T-60 T-120 T-240 T-350 PUBLIC ADDRESS SYSTEM MIXER AMPLIFIER

Similar documents
USER MANUAL VIVALDI MZ550A. Distribution Mixer Amplifier

MIXER POWER AMPLIFIER BG-130

INSTRUCTION MANUAL POWERED MIXER MX-628

IP Series DUAL POWER AMPLIFIERS

AM/FM SYNTHESIZER TUNER

FS-7006PA FS-7012PA YA-7000 POWER AMPLIFIERS. AMPLIFIER AUTO SWITCHING MODULE (Optional) OPERATING INSTRUCTIONS

S5-ADU. Front... 4 Rear... 4

UHF WIRELESS TUNER CHANNEL TUNER 2 DIVERSITY WIRELESS TUNER WT-4820 O O

INSTALLATION MANUAL VOICE EVACUATION SYSTEM FS-7000 SERIES

INFRARED WIRELESS DISTRIBUTOR

Q-Tech. Q-Tech Commercial Series QTA 6060M/6130M Mixer Amplifiers. User Manual

User Manual. MA 240 Mixing amplifier

UHF WIRELESS SET WS-200/300

ECA COMMERCIAL AMPLIFIER OWNER S MANUAL ECA-70MIXAMP V / 70V / 4Ω Amplifier ECA-70MIXAMP-1-60 OUTPUT LEVEL POWER MASTER MIC 1

IMPORTANT SAFETY INSTRUCTIONS

DUAL POWER AMPLIFIERS DA-250D CU DA-250DH CU OPERATING INSTRUCTIONS

TOA 500 SERIES MIXER POWER AMPLIFIER

PM7400MKII. Instruction manual

3.Avoid spilling liquids or allowing materials to enter the cabinet

MA V 35W Mixer Amplifier

SA 125 mixer amplifier. user manual

ZM-6. Professional 19 Rack Mixer USER MANUAL. Content

User Manual. MA 21 Two zone mixing amplifier

SYSTEM MANAGEMENT AMPLIFIER VM-2120 (120 W) VM-2240 (240 W) RM-200M RM-210 EV-200 SV-200M

User Manual VOLUME PTT 1 MIC/LINE 2 MIC/LINE 3 MIC/LINE 4 MIC/LINE 5 MIC/LINE 6 MIC/LINE 7 MIC/LINE 8 MIC/LINE 9 MIC/LINE 10 LEVEL LEVEL TREBLE 6 MIC

DPAfour125, DPAfour250 AMPLIFIERS. Operating Manual

User Manual. imix 63 Stereo mixing preamplifier

User Manual. MODEL: QM600ASi

6 ZONE MIER AMPLIFIER PB-2807Z/PB-2813Z/PB-2826Z/PB-2836Z/PB-2850Z USER MANUAL. LY International Electronics Co., Ltd.

DIGITAL AMBIENT NOISE CONTROLLER

EQ-AMP60 60W Mixer Amplifier

MIXING CONSOLE CX-124 CX-164. TOA Corporation. Operating Instructions

19'' Rack Mount 300 Watt Power Amplifier/ Mixer w/70v Output & Mic Talkover USER MANUAL

Professional Mixer/Amplifiers Instruction Manual and Users Guide

INFRARED CONFERENCE SYSTEM TS-900 series

Block-800B bass head. user manual

POWERED MONITOR SPEAKER MSP10STUDIO

SL Slave Amplifiers. User Manual. Order codes: CRAM37 - SL V 4 x 60W CRAM22 - SL V 4 x 120W CRAM23 - SL V 4 x 240W

Mixer Amplifier series

User Manual. ia480x Power amplifier

TOA NEW 900 SERIES MIXER POWER AMPLIFIER A-901A. General Description. TOA Corporation. Operation Instruction Manual

TOA NEW 900 SERIES MIXER PREAMPLIFIER M-900A

PROLUDE AMPLIFICATION D750. User s manual for the tube preamplifier version

KXR. Owner, s Manual. One hundred KEYBOARD EXTENDED RANGE TYPE: PR 262 P/N

i3speakers LX503 MK2 User Manual

Professional Power Amplifier HORIZON SERIES USER MANUAL. Content

PRE16/26 AUDAC PROFESSIONAL AUDIO EQUIPMENT. PRE16/26 6 Channel Pre-Amplifier Single/Double Output Zone. User Manual & Installation Guide

