Indumax H CLS54. Technical Information

Similar documents
Indumax CLS54D. Technical Information

Technical Information Indumax CLS54

Smartec S CLD134. Technical Information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Technical Information Smartec CLD18

Indumax CLS50/CLS50D. Technical Information

Condumax W CLS15 and CLS15D

Condumax CLS16 and CLS16D

Technical Information Smartec CLD18

Technical Information Indumax CLS50D/CLS50

Technical Information Smartec CLD18

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Technical Information Memosens CLS82D

Condumax CLS21 and CLS21D

Condumax CLS15 and CLS15D

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Condumax W CLS15 and CLS15D

Condumax CLS21 and CLS21D

Condumax CLS15 and CLS15D

Technical Information Condumax CLS21D/CLS21

Technical Information Condumax CLS15D/CLS15

Orbipac CPF81/CPF82 and CPF81D/CPF82D

Conductivity measurement SmarTec S CLD 132

Ceramax CPS341D. Technical Information

Conductivity Sensor for High-Temperature Applications ConduMax W CLS 13

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

Memosens New technology for contactless, inductive, digital transmission of ph signals

Inductive conductivity measurement mypro CLM 431 / CLD 431 inductive

Conductivity sensor for hygienic applications

Technical Information Liquisys M CLM223/253

OPTIFLUX 5000 Technical Datasheet

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

OPTIFLUX 5000 Technical Datasheet

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Liquisys M CLM223/253

Process display RIA 261

Inductive conductivity transmitter JUMO CTI-Junior

Inductive Conductivity Meter ILM

Technical Information Orbipore CPS91D and CPS91

The transducer component converts the measured signal and displays the actual value.

Soliphant T FTM20, FTM21

Smartec S CLD134. Operating Instructions. Conductivity Measuring System. BA401C/07/en/ Software version 1.

Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H

Liquisys M CCM223/253

Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive

Digital conductivity transmitter

Technical Information OUSBT66

Technical Information Orbipac CPF81D/CPF82D and CPF81/CPF82

Liquisys M COM223/253

Magnetic-Inductive flow Meter fmi

Conductivity measurement Mycom S CLM 153

Pressure transmitter For sanitary applications Model SA-11

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Memosens CPS96D. Technical Information

Liquisys M CPM223/253

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

In-Line Resistance Thermometers Model TR25

Tophit CPS441 and CPS441D

OPTIFLUX 1000 Technical Datasheet

ph / ORP Measurement mypro CPM 431

Digital inductive conductivity transmitter

Memosens Make the most of your process with better analysis quality and lower operating costs

Tophit CPS491 and CPS491D

Technical Information Memosens CPS96D

Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts. Temperature sensor. Graphics LC display.

TH27. Technical Information. Hygienic thermowell assemblies with spring loaded RTD insert

Submersible pressure sensor For oils and fuels Model LF-1

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Rosemount 225. Toroidal Conductivity Sensors. Product Data Sheet July Toroidal Conductivity Sensor LIQ-PDS-225

Temperature transmitter itemp RTD DIN rail TMT 127

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

omnigrad M TR 46 Technical Information Hygienic in-line RTD thermometer PCP ( ma), HART or PROFIBUS-PA electronic

OPTISENS ORP 8590 Technical Datasheet

Conductivity Measurement mycom CLM 152

Radiometric Measurement DG 57 scintillation detectors

Sterilizable IsFET sensor for ph Measurement TopHit CPS 441

Submersible pressure sensor For water and wastewater Model LW-1

Submersible pressure sensor For superior applications Model LF-1

RTD TH17 and TH18. Technical Information. Sanitary RTD temperature assembly with enclosure

Flow Measurement SITRANS F M

Electromagnetic Flow Transmitter

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

SMARTPAT COND 1200 Technical Datasheet

In-line resistance thermometer Model TR25

IsFET sensor for ph Measurement TopHit CPS 491

Electromagnetic Flowmeter Hygienic/Sanitary

Fluke 712B and 714B Temperature Calibrators

Turbidity sensor TurbiMax W CUS 41

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

BATCHFLUX 5500 C Technical Datasheet

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Temperature transmitter itemp PCP DIN rail TMT 121

