T108, GPS/GLONASS/BEIDOU Time Server

Similar documents
T200, PTP/IEEE 1588 Grandmaster Clock and

satech SynchroStar GPS 200 Series

[ tima-datasheet-en v11.1 ]

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

Reason RT431. GE Grid Solutions. GPS Precision-Time Clock. Precise Time Synchronization. Compact Design. Hardened for Industry. Time Synchronization

Specifications subject to change without notice Heartbeat of the Smart Grid

Reason RT430/RT434. GE Grid Solutions. GNSS Precision-Time Clocks. Precise Time Synchronization. Flexible Design. Hardened for Industry.

Your benefits using DTS 4160.grandmaster:

DTS 4210.timecenter. Swiss Time Systems. High precision time server, grandmaster and PRC

Your benefits using DTS 4160.grandmaster:

The FEI-Zyfer Family of Modular, GPS-Aided Time & Frequency Systems

Side view View from below Rear view

The FEI-Zyfer Family of Modular, GPS-Aided Time & Frequency Systems

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

NTS-6002 VERSION 11 HARDWARE MANUAL

PQM3000 Class A rack 19 power quality analyzer for CTs or current clamps

LANTIME Network Time Servers

Power Meter Series PM3200 Functions and characteristics

PQM4000RGW Class A DIN 192x144 power quality analyzer with Rogowski coils

SPECIFICATION. Online UPS 3000VA

SWT 3000 Teleprotection technical data siemens.com

ExacTime GPS Time & Frequency Generator

GPS-Disciplined-Rubidium Clock AR70A-00

02/11/2015

PQM3000R Class A network analyzer according to EN for power quality monitoring

PPS usable by timing applications via serial port emulation

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

SEL-2488 Satellite-Synchronized Network Clock

GPS10RBN - 10 MHz, GPS Disciplined Rubidium Frequency Standard

PQM3000RGW Class A rack 19 power quality analyzer with Rogowski coils

02/11/2015

08/07/2015

Digital Instruments S.r.l. GPS-MXS. Multireference Time-Frequency

SA-320 Installation Guide SA-320. Installation Guide. Date: Mar, 2011 Version: 2.5. All Rights Reserved

GLOBALSAT GPS Engine Board

Utility Communications Teleprotection Equipment TPT-200

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

Q.raxx A slimline RS / EC Multi Channel System for Thermocouples

120W UHF Transmitter/Repeater

GPS Time and Frequency Reference Receiver

High precision measurement system for current and voltage IHC-A/B-RM01/03

PQube 3 Specifications

R40 Mk III AIS Base Station

SA-320 Installation Guide SA-320. Installation Guide. Date: June, 2007 Version: 2.2. All Rights Reserved

Networks IT, TN, TT networks 3 and 4-phase networks Up to 4 single-phase networks. Measured data memory 256 MByte Flash 32 MB SDRAM

EX CHANNEL ISOLATED THERMOCOUPLE AND VOLTAGE MEASUREMENT INSTRUMENT

INSTALLATION MANUAL. Model: Smart Analyzer Manufacturer: Smart Impulse. Power meter with consumption breakdown by use 03/12/13

PowerLogic power-monitoring units. PM700 series power meter. Technical data sheet

SyncServer S650 Accurate, Secure, and Flexible Time and Frequency Standard

NTS-pico. Miniature NTP Time Server for Small Networks

Q.raxx A101-8 slimline RS / EC

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

CM /100/1000BASE-T

UMG 509-PRO. Multifunction power analyser with RCM

S650 with two optional Timing I/O modules. Unparalleled Flexibility

Reason RT412. Technical Manual. Optical Transceiver. Platform Hardware Version: A Publication Reference: RT412-TM-EN-2

Q.raxx A slimline RS / EC

02/11/2015

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

XMU+ Environmental, Safety and Specifications

SEL Serial Radio Transceiver. The industry-recognized standard for reliable, low-latency wireless communications

MN5020HS Smart GPS Antenna Module

08/07/2015

MATERIAL SPECIFICATIONS FOR WIRELESS LINK

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

02/11/2015

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

REFERENCES BASE BDR_UK-V5.1

2017 Advanced Energy Industries, Inc. HITEK POWER MV2000 SERIES MEDIUM-VOLTAGE HIGH-CURRENT POWER SUPPLIES

MODEL 1205B/C MODEL 1206B/C GNSS SYNCHRONIZED CLOCK OPERATION MANUAL

PLC-K506 Series FEATURES DESCRIPTION FEATURES

DVB-T/H Portable Test Transmitter

Remote Site Monitoring

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

SPECTRACOM ecall Compliance Tool

SyncServer S650 Accurate, Secure, and Flexible Time and Frequency Standard

Končar TMS - Bushing monitoring

AUM FAMILY Programmable DC Power Supplies

02/11/2015

SEL-3060 Ethernet Radio Data Sheet

PM5000 Series. PowerLogic PM5100, PM5300 and PM5500 series

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

SPECIFICATION FOR OVERCURRENT RELAYS

Energy Management Three-phase energy meter with output modules Type EM4-DIN

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

Application. Key Features. Benefits. Contact us. Solution for Digital TV coverage. Single DVB-T/-H/-T2 & ISDB-T Gapfiller 1W-10W

