MagPro coils. Versatility in Magnetic Stimulation. For Clinical and Research use

Similar documents
MAGNETIC STIMULATION. Accessories Catalogue

Human Subjects in fmri Research

12/26/2017. Alberto Ardon M.D.

Neural Function Measuring System MEE /32 ch Intraoperative Monitoring System

Potential Risks of MRI in Device Patients

FEASIBILITY STUDY AND PROTOTYPING OF AN ELECTROMAGNETIC CORTICAL STIMULATOR FOR BRAIN MAPPING IN OPEN SKULL NEUROSURGERY

Generator Users Group Annual Conference Core testing, low and high flux, tap. Mladen Sasic, IRIS Power

Designing an MR compatible Time of Flight PET Detector Floris Jansen, PhD, Chief Engineer GE Healthcare

Biomechatronic Systems

Biomechatronic Systems

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

INTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection

Metal Detector Search Coil 101

Bearing Currents. Introduction. What are Bearing Currents? Application Note AP040061E Effective January 2014

DT 9818 Waveform-Generator. Hardware Trigger Version. Operating Manual. Version 2.0. May Page 1 of 21

Leksell Neuro Generator

is designed from the ground up for an exceptional sensory experience for both YOU and YOUR patients.

Analysis of magnetic and electromagnetic field emissions produced by a MRI device

SKYBOX. 5-channel Digital EMG, NCS and EP System

Eddy Current Testing (ET) Technique

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output

DIATHERMY UNITS HIGH FREQUENCY HEAT THERAPY:

Power Amplifiers. Power with Precision

BEYOND HEAT. Therapeutic Effectiveness Repeatability Safety.

AP PSYCH Unit 4.2 Vision 1. How does the eye transform light energy into neural messages? 2. How does the brain process visual information? 3.

Syllabus Recording Devices

NATIONAL SENIOR CERTIFICATE GRADE 12

MAGNETIC RESONANCE IMAGING

TRANSFORMER OPERATION

Acoustic noise reduction of MRI systems by means of magnetic shielding

Current Probes. User Manual

Alternating Current. Slide 1 / 69. Slide 2 / 69. Slide 3 / 69. Topics to be covered. Sources of Alternating EMF. Sources of alternating EMF

Alternating Current. Slide 2 / 69. Slide 1 / 69. Slide 3 / 69. Slide 4 / 69. Slide 6 / 69. Slide 5 / 69. Topics to be covered

Metal Detector Description

TSA 6000 System Features Summary

Psychology in Your Life

577 nm: The Preferred Wavelength

Realisation of the galvanic isolation in customer-end DC to AC inverters for the LVDC distribution

Exercise 3-2. Cross-Polarization Jamming EXERCISE OBJECTIVE

from signals to sources asa-lab turnkey solution for ERP research

May 2014 Group 9 Variable Coil Helmet System for Transcanial Magnetic Stimulation (TMS)

Fig. 1

Technical Specification

RECENT ADVANCEMENTS IN THE APPLICATION OF EMATS TO NDE

Treatment WD Pulse Application for Transcranial Magnetic Stimulation

Mobile demagnetizer MM DM-P / -PC (large objects, pipes, bars, stock)

5.0 THREE PHASE SYSTEM

2018 Buyers Guide to Pulsed Magnetic Therapy

Active induction balance method for metal detector sensing head utilizing transmitterbucking and dual current source

A SYSTEM FOR THE ADVANCE WARNING OF RISK OF LIGHTNING. John Chubb and John Harbour

Laser Source. Photonic Power Module (PPM) Assembly Drawing. Key Features: Applications:

Electromagnetic Compatibility

Laser User Manual. Therapy Unit INTRODUCTION

ADDMAS CORIOLIS MASS FLOW METER

QUESTION BANK ETE (17331) CM/IF. Chapter1: DC Circuits

Motoplat CV-014DS TESTER FOR DIAGNOSTICS OF ALTERNATOR STATOR WINDINGS AND DIODE BRIDGES USER MANUAL

Walchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer

1 Introduction. 2 The basic principles of NMR

1. What are the components of your nervous system? 2. How do telescopes and human eyes work?

INTRODUCTION. Have applications for imaging, detection and navigation.

