SECTION (10670) - WIRE CLOSET AND UTILITY SHELVING

Similar documents
SECTION (10670) - WIRE CLOSET AND UTILITY SHELVING

WIRE SHELVING. Joiner Plate -6667, 6687, Item Description " Shelf & Rod " Shelf & Rod

Adjustable Countertop Installation

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

MONKEY BARS OVERHEAD RACK INSTALLATION

Testing. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified.

SECTION PRE-MANUFACTURED CABINETS

AUXILIARY FRAMING AND ACCESSORIES

Ready To Go SimpleSpec tm. Installation Manual. For more information, please visit 3-form.com or call

Thanks for shopping with Improvements! Deluxe 10 Closet Organizer (12 deep) Item #461609

Mounting Brackets for 8450 Drawer Slides KV Front Bracket 20 $1.30 KV P Rear Bracket 20 $5.20

Assembly and Installation Guide

PRODUCT INFORMATION Penco Wide-Span Shelving

Installation Instructions

Design and Construction Standards SECTION ATHLETIC LOCKERS

Music Area Casework General 1.01 Summary Related Sections Definitions Qualifications and Quality Assurance

SECTION CARPENTRY

SECTION HOLLOW METAL DOORS AND FRAMES

TIP FOR GETTING STARTED

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION METAL LOCKERS

Walk-in Configurations

PRE-ENGINEERED HORSE STALL SYSTEMS SDFD SLIDING DOOR c/w FOLD-DOWN GRILL. & Assembly. Installation Instructions

MANUFACTURING INC. Specifications

1.1 RELATED DOCUMENTS

CSI Section DMI Light Gage Structural Steel Framing Systems. Blocking Fire Rated Pre-cut (Proprietary) Furring Wall Preservative Treated

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

LPR System Installation instructions

SECTION 19: Endwood Fusion Welded Gate Installation Guide

SLATTEX (Textured Slatwall) INSTALLATION GUIDE

TS-20KD-1010 LOW PROFILE CARGO SCALE INSTALLATION GUIDE

AIA Specification. Section Slate Shingles PART 1 GENERAL

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

ACORNWIRE.COM MESH PARTITIONS DIVISION 10 - SPECIALTIES WIRE MESH PARTITION FOLDING GATE

Installation Instructions

JURALCO ALUSTORE MODULAR STORAGE SYSTEM. Modular Storage System. Issue 1/16 ISSUE 1/16. ph (09)

SECTION PVC THATCH SHINGLE ROOFING SYSTEM PART 1 GENERAL 1.01 SUMMARY

INSTALLATION INSTRUCTIONS

Woven Steel Wire Fence Type-47. Under the state specification for fencing, ASTM A 116 is called out.

Product Guide Specification

In addition to this general mounting and adjustment instruction you need the fitting specification document, where the individual drilling dimensions

Leveling System Solutions

ULT R A S PACE SAV E R SQ UA R E D

Training Manual. SCHULTE freedomrail Training Manual Page 1

Parveneer Positive Pressure Fire Rated Frames Double rabbet with T stop for 20 minutes

Mounting Instructions Item No.: /521/522/420/421/422

1. Layout. Step 1. Step 2. Step 3. Fig. 1

Installation Instructions for. Handrail Component System

INSTALLATION INSTRUCTIONS

Project: # Solano Community College District

PRE-ENGINEERED HORSE STALL SYSTEMS 4884 HSD STANDARD SLIDING DOOR. & Assembly. Installation Instructions

Shelf Converter Drawer System

Extra Wide Designer Lockers Series Installation Instructions

INSTALLATION INSTRUCTIONS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Tufftec Lockers Specifications & Drawings SPECIFICATIONS & DRAWINGS

4. Metal roof jacks at penetrations and attachments

Worktop INDEX eight Capacity Unpacking

9 X 12 FIXED TYPE ALUMINUM WINDOW BARS INSTALLATION INSTRUCTIONS Import Note : 9 X 12 Spacing Fixed Type Installation is covered in this Instruction.

Log Siding J Block. Outlet J Block 4 3/4 x 7. Fixture J Block 7 x 7

Box Edge Plus Steel Shelving Installation Instructions

INSTALLATION INSTRUCTIONS

LA-1010 User s Manual 3 in 1 Stud/Metal/AC Voltage Finder With Laser Line Level.

