THOMAS SAMUEL THOMAS SAMUEL 90W PWM Output LED Driver PWM90 series IP67 IS 15885(Part 2/Sec13) R41027766 ~ File Name:PWM90SPEC 1110
SPECIFICATION MODEL OUTPUT 90W PWM Output LED Driver WORKING HUMIDITY ~ 95% RH noncondensing ENVIRONMENT STORAGE TEMP., HUMIDITY 40 ~, 10 ~ 95% RH SAFETY & EMC OTHERS NOTE TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS Note.5 MTBF DIMENSION PACKING PWM90 series PWM9012 PWM9024 PWM9036 PWM9048 DC VOLTAGE RATED CURRENT RATED POWER 12V 7.5A 90W 24V 3.75A 90W 36V 2.5A 90W 48V 1.88A 90.24W DIMMING RANGE 0 ~ 100% PWM FREQUENCY (Typ.) 1.47kHz SETUP, RISE TIME Note.2 500ms, ms/ 115VAC or 230VAC HOLD UP TIME (Typ.) 16ms/115VAC or 230VAC VOLTAGE RANGE Note. 3 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section) FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.98/115VAC, PF>0.96/230VAC, PF>0.94/277VAC @ full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) TOTAL HARMONIC DISTORTION THD< %(@load 60%/115VAC, 230VAC; @load 75%/277VAC) (Please refer to TOTAL HARMONIC DISTORTION section) INPUT EFFICIENCY (Typ.) 88% 90.5% 90.5% 90.5% AC CURRENT (Typ.) 0.95A / 115VAC 0.5A / 230VAC 0.4A / 277VAC INRUSH CURRENT (Typ.) MAX. NO. of PSUs on 16A CIRCUIT BREAKER COLD START 60A(twidth=550 μs measured at 50% Ipeak) at 230VAC; Per NEMA 410 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC LEAKAGE CURRENT <0.25mA / 277VAC <0.5W OVERLOAD 108 ~ 1% rated output power Hiccup mode, recovers automatically after fault condition is removed PROTECTION SHORT CIRCUIT Shut down o/p voltage, repower on to recover 15 ~ 17V 28 ~ 34V 41 ~ 46V 54 ~ 60V OVER VOLTAGE Shut down o/p voltage, repower on to recover OVER TEMPERATURE Shut down o/p voltage, repower on to recover WORKING TEMP. Tcase=40 ~ 85 (Please refer to OUTPUT LOAD vs TEMPERATURE section) MAX. CASE TEMP. Tcase=85 DALI STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION Note.6 EMC IMMUNITY ± 0.03%/ (0 ~ 50 ) 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750, CSA C22.2 No. 250.1312; ENEC EN613471, EN61347213 independent,en62384, IP67,BIS IS15885( except for 36V), EAC TP TC 004 approved; Design refer to EN603351 Comply with IEC62386101, 102, 7 for DAType only I/PO/P:3.75KVAC I/PO/P:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55015, EN6100032 Class C (@load 60%) ; EN6100033,EAC TP TC 0 Compliance to EN6100042,3,4,5,6,8,11; EN61547, light industry level (surge immunity LineLine 2KV),EAC TP TC 0 902.4K hrs min. Telcordia SR332 (Bellcore) ; 224.2K hrs min. MILHDBK217F (25 ) 171*63*37.5mm (L*W*H) 0.77Kg; 18pcs/14.9Kg/0.97CUFT File Name:PWM90SPEC 1110
PWM90 series DIMMING OPERATION AC/L(Brown) AC/N(Blue) PWM90 DIM(Blue)* DIM(White)** Vo(Red) Vo(Black) Dimming principle for PWM style output Dimming is achieved by varying the duty cycle of the output current. * DIM for BlankType DA for DAtype * *DIM for BlankType DA for DAtype Output DC current ON TON Duty cycle(%) = 100% T Io=0A TON OFF Output PWM frequency : 1.47kHz fixed (Typ.) T 3 in 1 dimming function (for BlankType) Apply one of the three methodologies between DIM and DIM: 0 ~ 10VDC, or 10V PWM signal or resistance. Dimming source current from power supply: 100μA (typ.) Applying additive 0 ~ 10VDC 100% 90% Vo Vo DIM DIM Additive Voltage LED Strips 0.15% Duty cycle of output current (%) % 70% 60% 50% 40% 30% % DO NOT connect "DIM to Vo" 0% 0.6V 1V 0V 1V 2V 3V 4V 5V 6V 7V 8V 9V 10V Dimming input: Additive voltage Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz): 100% Vo Vo DIM DIM LED Strips Additive PWM signal 0.15% Duty cycle of output current (%) 90% % 70% 60% 50% 40% 30% % DO NOT connect "DIM to Vo" 6% 0% % 30% 40% 50% 60% 70% % 90% 100% Duty cycle of additive 10V PWM signal dimming input File Name:PWM90SPEC 1110