Operating Instruction Manual ELECTRONIC MUSIC AMPLIFICATION SYSTEM. Model KD-1. Toa Electric Co., Ltd. KOBE, JAPAN

PROFESSIONAL SMPS STEREO AMPLIFIERS USER GUIDE

Single Channel Radio Mic System USER MANUAL. WMU-116-H (Hand Held) WMU-116-B (Belt Pack) Single Channel Radio Mic System

USER MANUAL QSM-606AZ QSM-612AZ QSM-624AZ MIXER AMPLIFIER

MANUAL MA200

T L Audio. User Manual EQ1 VALVE EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

PA240 ORDERCODE D6113

mix 502, mix 802, mix 1202FX mixer user manual

LA-SERIES LOOP AMPLIFIERS. Item ref: UK, UK User Manual

PTA3 2X75 Watt Stereo Power Amplifier

CABINET POWERED MIXING CONSOLE

ZM 84 Audio Mixer. User Manual. Order code: CRAM41. Audio Mixer ZM 84 AUX 3 AUX 1 AUX 2 AUX 4 MASTER 1 MASTER 2 OFF BASS BASS TREBLE TREBLE BASS BASS

EPA152/252/502. User Manual.

UA ª 35T II Utility Amplifier OPERATING INSTRUCTIONS

TOA 900 SERIES POWER AMPLIFIER P-924A

PAM-240/360 Public Address Amplifier

Classic Series Public Address Amplifiers C10 & C20 Models

ADSworldwide (AUDIO DESIGN SERVICES LIMITED)

MA40G & MA60G Mixer Amplifiers. MA60G Front Silkscreen Artwork

INFRARED WIRELESS TUNER

Classic Series Public Address Amplifiers C10 & C20 Models

POWERED MIXER DIGITAL ECHO EFFECT ECHO LEVEL ECHO LEVEL ECHO LEVEL ECHO LEVEL ECHO VOL REPEAT MPM CHANNEL POWERED MIXER OWNER S MANUAL

SAGA PRO SERIES STEREO POWER AMPLIFIER OPERATION MANUAL

E4-130, E4-250 power amplifier. user manual

Linear. Headphone amplifier / Single Source Preamp. User manual

GIG RIG PERFORMER. Order Code: SPEA43 ENGLISH

E-800 power amplifier. user manual

Owner s Manual. Keep This Manual For Future Reference. 2 HIGH 1 HIGH 3 HIGH EFFECT DIGITAL EFFECT MONITOR INST 1. Hi-Z. Hi-Z. Hi-Z EFFECT OUT.

SPA2060, SPA2120, SPA2240 amplifier. User Manual

Model CC4052. CC Series Amplifier. Installation and Use Manual

STEREO POWER AMPLIFIER OWNER MANUAL PR-150 DESIGNED IN U.K. PDF created with FinePrint pdffactory trial version

Model CC4041. CC Series Amplifier. Installation and Use Manual

PROFESSIONAL STEREO AMPLIFIERS USER GUIDE

PREMIUMAUDIOVIDEOLIGHTINGANDPOWERPRODUCTS

15" 500W self-powered subwoofer

100V version: 100 volts AC, 50/60 Hz, 900W 120V version: 120 volts AC, 60 Hz, 900W 240V version: 240 volts AC, 50 Hz, 900W

IMPORTANT SAFETY INSTRUCTIONS

REVAMP4120T Instruction manual

DSR-3. Bedienungsanleitung User Guide

SAFETY WARNINGS AND GUIDELINES

Q-Tech Commercial Series. 86 Derby St. Pascoe Vale VIC 3055 ( : *

E-800 power amplifier. user manual

PROFESSIONAL KARAOKE MIXING AMPLIFIER MANUAL

E-400 power amplifier. user manual

EPA104/254. User Manual.