Tuxedo Console Table INSTALLATION INSTRUCTIONS P73037, P73038, P _2_B Page 1 of 5

A. Columns: Worthington Millwork; Cellular Polyvinyl Chloride (PVC) columns; decorative, weatherproof, insect-proof, and highly durable.

SECTION FOLDING GLASS PANEL PARTITIONS

ULT R A SPAC E SAV E R

Alexandra Secondary College Refurbishment Project No: 1507 SECTION MANUFACTURED CASEWORK - SHOP BUILT 12300/1

Lunette Series. Home Theater Curved Fixed Frame Projection Screen. User s Guide. Important Safety and Warning Precautions

TYPE "B" GAS VENT. Do not connect gas vent to a solid or liquid fuelled appliance or any appliance requiring a chimney.

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

SECTION BULLET- RESISTANT DOORS

Assembly Instructions

WADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains.

TOGGLER Specialty Anchors

Coordinate installation of rough carpentry members specified in other sections.

B. Bidders shall acknowledge receipt of this Addendum in writing on his Proposal Form.

Linear Open Style Suspended Ceiling Installation Guide

C-Series & S-Series Classic Frame with Transom (Single or Pair)

MPA-9000 Universal Ceiling Projector Mount Kit

DIVISION 6 WOOD, PLASTICS AND COMPOSITES

System 3000 specifications

FT DIX ELEMENTARY SCHOOL PHASE VII, CLASSROOM ADDITION PEMBERTON TOWNSHIP REGAN YOUNG ENGLAND BUTERA, PC PROJECT #5349A

Panel & Shelf Identification

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

Chapter 19. Interior Finish Work

Chapter 23. Garage Construction

Worktop. Weight Capacity. 100 lbs. 21 Corner Worktop. 48 Worktop. Fits over 2 Cabinets. 72 Worktop. Fits over 3 Cabinets. 200 lbs. 150 lbs.

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

PLM CABINET AND MTL LIGHT INSTRUCTIONS

Swerve Rack CUSTOM RACKS AVAILABLE

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

Before Assembling the Storage Wall

LOCKER SPECIFIERS GUIDE. The standard of excellence for business, industry and institutions. Lockers Cabinets Shelving

DIY STEP-BY-STEP INSTALLATION GUIDE (PAGE 12) Create your space.

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

Assembly Instructions Music Library System

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

Transcription:

SECTION 10 57 23.13 (10670) - WIRE CLOSET AND UTILITY SHELVING PART 1 GENERAL 1.01 SUMMARY 1. Wire Closet Shelves B. Related Sections: 1. Section 06 10 00 (06100) - Rough Carpentry 1.02 QUALITY ASSURANCE A. Installer Qualifications: Manufacturer's authorized representative who is trained and approved for installation of units required for this Project. B. Source Limitations: Obtain metal storage shelving through one source from a single manufacturer. 1.03 DELIVERY, STORAGE, AND HANDLING A. Deliver storage shelving palleted, wrapped, or crated to provide protection during transit and Project-site storage. 1.04 PROJECT CONDITIONS A. Environmental Limitations: Do not deliver or install metal storage shelving until spaces are enclosed and weatherproof, wet work in spaces is completed and dry, and ambient temperature is being maintained at the levels indicated for Project when occupied for its intended use. PART 2 PRODUCTS 2.01 WIRE CLOSET SHELVES A. Approved Manufacturers: 1. Lifetime Ventilated Series Shelf with Hanging Rod ; Organized Living (888-674-5484) B. Components: 1. Structural Performance: a. Structural Performance: Back clips spaced 11 inches with support braces at 3 feet 6 inches. b. Static Load: 75 lb/ft of shelf minimum. c. For heavy duty applications in pantry and garage applications space support brace on 2 feet. d. Back Clips and Down Back Clips shall be Tri-Loc II Patented hollow wall anchoring system. 2. Material: Minimum requirements. a. Steel Rod: Grade C 1008 cold drawn steel rod. Tensile strength of 100 ksi. b. Front Rods and Studs: 0.306 inch diameter. c. Back Rods: 0.243 inch diameter. d. Cross Wire Spacing: 1 inch spacing. 0.120 inch diameter for one inch spaced standard 20 inches shelf. 0.105 inch diameter for one inch spaced standard mesh shelf. PAGE 1