Feeding human senses through Immersion

ECE2019 Sensors, Signals, and Systems A Lab #6: Electromagnetic Field Sensing

MC-370CE - Soco Cold Saw, Includes Stand 100 x 100mm Rectangle Capacity Dual Speed 22 / 44rpm & Self Centring Vice & CE Approved Guarding

ELG3336 Design of Mechatronics System

Interference. Lecture 22. Chapter 21. Physics II. Course website:

MRI SYSTEM COMPONENTS Module One

Sheep Eye Dissection

Magnetic field measurements, Helmholtz pairs, and magnetic induction.

ensory System III Eye Reflexes

EPSITRON Electronic Circuit Breakers Compact and Precise ECBs for DC Circuits

FISCHER CUSTOM COMMUNICATIONS, INC.

COUPLED SECTORIAL LOOP ANTENNA (CSLA) FOR ULTRA-WIDEBAND APPLICATIONS *

:: Slide 1 :: :: Slide 2 :: :: Slide 3 :: :: Slide 4 :: :: Slide 5 :: :: Slide 6 ::

9/28/2010. Chapter , The McGraw-Hill Companies, Inc.

EYE STRUCTURE AND FUNCTION

3-PHASE EMI/RFI FILTERS

ABRASIVE CUTTING METACUT 302

Main features. System configurations. I Compact Range SOLUTION FOR

Analysis of static and time-variable magnetic fields

lighting your creativity HONEY BADGER 320Ws Digital Flash Instruction Manual

High Power Laser Delivery Assemblies COPPER FERRULE PVC COVERED SST MONOCOIL. fiberguide ANODIZED ALUMINUM HEATSINK AIRGAP TECHNOLOGY - NO EPOXY

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

Investigation of a Voltage Probe in Microstrip Technology

New developments in near-field acoustic holography

FRAUNHOFER INSTITUTE FOR INTEGRATED CIRCUITS IIS. MANUAL PANORAMIC MICROSCOPY WITH istix

LCP Pilon Plate 2.7/3.5

MAGSTIM P/N OPERATING MANUAL

16. Sensors 217. eye hand control. br-er16-01e.cdr

Microwave and optical systems Introduction p. 1 Characteristics of waves p. 1 The electromagnetic spectrum p. 3 History and uses of microwaves and

HW- Finish your vision book!

ServoStep technology

High Power Laser Delivery Assemblies COPPER FERRULE PVC COVERED SST MONOCOIL. fiberguide AIRGAP TECHNOLOGY - NO EPOXY

Advanced, accurate and intelligent monitoring for your transformer

Touch. Touch & the somatic senses. Josh McDermott May 13,

TEPZZ 6Z7 A_T EP A1 (19) (11) EP A1. (12) EUROPEAN PATENT APPLICATION published in accordance with Art.

ULTRASTAB I U Precision

Eye. Eye Major structural layer of the wall of the eye is a thick layer of dense C.T.; that layer has two parts:

Vibrotactile Apparent Movement by DC Motors and Voice-coil Tactors

Infocal 9 Energy calculator

Human-to-Human Interface

Transcription:

MagPro coils Versatility in Stimulation V For Clinical and Research use

Selection Criteria for Stimulating Coils 2 Large, or Small Coils circular or figure of 8? Large coils provide a high penetration depth, but are not very focused. The small coils are more focused, but have a relatively shallow penetration depth. Thus there is an inverse relation between penetration depth and focus.the coils come in many sizes and shapes. The two most commonly used coils are the circular shaped coil and the butterfly shaped coil also known as the figure of 8 coil. Circular or Parabolic Coils Butterfly Coils The Butterfly coils are more focused in comparison with the circular coils. The two windings are placed side-by-side or overlapping, enabling the coil to stimulate structures with focus right under its center. The butterfly coil is useful in focused stimulation. List of s standard coils with basic facts. More detailed informations at www.magventure.com When applying the circular or parabolic coil, the induced current in the tissue occurs under the windings. A fairly large area of body tissue will be stimulated. The circular or parabolic coil may be positioned conveniently over many parts of the body, and usually serves well as a general purpose coil. MC-125 Circular Coil 114 mm 41 kt/s 450 pulses General Purpose, Phrenic nerve roots, Motor Cortex C-100 Circular Coil Built-in amplitude control 110 mm 35 kt/s 400 pulses General Purpose, Phrenic nerve roots, Motor Cortex MMC-140 Parabolic Coil 120 mm 33 kt/s 650 pulses General Purpose, MMC-140-II Parabolic Coil Built-in amplitude control 126 mm 33 kt/s 650 pulses General Purpose, gvg

