STRUCTURAL PERFORMANCE TEST REPORT

Similar documents
ASTM E 283, ASTM E 547, AND ASTM E 330 TEST REPORT. Rendered to: SIMPSON DOOR COMPANY

ENTRY DOOR TEST REPORT. Rendered to: The Vistawall Group

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY

TAS 201, TAS 202, TAS 203 and ASTM E330 PERFORMANCE TEST REPORT. Rendered to: DIAMOND DOOR PRODUCTS

PERFORMANCE TEST REPORT. Rendered to: GLASSCRAFT DOOR COMPANY. PRODUCT TYPE: 6' x 8' Double Inswing Hardwood Door with Half Circle Transom

MIAMI-DADE COUNTY PERFORMANCE TEST REPORT. Rendered to: FLEETWOOD WINDOWS AND DOORS Corona, California

Architectural Testing AAMA 501 TEST REPORT. Report Number: C Rendered to: Tubelite, Inc. Walker, Michigan

ASTM E 1886 and ASTM E 1996 TEST REPORT. Rendered to: PRL ALUMINUM ARCHITECTURAL PRODUCTS City of Industry, California

ASTM E1886 and ASTM E1996 TEST REPORT. Rendered to: FLEETWOOD WINDOWS AND DOORS Corona, California

ASTM E1886 and ASTM E1996 TEST REPORT. Rendered to: FLEETWOOD WINDOWS AND DOORS Corona, California

ASPEN 530 T SINGLE HUNG. Each lite of glass was channel glazed with a reducing vinyl gasket.

TESTED FOR Report No. : A04H-009 Date : February 10, 2004 FLEETWOOD ALUMINUM PRODUCTS, INC. Page : 1 of Railroad Street Corona, CA 91720

GLENWOOD 510 C Horizontal Slider

STANDARD ENTRANCES TECHNICAL MANUAL

350/500 HEAVY WALL TM IR ENTRANCES 1

REPORT OF PRODUCT EVALUATION CONDUCTED ON A

350/500 Heavy Wall TM IR Entrances

350/500 IR Entrances. Features

350/500 IR Entrances. Features

DIVISION 8 DOORS AND WINDOWS. 1. Exterior and interior single doors shall be 1-3/4 inch thick, 3 feet wide, and 7 feet high, minimum.

Finish Hardware. Contents. Section 10

This section describes the design requirements and materials/products for door hardware.

350 IR ENTRANCES INDEX

FLUSHLINE ENTRANCES. Features

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

WOOD AND CLAD COMMERCIAL DOOR WOOD AND CLAD 2 1/4 COMMERCIAL DOOR. Table of Contents

SECTION A4...IMPACT RATED ENTRANCES* 350 IR/500 IR ENTRANCES ENTRANCE HARDWARE OFFERINGS... A4/5

Series D200 Narrow Stile Series D300 Medium Stile * D500 Wide Stile ** Standard Aluminum Swing Entrance Doors

World s Leading Manufacturer Of Traffic Doors. Supplemental Instructions for the Single and Double Door Order Form

Pre-Hung Entry Door Systems

SECTION FINISH HARDWARE

2.01 Standard Entrances Description

CROSS SECTIONS OF PATIO DOORS

EXTRUTECH PLASTICS, INC. Custom Extruder of Close Tolerance Profiles

55 Series Exit Device

Flushline TM Entrances

Please read and understand all instructions before beginning. These instructions cover the non-impact aluminum French Door 101.

INSTALLATION INSTRUCTIONS. Thermal Entrances AA 250/AA 425 THERMAL DOOR WITH TRIFAB 601/601T FRAMING

PRODUCT DATA CATALOG

~ CONSTRUCTION CONSULTING LABORATORY, INTERNATIONAL

CABRIO Retractable Classic Roof / Double Rail System Step by Step Assembly Instructions

4200 Series. Commercial Exit Device

Infinity 20 Min. FIRE RATED DOORS WARNOCK HERSEY INFINITY - STANDARD RAISED - 20 MIN. RATING SOFTWOOD STILE

Andersen windows and patio doors make it easy to create a wide variety of combination designs.

