Ultrasonic Controller/Sensor. Technical Information

Similar documents
MCX103A Non-Contact Rotary Position Sensor. Technical Information

ACX104B Potentiometer Rotary Position Sensor. Technical Information

S42 Pump Electrical Displacement Control (EDC)

H1B Motor Electric Proportional Control L1, L2

MP1 Pumps Non-Feedback Proportional Electric (NFPE) Control

S45 Pump Electric Proportional Control

Electrohydraulic Actuators PVEA/H/S

Tech Note Input Configurations for PLUS+1 Controllers powersolutions.danfoss.com

Sensor EMD Speed Sensor

Sensors Q625A Remote Setpoint Module

Electrohydraulic Actuator Type PVEP / PVEP-F

Technical Information Output Configurations for PLUS+1 Controllers powersolutions.danfoss.com

POWER SYSTEM MODE STATUS

Sensors ACE100B DC Millivolt Input Amplifier

MAKING MODERN LIVING POSSIBLE. Electrical Installation. Pulse Pickup KPP PPU. powersolutions.danfoss.com

MAKING MODERN LIVING POSSIBLE. Electrical Installation. M46 Pumps HC EDC. powersolutions.danfoss.com

S5X Mobile Microcomputer. Technical Information 223,5 82,25 77,75 8,5 8,5 164,5 10,3. AMP Stecker AMP Connector 52,5 POWER SYSTEM MODE STATUS

MCHXXX Control Handle

Technical Information. FDCA Fan Drive Control Assembly

Global Application Development Centers. Creating and proving solutions to customer challenges. A truly global team working for. you.

Potentiometer Control EC20200

PLUS+1 High Current Controller Family

Precision Voltage Control System

FT201 PRODUCT MANUAL PART NUMBER: SG REVISION: A

MCHXXX. Simple to install MECHANICAL. HANDLE STROKE ± 30 (60 total travel)

Series 70 Servo NXT - Modulating Controller Installation, Operation and Maintenance Manual

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

Digital amplifier for proportional valves PEM XD

Sealed Interface Control: EC20300

ELECTRONIC REGULATOR FOR OPEN LOOP

HT101V Reference Manual

Instruction. Actuator ICAD 600 / ICAD 900 / ICAD 1200 ICAD 600 ICAD 900 ICAD 1200 ICAD 600 ICAD 900. ICAD 1200 Fig. 2. Fig. 4

Proportional Directional Control Valves Nominal sizes 16 and 25

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22.

Deluxe ECM Speed Controller. ECMDX Series MANUAL INSTALLATION + SERVICE

PLA-240. Small Room Loop Amplifier System. USER Manual MAN 211A

Digital Interface Card DEC005000

Owner s Manual S10 SERIES ELECTRONIC STEP CONTROLLER WITH VERNIER CONTROL

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)

Continental Hydraulics Installation Manual CEM-PA-A

Electronic Amplifier Model VT 3017 and VT 3018 (Series 3X) for the control of proportional directional valves, without positional feedback

Coils & Electronic Controls

ASPHALT PAVING FACTORS THAT AFFECT THE SCREED

ICM/ICAD Motorized Valve. Quick Start Guide. Installation, Programming, and Trouble-shooting REFRIGERATION & AIR-CONDITIONING

RT-5005/5006/5007/5008

PRELIMINARY. Preliminary TECHNICAL DATASHEET #TDAX DC MOTOR CONTROLLER P/N: AX100650

Proportional Directional Control Valves Size 6

Analog amplifier RA. RE Edition: Replaces:

DPC-100VO. Proportional Voltage Controller. Features. Applications

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

RC3000/ RC3050 INTERFACE SPECIFICATIONS

Box chopper amplifier BOE

Ch 5 Hardware Components for Automation

DIGITAL CONTROL OF ELECTRO-HYDRAULIC STEERING TEST BENCH

THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

The Datasheet and Interfacing EE3376

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

OPERATION AND MAINTENANCE MANUAL TRIAXIAL ACCELEROMETER MODEL PA-23 STOCK NO

MICROPROCESSOR BASED CONTROLLERS

MicroManager. Velocity Mode PID Dancer/Loadcell Control. Instruction Manual MM3000-PID