3 MC-B35 2 x 45 mm 50 kt/s 75 pulses High focus stimulation Low penetration depth MC-B70 Bend outer windings provide +10% power 2 x 97 mm 31 kt/s 400 pulses Foc. Stimulations,, C-B60 Built-in amplitude control 2 x 75 mm 35 kt/s 350 pulses Foc. Stimulations, D-B80 120 angled 2 x 80 mm 31 kt/s 350 pulses Foc. Stimulations, MC-B65-HO 2 : 2m cable 8 : 8m cable Orthogonal handle 2 x 75 mm 35 kt/s 350 pulses Foc. Stimulations, RT-120 Elliptic coil (racetrack coil) Inner loop ø30x110mm Outer loop ø80x160mm 31 kt/s 1500 pulses General Purpose Bigger muscles Spinal nerves RT-120-II Elliptic coil (racetrack coil) with built in amplitude control. Inner loop ø30x110mm Outer loop ø80x160mm 31 kt/s 1500 pulses General Purpose Bigger muscles Spinal nerves

4 F coils Static cooled coils Static cooled coils. To prevent fast overheating during use we developed the static cooled F-series of coils. The fluid absorbes dissipated energy thus enabling more stimulis. MCF-75 Small circular Coil Static fluid Cooling 65 mm 43 kt/s 500 pulses, Motor Cortex MCF-125 Standard circular Coil Static fluid Cooling 120 mm 34 kt/s 2000 pulses Train stimulation, Brain tissue, MCF-B65 Static fluid Cooling 2 x 75 mm 32 kt/s 2000 pulses Train stimulation, Brain tissue, Dynamic cooled coils Coils with external cooling When the highest number of stimulations are required dynamic cooling is required. The cool unit in combination with the Cool-B65 coil are the solution if a long duration and high stimulation output is required. Cool unit required for Cool-B65 coil. Cool-B65 Dynamic fluid Cooling 2 x 75 mm 36 kt/s 20000 pulses Train protocols, Long train stimulation, Brain tissue, V

5 Placebo coils placebo coils are geometrical identical with the corresponding normal coils. Placebo coil are intended for blind testing and have considerable lower magnetic fields than the normal coils. MC-P-B70 Placebo Coil 2 x 100 mm field attenuation > 80% 400 pulses Placebo version of MC-B70 MC-P-B65 Placebo Coil 2 x 75 mm field attenuation > 80% 1600 pulses Placebo version of MCF-B65 Special coils develops special coils for special purposes. Many coils have been developed. Examples MRi-B88 for use in MR scanners and the Twin Coil for Seizure Therapy (together with the special MagPro MST stimulator) Custom designed coils Besides our standard coils we manufactures custom designed coils based on specifications from our customers. gvg

6 General coil features. All coils are designed for use with Magpro R30, X100, R30 with option, X100 with option and R100. Coils with build in power control in the coil handle and trigger button in the handle can also be used with a MagPro Compact. (coil C-100, C-B60, RT 120-II and MMC-140-II) Coils without built in power control and trigger button requires the coil converter when connected to a MagPro Compact. Additional accessories Accessories such as Remote control, MEP monitor, Cable for external trig, Flexible arm, Flight case for the MagPro, Magare also supplied by. Please see on www.magventure.com for further Probe, 110/230V power supply for the MagPro etc. details. North America Please note that not all coils are cleared for sale by FDA in the US. For further details of which are cleared in the US, please contact local distributor #5426 www.danske-ideselskab.dk VERSATILITY IN MAGNETIC STIMULATION Lucernemarken 15 DK-3520 Farum Denmark Phone: +45 4499 8444 Fax: +45 4439 0449 E-mail: info@magventure.com www.magventure.com