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Conductivity-Converter

High-quality pressure transmitter For general industrial applications Model S-10

Conductivity Transmitter

INLINE flowmeter for continuous flow measurement

FLOWave SAW-Flowmeter

OPTISENS PH 8390 Technical Datasheet

Transcription:

N & Technical Information Indumax H CLS54 Inductive conductivity sensor with hygienic design for applications in the food, beverage and life science industries Application The CLS54 conductivity sensor is specifically intended for use in hygienic applications in the food, beverage and pharmaceutical industries and in biotechnology. Thanks to its food-grade virgin PK body, its jointless and creviceless design and its hygienic certificates, it meets the extremely exacting demands of these industries. The CLS54 is especially suitable for the following applications: Phase separation of product/water and product/product mixtures in pipe systems Control of CIP (cleaning in place) processes in the return channel Concentration control in remaking of CIP cleaning agents Product monitoring in pipe systems, bottling plants, quality assurance Leakage monitoring in the following industries Dairies Breweries Beverages (water, juices, soft drinks) Life sciences The sensor can be used with the transmitters Liquiline M CM42, Liquisys M CLM223/253 and Mycom S CLM153; it is part of the measuring system Smartec S CLD134 and compatible with the transmitter electronics of Smartec S CLD132. A G Y H I P N O I R C U N G P U I N O R G R I N N G G D S I Standard Number 74-03 With quality certificate R 0 Your benefits Unique hygienic design, thus no risk of recontamination With all hygienic certificates required in hygienic applications With all process connections commonly used in hygienic applications Durable thanks to encapsulated, jointless design Fast measurement with temperature response time t 90 under 26 s enables safe and efficient phase separations Insensitive to electrode soiling and polarization thanks to electrodeless, inductive measuring principle Suitable for application in hazardous areas TI400C/24/ae/01.08

Function and system design Measuring principle Inductive conductivity measurement A generator (1) generates an alternating magnetic field in the primary coil (2) which induces a current in the medium (3). The strength of the induced current depends on the conductivity and thus the ion concentration of the medium. The current flow in the medium generates another magnetic field in the secondary coil (4). The resulting current induced in the coil is measured by the receiver (5) and processed to determine the conductivity. 1 5 Inductive conductivity measurement 1 Generator 2 Primary coil 3 Current flow in the medium 4 Secondary coil 5 Receiver 2 4 Benefits of inductive conductivity measurement No electrodes, therefore no polarization Accurate measurement in media or solutions with a high soiling degree and a tendency to deposition Complete galvanic separation of measurement and medium 3 a0004894 Important properties Indumax H CLS54 Hygiene The injection-molded sensor is made of highly chemically, mechanically and thermally resistant PK. It does not have joints or crevices and is therefore hygienically safe. The exclusive use of virgin PK as material in contact with medium guarantees highest biological safety for the food, beverage and pharmaceutical areas. The sensor has been designed according to the effective guidelines of ASM BP (The American Society of Mechanical ngineers - Bioprocessing quipment). Certified hygiene The sensor has all necessary listings and approvals for hygienic areas, such as exclusive use of FDA-listed materials for surfaces in contact with medium and certification according to HDG guidelines (uropean Hygienic ngineering and Design Group) as well as 3-A. A certificate on the biological reactivity test according to USP part <87> and <88> class VI including lot tracing back to compounding is available as option. Process connections The sensor is available with all process connections commonly used in hygienic applications. The most common connections are available as standard. Further process connections can be ordered as special versions. Process temperature, process pressure The use of special components and materials makes the sensor suitable for continuous exposure to temperatures of +125 C (275 F). Short-time (max. 60 min.), it may be exposed to +150 C (300 F) for sterilization. The sensor is pressure-resistant up to 12 bar (174 psi) up to 90 C (194 F). At higher temperatures, its pressure resistance is always higher than the respective steam pressure. The sensor is suitable for underpressure applications. Temperature measurement The sensor has an integrated temperature sensor with a temperature response time t 90 < 26 s. This enables economically efficient phase separations at varying and quickly changing process temperatures. The temperature sensor is embedded into the PK body eliminating the need for seals which ensures a long service life. 2 ndress+hauser