Electric amplifier for flow control with proportional

Power Pulse Modulator A High Performance Versatile Square Pulse Generator

Proportional Directional Control Valves Size 6

Exercise 2: Distance Measurement

EE 314 Spring 2003 Microprocessor Systems

2 / 3 axis joystick with power outputs (PWM)

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

MiniProg Users Guide and Example Projects

MFJ ENTERPRISES, INC.

with Electronic Assistant

DLVP A OPERATOR S MANUAL

Generator Speed Controller Model GSC 1

Built-in soft-start feature. Up-Slope and Down-Slope. Power-Up safe start feature. Motor will only start if pulse of 1.5ms is detected.

Momentum and Impulse. Objective. Theory. Investigate the relationship between impulse and momentum.

IT.MLD900 SENSORS AND TRANSDUCERS TRAINER. Signal Conditioning

Continental Hydraulics Installation Manual CEM-RA-A

Power Pulse Modulator A High Performance Versatile Square Pulse Generator

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

R30D RVDTs DC-Operated Rotary Variable Differential Transformers

DPC-100LC. Proportional Valve Driver. Features. Applications

RMV25 / RMV50 RMU25 / RMU45

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

SubArc Digital Series

SubArc Digital Series

S1 Programming Chart Program Description S1 Switch Positions. Constant ON High/Low Track, WR

Blue Point Engineering

Hydraulic Valve Interface Products

Compact Hydraulic System for Energy Savings and High Precision. POWER Meister

Analog Servo Drive 25A20DD

PLEASE READ FIRST (NEW 2011 VERSION) Main features:

Actuator ICAD 600A / ICAD 600A-TS / ICAD 1200A

SSI Technologies - Application Note AT-AN3 Acu-Trac NEMA 6 Liquid Level Transmitter Product Overview

Signal Conditioning Amplifier

MicroManager. Torque Mode CTCW/Loadcell Control. Instruction Manual MM3000-CTCW

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

AE-504. Solid Start Paralleling Relay General Instructions OPERATIONS. Parallel. Control. Manual DEVICE INPUT OUTPUT

DMX-K-DRV-23 Integrated Step Motor Driver & Basic Controller

ACCUMEASURE. Non-contact Capacitance Position Measurement with Nanometer Accuracy. A worldwide leader in precision measurement solutions

Adjustable Parametric Equalizer Hardware Description

Transcription:

Ultrasonic Controller/Sensor Technical Information

Revisions Revision History Table of Revisions Date Page Changed Rev 08 Mar 2011 Cover Added PLUS+1 Compliant AB 24 Feb 2011 Replaces BLN-95-9078 AA 2011 Sauer-Danfoss. All rights reserved. 2 L1009343 Rev AB Mar 2011 Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material. Sauer -Danfoss reserves the right to alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made without affecting agreed specifications. All trademarks in this material are properties of their respective owners. Sauer-Danfoss, the Sauer-Danfoss logotype, the Sauer-Danfoss S-icon, PLUS+1, What really matters is inside and Know-How in Motion are trademarks of the Sauer-Danfoss Group.

Contents Overview Description... 4 1035019, 1035026, 1035027, 1035029, 1035036, and 1035039 Controllers... 4 1035024 Controller... 4 1035022, 1035028, 1035040, and 1035035 Sensors... 4 1035023 Sensor... 4 Features... 4 Theory of Operation... 5 Related Product... 5 Technical Data Specifications... 6 Connector Pin Definitions... 6 Configurations... 7 Dimensions... 8 Operation Operation Setup... 9 Manual Functional Test (for controllers only)... 9 Entering the Manual Test Mode... 9 Running the Five Manual Tests...10 Manual Test Staging...10 EEPROM Memory Test...10 LED Test...10 Potentiometer / LED Test...10 Ultrasonic Transceiver / LED / Output Driver Test...11 Exiting Manual Test Mode...11 System Diagram 1035019, 1035026, 1035027, 1035029, 1035030, 1035036, 1035039...12 1035024, 1035025...12 1035022 Open Circuit, 1035028 Closed Circuit, 1035035, 1035040...13 Control Diagram 1035019, 1035026, 1035027...14 1035024, 1035025...14 1035022, 1035028, 1035035, 1035040...15 L1009343 Rev AB Mar 2011 3

