at port 1: Single point, Use sweep None Single point DC_Start_1 DC_Stop_1 Start bias level, in V or A depending on DC_mode_1, for DC sweep at port 1 (also used for single value), numerical value only Stop bias level, in V or A depending on DC_mode_1, for DC sweep at port 1, numerical value only V or A V or A 3 4

Advanced Design System 201101 - X-Parameter Generator DC_NumPts_1 Number of points for DC sweep at port 1, numerical value only None 2 DC_Mode_2 DC bias mode at port 1: None, Voltage, Current None "None" DC_SwpType_2 Sweep type for DC bias at port 2: Single point, Use sweep None Single point DC_Start_2 DC_Stop_2 Start bias level, in V or A depending on DC_mode_2, for DC sweep at port 2 (also used for single value), numerical value only Stop bias level, in V or A depending on DC_mode_2, for DC sweep at port 2, numerical value only DC_NumPts_2 Number of points for DC sweep at port 2, numerical value only None 2 GammaMag_SwpType GammaMag_Start GammaMag_Stop Sweep type for magnitude of gamma-load at port 2: Single point, Use sweep Start value for magnitude of gamma-load at port 2 (also used for single value), numerical value only Stop value for magnitude of gamma-load at port 2, numerical value only GammaMag_NumPts Number of points for magnitude of gamma-load at port 2, numerical value only GammaPhase_SwpType Sweep type for phase of gamma-load at port 2: Single point, Use sweep GammaPhase_Start GammaPhase_Stop GammaPhase_NumPts Notes/Equations Start value for phase of gamma-load at port 2 (also used for single value), numerical value only Stop value for phase of gamma-load at port 2, numerical value only Number of points for phase of gamma-load at port 2, numerical value only V or A V or A None 3 4 None 0 None 01 None 2 None None 0 None 30 None 2 Single point Single point 1 2 3 4 5 6 7 8 This component is designed for one-tone two-port X-Parameter Generator to establish power and DC sweeps for the large signal operating conditions Load sweep can be performed at port 2 For more information, refer to X-Parameter Generator Basics (xparam) There can be only one NVNA component (NVNA_2port or NVNA_LoadPull) instance per design Port Number 1 and 2 are used internally by the component Num 1 and 2 cannot be used by any other XTerm (XP_Source, XP_Load or XP_Bias ) component placed on the schematic The reference impedance for both port 1 and port 2 is 50 Ohm Port 1 is input port and port 2 is output port When Fund_Start, Fund_Stop and Fund_NumPts are all specified, frequency sweep is performed When any of Fund_Stop and Fund_NumPts is not specified, Fund_Start is used for extraction at a single frequency point When *_SwpType is Single point, *_Start is used as single value This component must not interact with external sweeps For that reason all the values (start, stop, num of pts) must not be defined via external variables In order to provide a good coverage at all power levels, power sweep is performed in both logarithmic and linear scales So the total number points for power sweep is 2*LS_NumPts-2 19