REVISED: 09/03/13 e. Cross Wire Spacing: 1/2 inch spacing. 0.0915 inch diameter for one-half inch spaced tight mesh shelf. 3. Shelving: a. Hanging Shelf with Open Slide: 12 inches deep by length as shown on Drawings. b. Storage Shelf: 12 inches deep by length as shown on Drawings. 4. Mounting Hardware: Manufacturer's standard components including anchor clips, end brackets, angled support braces and end caps, including the following: C. Finish: a. Side Wall Bracket: As required. Shelf side wall interface. b. Support Brace: Maximum 42 inches and every open end Anchor Back Clips. c. Fasteners, clips, caps and touch-up all as required. d. Down Back Clips. 1. Electrostatic applied oven cured epoxy at all surfaces to 3 to 5 mil thickness. a. Color: Pure White D. Configurations: 1. King Guestroom Wire Shelves: (Drawing A410) 2. Accessible King Guestroom Wire Shelves: (Drawing A 411) a. Two (2) shelves to be provided full width of closet mounted at 48 and 58 inches above finished floor. Hanging rod to be located under open section of bottom shelf. b. Three (3) additional 12 wide stacked shelves located to one side of closet below bottom shelf. 1) Storage Shelves to be located at the following intervals: 12, 24, and 36. 2) Shelf Depth: 12 inches. c. Parts List: The following is a parts list for this configuration. List shall be verified by Closet 1 (Up to 30 Wide) PAGE 2 FILE: 10-105723_13-C-Wire Closet And Utility Shelving CFRST SPECMSTR-NEW BUILD 2013, Marriott International, Inc.

(3) 2 1210-1212-11 12" D Storage Shelf - White (1) 3 1210-1212-11 12" D Storage Shelf - White 12 1430-6620-11 Versa-Clip w/ Tri-Loc II Anchor - White 7 1430-6621-11 Side Wall Bracket w/tri-loc II Anchor - White 5 1430-6665-11 Adjustable Pole Clip- White 2 1430-6671-11 Base Cap - White 1 1430-6672-11 70" Support Pole- White 28 1430-6693-11 Medium End Cap - White 12 1430-6694-11 Large End Cap - White 3. Extended King Guestroom Wire Shelves: (Drawing A412) 4. King Suite Guestroom Wire Shelves: (Drawing A413) Closet 1 (Up to 32 Wide) Closet 2 (Up to 26 Wide) 5. Double/Queen Guestroom Wire Shelves: (Drawing A 414) PAGE 3

REVISED: 09/03/13 4 1430-6693-11 Medium End Cap White 4 1430-6694-11 Large End Cap White 6. Accessible Double/Queen Guestroom Wire Shelves: (Drawing A 415) a. Two (2) shelves to be provided full width of closet mounted at 48 and 58 inches above finished floor. Hanging rod to be located under open section of bottom shelf. b. Three (3) additional 12 wide stacked shelves located to one side of closet below bottom shelf. 1) Storage Shelves to be located at the following intervals: 12, 24, and 36. 2) Shelf Depth: 12 inches. c. Parts List: The following is a parts list for this configuration. List shall be verified by Closet 1 (Up to 30 Wide) (3) 2 1210-1212-11 12" D Storage Shelf - White (1) 3 1210-1212-11 12" D Storage Shelf - White 12 1430-6620-11 Versa-Clip w/ Tri-Loc II Anchor - White 7 1430-6621-11 Side Wall Bracket w/tri-loc II Anchor - White 5 1430-6665-11 Adjustable Pole Clip- White 2 1430-6671-11 Base Cap - White 1 1430-6672-11 70" Support Pole- White 28 1430-6693-11 Medium End Cap - White 12 1430-6694-11 Large End Cap - White 7. Extended Double/Queen Guestroom Wire Shelves: (Drawing A 416) PAGE 4 FILE: 10-105723_13-C-Wire Closet And Utility Shelving CFRST SPECMSTR-NEW BUILD 2013, Marriott International, Inc.

4 1430-6693-11 Medium End Cap White 4 1430-6694-11 Large End Cap White 8. Double/Queen Inline Suite Guestroom Wire Shelves: (Drawing A 417) PART 3 EXECUTION 3.01 INSTALLATION A. Install in accordance with manufacturer's published instructions, square and plumb, secured rigidly in position. 1. Layout scheduled components prior to installation to verify wall to wall and floor to ceiling heights, widths, plumb and flatness of surfaces. 2. Prepare anchor locations and select anchor types using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions. END OF SECTION PAGE 5