Overview Description The Ultrasonic Controller/Sensor has been developed to replace paddle or wand sensors. Both are non-contacting and therefore do not suffer from position or motion problems associated with standard mechanical sensors. These products are typically used to sense and control material flow. All units measure the distance to a target surface and produce a resulting output. 1035019, 1035026, 1035027, 1035029, 1035036, and 1035039 Controllers These controllers generate a signal, that varies proportionally with distance, to control an Electrical Displacement Control (EDC) for a hydrostatic transmission. Output from the controller is a pulse-width modulated, high-side switched valve drive, with a narrow proportional band. For ease of operation and mounting, the Ultrasonic Controller/ Sensor s sensing distance range can be adjusted by turning an external knob mounted on the screed or by activating the dome switches on the devices cover plate. 1035024 Controller This controller drives a solenoid-controlled three-way valve with an output that is either on (full power) when the sensor is far from the target or off (zero power) when the target is near. It s height is adjustable with a knob on the screed or by activating the dome switches on the devices cover plate. The 1035025 is identical to the 5024, except the output is inverted. 1035022, 1035028, 1035040, and 1035035 Sensors These sensors produce an analog voltage output to drive an amplifier for controlling EDCs or bi-directional valves. The output varies proportionally throughout the entire operating range. 1035023 Sensor This sensor produces a PWM output proportional to the distance from the sensor to the target. An external amplifier controls the signal for controlling EDCs or bi-directional valves. See Technical Data, Connector Pin Definitions and Configurations, pages 6 and 7. Features Non-contacting sensor Easy to mount Wide operating range Outputs to drive amplifiers or valves directly Adjustable setpoint On/Off or proportional controller; or ratiometric sensors 4 L1009343 Rev AB Mar 2011

Overview Theory of Operation The sensor element of the Ultrasonic Controller/Sensor generates an ultrasonic wave and receives a signal reflected back from the target surface. The time difference between emission and reception is proportional to distance. Sensor products output this distance signal as a voltage to an amplifier, where it is used to control a valve which varies the output speed of a hydrostatic transmission or position of a cylinder. See System Diagram, 1035022 Open Circuit, 1035028 Closed Circuit, 1035035, 1035040, page 13. The controller element of the Ultrasonic Controller/Sensor uses the same sensing head as the sensors, but provides a second control output. See System Diagram, 1035019, 1035026, 1035027, 1035029, 1035030, 1035036, 1035039, page 12. The second output is pulse-width modulated (PWM). For example., a square wave varying from input voltage (high) to zero volts (low) whose percentage of time high per cycle varies with measured distance. The PWM output is configured to drive a valve directly. Once the controller is mounted, the desired distance from the target may be varied through a dome switch located on the face plate of the device or through a remotely located potentiometer. The 1035024 output is either on (full power) or off (zero power) for use with solenoid valves, see System Diagram, 1035024 and 1035025, page 12. When the sensor is 29 cm or greater from target, when set to minimum height adjustment, power is full on until the target is 25 cm or less away, at which point power is turned off. As with other ultrasonic controllers, the desired height is adjustable through dome switches or a remote pot. As the output from the sensor/controller is varied, the hydrostatic drive varies material flow rate, resulting in the repositioning of the target. See Control Diagram, pages 14 and 15. As the target s position varies along the curves shown, the system will continually seek an equilibrium point. The 1035026 and 1035022 have proportional outputs that normally produce a continuous output, resulting in uniform speed control of the material flow mechanism. The 1035024 may produce intermittent stop and start of the material flow. Typical applications for the Ultrasonic Controller/Sensor include: control of auger/ conveyor drive speed on asphalt pavers, position control of strike-off gates on feed for asphalt or concrete pavers, position control of contour mechanisms and remote measurement and monitoring. Related Product Accessories KE14010 Feeder Control Amplifier KW01028 Cable KW01009 Cable KW01029 Cable A printed circuit board, the KE14010 accepts a signal from an 1035022 or an MCX102A Potentiometer Sensor and actuates an Electrical Displacement Control (EDC) on a hydrostatic pump. Connects 1031097, 1035026 or 1035024 to machine bulkhead. MS connectors on both ends. Six socket on sensor end, five socket on machine end. Three conductors. Two-foot coil cord stretches to ten feet. Connects 1035026 or 1035024 to machine bulkhead. MS connectors on both ends. Six socket on both ends. Four conductors. Two-foot coil cord stretches to ten feet. Connects 1035022 to MCP112A1011. MS connectors on both ends. Six socket on sensor end, five socket on controller end. Three conductors. Twofoot coil cord stretches to ten feet. Plug compatible with MCX102A1004. 1031109 Cable Connects 1035026 or 1035024 to machine bulkhead. MS connectors on both ends. Six socket on both ends. Four conductors. One and half-foot coil cord stretches to seven and half feet. 1035060 Remote Pot Installs a potentiometer into the system. L1009343 Rev AB Mar 2011 5

