Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Similar documents
Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

General Catalogue. Quality made in D946E182

Index. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Capacitor Switching Contactors

Micro-Contactors LAM ONLINE SHOPPING! Get Ready. Get Schrack. In the office and on the go with the Live Phone App.

General 2 Approvals 3 Technical Information 5 Mounting Information 6

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Controls Contactors and Contactor Assemblies Special Applications

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

NS..S contactor relays - with spring terminals AC operated

Characteristics 5 TeSys k contactors and reversing contactors

Output of three-phase motors at 50 Hz and 400 V

Contactors and Contactor Assemblies

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Mini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

For non-electrical quantities

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

Type: DILEM 10 G(24VDC) Article No.:

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

LC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

XT IEC Power Control Miniature Controls

LC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Open Type Without Enclosure

NZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

Type CP-S, CP-C & CP-A Switch mode

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

3 - Protection components Circuit-breakers

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

PKZ 2 Manual Motor Protectors Technical Data

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Ratings for Switching AC Motors AC-2, AC-3, AC / /

Ratings for Switching AC Motors AC-2, AC-3, AC / /

Open Type Without Enclosure

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

62 Series - Power relays 16 A. Features / /

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

77 Series - Modular Solid State Relay 5 A. Features. Timers and Monitoring relays

Miniature circuit-breakers S 280 UC series. System pro M. Technical data

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

2 pole (1 NO + 1 NC) 1 NO + 1 NC 2 NO + 2 NC, 3 NO + 1 NC 4 NO + 2 NC Rated current / Max. peak current Rated load AC1

Miniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays

48 Series - Relay interface modules A. Features

Modular equipment. Presentation, standards. Standard contactors TeSys GC

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

Compact size 2 Form A and 2 Form A 1 Form B 35A power relays for energy management and industrial equipment. Conditions. Mirror contact mechanisms

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

62.22 Copper side view

Control relays. K mini-control relays. 2 or 4 for CA2-K and CA3-K: 2 for CA4-K. Conforming to VDE 0110 group C V 750

Motor starters. TeSys E. Designed for the essential

Thermistor motor protection relays

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947

Semiconductor contactors, Solid-state relays

2 Pole CO, 8 A Plug-in 2 CO (DPDT) 1 CO (SPDT) 8/15 16/25* 250/ /400 2,000 4, /0.5/ /0.5/ (5/5) 300 (10/5)

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

48 SERIES. Relay interface modules 8 A CO forcibly guided contacts relay interface modules,15.8 mm wide Type 48.12

30 A rated contacts Flange mount Faston 250 connections. 30 A rated contacts PCB mount - bifurcated terminals. Copper side view

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

Safety switches with slotted hole lever

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

Installation / Monitoring Technique

E-STOP relays, safety gate monitors

Description Basic devices with positive operation contacts

62 Series - Power relays 16 A. Features SERIES / / Printed circuit mount 16 A Power relay

Switching Devices Contactors and Contactor Assemblies for Switching Motors

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

3RH1 contactor relays, 4- and 8-pole

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

3.5 mm contact pin pitch 1 Pole 12 A PCB direct or via socket

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Series P. Applications

Modular Devices and Enclosures

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Datasheet - PROTECT-IE-02

Miniature Power Relay MSR

IMPULSE SWITCH, REMOTE SWITCH

Selection tables Command devices E 250 latching relays

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Transcription:

Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9

Micro Contactor Relays 4-pole AC Operated RatingsTherm. Contacts 2) Type Coil voltage 1) Distinc. Additional 24 24V 50/60Hz Number Contact 230 220-240V 50Hz/60Hz AC15 Rated- Current 230V 400V I th acc. to Blocks Pack Weight A A A NO NC EN50011 Type pcs. kg/pc. 4-pole, With Screw Terminals 3 1,5 5 4-40E - K0-04D40... 10 0,07 3 1,5 5 3 1 31E - K0-04D31... 10 0,07 3 1,5 5 2 2 22E - K0-04D22... 10 0,07 K0-04D40 K0-04D31 K0-04D22 1) Other coil voltages on request. 2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA). Mirror contacts acc. IEC60947-4-1 Annex F. 10 D946E