} } } Indumax H CLS54 Measuring system A complete measuring system comprises: a CLS54 inductive conductivity sensor a transmitter, e.g. Liquiline CM42 1 2 Measuring system example 1 Indumax H CLS54 2 Transmitter Liquiline CM42 3 Measuring cable 3 a0005431 Input Measured values Conductivity Temperature Cell constant k k = 6.3 cm 1 Measuring ranges Conductivity Temperature recommended range: 100 μs/cm to 2000 ms/cm (uncompensated) 10 to +150 C (+14 to +302 F) Temperature measurement Pt 1000 (class A acc. to IC 60751) Cable specification Indumax H is supplied with a fixed cable. The connection to the transmitter can be extended using the CLK5 special measuring cable. Cable WH RD Shield Fixed cable / CLK5 special measuring cable Coax WH Coax RD Ferrule RD Ferrule BU Ferrule RD Ferrule BU GN WH Y BN n.c. Shield Inner connector Shield Inner connector Pt 1000 a0005433-en Cable length: max. 55 m (180 ft) total length ndress+hauser 3

Performance characteristics Temperature response time t 90 26 s Measured error ± (0.5 % of measured value + 10 μs/cm) after calibration (plus inaccuracy of the conductivity of the calibration solution) Installation Installation instructions The sensor has to be immersed completely into the media. Avoid bubbles in the area of the sensor. A Installation positions of conductivity sensors A Installation position is not usable for hygienic applications. a0005442 The media should flow through the flow opening of the sensor (see indicator arrow of the sensor body). The symmetrical measuring channel allows a flow in both directions. In narrow installation conditions, the ion flow in the medium is affected by the pipe walls. This effect is compensated by the so-called installation factor. The installation factor can be entered in the transmitter or the cell constant can be corrected by multiplication with the installation factor to ensure correct measurement. The value of the installation factor depends on the diameter and the conductivity of the pipe as well as the sensor s distance from the wall. If the distance from the wall is sufficient (a > 15 mm/0.59", from DN 65/2.5"), it is not necessary to consider the installation factor (f = 1.00). If the distance from the wall is smaller, the installation factor increases in case of electrically insulating pipes (f > 1) and decreases in case of electrically conductive pipes (f < 1). The installation factor can be measured using calibration solutions or it can be approximately determined from the diagram beside. Installation of CLS54 a Sensor distance from the pipe wall a a0005453 4 ndress+hauser

f 1.40 2 1.20 1.00 0.80 1 0 5 10 15 20 25 a [mm] Dependance of installation factor f on wall distance a 1 Conductive pipe 2 Insulating pipe 0.20 0.39 0.59 0.79 0.98 a [inch] a0005441 Air set To compensate residual coupling in the cable and between the two sensor coils, you must perform a zero calibration in air ("air set") before installing the sensor. For further information, refer to the Operating Instructions of your transmitter. nvironment Ambient temperature Storage temperature 20 to +60 C (-4 to +140 F) -25 to +80 C (-13 to +176 F) Relative humidity 5 to 95 % Ingress protection IP 68 / NMA 6P (1m / 3.28 ft water column, 50 C / 122 F, 168 h) ndress+hauser 5

Process Process temperature Sterilization Process pressure 10 to +125 C (+14 to +257 F) 150 C / 5 bar (302 F / 72.5 psi), max. 60 min. 12 bar (174 psi) up to 90 C (194 F) 8 bar (116 psi) at 125 C (257 F) 0 to 5 bar (0 to 72.5 psi) when in CNR-applicable areas (tested with 50 bar / 725 psi) underpressure down to 0.1 bar (1.45 psi) absolute Pressure / temperature load curve [psi] [bar] 174 12 116 8 B 72.5 58 5 4 A 10 0 10 30 50 70 90 110 125 150 [ C] 14 32 50 86 122 158 194 230 257 302 Pressure / temperature load curve A short-time sterilization (max. 60 min) B MAWP (maximum allowable working pressure) according to ASM-BPVC Sec. VIII, Div 1, UG101 for CRN registration [ F] a0008379 Mechanical construction Design, dimensions 1 2 3 4 Temperature sensor Housing Process connection Flow opening 2 3 4 1 Indumax H CLS54 a0005430 6 ndress+hauser