Technical Data Specifications Continuous operating temperature 14 to 158 F (-10 to 70 C) Supply voltage 10 to 30 Vdc Operating range Proportional valve drive output (1035026) Valve drive frequency (1035026) ON/OFF valve drive output (1035024) Control band (1035024) Analog output (1035022) Output impedance for analog output 16 to 100 cm (6.3 to 39.4 in) varies by model. 0 240 ma (12 Vdc into a 20 ohm load) 0 240 ma (24 Vdc into a 80 ohm load) high-side switched 1000 Hz, pulse-width modulated 2.0 amp maximum into a 7 ohm minimum load High side switched 4 cm (1.6 in) 1.5 Vdc at 6.3 inches (16 cm) 8.5 Vdc at 39.4 inches (100 cm) 1000 ohms, minimum Connector Pin Definitions Part number Connector pin definitions A B C D E F 1035019 BATT (+) POT (-) BATT (-) PWM output POT feedback POT (+) 1035022 BATT (+) DC output BATT (-) Not used Not used Not used 1035023 BATT (+) BATT (-) PWM output BATT (-) Not used Not used 1035024 BATT (+) POT (+) BATT (-) ON/OFF output POT (-) POT feedback 1035025 BATT (+) POT (+) BATT (-) ON/OFF output POT feedback N/A 1035026 BATT (+) POT (+) BATT (-) PWM output POT (-) POT feedback 1035027 BATT (+) POT (-) BATT (-) PWM output POT feedback POT (+) 1035028 BATT (+) DC output BATT (-) Not used Not used Not used 1035029 BATT (+) POT (+) BATT (-) PWM output POT(-) POT feedback 1035030 BATT (+) POT (+) BATT (-) PWM output POT (-) POT feedback 1035035 BATT (+) BATT (-) DC output Not used Not used N/A 1035036 BATT (+) POT (-) BATT (-) PWM output POT feedback POT (+) 1035039 BATT (+) POT (-) BATT (-) PWM output POT feedback POT (+) 1035040 BATT (+) DC output BATT (-) Not used Not used Not used 6 L1009343 Rev AB Mar 2011