M-300 Mono power amplifier User s guide

Built. Demanding. To Meet The Most. User Requirements. SWM Series Wall Mount Amplifiers

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

TA 450 MK-X TA 600 MK-X TA 1050 MK-X TA 1400 MK-X TA 2400 MK-X power amplifier. user manual

DPA74/154 AUDAC PROFESSIONAL AUDIO EQUIPMENT. DPA74/154 Quad Channel Class-D Amplifier. User Manual & Installation Guide

IMPORTANT SAFETY INSTRUCTIONS

USER MANUAL MG-TA1000 POWER AMPLIFIER

Transcription:

- - - + - + + + - - - + - + + + 4 6 AUDIO OPERATION MANUAL ON OFF POWER T- MIXER AMPLIFIER BASS TREBLE MIC MIC MIC AUX T-6 T- T T- MIXER AMPLIFIER Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference. LEVEL TEMP 4 PROT 6 AUX MIC

TABLE OF CONTENTS. SAFETY PRECAUTIONS.... GENERAL DESCRIPTION.... FEATURES... 4. NOMENCLATURE AND FUNCTIONS 4. Front Panel(U)...6 4. Rear Panel(U)... 4. Front Panel(U)... 4.4 Rear Panel(U).... CONNECTIONS.. Speaker Connections..... XLR Connections... 6. MACHINE OPERATION.... APPLICATIONS....BLOCK DIAGRAM...4.SPECIFICATIONS....DIMENSIONAL DIAGRAM... T-6/T-/T/T-

. SAFETY PRECAUTIONS Be sure to read the instructions in this section carefully before use. Make sure to observe the instructions in this manual as the conventions of safety symbols and messages regarded as very important precautions are included. We also recommend you keep this instruction manual handy for future reference. Safety Symbol and Message Conventions Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling. Before operating your product, read this manual first and understand the safety symbols and messages so you are thoroughly aware of the potential safety Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury. Indicates a potentially hazardous situation which, if mishandled, could result in moderate or minor personal injury, and/or property damage. When Installing the Unit Do not expose the unit to rain or an environment where it may be splashed by water or other liquids, as doing so may result in fire or electric shock. Use the unit only with the voltage specified on the unit. Using a voltage higher than that which is specified may result in fire or electric shock. Do not cut, kink, otherwise damage nor modify the power supply cord. In addition, avoid using the power cord in close proximity to heaters, and never place heavy objects -- including the unit itself -- on the power cord, as doing so may result in fire or electric shock. Be sure to replace the unit's terminal cover after connection completion. Because high voltage is applied to the speaker terminals, never touch these terminals to avoid electric shock. Be sure to ground to the safety ground (earth) terminal to avoid electric shock. Never ground to a gas pipe as a catastrophic disaster may result. Avoid installing or mounting the unit in unstable locations, such as on a rickety table or a slanted surface. Doing so may result in the unit falling down, causing personal injury and/or property damage. When the Unit is in Use Should the following irregularity be found during use, immediately switch off the power, disconnect the power supply plug from the AC outlet and contact your nearest ITC dealer. Make no further attempt to operate the unit in this condition as this may cause fire or electric shock. If you detect smoke or a strange smell coming from the unit. If water or any metallic object gets into the unit If the unit falls, or the unit case breaks If the power supply cord is damaged (exposure of the core, disconnection, etc.) If it is malfunctioning (no tone sounds.) To prevent a fire or electric shock, never open nor remove the unit case as there are high voltage components inside the unit. Refer all servicing to your nearest ITC dealer. Do not place cups, bowls, or other containers of liquid or metallic objects on top of the unit. If they accidentally spill into the unit, this may cause a fire or electric shock. Do not insert nor drop metallic objects or flammable materials in the ventilation slots of the unit's cover, as this may result in fire or electric shock. T-6/T-/T/T-