133.7 (5.26) 54.5 (2.15) Ø64 (2.52) 28.5 (1.12) 58 (2.28) 78.5 (3.09) Ø9 (0.35) 33 (1.30) Ø6 (0.24) 11.5 (0.45) 10.2 (0.40) mm (inch) Dimensions CLS54 (long version) a0005429 Weight Surface roughness Depending on version 0.3 to 0.5 kg (0.66 to 1.1 lb.) plus cable Ra 0.8 μm (smooth, injection-molded PK surface) for the surfaces in contact with medium Materials In contact with medium Not in contact with medium Virgin PK PPS-GF40 Stainless steel 1.4404 (AISI 316L) Screws: 1.4301 (AISI 304) PVDF (cable gland) FKM, PDM (seal) TP (cable) ndress+hauser 7

Process connections Dairy pipe fitting DIN 11851, DN 50 a) Aseptic fitting DIN 11864-1 form A, for pipe according to DIN 11850, DN 50 Clamp ISO 2852 (also for TriClamp, DIN 32676), 2" b) SMS 2" Varivent N DN 40-125 NUMO BioControl D50 (DN 40 / 2") Additional process connections are available on request. a) Dairy pipe fitting DIN 11851 is generally not considered hygienic. With the adapter SKS Siersma, it meets the 3-A standards requirements. b) Process connection is not considered hygienic according to the requirements of HDG. A B 5.26 (133.7) 5.26 (133.7) 3.52 (89.5) 0.70 (17.7) 3.31 (84) 0.63 (16) 0.63 (16) 0.24 (6) 1.44 (36.5) 0.63 (16) 0.24 (6) 1.44 (36.5) Process connections CLS54 (short version) a0004949 A NUMO BioControl D50 for pipe connection: DN 40 (DIN 11866 series A, DIN 11850) DN 42.4 (DIN 11866 series B, DIN N ISO 1127) 2" (DIN 11866 series C, ASM-BP) B Varivent N DN 40 to 125 8 ndress+hauser

A B 5.26 (133.7) 0.43 (11) 5.26 (133.7) 2.01 (51) 2.28 (58) 3.09 (78.5) 2.46 (62.6) 3.09 (78.5) 2.28 (58) 0.16 (4) 2.56 (65) C 0.40 (10.2) 0.40 (10.2) D 5.26 (133.7) 2.28 3.09 (58) (78.5) 0.11 (2.8) 2.20 (55.8) 2.52 (64) 5.26 (133.7) 2.28 3.09 (58) (78.5) 2.63 (66.8) 0.40 (10.2) 0.40 (10.2) Process connections CLS54 (long version) A Dairy pipe fitting DIN 11851, DN 50 B SMS 2" C Clamp ISO 2852, 2" D Aseptic fitting DIN 11864-1 form A, for pipe according to DIN 11850, DN 50 a0005436 lectrical connection Chemical durability Fixed cable connection with cable gland Medium Concentration PK Caustic soda NaOH 0 to 15 % 20 to 90 C (68 to 194 F) Nitric acid HNO 3 0 to 25 % 20 to 90 C (68 to 194 F) Phosphoric acid H 3 PO 4 0 to 15 % 20 to 80 C (68 to 176 F) Sulphuric acid H 2 SO 4 0 to 30 % 20 C (68 F) Peracetic acid H 3 C-CO-OOH 0.2 % 20 C (68 F) No responsibility is taken for the correctness of this information. ndress+hauser 9