Technical Data Configurations Part number Configurations Sensing range Control range Control type Output frequency Output impedance 1035019 25 to 100 cm (9.8 to 39.4 in) 1035022 16 to 100 cm (6.3 to 39.4 in) 1035023 20 to 91 cm (8.0 to 36.0 in) 1035024 29 to 100 cm (11.5 to 39.5 in) 1035025 29 to 100 cm (11.5 to 39.5 in) 1035026 29 to 100 cm (11.5 to 39.5 in) 1035027 25 to 100 cm (9.8 to 39.4 in) 1035028 16 to 100 cm (6.3 to 39.4 in) 1035029 29 to 100 cm (11.5 to 39.5 in) 1035030 29 to 100 cm (11.5 to 39.5 in) 1035035 16 to 100 cm (6.3 to 39.4 in) 1035036 20 to 100 cm (7.9 to 39.4 in) 1035039 20 to 100 cm (7.9 to 39.4 in) 1035040 16 to 100 cm (6.3 to 39.4 in) 30 cm (11.8 in) Proportional PWM High-side switching N/A Ratiometric 1.5 to 8.5 Vdc N/A Ratiometric Low-side switching 4 cm (1.6 in) ON/OFF High-side switching 4 cm (1.6 in) ON/OFF High-side switching (inverted) 20 cm (8.0 in) Proportional PWM High-side switching 10 cm (3.94 in) Proportional PWM High-side switching N/A Ratiometric 0.5 to 4.5 Vdc 30 cm (11.8 in) Proportional PWM High-side switching 20 cm (8.0 in) Proportional PWM High-side switching N/A Ratiometric 1.5 to 8.5 Vdc 25 cm (9.8 in) Proportional PWM High-side switching 40 cm (15.75 in) Proportional PWM High-side switching N/A Ratiometric 0.5 to 4.5 Vdc Loss-of-signal output 200 Hz 180 Ohms Augers ON Yes DC 1000 Ohms Sends far target voltage (Augers ON) No 5000 Hz 250 Ohms Augers ON No ON/OFF 0 Ohms Augers ON Yes ON/OFF 0 Ohms Augers ON No 1000 Hz 25 Ohms (0 to 240 ma into 20 Ohms @ 12 Vdc, 80 Ohms @ 24 Vdc) Augers ON Yes 200 Hz 180 Ohms Augers ON Yes DC 1000 Ohms Sends close target voltage (Augers OFF) No 1000 Hz 0 Ohms Augers ON Yes 1000 Hz 0 Ohms Augers ON Yes DC 1000 Ohms Sends far target voltage (Augers ON) No 1000 Hz 0 Ohms Augers ON Yes 12% Min. Duty Cycle (98% Max) 112 Hz 200 to 600 ma 4 Ohms Augers ON for 5 seconds then off DC 1000 Ohms Sends far target voltage (Augers ON) Remote pot Yes No L1009343 Rev AB Mar 2011 7

Technical Data Dimensions mm [in] 77.22 [3.04] 102.62 [4.04] 144.32 [5.68] 84.90 [3.34] 44.45 [1.75] 96.52 [3.80] 107.75 [4.24] P200 056 8 L1009343 Rev AB Mar 2011

Operation Operation Setup 1. 2. 3. 4. 5. 6. 7. 8. 9. Pressing both dome switches simultaneously will set the high level of the material at the current height (establishes the set-point). Each push of a dome switch will change the material height approximately 0.5 cm (0.2 in). Pushing an increase or decrease button will move the fixed control-band within the working area. The PWM output is linear from 0% to 100% over the control band. If the target is lost or out-of-range, the device will scroll three LEDs up-and-down the LED bar-graph. For controllers, the LED bar-graph shows the set-point. For sensors, the LED bar-graph shows the material height. If a potentiometer is connected, it takes priority over the push-button switches and the push-button switches are deactivated. However, the push-button switches may still be used to enter the manual test. The latest set-point is saved in memory and will be stored if power is lost, and restored when power is turned back on. Manual Functional Test (for controllers only) The Ultrasonic Controller/Sensor has resident software to perform a manual test any time that the device operation is suspect Entering the Manual Test Mode 1. Test mode is entered by simultaneously pressing both membrane switch buttons (the increase-button and the decrease-button). 2. 3. Continue holding the decrease-button (-), and release the increase-button (+). Next, press the increase-button (+) ten additional times, while continuing to hold the decrease-button (-). When you have successfully completed this sequence, the transducer will stop transmitting the ultrasonic bursts, and the 10 LEDs, in the LED bar graph, will start a motion pattern that will start moving from the ends of the bar graph to the center of the bar graph. This is the signal that you have successfully entered the manual test mode. While entering test mode, you have successfully exercised the membrane switches. The procedure for entering test mode, as well pressing the buttons to navigate within the manual test, serves as the membrane switch test. L1009343 Rev AB Mar 2011 9