Enabling Tomorrow s Technology Today

Q.raxx A slimline RS / EC Universal Measurement System

02/11/2015

z488xx RF Switches/Multiplexers PXI

RSU-101E Specifica on

z48831 / z :1/ 16:1 6 GHz Multiplexer Module

TIMESPY ELITE - PORTABLE PRECISION TIME MEASUREMENT. GPS Referenced Portable Precision Time Measurement, Analysis and Logging Instrument

CONDOR C1216 GPS RECEIVER MODULE technical notes ZELIA INTEGRATES ANTENNA, GPS RECEIVER, RTC AND LNA

Introduction DIN rail mounted electricity meters

GPS6000-PRO. GNSS Time Receiver. User Manual Version 1.1

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

Transcription:

T108, GPS/GLONASS/BEIDOU Time Server Galileo (Europe) and QZSS (Japan) ready NTP Time server / Multi-GNSS Primary Clock, with PoE and advanced I/O synchronization features. - Static applications -

HEOL-T108: HIGH ACCURACY SYNCHRONIZATION UNIT The T108 Time server / Multi-GNSS Clock has been designed to provide very accurate timing information trough an Ethernet link (using NTP/SNTP protocol), for Network synchronization and measurement applications, without the need to be connected to external Network, hence preserving your Network insulation. It is dedicated to static applications. Based on a high performance 32 channels GPS/GLONASS/GALILEO/BEIDOU timing chipset (with - 160dBm sensitivity), it delivers extremely accurate timing information, even in poor signal level conditions (indoor, urban canyons and signal obscured environments). The antenna (protected against shortcircuit) does not need to be located up a mast or on the rooftop as is the norm, which considerably reduces the cost and complexity of deployment in terms of antenna cabling and lightning strike protection and reduces the cost of maintenance. With Time-Receiver Autonomous Integrity Monitoring (T- RAIM) algorithm, accuracy is guaranteed in the weakest signal environments. Thanks to its self-survey mode, the accuracy of the timestamp (compliant with SNTP protocol) is better than ±200 nanoseconds for the receive packet and ±600 nanoseconds for the transmit packet (with the 1µs version) - reference is UTC atomic clock. This accuracy is achievable even with only 1 satellite being tracked. If the satellites signals are completely lost, the hold-over mode enables the module to keep sending accurate Ethernet frames, with a drift better than 500µs/day (with OCXO option). The Time Service software can be installed on any host computer, to synchronize computers using NTP/SNTP protocol. Accuracy and specific alarms are displayed at every connection. A web server with secure access allows you to configure the HEOL-T108, and monitor its status at a

glance (GNSS satellites strength signals, Ethernet connections, alarms, input/outputs ). Automatic E-mails can be sent by the HEOL-T108, periodically or when alarms appear. This function is fully configurable via the http server. A 2500V isolated event input allows you to time-stamp events from external systems, with very high accuracy (±100 nanoseconds, refer to UTC atomic clock). The TimeStamp information is reported through RS232, SNMP trap, E-mail or Broadcast frame. A second event input is available in option. In option, an battery powered internal RTC can provide timing information if no GNSS satellites are available at power-up (antenna disconnected or hidden inside a building). Alarm relay is available, for driving your external systems in case of failure of the T108. A highly accurate pps (TOP signal) signal (±100ns) is available on SUB-D9 connector (pin 8 for Linux applications) or I/O connector (polarity, period, length, and delay compensation are configurable by user). It is also available with optional 1500V isolated static relay (in this case Alarm relay is not available). In option, IRIG-B003 output is available on the I/O connector. Alarms are displayed through SNMP traps (Ethernet interface) or through RS232. SNMP can also be used to configure T108 parameters (instead of http web server). A RS232 or RS422 serial port can be accessed for remote control and monitoring (protocol output : TSIP or NMEA, selectable through web server). Historic data can be backed-up to an EEPROM (up to 8000 status records). The Power On Ethernet enables installation of the T108 without the need for additional cables to provide power. The T108 is available in a compact (DIN rail adaptable) or 19 rack mounted form factor, with a LCD module that displays the status and timing information.