. SAFETY PRECAUTIONS When Installing the Unit Never plug in nor remove the power supply plug with wet hands, as doing so may cause electric shock. When unplugging the power supply cord, be sure to grasp the power supply plug; never pull on the cord itself. Operating the unit with a damaged power supply cord may cause a fire or electric shock. When moving the unit, be sure to remove its power supply cord from the wall outlet. Moving the unit with the power cord connected to the outlet may cause damage to the power cord, resulting in fire or electric shock. When removing the power cord, be sure to hold its plug to pull. Do not block the ventilation slots in the unit's cover. Doing so may cause heat to build up inside the unit and result in fire. Avoid installing the unit in humid or dusty locations, in locations exposed to the direct sunlight, near the heaters, or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock. When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and/or property damage. In addition, the object itself may fall off and cause injury and/or damage. Make sure that the volume control is set to minimum position before power is switched on. Loud noise produced at high volume when power is switched on can impair hearing. Do not operate the unit for an extended period of time with the sound distorting. This is an indication of a malfunction, which in turn can cause heat to generate and result in a fire. Contact your ITC dealer as to the cleaning. If dust is allowed to accumulate in the unit over a long period of time, a fire or damage to the unit may result. If dust accumulates on the power supply plug or in the wall AC outlet, a fire may result. Clean it periodically. In addition, insert the plug in the wall outlet securely. Switch off the power, and unplug the power supply plug from the AC outlet for safety purposes when cleaning or leaving the unit unused for days or more. Doing otherwise may cause a fire or electric shock. An all-pole mains switch with a contact separation of at least mm in each pole shall be incorporated in the electrical installation of the building. T-6/T-/T/T- 4

. GENERAL DESCRIPTION ITC series of public address mixer amplifiers have power ratings from 6 to watts and feature optional balanced MIC inputs, AUX level inputs and EMC (priority) level inputs.. FEATURES =Rated outputs from 6W to W and 4W and W. =V/V line transformer-isolated speaker outputs, low impedance 4-6 ohms speaker outputs. =Two EMC priority input.. =Two stereo aux input and two line input. =EMC input with priority over all other inputs except MIC. =AUX, MIC, Tuner, Bass, Treble volume control. =MIC mute level control. =Power and protection indicators and 6 output level meters. T-6/T-/T/T-

4. NOMENCLATURE AND FUNCTIONS 4. T-6/ FRONT PANEL(U) T-6 MIXER AMPLIFIER LEVEL POWER TEMP PROT ON OFF BASS - + - + - + - + TREBLE MIC MIC MIC AUX AUX - + - + - + - + MIC 4 6. POWER Power indicator. POWER SWITCH On top of the opening Power Press the end, power shut down. BASS Adjust bass response. Rotate clockwise to increase bass output and anticlockwise to reduce it. 4. TREBLE Adjust treble response. Rotate clockwise to increase treble output and anticlockwise to reduce it.. MIC \ MIC \ MIC MIC volume control (MIC/MIC/MIC) 6. AUX \ AUX AUX volume control(aux /AUX ). MIC MIC input 6. Microphone jack input. LEVEL INDICATORS Level meters 6 output level indicators. PROT Protection indicator.temp Temperature indicator T-6/T-/T/T- 6

NOMENCLATURE AND FUCTIONS 4. REAR PANEL(U) AVIS: -NE PAS QUVRIR TALV MUTE EMC INPUT LINE INPUT AUX AUX OUT OUTPUT COM 4-6 V V ~V Hz MIC MIC MIC MIC 4 6.MUTE Mute Microphone mute level control.mic\mic MIC Balanced inputs. LINE \ LINE Line Balanced inputs 4.AUX/AUX Auxiliary input jack, Non-equilibrium of connecting peripherals signal.out Line output, Non-equilibrium type, the output of all input signals. 6.SPEAKER TERMINALS Connectors for 4-6 ohms or V and V speaker.cooling FANS.~V+/Hz AC POWER INPUT.AC FUSE.EMC EMC Input Fire alarm signal input T-6/T-/T/T-

4. NOMENCLATURE AND FUNCTIONS 4. T/ FRONT PANEL(U) T MIXER AMPLIFIER LEVEL POWER BASS TREBLE MIC MIC MIC AUX AUX - + - + ON - + - + OFF - - + + - - + + MIC 4 6. POWER Power indicator. POWER SWITCH On top of the opening Power Press the end, power shut down. BASS Adjust bass response. Rotate clockwise to increase bass output and anticlockwise to reduce it. 4. TREBLE Adjust treble response. Rotate clockwise to increase treble output and anticlockwise to reduce it.. MIC \ MIC \ MIC MIC volume control (MIC/MIC/MIC) 6. AUX \ AUX AUX volume control(aux /AUX ). MIC MIC input 6. Microphone jack input. LEVEL INDICATORS Level meters 6 output level indicators T-6/T-/T/T-