Operation Running the Five Manual Tests Manual Test Staging 1. Release both push-button switches. You are now at the first step within the manual test. This is a staging step that can be recognized by the sequence of the flashing LED display. 2. 3. To run the next test, press the decrease-button once. To run a previous test, press the increase-button one time. Move to first test, last test, and back again by simultaneously pressing the increasebutton and the decrease-button EEPROM Memory Test 1. Press and release the decrease-button one time to run this test. The micro-controller will autonomously run the EEPROM test. 2. 3. A successful completion of the test will result in all LEDs being on. If this test fails, then all LEDs will flash. If the LEDs flash, then one or more EEPROM locations are not capable of being reprogrammed. LED Test will re-run by pressing and releasing increase-button. LED Test 1. Press and release the decrease-button one time to begin this next test. 2. 3. Upon entry into this test, each LED will turn on, and then off again, in sequence. The operator must verify that each individual LED in the bar-graph is functional. At no time should two LEDs be on simultaneously. EEPROM Memory Test will re-run by pressing and releasing increase-button. Potentiometer / LED Test 1. Press and release the decrease-button one time to begin this test. 2. 3. If the device is capable of being equipped with a potentiometer, then turning the pot will change the lights on the display. Depending on how the pot is connected, turning it fully one direction will result in all LEDs on. Turning it all the way in the other direction will result in all LEDs off, except for LED 0 (the least significant LED in the LED bar graph). LED 0 will always be on during this test. As the LED bar-graph increases in length, the output from the PWM connection will increase, as well. 10 L1009343 Rev AB Mar 2011

Operation Running the Five Manual Tests (continued) Potentiometer / LED Test (continued) 4. If no potentiometer is connected, then some arbitrary output will result along with some arbitrary LED display. Caution If the paver s augers are set in an automatic mode, then running this test will turn the augers. Potentiometer / LED Test will rerun by pressing and releasing the increase-button. Ultrasonic Transceiver / LED / Output Driver Test 1. Press and release the decrease-button one time to enter this test. The ultrasonic transducer will now activate and start transmitting signals and receiving the echoes. The transducer must be pointed toward a suitable target to complete this test. Also, there must be an appropriate method of measuring the PWM output from the valve driver. 2. 3. As the device is moved toward the target, the PWM output will either go to its minimum duty cycle or its maximum duty cycle, depending on the device configuration. As the device is moved away from the target, the PWM output will go to its maximum duty cycle or its minimum duty cycle, depending on the device configuration. As the device moves away from the target, the LED display will go from all LEDs on to all LEDs off, except for the least significant LED in the array. LED 0 is always on during this test. Caution If the paver s augers are set in an automatic mode, then running this test will turn the augers. Ultrasonic Transceiver / LED / Output Driver Test will re-run by pressing and releasing increase-button. Exiting Manual Test Mode 1. Pressing and releasing the decrease-button one time will allow the Ultrasonic Controller/Sensor to enter this test. 2. You will be able to recognize this test by observing the transducer and the LED bar graph. The transducer will stop transmitting and the 10 LEDs, in the LED bar graph, will start a motion pattern that will start moving from the ends of the bar graph to the center of the bar graph. Exiting Manual Test Mode will re-run by pressing and releasing increase-button. Manual Test Mode is exited and normal operation resumes by simultaneously pressing the increase-button and the decrease-button L1009343 Rev AB Mar 2011 11