AC Operated Power Ratings Rated Aux. Contacts 2) Type Coil voltage 1) Current Built-in Additional 24 24V 50/60Hz 230 220-240V 50Hz/60Hz AC2, AC3 AC1 380V 400V 660V 415V 690V 440V Pack Weight kw kw A NO NC Type pcs. kg/pc. 3-pole, With Screw Terminals 2,2-12 1 - - K0-05D10... 10 0,07 2,2-12 - 1 - K0-05D01... 10 0,07 4-pole, With Screw Terminals 2,2-12 - - - K0-05D00-40... 10 0,07 K0-05D10 K0-05D01 K0-05D00-40 Snap-On Adapter For Type Specification Type Pack Weight pcs.. kg/pc. K0 for snap-on mounting of P1039 10 0,0061 Snap on Adapter for K0 accessories on 35mm DIN-rail acc. DIN EN 50022 1) Other coil voltages see page 12. 2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA). Mirror contacts acc. IEC60947-4-1 Annex F. D946E 11

AC Operated Power Ratings Rated Aux. Contacts 2) Type Coil voltage 1) Current Built Additional 24 24V 50/60Hz in 230 220-240V 50Hz/60Hz AC2, AC3 AC1 380V 400V 660V 415V 690V 440V Pack Weight kw kw A NO NC Type pcs. kg/pc. 3-pole, with Solder Pins Ø1,15 for Printed Circuit Applications 2,2-9 1 - - K0-05L10... 10 0,07 2,2-9 - 1 - K0-05L01... 10 0,07 4-pole, with Solder Pins Ø1,15 for Printed Circuit Applications 2,2-9 - - - K0-05L00-40... 10 0,07 K0-05L10 K0-05L01 K0-05L00-40 Coil voltages for AC operated contactors Suffix Voltage Marking Rated Control Voltage U s to contactor at the coil range type for for for 50Hz for 60Hz e.g. 50Hz 60Hz min. max. min. max. K0-05D10 24 V V V V V V 12 12 12 11 12 12 12 24 24 24 22 24 24 24 42 42 42 38,5 42 42 42 48 48 48 48 50 48 52 90 100 100 90 100 100 105 95 95-100 105-110 95 100 105 110 100 100 110-115 100 105 110 115 105 105-110 115-120 105 110 115 120 110 110-115 120-125 110 115 120 125 180 200 200 185 200 200 210 Suffix Voltage Marking Rated Control Voltage U s to contactor at the coil range type for for for 50Hz for 60Hz e.g. 50Hz 60Hz min. max. min. max. K0-05D10 230 V V V V V V 200 200 200-220 195 205 200 220 210 205-215 220-230 205 215 220 230 220 210-220 220-240 210 220 220 240 230 220-230 230-250 220 230 230 250 240 230-240 230 240 250 260 Standard voltages in bold type letters Operating range of magnet-coils: 0,85 x U s (min. value of rated control voltage) up to 1,1 x U s (max. value of rated control voltage) Coil not exchangeable 1) Other coil voltages see page 12. 2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA). Mirror contacts acc. IEC60947-4-1 Annex F. 12 D946E

Micro Reversing Contactors, Mechanical Interlocked AC Operated Power Ratings Rated Aux. Contacts 2) Type Coil voltage 1) Current Built-in Additional 24 24V 50/60Hz on left on right 230 220-240V 50Hz/60Hz hand side hand side AC2, AC3 AC1 Contactor Contactor 380V 400V 660V 415V 690V 440V K1 K2 Pack Weight kw kw A NO NC Type Type pcs. kg/pc. 3-pole, with Screw Terminals 2,2-12 - 1 - - K0W05D01MC... 1 0,14 2,2-12 1 - - - K0W05D10MC... 1 0,14 4-pole, with Screw Terminals 2,2-12 - - - - K0W05D00-40MC... 1 0,14 3-pole, with Solder Pins Ø1,15 for Printed Circuit Applications 2,2 - xxx 3) - 1 - - K0W05L01MC... 1 0,14 2,2 - xxx 3) 1 - - - K0W05L10MC... 1 0,14 K0W05D01MC K0W05D10MC K0W05D00-40MC 1) Other coil voltages see page 12. 2) Contacts suitable for electronic circuits, according to EN947-5-4 for rated voltage 24V DC (test ratings 17V DC, 5mA). Mirror contacts acc. IEC60947-4-1 Annex F. 3) Data on request. D946E 13