PWM90 series Applying additive resistance: 100% Vo Vo DIM DIM LED Strips Additive Resistance Duty cycle of output current (%) 90% % 70% 60% 50% 40% 30% % DO NOT connect "DIM to Vo" 6K/N 10K/N 0% Short 10K/N K/N 30K/N 40K/N 50K/N 60K/N 70K/N K/N 90K/N 100K/N (N=driver quantity for synchronized dimming operation) Dimming input: Additive resistance Note : 1. Min. duty cycle of output current is about 0.15%, and the dimming input is about 6KΩ or 0.6VDC, or 10V PWM signal with 6% duty cycle. 2. The duty cycle of output current could drop down to 0% when dimming input is less than 6KΩ or less than 0.6VDC, or 10V PWM signal with duty cycle less than 6%. DALI Interface (primary side; for DAType) Apply DALI signal between DA and DA. DALI protocol comprises 16 groups and 64 addresses. First step is fixed at 6% of output File Name:PWM90SPEC 1110
PWM90 series OUTPUT LOAD vs TEMPERATURE 100 100 LOAD (%) 60 50 40 230VAC Input only LOAD (%) 60 40 230VAC Input only 40 25 10 0 15 30 50 60 70 (HORIZONTAL) 40 25 0 45 60 70 85 (HORIZONTAL) AMBIENT TEMPERATURE,Ta ( ) Tcase ( ) STATIC CHARACTERISTIC POWER FACTOR (PF) CHARACTERISTIC Tcase at 75 LOAD (%) 100 90 70 60 50 40 90 100 125 135 145 155 165 175 1 0 230 305 INPUT VOLTAGE (V) 60Hz PF 1.00 0.90 0. 0.70 0.60 0.50 0.40 0.30 0. 0.10 0.00 % 30% 40% 50% 60% 70% % 90% 100% (90W) LOAD 277V 230V 115V Derating is needed under low input voltage. TOTAL HARMONIC DISTORTION (THD) EFFICIENCY vs LOAD PWM90 series possess superior working efficiency that up to 90.5% can be reached in field applications. 48V Model, Tcase at 75 48V Model, Tcase at 75 % THD 18% 16% 14% 12% 8% 6% 4% 2% 0% 50% 60% 70% % 90% 100% 277VAC 230VAC 115VAC EFFICIENCY(%) 94 92 90 88 86 84 82 78 76 % 30% 40% 50% 60% 70% % 90% 100% 277V 230V 115V LOAD LOAD File Name:PWM90SPEC 1110
PWM90 series LIFE TIME 1 100 LIFETIME(Kh) 60 40 0 25 35 45 55 65 75 85 Tc a s e ( ) File Name:PWM90SPEC 1110
PWM90 series Block Diagram PFC fosc : 50~1KHz PWM fosc : 60~130KHz I/P EMI FILTER & RECTIFIERS PFC CIRCUIT O.T.P. O.L.P. POWER SWITCHING PWM & PFC CONTROL RECTIFIERS & FILTER DIMMING CIRCUIT O.L.P. DETECTION CIRCUIT Vo Vo DIM DIM O.V.P. Mechanical Specification Case No. PWM90P Unit:mm 171 5 AC/L(Brown) AC/N(Blue) 50± 3 300± SJTW 18AWG 2C 5 5 63 2ψ 4.5 tc 31.5 85.5 tc : Max. Case Temperature 5 37.5 300± UL2464 18AWG 2C SJTW 16AWG 2C DIM(Blue)* DIM(White)** Vo(Red) Vo(Black) * DIM for BlankType DA for DAtype * *DIM for BlankType DA for DAtype 3 File Name:PWM90SPEC 1110
PWM90 series Installation Manual Connection for Blanktype AC/L(BROWN) AC/N(BLUE) V(BLACK) V(RED) DIM(WHITE) 0~10Vdc or 10V PWM or resistance Dimmer DIM(BLUE) LED Strip Cautions Before commencing any installation or maintenance work, please disconnect the power supply from the utility. Ensure that it cannot be reconnected inadvertently! Keep proper ventilation around the unit and do not stack any object on it. Also a 1015 cm clearance must be kept when the adjacent device is a heat source. Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a derating in output current. Current rating of an approved primary /secondary cable should be greater than or equal to that of the unit. Please refer to its specification. For LED drivers with waterproof connectors, verify that the linkage between the unit and the lighting fixture is tight so that water cannot intrude into the system. For dimmable LED drivers, make sure that your dimming controller is capable of driving these units.pwm series require 0.15mA each unit. Tc max. is identified on the product label. Please make sure that temperature of Tc point will not exceed limit. DO NOT connect "DIM to Vo". Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must requalify EMC Directive on the complete installation again. For more information about installation, please refer to www.meanwell.com/webnet/search/installationsearch.html for details. File Name:PWM90SPEC 1110