System Diagram 1035019, 1035026, 1035027, 1035029, 1035030, 1035036, 1035039 Coil Cord Optional Remote Adjust Pot Machine Bulkhead Machine Wiring Ultrasonic Target Surface Material Flow Auger Hydrostatic Transmission Electrical Displacement Control P200 058 1035024, 1035025 Coil Cord Optional Remote Adjust Pot Machine Bulkhead Machine Wiring Ultrasonic Controller 3-way Valve Material Flow Target Surface Auger MF SNP2 Gear Pump P200 059 12 L1009343 Rev AB Mar 2011

System Diagram 1035022 Open Circuit, 1035028 Closed Circuit, 1035035, 1035040 Coil Cord Panel or Controller Machine Wiring Ultrasonic Sensor Optional Wand Sensor Target Surface Material Flow Auger Hydrostatic Transmission Electrical Displacement Control P200 060 L1009343 Rev AB Mar 2011 13

Control Diagram 1035019, 1035026, 1035027 Control range of the pulse-width modulated output (pin D). 240 Output Current (ma) 200 160 120 80 Distance Adjust Knob Full Clock Height adjust Full Counter-Clock Distance Adjust Knob 12 Vdc Supply 40 0 0 20 40 60 80 100 Distance from Target (cm) P200 061 1035024, 1035025 Control range of the ON/OFF output (pin D). Distance Adjust Knob Full Clockwise Full Counter-Clockwise Height Adjust Power Output drive 12 Vdc Supply Open 0 26 30 76 80 Distance from target (cm) P200 062 14 L1009343 Rev AB Mar 2011

Control Diagram 1035022, 1035028, 1035035, 1035040 Control range of the analog output (pin B) for the 103522, 1035028 Ultrasonic Control/Sensor. Supply voltage is 12 or 24 Vdc and output impedances 1 k ohm. 8.0 1035022, 1035035 Output voltage (Vdc) 6.0 4.0 2.0 1035028, 1035040 0 0 20 40 60 80 100 Distance from target (cm) P200 063 L1009343 Rev AB Mar 2011 15

Bent Axis Motors Closed Circuit Axial Piston Pumps and Motors Displays Electrohydraulic Power Steering Electrohydraulics Hydraulic Power Steering Integrated Systems Joysticks and Control Handles Microcontrollers and Software Open Circuit Axial Piston Pumps Orbital Motors PLUS+1 GUIDE Proportional Valves Sensors Steering Transit Mixer Drives Sauer-Danfoss is a global manufacturer and supplier of highquality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of off-highway vehicles. We can help speed up system development, reduce costs and bring your vehicles to market faster. Sauer-Danfoss Your Strongest Partner in Mobile Hydraulics. Go to www.sauer-danfoss.com for further product information. Wherever off-highway vehicles are at work, so is Sauer-Danfoss. We offer expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components. Members of the Sauer-Danfoss Group Local address: Comatrol www.comatrol.com Schwarzmüller-Inverter www.schwarzmueller-inverter.com Turolla www.turollaocg.com Sauer-Danfoss (US) Company 2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000 Fax: +1 515 239 6618 Sauer-Danfoss ApS DK-6430 Nordborg, Denmark Phone: +45 7488 4444 Fax: +45 7488 4400 Hydro-Gear www.hydro-gear.com Sauer-Danfoss-Daikin www.sauer-danfoss-daikin.com Sauer-Danfoss GmbH & Co. OHG Postfach 2460, D-24531 Neumünster Krokamp 35, D-24539 Neumünster, Germany Phone: +49 4321 871 0 Fax: +49 4321 871 122 Sauer-Danfoss-Daikin LTD. Shin-Osaka TERASAKI 3rd Bldg. 6F 1-5-28 Nishimiyahara, Yodogawa-ku Osaka 532-0004, Japan Phone: +81 6 6395 6066 Fax: +81 6 6395 8585 L1009343 Rev AB Mar 2011 www.sauer-danfoss.com