NOMENCLATURE AND FUCTIONS 4.4 REAR PANEL(U) AVIS: -NE PAS QUVRIR OUTPUT COM 4-6 V V MUTE EMC INPUT LINE INPUT AUX AUX OUT ~V Hz T6ALV MIC MIC MIC MIC 4 6. SPEAKER TERMINALS Connectors for 4-6 ohms or V and V speaker.mute Mute Microphone mute level control.mic\mic MIC Balanced inputs. LINE \ LINE Line Balanced inputs.aux/aux Auxiliary input jack, Non-equilibrium of connecting peripherals signal 4.OUT Line output, Non-equilibrium type, the output of all input signals..cooling FANS 6.~V+/Hz AC POWER INPUT.EMC EMC Input Fire alarm signal input T-6/T-/T/T-

. CONNECTIONS. SPEAKER CONNECTIONS COM 4-6 V V COM 4-6 V V COM 4-6 V V 4 (T-6) (T-) (T) (T-) 6 4 (T-6) (T-) (T) (T-) 4-6 V LINE V LINE. XLR CONNECTIONS T-6/T-/T/T-

6. MACHINE OPERATION OPERATION ATTENTION MUTE FUNCTION The four output connectors only can choose two connectors work together. If voltage is V/V, the speakers must be with transformer and make sure the total power wattage of speaker is % less than the power wattage of amplifier. MIC with the first priority over other inputs, the adjustment should be kept within -db with the mute connector, db is the original setting. GUIDANCE OF EXCLUDING ERRORS Phenomena All the wires are connected well but no voice output Power on but alarming signal No voice output in normal condition Cause No power or wrong plug connection Fuse is burned Volume is town off 4 No input signal Overloading or short circuit Voltage is not stable, too high or low Machine is in protection condition in case of high temperature Wrong wire connection T-6/T-/T/T-

. APPLICATIONS EMERGENCY PANEL MIC LINE ALARM OUT AUDIO SOURCES AUDIO OUT ADRESS TAG COM + ALARM IN - AVIS: -NE PAS QUVRIR AVIS: -NE PAS QUVRIR ~V Hz TALV ~V Hz TALV MUTE EMC INPUT MIC MIC MIC MIC LINE INPUT MIC MIC AUX AVIS: AUX OUT SPEAKERS -NE PAS QUVRIR OUTPUT COM 4-6 V V INPUTS LINK AUDIO OUT ADRESS TAG COM XLR BAL -GND -HOT+ -COLD AVIS: -NE PAS QUVRIR ~V Hz TALV AVIS: -NE PAS QUVRIR AUDIO SOURCES TALV ~V Hz R L R L T-6/ REAR PANEL CONNECTIONS INPUTS POWER AMPLIFIER OUTPUTS AC~ V ~6Hz TAL V T-6/T-/T/T-

APPLICATIONS T/ REAR PANEL CONNECTIONS SPEAKERS OUTPUT COM 4-6 V V MUTE EMC INPUT MIC MIC MIC MIC EMERGENCY PANEL -NE PAS QUVRIR ~V Hz TALV AVIS: MIC LINE ALARM OUT + ALARM IN - AUDIO SOURCES AUDIO ~V Hz OUT TALV AVIS: -NE PAS QUVRIR COM ADRESS TAG AVIS: -NE PAS QUVRIR LINE INPUT AUX AUX OUT ~V Hz T6ALV MIC MIC POWER AMPLIFIER XLR BAL -GND -HOT+ -COLD AVIS: -NE PAS QUVRIR INPUTS OUTPUTS AC~V ~6Hz INPUTS LINK TAL V AUDIO ~V Hz OUT TALV AVIS: -NE PAS QUVRIR COM ADRESS TAG AUDIO SOURCES R L R L T-6/T-/T/T-