Data according to IEC 60947-4-1, VDE 0660, EN 60947-4-1 Main Contacts Type K0-05D.. K0-05L.. Rated insulation voltage U i V AC 440 1) 440 1) Making capacity I eff at U e = 440V AC A 65 65 Breaking capacity I eff 400V AC A 50 50 cosϕ = 0,65 Utilization category AC1 Switching of resistive load (=I th ) at 40 C, open A 12 9 Rated operational power of three-phase resistive loads 230V kw 4,7 3,5 50-60Hz, cosj = 1 240V kw 4,8 3,7 400V kw 8,3 3,3 415V kw 8,6 6,4 440V kw 9,0 6,8 (=I th ) at 60 C, enclosed A 8 6 Rated operational power of three-phase resistive loads 230V kw 3,1 2,3 50-60Hz, cosj = 1 240V kw 3,3 2,4 400V kw 5,5 4,1 415V kw 5,7 4,3 440V kw 6,0 4,5 Minimum cross-section of conductor at load with I e (=I th ) mm² 1,5 - Utilization category AC2 and AC3 Switching of three-phase motors 220V A 6,2 6,2 open and enclosed 230V A 6,2 6,2 240V A 5,6 5,6 380-400V A 5 5 415-440V A 5 5 Rated operational power of three-phase motors 220-240V kw 1,5 1,5 50-60Hz 380-440V kw 2,2 2,2 Utilization category AC4 Switching of squirrel cage motors, inching 220V A 4,9 4,9 open and enclosed 230V A 4,9 4,9 240V A 4,1 4,1 380-400V A 3,5 3,5 415-440V A 3,5 3,5 Rated operational power of three-phase motors 220-240V kw 1,1 1,1 50-60Hz 380-440V kw 1,5 1,5 Utilization category AC5a Switching of gas discharge lamps per pole at 220/230V Fluorescent lamps, uncompensated and serial compensated A 6 6 parallel compensated A 0,5 0,5 dual-connection A 9 9 Metal halide lamps 2), uncompensated A 6 6 parallel compensated A 0,5 0,5 Mercury-vapour lamps 3), uncompensated A 9 9 parallel compensated A 0,5 0,5 Mixed light lamps 4) A 9 9 LED-Lamps inrush current of contactor consider the inrush current of the lamp ballast max. lamps per pole (I nled I th )= and cosϕ of the lamp inrush current of lamp/evg max inrush current of contactor A 91 91 Utilization category AC5b Switching of incandescent lamps 5) per pole at 220/230V A 3 3 1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 4kV. Data for other conditions on request. 2) Metal halide lamps and sodium-vapour lamps (high- and low-pressure lamps) 3) High-pressure lamps 4) Blended lamps, containing a mercury high-pressure unit and a tungsten helix in a flourescent glass bulb (daylight lamps) 5) Current inrush approx. 16 x Ie 14 D946E

Data according to IEC 60947-4-1, VDE 0660, EN 60947-4-1 Main Contacts Type K0-05D.. K0-05L.. Utilization category DC1 Switching of resistive load 1 pole 24V A 12 9 Time constant L/R 1ms 60V A 12 9 110V A - - 220V A - - 3 poles in series 24V A 12 9 60V A 12 9 110V A 12 9 220V A - - Utilization category DC3 and DC5 Switching of shunt motors 1 pole 24V A 12 9 and series motors 60V A - - Time constant L/R 15ms 110V A - - 220V A - - 3 Pole in Serie 24V A 12 9 60V A 12 9 110V A 12 9 220V A - - Maximum ambient temperature Operation open C -40 to +60 (+90) 1) enclosed C -40 to +40 with therminal overload relay open C -25 to +60 enclosed C -25 to +40 Storage C -50 to +90 Short circuit protection for contactors without thermal overload relay Coordination-type "1" according to IEC 947-4-1 Contact welding without hazard of persons max. fuse size gl (gg) A 20 20 Coordination-type 2 according to IEC 947-4-1 Light contact welding accepted max. fuse size gl (gg) A - - Contact welding not accepted max. fuse size gl (gg) A - - For contactors with thermal overload relay the device with the smaller admissible backup fuse (contactor or thermal overload relay) determines the fuse size. Cable cross-sections for contactors main connector solid or stranded mm² 0,5-1,5 Solder Connector flexible mm² 0,5-1,5 Ø 1,15 flexible with multicore cable end mm² 0,5-1,5 Cables per clamp 2 - solid or stranded AWG 20-14 Frequency of operation z without load 1/h 10000 10000 contactors without therminal oberload relay AC3, I e 1/h 600 600 AC4, I e 1/h 120 120 DC3, I e 1/h 600 600 Mechanical life AC operated S x10 6 3 3 DC operated S x10 6 xxx 2) xxx 2) Short time current 10s-current A 50 50 Power loss per pole at I e /AC3 400V W 0,2 0,2 Resistance to shock according to IEC 68-2-27 Shock time 20ms sine-wave AC operated NO g 2,5 2,5 NC g 2,5 2,5 1) With reduced control voltage range 0,9 up to 1,0 x U s and with reduced rated current I e /AC1according to I e /AC3. 2) Data on request. D946E 15