GNSS antenna AC/DC T108 RTC Clock generator OCXO/TCXO Power + PoE GNSS time receiver Processor + FPGA Ethernet 100M RS232 RS422 External Events TOP/pps IRIG/10M Remote interface +NMEA Event inputs Sync outputs User systems NTP/SNTP (synchro and events) http (config) SNMP (alarms and events) SMTP (E-mail) Network NTP clients / servers Automated systems T108 synoptic and external links

SPECIFICATIONS GNSS Receiver Type 32 channels GPS/GLONASS/GALILEO/BEIDOU/QZSS Sensitivity -160dBm tracking, -148dBm acquisition Time Accuracy (pps) ±15 ns rms (1σ) Warm up time - hot start - cold start < 1 minute < 2 minutes Self survey mode (with OCXO or Rubidium) 24 hours Timing Generator Timing Ethernet protocol SNTP V4, NTP Broadcast/Unicast (100 requests per second maximum) Configuration / monitoring http server or SNMP manager Absolute timestamp error ±200ns for Rx (1µs version) (refer to UTC time) ±600ns for Tx (1µs version) Timestamp drift when Standard TCXO option: 200µs/hour synchronization lost OCXO option : less than 500µs/day (at constant temperature) Rubidium option : less than 1µs/day Battery powered RTC option 1 millisecond accuracy Autonomy : 6 months Max drift 1 s / day Power supply Input Voltage Power Ethernet: IEEE 802.3af compliant Auxiliary: 14 to 60 VDC (-48V Telecom compliant) or 85/250VAC, 110/250VDC (Rack) 47/63Hz, (400 Hz on request) Power consumption T108C: 5W T108R: 8W T108C with OCXO: 7W T108R with OCXO: 10W Interfaces Auxiliary DC Power Supply 2.54mm header, anti-extraction 5V GNSS Active antenna T108C : SMA or TNC T108R : SMA, TNC or N Ethernet link RJ45, 10/100Mbps + POWER Remote RS232 / RS422 SUB-D9, 38400/8/No/1 pps output On SUB-D9 (pin 8, for Linux applications) On I/O connector : RS422 level, or on fast static relay. Alarm Relay On I/0 connector 2A/250V. 2500V isolation Event input On I/0 connector 25V max peak voltage (add R series for more), 2500V isolation, ±100ns accuracy Environmental Operating Temperature From 0/50 C to -40/+85 C, depending Upon the option Storage Temperature -40 / +85 C Humidity 90% non-condensing Dimensions (T108C) 201 x 95 x 26 (mm) Weight (T108C) 340 grams Dimensions (T108R) 1U -482.6mm (19 )

-depth with SMA connector -depth with N connector Weight (T108R) 130 mm 150 mm 1,85 Kg Note : Heol Design is not responsible for the operation or failure of operation of GNSS satellites or the availability of GNSS satellite signals. According to directive, the T108 module has passed the following tests : EN55022/55011 class B : conducted and radiated emissions. EN61000-4-2: Immunity to electrostatic discharges. EN61000-4-3: Immunity tests on electromagnetic fields radiated at radio-electrical frequencies, with 10V/m electromagnetic field. EN61000-4-4: Immunity to rapid transients. EN61000-4-5: Immunity to surge. EN61000-4-6: Immunity tests on conducted interference, induced by radio-electrical fields. EN61000-4-8: Immunity to Power frequency magnetic field (30 A/m) EN61000-4-11: Voltage dips, short interruptions and voltage variations immunity tests. Compliance with the International Safety Standard for Information Technology (IEC/EN 60950). The HEOL-T108x module is RoHS (lead free) compliant.

T108 19 1U Rack rear view (with N antenna connector) 3&4 pins : Alarm relay or PPS/TOP output on Static relay (option PPSREL) - + 1 + 2-3 4 5 6 1&2 pins : Event input #1 5&6 pins : PPS/TOP RS422 output or IRIG B003 output (option IRIG) or Event input #2 (option EVENT2) I/O connector details

ORDERING PART NUMBER T108R-10µs-AC-I/O-OCXOSR-RTC Housing R: 19 Rack C: Compact NTP 1µs accuracy 10µs 100µs 1ms Power DC : 14 to 60V DC/POE: DC+Power Ethernet AC : 110 to 250V (Rack only) I/O option I/O connector mounted (blank : not mounted) OCXO option OCXOSR : standard (0 / +50 C) OCXOMR : medium (-20 / +65 C) OCXOHR : high (-40 / +70 C) RUB : Rubidium (Rack in AC version) - 0 / +50 C RTC option : for fast start without GNSS satellites If other options are needed, just add the part number of these options at the end of the T108 part number : -422 for RS422 serial port instead of RS232 -EVENT2 for secondary Event input -IRIG for IRIG-B003 output -PPSREL for PPS/TOP output on fast static relay -N or TNC connector option (N only for rack)