. BLOCK DIAGRAM REC OUT EB EMC EB MIC EB LINE INPUT MIC EB LINE INPUT MIC EB AUX EB AUX EB BASS/TREBLE VOLUME MUTE PROTECT PA TO V COM 4 COM LEVEL INDICATOR PT POWER Z V~V AC /6Hz T-6/T-/T/T- 4

. SPECIFICATIONS MIXER AMPLIFIER(U) MODEL RATED POWER OUTPUT T-6 6W T- W SPEAKER OUTPUTS INPUT TONE FREQUENCY RESPONSE S/N RATIO T.H.D CROSSTALK MUTING FUNCTION CONTROLS INDICATORS PROTECTION 4~6,V/V MIC mv/6 Ohms,Balanced/Unbalanced AUX 4 mv/kohms, Unbalanced EMC mv/kohms, Unbalanced Bass: -+ db at Hz Treble: -+ db at KHz Hz~KHz MIC 66dB;AUX db Less than % at KHz,/ rated power MIC : db;aux db MIC over other input signals with ~db attenuation EMC ove all inputs except MIC Individual gain controls, power switch Power LED,LED level meter,protect AC fuse, short-circuit and high temperature POWER REQUIREMENTS POWER CONSUMPTION DIMENSION(mm) NET WEIGHT GROSS WEIGHT W.Kg.Kg ~V -+ %/Hz W 44X6X.4Kg.4Kg T-6/T-/T/T-

SPECIFICATIONS MIXER AMPLIFIER(U) MODEL RATED POWER OUTPUT T 4W T- W SPEAKER OUTPUTS INPUT TONE FREQUENCY RESPONSE S/N RATIO T.H.D CROSSTALK MUTING FUNCTION CONTROLS INDICATORS PROTECTION 4~6,V/V MIC mv/6 Ohms,Balanced/Unbalanced AUX 4 mv/kohms, Unbalanced EMC mv/kohms, Unbalanced Bass: -+ db at Hz Treble: -+ db at KHz Hz~KHz MIC 66dB;AUX db Less than % at KHz,/ rated power MIC : db;aux db MIC over other input signals with ~db attenuation EMC ove all inputs except MIC Individual gain controls, power switch Power LED,LED level meter,protect AC fuse, short-circuit and high temperature POWER REQUIREMENTS POWER CONSUMPTION DIMENSION(mm) NET WEIGHT GROSS WEIGHT 4W.4Kg.Kg ~V -+ %/Hz 44X44X W.Kg.6Kg T-6/T-/T/T- 6

ON OFF POWER - - - + - - - + - + - BASS + + + + + - - - - - + - + + -NE PAS QUVRIR TREBLE MIC MIC MIC AUX AUX - + - + + + MIC LEVEL TEMP PROT. DIMENSIONAL DIAGRAM T-6/ UNIT :mm 44 T-6 MIXER AMPLIFIER LEVEL POWER TEMP PROT ON BASS TREBLE MIC MIC MIC AUX AUX 4 4 4 OFF + MIC 46 AVIS: TALV MUTE EMC INPUT LINE INPUT AUX AUX OUT OUTPUT COM 4-6 V V ~V Hz MIC MIC MIC MIC 6 UNIT :mm T-6 MIXER AMPLIFIER Over Over Over T-6/T-/T/T-

ON OFF - POWER - - + - + + + - - - - - + - - + - BASS + + + + + + - - - + - + + + TREBLE MIC MIC MIC AUX AUX LEVEL MIC DIMENSIONAL DIAGRAM T/ UNIT :mm 44 T MIXER AMPLIFIER LEVEL POWER 46 46 4 4 BASS TREBLE MIC MIC MIC AUX AUX ON OFF MIC AVIS: -NE PAS QUVRIR OUTPUT COM 4-6 V V MUTE EMC INPUT LINE INPUT AUX AUX OUT ~V Hz T6ALV MIC MIC MIC MIC 6 UNIT :mm T MIXER AMPLIFIER Over Over Over T-6/T-/T/T-

AUDIO Guangzhou ITC Electronic Technology Limited Http://www.itc-pa.com.cn - Version.