Data according to IEC 60947-5-1, VDE 0660, EN 60947-5-1 Auxiliary Contacts Type K0-04D.. K0-05D.. K0-04L.. K0-05L.. Rated insulation voltage U i VAC 440 1) 440 1) Thermal rated current I th bis 440V Ambient temperature 40 C A 5 5 60 C A 3 3 Verlustleistung pro Pol bei I th W 0,25 0,25 Utilization category AC15 Rated operational currrent I e 220-240V A 3 3 380-415V A 1,5 1,5 440V A 1 1 Utilization category DC13 60V A 0,5 0,5 - - - - Maximum ambient temperature Operation open C -40 to +60 (+90) 2) enclosed C -40 to +40 Storage C -40 to +90 Short circuit protection short-circuit current 1kA, contact welding not accepted max. fuse size gl (gg) A 10 10 For contactors with thermal overload relay the device with the smaller admissible control fuse (contactor or thermal overload relay) determines the fuse size. Power consumption of coils AC operated inrush VA 9 9 sealed VA 4 4 W 1,8 1,8 Operation rage of coils in multiples of control voltage U s 0,85-1,1 0,85-1,1 Switching time at control voltage U s ±10% 3) 4) AC operated make time ms 13-18 13-18 release time ms 5-10 5-10 arc duration ms 10-15 10-15 DC operated make time ms - release time ms - arc duration ms - Cablecross-section all connectors solid mm 2 0,5-1,5 Solder Connector flexible mm² 0,5-1,5 Ø 1,15 flexible with multicore cable end mm 2 0,5-1,5 Clamps per pole 2 - solid or stranded AWG 20-14 - 1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 4kV. Data for other conditions on request. 2) With reduced control voltage range 0,9 up to 1,0 x U s and with reduced thermal rated current I th to I e /AC15. 3) Summary switching time = release time + arc duration. 4) Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (Varistor, RC-units, Diode units). 5) Data on request. 16 D946E

for North America Data according to UL508 ½ - Main Contacts (culus) Type K0-05D.. K0W05D01.. K0-04D.. K0-05L.. K0-04L.. Rated operational current "General Use" A 12 5 9 5 Rated operational power of three motors 110-120V hp ½ - ½ - at 60Hz (3ph) 200-208V hp 1-1 - 220-240V hp 1-1 - 277V hp 1½ - 1½ - Rated operational power of AC motors 110-120V hp ½6 - ½6 - at 60Hz (1ph) 200-208V hp ½ - ½ - 220-240V hp ¾ - ¾ - Fuse / Short-circuit current A/kA 30/5-30/5 - Rated voltage VAC 300 300 300 300 Auxiliary Contacts (culus) heavy pilot duty AC B300 B300 B300 B300 standard pilot duty DC R300 R300 R300 R300 Motor Rating Motor Rating Breaking Current P n = AC4 P n I a e A Millions of Operations D946E 17

Dimensions AC operated with screw terminals Snap-On Adapter P1039 K0-04D.. K0-05D.. Reversing Contactors with screw terminals K0-..D.. with Snap-On Adapter P1039 K0W05D..MC AC operated with solder connections K0-04L.. K0-05L.. Reversing Contactors with solder connections K0W05L..MC 18 D946E