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

FOLDING GLASS WALL SYSTEMS

Measuring Door Gap Dimensions of Swinging Fire Doors with Builders Hardware

INSTALLATION INSTRUCTIONS

Thermally Broken Framing and Door Installation

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

Encore 20 Min. FIRE RATED DOORS WARNOCK HERSEY ENCORE - STANDARD PANEL - 20 MIN. RATING

SECTION SWINGING AUTOMATIC ENTRANCES

V " FRP PANELS 25 PSI. POLYSTYRENE 1 8 " ⅜" TIE RODS WITH LOCKING NUTS "

Victory Fire Door Inspections

7100(F) series. A conventional exit device for single swing doors or pairs of doors of metal, wood or composite construction.

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20

October 21, 2008 MEMORANDUM. Honorable School Board Members

GENERAL INSTALLATION GUIDELINES

MANUFACTURING INC. Specifications

GENERAL INSTALLATION GUIDELINES

INSTALLATION INSTRUCTIONS CRL JACKSON

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

Chevy Chase Club June 30, 2008 Bowie Gridley Architects

Full line catalog. Locks, closers, and exits

HH Windows & Doors German engineered. American made. the horizontal pivot window

western series 9500 f loor load The Volume Program window systems westernwindowsystems.com bi fold installation instructions

Testing. Material testing will be according to applicable AASHTO, ASTM or Department methods as specified.

55 Series. Exit device

800 SERIES. Heavy-Duty Commercial Grade 1 Surface Applied Closers. Standard Features. 3 hours fire rated. openings of the door.

INSTALLATION INSTRUCTIONS FOR TEUTONIC ENTRANCE DOOR RECOMMENDATIONS FOR COMMON INSTALLATION OF ENTRANCE DOORS.

SECTION SWINGING AUTOMATIC ENTRANCES IN-GROUND, AUTOMATIC SWING DOOR OPERATOR CONVERTER ADAPTED TO BROOKFIELD NB-500 EXTREME DUTY OPERATOR

Metal Sound Retardant Door Hardware Information Bulletin

4-lite Patio Door. Installation Instructions

CONTENTS. Custom Entrances and Hardware

DIVISION Hardware

Installation Instructions. 45 and 60-Minute Fire-Rated Neutral Pressure Veneered Door Frame UBC & UL-10C

Installation Instructions. 45 and 60-Minute Positive Pressure Fire-Rated Veneered Door Frame UBC & UL-10C

Heavy Wall Applied Stop Tube Frame and Door Installation

FORCEFRONT Standard Hurricane Impact Doors and Frames Method of Ordering

STC 46 3-Sided Paired Frame (Double Rabbet Only)

EPIC. Commercial Hardware Options. Light Commercial

2100 series exit devices. rugged reliability

PRODUCT DATA CATALOG

3-LITE PATIO DOOR INSTALLATION INSTRUCTIONS

Three season porch. Touchstone Woodworks

SteelForm STANDARD, white, with oval windows. Phone: RAYNOR Fax:

series 9500 top load bi4fold installation instructions

NARROW, MEDIUM AND WIDE STILE, THERMASTILE AND DURASTILE. Installation Instructions

CRL JACKSON 900 SERIES

Solid Core Wood Door / Steel Frame Packages

TEST REPORT. Rendered to: SOLATUBE INTERNATIONAL, INC. VISTA, CALIFORNIA

FMA/AAMA/WDMA Installation Update FMA Spring Conference Duck Key, Florida April 27, 2010

AAMA Voluntary Guideline For Engineering Analysis of Window and Sliding Glass Door Anchorage Systems

custom entrances and hardware

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

8000 SERIES SERIES HEAVY-DUTY MODELS

These door closers should NOT be installed on the exposed side (weather side) of exterior doors. WOOD 3/16" 1/4"- 20

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

Transcription:

Architectural Testing STRUCTURAL PERFORMANCE TEST REPORT TEST #31 Rendered to: COMMERCIAL DOOR SYSTEMS 320 Carner Drive Bensalem, Pennsylvania 19020 Report No: 01-39570.01 Test Date: 06/14/01 Report Date: 08/03/01 Specimen Type: F500HD FRP Door with Hardware and Aluminum Frame Project Summary: Architectural Testing, Inc., (ATI) was contracted by Commercial Door Systems to conduct Air Infiltration, Water Penetration, and Uniform Load Structural tests on a Commercial Door Systems series F500HD FRP door system. Test Procedures: The test specimen was evaluated in accordance with the following: ASTM E 283, Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen. ASTM E 331, Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. ASTM E 330, Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference. Test Specimen Description: Frame Size: 3' 3-1/2" wide by 7' 1-3/4" high Door Size: 2' 11-1/2" wide by 6' 11-3/4" high Core Material: 25 psi Polystyrene Installation Description: The door was installed by Commercial Door Systems personnel into a 2 x 10 wood test frame. Each doorjamb was anchored to the test frame approximately 2", 34", 50", and 82" from the sill. Door Mainframe Construction: The stiles were 5-1/2" by 1-1/2" by 1/8" thick tubular aluminum. The top and bottom rail were 6" by 1-1/2" by 1/8" thick tubular aluminum. Comers were mortise and tenon construction, fastened using one full-length 3/8" tie rod through the bottom rail, and two full-length 3/8" tie rods through the top rail. Tie rods were secured at each end with "KBPS" lock nuts. 130 Derry Court York, PA 17 402-9405 phone: 717.764.7700 fax: 717.764.4129 www.testati.com

01-39570.01 Page 2 of2 Architectural Testing Test Specimen Description: (Continued) TEST #31 Hardware: Exit Device: Door Closer: Hinge: Threshold: Sweep: Rim type - Von Duprin 99 EO LCN 4041 Continuous hinge - PEMCO CFM83SLFHD Reese - 2483A V x 1/4" Reese - 323C Test Results: The results are tabulated as follows: Test Method Title of Test Results Allowed ASTM E283 Air Infiltration @ 1.57 psf (25 mph) @6.24 psf (50 mph) 0.31 cfm/ft 2.97 cfm/ft 2 1.25 cfm/ft 2 NIA ASTM E 331 Water Resistance Test Duration - One 15 minute Cycle WTP = 0.0 psf No entry No entry ASTM E 330 Uniform Load Structural Load Duration - 10 seconds @ +82.5 psf No damage No damage @-82.5 psf No damage No damage At a negative pressure of 84.3 psf, the latch released allowing the panel to swing open. The remedial repair consisted of adjusting the latch to its original position. A copy of this report will be retained by A TI for a period of four years. This report is the exclusive property of the client so named herein and is applicable to the sample tested. Results obtained are tested values and do not constitute an opinion or endorsement by this laboratory. For ARCHITECTURAL TESTING, INC: J McClane Technician Dadf, Director - Product/Physical Testing DAK:nlb 01-39570.01 130 Derry Court York, PA 17402-9405 phone: 717.764.7700 fax: 717.764.4129 www.testati.com

Architectural Testing STRUCTURAL PERFORMANCE TEST REPORT Rendered to: TEST #32 COMMERCIAL DOOR SYSTEMS 320 Carner Drive Bensalem, Pennsylvania 19020 Report No: 01-39569.01 Test Date: 06/14/01 Report Date: 08/03/01 Specimen Type: F200G FRP Door with Hardware and Aluminum Frame Project Summary: Architectural Testing, Inc. (A TI) was contracted by Commercial Door Systems to conduct Air Infiltration, Water Penetration, and Uniform Load Structural tests on a Commercial Door Systems series F200G FRP door system. Test Procedures: ASTM E 283, Standard Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen. ASTM E 331, Standard Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. ASTM E 330, Standard Test Method for Structural Performance of Exterior Windows, Curtain Walls and Doors by Uniform Static Air Pressure Difference. Test Specimen Description: Frame Size: 3' 3-1/2" wide by 7' 1-3/4" high Door Size: 2' 11-1/2" wide by 6' 11-3/4" high Core Material: Injected Polyurethane Installation Description: The door was installed by Commercial Door Systems personnel into a 2 x 10 wood test frame. Each door jamb was anchored to the test frame approximately 2", 24", 50", ar.u 80" from the sill. Door Mainframe Construction: The stiles and bottom rail were 2-1/2" by 1-1/2" tubular aluminum, comprised of 1/16" thick face walls and 1/8" thick end walls. The top rail was 6" by 1-1/2" by 1/8" thick tubular aluminum. Comers were mortise and tenon construction, fastened using full-length 3/8" tie rod (one per rail), secured at each end with "KEPS" lock nuts. 130 Derry Court York, PA 17402-9405 phone: 717. 764. 7700 fax: 717.764.4129 www.testati.com