Certificates and approvals Hygienic certificates FDA All materials in contact with medium are listet at FDA.! Note! HDG Certified for cleanability according to HDG document 2 The cleanability of a sensor also depends on the way of installation. To install the sensor in a pipe system use the appropriate and HDG certified flow assembly for the respective process connection. 3-A Certified according to 3-A Standard 74-03 ("3-A Sanitary Standards for Sensor and Sensor Fittings and Connections Used on Milk and Milk Products quipment"). Biological reactivity (USP class VI) (optional) Certificate on biological reactivity tests according to USP (United States Pharmacopeia) part <87> and part <88> class VI with traceability of the materials in contact with medium. x approvals ATX II 1G x ia IIC T3/T4/T6 FM/CSA IS NI Cl. I, II, III, Div. 1 & 2; group A - G in connection with the transmitter Liquiline M CM42 Pressure approvals Canadian pressure approval for pipes according to ASM B31.3 Ordering information Product structure Indumax H CLS54 Approval A Non-x area G ATX II 1G x ia IIC T3/T4/T6 O FM IS NI CI. I, II, III, Div. 1 & 2, Group A - G S CSA IS NI CI. I, II, III, Div. 1 & 2, Group A - G T TIIS CLS54- Process connection MV5 Dairy pipe fitting DIN 11851, DN 50 1) AA5 Aseptic fitting DIN 11864-1 form A, pipe DIN 11850, DN 50 CS1 Clamp ISO 2852, 2" (long) SMS SMS, 2" 2) VA4 Varivent N DN 40 to 125 BC5 NUMO BioControl D50 Supplementary equipment 0 Standard 2 Biological reactivity tests according to USP <87>, <88> class VI 3 CRN approval (ASM B31.3) 3) 4 CRN approval (ASM B31.3) 3) + biological reactivity tests according to USP <87>, <88> class VI Cable length 1 Fixed cable 5 m (16.41 ft.) 2 Fixed cable 10 m (32.81 ft.) 3 Fixed cable 20 m (65.62 ft.) Temperature sensor 2 Integrated temperature sensor Pt 1000 complete order code 1) Dairy pipe fitting DIN 11851 is generally not considered hygienic. With the adapter SKS Siersma, it meets the 3-A standards requirements. 2) Process connection is not considered hygienic according to the requirements of HDG. 3) CRN approval only valid for process connections MV5, CS1 and VA4. 10 ndress+hauser

Accessories Measuring cables Calibration solutions Related products CLK5 measuring cable xtension cable for connecting CLS52/54 and transmitter via the VBM junction box, sold by the meter; order no. 50085473 Junction box VBM For cable extension 10 terminals Cable entries: 2 x Pg 13.5 or 2 x NPT ½" Material: aluminum Ingress protection: IP 65 (i NMA 4X) Order numbers: cable entries Pg 13.5: 50003987 cable entries NPT ½": 51500177 Precision solutions, traceable to SRM (standard reference material) by NIST, for qualified calibration of conductivity measurement systems according to ISO 9000, with temperature table CLY11-B 149.6 μs/cm (reference temperature 25 C / 77 F), 500 ml / 16.9 fl.oz Order no. 50081903 CLY11-C 1.406 ms/cm (reference temperature 25 C / 77 F), 500 ml / 16.9 fl.oz Order no. 50081904 CLY11-D 12.64 ms/cm (reference temperature 25 C / 77 F), 500 ml / 16.9 fl.oz Order no. 50081905 CLY11-107.0 ms/cm (reference temperature 25 C / 77 F), 500 ml / 16.9 fl.oz Order no. 50081906 Indumax P CLS50 Highly resistant inductive conductivity sensor for standard, hazardous and high-temperature applications; for ordering information, see Technical Information TI182C/24/ae Smartec S CLD134 Measuring system for conductivity and concentration measurement in the food industry; for ordering information, see Technical Information TI401C/24/ae Documentation Transmitters Calibration solutions Mycom S CLM153, Technical Information TI234C/24/ae Liquisys M CLM223/253, Technical Information TI193C/24/ae Liquisys M CLM223F, Technical Information TI237C/24/ae Liquiline M CM42, Technical Information TI381C/24/ae CLS54-G, Safety instructions for electrical equipment in hazardous areas, XA400C/07/a3 Precision calibration solution CLY11, Technical Information TI162C/07/en ndress+hauser 11

United States ndress+hauser, Inc. 2350 ndress Place Greenwood, IN 46143 Tel. 317-535-7138 Sales 888-NDRSS Service 800-642-8737 fax 317-535-8498 inquiry@us.endress.com www.us.endress.com TI400C/24/ae/01.08 2008 ndress+hauser, Inc. Canada ndress+hauser Canada 1075 Sutton Drive Burlington, ON L7L 5Z8 Tel. 905-681-9292 800-668-3199 Fax 905-681-9444 info@ca.endress.com www.ca.endress.com Mexico ndress+hauser, México, S.A. de C.V. Fernando Montes de Oca 21 dificio A Piso 3 Fracc. Industrial San Nicolás 54030. Tlalnepantla de Baz stado de México México Tel: +52 55 5321 2080 Fax +52 55 5321 2099 eh.mexico@mx.endress.com www.mx.endress.com